• 제목/요약/키워드: Static Condenser

검색결과 37건 처리시간 0.024초

전압원인버터방식 송전용 무효전력보상기의 제어시스템 설계 (Control System Design for Self-Commutated Static Var Compensator)

  • 한병문
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1996년도 창립기념 전력전자학술발표회 논문집
    • /
    • pp.89-92
    • /
    • 1996
  • This paper describes a detailed simulation model of the static condenser (STATCON) to analyze the dynamic interaction with the ac transmission line. The static condenser was represented by a 12-pulse voltage-source inverter sharing an energy storage dc capacitor. The voltage-source inverter consists of two 6-pulse bridges modeled with ideal gate-turn-off switches. The control system for the static condenser was designed through a mathematical model deduced from the equivalent circuit. Simulation results show that the conceived model is very effective to analyze the dynamic interaction between the static condenser and the ac transmission system.

  • PDF

계통손실 감소를 위한 전력용 콘덴서의 適正 再配置에 대한 연구 (A Study on the System Loss Minimizing Algorithm by Optimal Re-location of Static Condenser Using System Power Loss Sensitivity)

  • 이상중;김건중;정태호;김원겸;김용배
    • 대한전기학회논문지
    • /
    • 제44권1호
    • /
    • pp.21-24
    • /
    • 1995
  • The larger and the more complicated the system size and configuration grow, the more serious the system loss problem becomes. Exessive system loss causes severs system voltage depression, which even may result in system voltage collapse. This paper proposes an effective tool for minimizing the system power loss by optimal re-location of the static condenser based on the system loss sensitivity index .lambda.$_{Q}$. It is possible to determine the optimal location and amount of VAR investment for minimizing the system loss by priority of .lambda.$_{Q}$ index given for each bus. Several computational techniques for avoiding divergency of the load flow solution are proposed. The loss sensitivity index .lambda.$_{Q}$ uses information of normal power flow equations and their Jacobians. Two case studies proved the effectiveness of the algorithm proposed.posed.

  • PDF

EMTP를 이용한 스타콘뱅크의 투입써-지 해석 (Analysis of closing surge in static condenser bank using EMTP)

  • 원영진;서순교;정태호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.673-675
    • /
    • 1992
  • The operation of condenser-bank is now increasing around Kyoungin area. The operation of condenser-bank is used for the improvement of under voltage and expand of power demand. But the operation has the problem in itself as the switching over voltage. This report deals with the static-condenser fault caused by abnormal operation of circuit breaker which has occurred last summer. We have analyzed this fault using EMTP(electromagnetic transient program).

  • PDF

스펀지 볼을 이용한 원전용 복수기 튜브 세정 시스템 개발 (Development on Cleaning System of Condenser for Nuclear Power Plant by Using Sponge Ball)

  • 이중섭;이치우
    • 한국기계가공학회지
    • /
    • 제14권6호
    • /
    • pp.21-26
    • /
    • 2015
  • This study presents a development of the cleaning system in a nuclear power plant condenser. The tube cleaning system is very important equipment in a power plant condenser. Specially, removal of the fouling is a key process in the condenser tube. The objective of this study is development of a ball collector system for cleaning a condenser by using a sponge ball. This study uses CFD in order to optimize design of the ball strainer screen. Through the CFD, the implication of the ball strainer screen for static pressure distribution is examined. Results of research, this study have developed a 1/5 scale model for application to the power plant and developed a performance test equipment.

볼 여과기 스크린 모듈의 단면 폐쇄효과에 관한 수치해석적 연구 (Numerical Analysis of Ball Strainer Screen Module Blockage Effects)

  • 정경철;이해수;이치우
    • 동력기계공학회지
    • /
    • 제19권1호
    • /
    • pp.83-89
    • /
    • 2015
  • A ball strainer screen module, which is used for a condenser tube cleaning system, is a critical mechanical component for maintaining condenser cleanliness. Despite of this importance, not many research have been focused on this module because of its relatively low usage. Employing CFD, this study examines the implication of fluid velocity change and blockage ratio on the ball strainer screen velocity and the static pressure distribution. Through this study, the impact of blockage in the space between ball strainer screen modules is verified. Also, it is found that the ranges of non-dimensional velocity distribution and static pressure distribution decrease as blockage ratio becomes smaller.

SC 전용 보호계전기 개발 (Research for Protection Relay of Static Condenser Bank)

  • 정재기;윤시영;김석중;김근규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.48-50
    • /
    • 2006
  • SC(Static Condenser) in KEPCO is used in voltage control and power factor compensation. Currently KEPCO uses SC to 154kv 50MVA and 23kv SMVA. It is not important in old days because a SC bank accident has no effect on power system. But we are interested in the SC bank for power quality in these days. The SC Bank has a reactor and a condenser using series connection. It is operated in critical point for resonance circuit normally. Therefore the SC bank has a small reliability against other Power instruments. If a 4th harmonic frequency as a resonance frequency is supplied in system, the condenser is damaged because of a resonance current. And a trip and a closing for CB(Circuit Breaker) in many times will have a big influence of SC bank destruction. General OCR(Over Current Relay) observing SC bank is not useful for this protection We think that protection relay must be have the SC bank characteristics. A solution for this problem is active Power, resonance frequency and impedance.

  • PDF

공조기 제어를 위한 응축기의 동특성 해석 (Analysis of Dynamic Characteristics on Condenser for the Control of Air Conditioning Systems)

  • 김재돌;윤정인;통구 김차랑
    • 설비공학논문집
    • /
    • 제8권3호
    • /
    • pp.386-396
    • /
    • 1996
  • The dynamic characteristics of a condenser are numerically studied for the control of air-conditioning systems. The important factors, such as the refrigerant flow rate and refrigerant temperature, air velocity and air temperature at the condenser inlet, are incorporated into the analysis. This study was focused on the analysis of dynamic responses by transfer function method in the condenser. Block diagrams were made through analytic transfer function, and dynamic responses are evaluated on Bode diagrams in the frequency response. These results may be used for determining an optimum design parameters in an actual component and total systems. Also, the mathematical models, frequency response and steady state response may be used to increase understanding, to obtain useful information for its commercialization, to evaluate the hardware and the optimum design parameters, the design control system and to determine the best controller setting for the refrigeration and air conditioning systems.

  • PDF

유연송전시스템에서의 역률 보상을 위한 배전용 정지형 동기조상기의 전류제어 (Predictive Current Control of Distribution Static Condenser (D-STATCON) for Reactive Power Compensation in Flexible AC Transmission System(FACTS))

  • 오관일;문건우;전영수;이기선;추진부
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.447-454
    • /
    • 1998
  • This paper describes a modeling and current control techniques of Distribution static condenser (D-STATCON) for power factor compensation. The current control is based on the predictive and the space vector PWM scheme. The predictive current controlled PWM D-STATCON can maintain its performance with power factor compensation and fixed switching frequency. By using the space vector control low ripple and offset in the current and the voltage as well as fast dynamic responses are achieved with a small DC link capacitance employed.

  • PDF

정지형 동기조상기의 역률개선을 위한 전류제어 (Current Control For Power Factor Correction of Distribution Static Condeser (D-STATCON))

  • 문건우;윤석호;전영수;장병훈;이기선;추진부
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1997년도 전력전자학술대회 논문집
    • /
    • pp.280-284
    • /
    • 1997
  • In this paper theoretical foundation of distribution STATCON, the operating characteristics of D-STATCON, the overview of control technologies for power factor correction of D-STATCON, and the PWM current control of D-STATCON and simulated results are given to shows the practical feasibility of a Flexible AC Transmission System and Distribution Static Condenser.

  • PDF

Technique for the Prevention of Inrush Current in a TCC Reactive Power Compensator

  • Yang, Ji-Hoon;Song, Sung-Geun;Park, Seong-Mi;Park, Sung-Jun
    • 한국산업융합학회 논문집
    • /
    • 제21권4호
    • /
    • pp.149-158
    • /
    • 2018
  • With the propagation and spread of the new regeneration energy and increase in electricity demand, power systems tend to be decentralized, and accordingly, the use of a power system stabilizer tends to expand for the stabilization of the distribution system. Thus, typical power system stabilizer, Static Var Compensator (SVC) is developed on a variety of topologies. In addition, the trend of technology leads from SVC to Static Synchronous Compensator(STATCOM) technology development. Recently, to overcome STATCOM's conversion losses and economic disadvantages, studies of a hybrid method using STATCOM and SVC in parallel have actively been conducted. This study proposes a new Soft-Step Switching method to limit inrush current problematic in Thyristor Controlled Capacitor (TCC) method in SVC function. In addition, to reduce Statcom's capacity, groups of reactive power compensation reactor and condenser for SVC were designed.