• Title/Summary/Keyword: Statement Analysis

Search Result 599, Processing Time 0.026 seconds

Prisma Statement: The Strategic Advantages and Disadvantages of Foreign Direct Investments (FDI)

  • Phouthakannha NANTHARATH
    • The Journal of Industrial Distribution & Business
    • /
    • v.14 no.10
    • /
    • pp.1-9
    • /
    • 2023
  • Purpose: In an increasingly globalized world, foreign direct investment (FDI) plays an essential role in the economic improvement of countries. This study aims to delve into the topic of overseas direct investment (FDI) and offer a complete analysis of its strategic advantages and disadvantages. By thoroughly examining the present literature, this study aims to discover and explore the diverse advantages and drawbacks. Research design, data and methodology: The information analysis system systematically and rigorously examined the selected studies. The evaluation will follow a thematic technique in which conventional subject matters and styles associated with FDI's strategic benefits and downsides can be recognized and synthesized. Data extraction contained relevant facts from the chosen research, along with the study objectives. Results: This study provides the findings of the, which explores the strategic advantages and disadvantages of foreign direct investments (FDI) primarily based on the evaluation of previous research. A comprehensive review of the identified benefits and drawbacks highlights their implications for businesses engaged in FDI. Conclusions: In sum, the findings offer valuable insights for practitioners, guiding their decision-making methods in the international commercial enterprise landscape. Organizations can function for fulfillment and sustainable development in the global marketplace by leveraging the advantages and effectively managing demanding situations.

A Systematic Review of Predictive Maintenance and Production Scheduling Methodologies with PRISMA Approach

  • Salma Maataoui;Ghita Bencheikh;Ghizlane Bencheikh
    • International Journal of Computer Science & Network Security
    • /
    • v.24 no.1
    • /
    • pp.215-225
    • /
    • 2024
  • Predictive maintenance has been considered fundamental in the industrial applications in the last few years. It contributes to improve reliability, availability, and maintainability of the systems and to avoid breakdowns. These breakdowns could potentially lead to system shutdowns and to decrease the production efficiency of the manufacturing plants. The present article aims to study how predictive maintenance could be planed into the production scheduling, through a systematic review of literature. . The review includes the research articles published in international journals indexed in the Scopus database. 165 research articles were included in the search using #predictive maintenance# AND #production scheduling#. Press articles, conference and non-English papers are not considered in this study. After careful evaluation of each study for its purpose and scope, 50 research articles are selected for this review by following the 2020 Preferred Reporting Items for Systematic Review and Meta-Analysis Protocols (PRISMA) statement. A benchmarking of predictive maintenance methods was used to understand the parameters that contributed to improve the production scheduling. The results of the comparative analysis highlight that artificial intelligence is a promising tool to anticipate breakdowns. An additional impression of this study is that each equipment has its own parameters that have to be collected, monitored and analyzed.

FACTORS AFFECTING PATIENTS' DECISION-MAKING FOR DENTAL PROSTHETIC TREATMENT

  • Jung, Hyo-Kyung;Kim, Han-Gon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.6
    • /
    • pp.610-619
    • /
    • 2008
  • STATEMENT OF PROBLEM: Factors affecting patients' decision-making for dental prosthetic treatment should be examined in terms of understanding improving patients' oral health. PURPOSE: The main purpose of this dissertation was to investigate patients' dental prosthetic treatment and factors affecting patients' decision-making for dental prosthesis treatment in Deagu and Gyungbook areas. MATERIAL AND METHODS: This study was based on the preliminary survey of dental patients conducted from July 1 to August 31 in 2006. A total of 700 questionnaires had been distributed and 640 were collected. 629 questionnaires were used for the statistical analysis. Descriptive and inferential statistics, such as frequencies, cross tabulation analysis, correlation analysis, logistic regression analysis, and multiple regression analysis were introduced. In the multiple regression analysis and logistic regression analysis, twenty-two independent variables were employed to explore the factors which have impacts on decision-making and satisfaction. RESULTS: The results of this dissertation are as follows: Logistic regression analysis turned out that monthly income, age, degree of expectation, marital status, and employer-insured policy of national insurance statistically increased the odds of decision-making of dental prosthesis treatment. But educational attainment decreased the odds ratio of the decision-making of dental prosthesis treatment. However, the rest independent variables do not have statistically significant impacts on the decision-making of dental prosthesis treatment CONCLUSION: Among independent variables, marital status had the most significant influence on the decision making of dental prosthesis treatment. Finally, suggestions for the future study and policy implications to improve satisfaction of the patients' dental prosthetic treatment were discussed.

AN OPTIMIZATION OF ONEBODY TYPE IMPLANT SYSTEM CONSIDERING VARIOUS DESIGN PARAMETERS (다양한 설계변수를 고려한 수직하중을 받는 일체형 임플랜트의 최적설계)

  • Choi Jae-Min;Chun Heoung-Jae;Lee Soo-Hong;Han Chong-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.2
    • /
    • pp.185-196
    • /
    • 2006
  • Statement of problem: The researches on the influence of design variables on the stress distribution in cortical and trabecular bones and on optimal design for implant system were limited. Purpose: The purpose of this study is to identify the sensitivities of design parameters and to suggest the optimal parameters for designing the onebody type implant system. Material and methods: Stresses arising in the implant system were obtained by finite element analysis using a three dimensional model. An onebody type implant system[Oneplant (Warrantec. Co. Ltd., Korea)] was considered in this study. Vortical load(150 N) was applied on the top of the abutment along the axial direction. The initial design variables set for sensitivity analysis were radius of fixture, numbers of micro thread, numbers of power thread, height of micro thread, future length, tapered angle of future, inclined angle of thread, width of micro thread and width of power thread. The statistical technique of Design of Experiments(DOE) was applied tn the simulation model to deduce effective design parameters on stress distributions in bones. The deduced design parameters were incorporated into a fully automated design tool which is coupled with the finite element analysis and numerical optimization to determine the optimal design parameters. Results: 1. The result of sensitivity analysis showed six design variables - radius of future, tapered angle of fixture, inclined angle of thread, numbers of power thread, numbers of micro thread and height of micro thread - were more influential than the others. 2. The optimal values of design variables can be deduced by coupling finite element analysis (FEA) and design optimization tool(DOT).

The Dynamic Effects of Globalization on the Firm Performance: A Study on Korea Maritime and Fishery Companies

  • Donghyun Lee;Heedae Park;Joongsan Ko
    • Journal of Korea Trade
    • /
    • v.26 no.7
    • /
    • pp.127-144
    • /
    • 2022
  • Purpose - This study aimed to analyze the dynamic effects of progress in globalization on firm performance by employing individual companies' financial statement datasets. Design/methodology - The analysis leveraged the variables of operating revenue (OPRE) and pre-tax profit and loss (PLBT) as measurement variables for firm performance over 2011-2019. As a proxy variable for globalization, the trade index, a subordinate indicator of the KOF Globalization Index, was used. Through panel regression analysis, the relationship among those variables was ascertained, and the local projection (LP) method was subsequently utilized to identify dynamic effects. A subsample analysis was further performed by classifying companies based on their sizes and industries to determine the differential effects of globalization on each group. Findings - The panel regression analysis derived positive effects of an increasing degree of globalization on OPRE of Korea maritime and fishery firms. However, the impulse response functions, obtained from the LP, showed that in the short run, globalization affects PLBT negatively but in the long run, it gradually converted into a positive effect. In addition, according to the subsample analysis based on company size, the effects of globalization on OPRE became greater as each company became larger. Moreover, the industry-based analysis showed heterogeneous effects, depending on the industries in which the maritime and fishery companies operated. Originality/value - The analysis of the dynamic effects of globalization on firm performance, which revealed that the effects vary depending on the time points, is the important contribution of this study. The results also suggest that the effects of globalization vary depending on the company size and industry.

THREE DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS OF FIVE DIFFERENT TAPER DESIGN IMPLANT SYSTEMS (3차원 유한요소법적 분석을 이용한 5종의첨형 임플랜트에 발생하는 응력의 비교연구)

  • Byun, Sang-Ki;Park, Won-Hee;Lee, Young-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.5
    • /
    • pp.584-593
    • /
    • 2006
  • Statement of problem : Dental implant which has been developed gradually through many experiments and clinical applications is presently used to various dental prosthetic treatments. To conduct a successful function of implant prosthesis in oral cavity for a long time, it is important that not only structure materials must have the biocompatibility, but also the prosthesis must be designed for the stress, which is occurred in occlusion, to scatter adequately of load support. Therefore, it is essential to give the consideration about the stress analysis of supporting tissues for higher successful rates. Purpose : Recently, many implant manufacturing company produce various taper design of root form implant, the fixture is often selected. However, the stress analysis of taper form fixture still requires more studies. Material and method : This study we make the element models that five implant fixture; Branemark system(Nobel Biocare, Gothenberg, Sweden), Camlog system(Altatec, Germany), Astra system(Astra Tech, Sweden), 3i system(Implant Innovations Inc, USA), Avana system(Osstem, Korea) were placed in the area of mandibular first premolar and prosthesis fabricated, which we compared with stress distribution using the three-dimension finite element analysis under two loading condition. Results : This study compares the aspect of stress distribution of each system with the standard of Von mises stress, among many resulted from finite element analysis so that this research gets the following results. 1. In all implant system, oblique loading of maximum Von mises stress of implant, alveolar bone and crown is higher than vertical loading of those. 2. Regardless of loading conditions and type of system, cortical bone which contacts with implant fixture top area has high stress, and cancellous bone has a little stress. under the vertical loading, maximum Von mises stress is more higher in order of Branemark, Camlog, Astra, 3i, Avana. under the horizontal loading, maximum Von mises is more higher in order of Camlog, Branemark, Astra, 3i, Avana.

APPLICATION OF FINITE ELEMENT ANALYSIS TO EVALUATE PLATFORM SWITCHING

  • Kim Yang-Soo;Kim Chang-Whe;Jang Kyung-Soo;Lim Young-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.6
    • /
    • pp.727-735
    • /
    • 2005
  • Statement of problem. Platform switching in implant prosthesis has been used for esthetic and biological purpose. But there are few reports for this concept. Purpose. The purpose of this study is evaluation of platform switching in wide implant by three dimensional finite element analysis. Materials and Methods. The single implant and prosthesis was modeled in accordance with the geometric designs for Osstem implant system. Three-dimensional finite element models were developed for (1) a wide diameter 3i type titanium implant 5 mm in diameter, 13 mm in length with wide cemented abutment, titanium alloy abutment screw, and prosthesis (2) a wide diameter 3i type titanium implant 5 mm in diameter, 13 mm in length with regular cemented abutment, titanium alloy abutment screw and prosthesis(platform switching) was made for finite element analysis. The abutment screws were subjected to a tightening torque of 30 Ncm. The amount of preload was hypothesized to 650N, and round and flat type prostheses were loaded to 200 N. Four loading offset point (0, 2, 4, 6 mm from the center of the implants) were evaluated. Models were processed by the software programs HyperMesh and ANSA. The PAM-CRASH 2G simulation software was used for analysis of stress. The PAM-VIEW and HyperView were used for post processing. Results. The results from experiment were as follows; 1. von Mises stress value is increased in order of bone, abutment, implant and abutment screw. 2. von Mises stress of abutment screw is lower when platform switching. 3. von Mises stress of implant is lower when platform switching until loading offset 4 mm. 4. von Mises stress of abutment is similar between each other. 5. von Mises stress of bone is slightly higher when platform switching. Conclusion. The von Mises stress pattern of implant components is favor when platform switch ing but slightly higher in bone stress distribution than use of wide abutment. The research about stress distribution is essential for investigation of the cortical bone loss.

Discourse Analysis of the 1970s Myungrang Manwha (1970년대 한국 명랑만화의 담론분석)

  • Kim, Dae-Keun
    • Cartoon and Animation Studies
    • /
    • s.43
    • /
    • pp.255-284
    • /
    • 2016
  • This article aims at a discourse analysis on the selected 1970s Myungrang Manwhas, in the cases of Ggubungi, Doggaebi Gamtu, Yochul Balmyungwang. For the analysis, the history, pre-censorship, and distribution structure of Myungrang Manwha are referenced, as well as the considerable changes and developments on the definition of 'myungrang' since the 1920s. In employing Foucauldian discourse analysis to the texts, the selected Myungrang Manwhas are analyzed as discursive formation, which emerged within the social relations of the era; the characters' dialogues are analyzed as statement. The analysis examines the discourses that the texts disseminated, and the social context of the utterance. It is demonstrated that the Myungrang Manwhas are forms of representation, which implies 'the contested acquisition on capital and power', 'the emphasis on nationalist aspects', and 'the interpellation and discipline of subject active' of the time. Moreover, it is revealed that the forms of control, such as pre-censorship, were the articulation of the will to power, which drove the discoursive formation to function as an apparatus that meticulously constituted the ruling ideology. In conclusion, the Myungrang Manwhas are rather texts that encompasses political and social context of the era than a mere comic relief.

COMPARISON BETWEEN $TIUNITE^{TM}$ AND ANOTHER OXIDIZED IMPLANT USING THE RABBIT TIBIA MODEL

  • Yeo, In-Sung;Lee, Jai-Bong;Han, Jung-Suk;Kim, Sung-Hun;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.3
    • /
    • pp.339-344
    • /
    • 2007
  • Statement of problem. Various anodic oxidation techniques can be applied to dental implant surfaces. But the condition for optimal anodized surfaces has not been described yet. Purpose. The purpose of this investigation was to compare an implant that was oxidized by another method with $TiUnite^{TM}$ through resonance frequency analysis and histomorphometry. Material and methods. Turned (control), $TiUnite^{TM}$ and another oxidized fixtures, which used $Ca^{2+}$ solution for anodic oxidation, were placed in the tibiae of 5 New Zealand White rabbits. The bone responses were evaluated and compared by consecutive resonance frequency analysis once a week for 6 weeks and histomorphometry after a healing period of 6 weeks. Results. At the first week, both oxidized implants showed significantly higher implant stability quotient (ISQ) values than the control. No significant differences in resonance frequency analysis were found between the two oxidized groups for 6 weeks. The means and standard deviations of bone-to-implant contact (BIC) ratios were $71.0{\pm}4.2$ for $TiUnite^{TM}$, $67.5{\pm}10.3$ for the $Ca^{2+}$-based oxidation fixture, $22.8{\pm}6.5$ for the control. Both oxidized implants were significantly superior in osseointegration to the turned one. There was, however, no statistically significant difference between the two oxidized implants. Conclusion. $TiUnite^{TM}$ and the $Ca^{2+}$-based oxidation fixture showed superior early bone response than the control with respect to resonance frequency analysis and histomorphometry. No significant differences between the oxidized groups, however, were found in this investigation using the rabbit tibia model.

A STUDY ON THE VARIOUS IMPLANT SYSTEMS USING THE FINITE ELEMENT STRESS ANALYSIS (수종의 임플랜트 시스템에 따른 유한요소법적 응력분석에 관한 연구)

  • Yu Seong-Hyun;Park Won-Hee;Park Ju-Jin;Lee Young-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.2
    • /
    • pp.207-216
    • /
    • 2006
  • Statement of Problem: To conduct a successful function of implant prosthesis in oral cavity for a long time, it is important that not only structure materials must have the biocompatibility, but also the prosthesis must be designed for the stress, which is occurred in occlusion, to scatter adequately within the limitation of alveolar bone around implant and bio-capacity of load support. Now implant which is used in clinical part has a very various shapes, recently the fixture that has tapered form of internal connection is often selected. However the stress analysis of fixtures still requires more studies. Purpose: The purpose of this study is to stress analysis of the implant prosthesis according to the different implant systems using finite element method. Material and methods: This study we make the finite element models that three type implant fixture ; $Br{\aa}nemark$, Camlog, Frialit-2 were placed in the area of mandibular first premolar and prosthesis fabricated, which we compared with stress distribution using the finite element analysis under two loading condition. Conclusion: The conclusions were as follows: 1. In all implant system, oblique loading of maximum Von mises stress of implant, alveolar bone and crown is higher than vertical loading of those. 2. Regardless of loading conditions and the type of system. cortical bone which contacts with implant fixture top area has high stress, and cancellous bone has a little stress. 3. Under the vertical loading, maximum Von mises stress of $Br{\aa}nemark$ system with external connection type and tapered form is lower than Camlog and Frialit-2 system with internal connection type and tapered form, but under oblique loading Camlog and Frialit-2 system is lower than $Br{\aa}nemark$ system.