• Title/Summary/Keyword: Static Characteristic

Search Result 509, Processing Time 0.029 seconds

A hysteresis model for soil-water characteristic curve based on dynamic contact angle theory

  • Liu, Yan;Li, Xu
    • Geomechanics and Engineering
    • /
    • v.28 no.2
    • /
    • pp.107-116
    • /
    • 2022
  • The steady state of unsaturated soil takes a long time to achieve. The soil seepage behaviours and hydraulic properties depend highly on the wetting/drying rate. It is observed that the soil-water characteristic curve (SWCC) is dependent on the wetting/drying rate, which is known as the dynamic effect. The dynamic effect apparently influences the scanning curves and will substantially affect the seepage behavior. However, the previous models commonly ignore the dynamic effect and cannot quantitatively describe the hysteresis scanning loops under dynamic conditions. In this study, a dynamic hysteresis model for SWCC is proposed considering the dynamic change of contact angle and the moving of the contact line. The drying contact angle under dynamic condition is smaller than that under static condition, while the wetting contact angle under dynamic condition is larger than that under static condition. The dynamic contact angle is expressed as a function of the saturation rate according to the Laplace equation. The model is given by a differential equation, in which the slope of the scanning curve is related to the slope of the boundary curve by means of contact angle. Empirical models can simulate the boundary curves. Given the two boundary curves, the scanning curve can be well predicted. In this model, only two parameters are introduced to describe the dynamic effect. They can be easily obtained from the experiment, which facilitates the calibration of the model. The proposed model is verified by the experimental data recorded in the literature and is proved to be more convenient and effective.

Static and Fatigue Fracture Assessment of Hybrid Composite Joint for the Tilting Car Body (틸팅차량용 차체의 Hybrid 복합재 접합체결부의 정적 및 피로 파괴 평가)

  • Jung, Dal-Woo;Kim, Jung-Seok;Seo, Sueng-Il;Jo, Se-Hyun;Choi, Nak-Sam
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.2 s.257
    • /
    • pp.166-173
    • /
    • 2007
  • Fatigue fracture behavior of a hybrid bolted joint was evaluated in comparison to the case of static fracture. Two kinds of specimens were fabricated for the mechanical tests; a hybrid bolted joint specimen for the shear test and a hybrid joint part specimen applied in the real tilting car body for the bending test. Characteristic fracture behaviors of those specimens under cyclic toads were obviously different from the case under static loads. For the hybrid bolted joint specimen, static shear loading caused the fracture of the bolt body itself in a pure shear mode, whereas cyclic shear loading brought about the fracture at the site of local tensile stress concentration. For the hybrid joint part specimen, static bend loading caused the shear deformation and fracture in the honeycomb core region, while cyclic bend loading did the delamination along the interface between composite skin and honeycomb core layers as well as the fracture of welded joint part. Experimental results obtained by static and fatigue tests were reflected in modifications of design parameters of the hybrid joint structure in the real tilting car body.

A Study on the Characteristic Analysis of the Load-sensitive Hydraulic Pump Control System (부하 감응형 유압 펌프 제어 시스템의 특성 해석에 관한 연구)

  • 이용주;이승현;송창섭
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.4
    • /
    • pp.148-154
    • /
    • 2000
  • In this study, the static and the dynamic characteristics of the load-sensitive hydraulic pump control systems of a hydraulic excavator were analyzed using the developed analysis tool. The results were compared with the experimental ones. To improve the static performance of the system, the system parameter effects on the controllable region and the pump pressure variation were studied. The parameters enhancing dynamic characteristics were also considered.

  • PDF

Characteristic Analysis of Motor using VIS (VIS를 이용한 전기기기 특성 해석)

  • Lee, I.Y.;Kim, Y.W.;Kim, Y.M.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07e
    • /
    • pp.126-129
    • /
    • 2004
  • This paper presents the way to analyze the static and dynamic characteristics of the Compound motor and 3 phase slip ring motor using VIS (Virtual Instrument System) and Agilent VEE, GUI(Graphics User Interface) tool. This method is composed of real time measuring of various characteristics, which can't measure using analog meter and analyzer, and presenting and analyzing the static and dynamic characteristics by table, which calculates the measured parameter. Also, this can apply to the various parts.

  • PDF

A Study on the Static Levitation Control of Magnetic Bearing using Optical Fiber Displacement Sensors (광파이버 변위 센서를 적용한 자기베어링 정적 부상 제어 연구)

  • 강종규;신우철;홍준희
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.131-136
    • /
    • 2003
  • Five expensive sensors are necessary to control a magnetic bearing system. The sensor price rate of magnetic bearing system is high. So it is necessary that cheap and good sensor is developed. The optical fiber displacement sensor is adaptive to satisfy this condition. We can design magnetically suspended spindle based on static characteristic of optical fiber displacement sensor developed. The controller can be designed by decoupled feedback PD. Therefore, it is simpler than any other controller comparatively.

  • PDF

Test of Static Characteristic of a Voice-coil type LOA (보이스 코일형 LOA의 정상특성 실험)

  • Jang, S.M.;Jeong, H.I.;Jeong, S.S.;Kim, H.G.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.294-296
    • /
    • 1997
  • LOA(Linear Oscillating Actuator) is composed of a voice coil type mover and permanent magnets. we have applied LOA to the active vibration control system to supress structual vibration. In this paper, the static test of the voice coil type LOA is treated. The thrust developed by LOA is calculated by measuring stroke.

  • PDF

A study on performance evaluation of rod rubber bushing under static and fatigue loadings (토크 로드 부품의 정하중 및 피로하중하에서의 성능평가 연구)

  • 이순복;김완두
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.5
    • /
    • pp.1320-1329
    • /
    • 1990
  • A static performance tester for a torque rod assembly was developed to evaluate the three characteristics of the rod rubber bushing : radial spring characteristic, thrust spring characteristic, and rotational torque characteristic. Among the various schemes considered in the conceptual design stage, the final versatile type was determined to perform three different tests in one machine. The performance testing machine carried out radial spring test, thrust spring test, and torque test of the torque rod assembly. Static performance of the torque rod assembly was evaluated with the tester developed and fatigue strength of the assembly was also tested with the servo-hydraulic structural fatigue testing machine. The life of the component was found to be related with the rubber quality and adhesionability between the rubber and the steel rod. The optimum rubber hardness was experimentally found by changing the chemical compositions of rubber, and the adhesion was improved by optimizing the shape of the outer section of a the rubber, this study ensured the development of a reliable torque rod assembly.

Bedding Fabric Performance Using Polyester, Tencel and Cotton MVS Blended Spun Yarns (PET, Tencel, Cotton MVS 혼방사로 제직된 침구용 직물의 성능평가)

  • Sa, A-Na;Lee, Jung Soon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.41 no.1
    • /
    • pp.17-27
    • /
    • 2017
  • This study evaluated the performance of bedding fabrics consisting of warp (150d/144f, polyester) and weft (polyester, Tencel and cotton MVS blended spun yarn) with blend ratio of weft. We measured electrostatic propensity, moisture properties, pilling properties and mechanical properties of the fabrics for this study. F-P fabric showed outstanding moisture properties and pilling properties. However, tensile properties and electrostatic propensity were relatively inferior to other characteristic values. Significant static electricity may make F-P fabric uncomfortable. F-P7C3 fabric showed outstanding moisture properties and pilling properties. Static electricity may make F-P7C3 fabric uncomfortable; in addition, F-P5C5 fabric showed outstanding moisture properties and pilling properties. Rough and stiff hand feel were expected to increase because tensile properties decreased and surface properties increased. F-C fabric showed outstanding pilling properties and electrostatic propensity. However, it showed inferior moisture control properties. F-P5T4C1 fabric showed outstanding moisture properties, pilling properties and electrostatic propensity. Several properties are outstanding; however, the hand feels are very rough and stiff from bending. The water evaporation and static electricity increased with increasing polyester content. As the content of cotton increased, tensile properties were improved. However, water evaporation and static electricity decreased. The addition of Tencel increased the thickness and compression energy so that it exhibited a soft characteristic upon compression and an excellent moisture control properties, but the surface became somewhat coarse.

The comparison of ESD prevention characteristic of TVS with a Varistor at low voltage (저압회로에서의 TVS와 Varistor의 ESD 방지특성 비교)

  • 최홍규;송영주;이완윤
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.105-109
    • /
    • 2002
  • A TVS and Varistor are preservative equipment against electro static discharge(ESD). We use a TVS for I/O protection of a circuit which has faster response time than a Varistor. And a Varistor has large power capability, therefore, which be used in input stage for internal pressure prevention. This paper will compare a TVS with a Varistor with respect to response characteristic to ESD in DC 24[V] low voltage circuit.

  • PDF