• Title/Summary/Keyword: State room design

Search Result 89, Processing Time 0.029 seconds

Risk Based Accidental Limit State Evaluation on Explosion Accident at Shale Shaker Room of Semi-Submersible Drilling Rig (반잠수식 시추선의 Shale Shaker Room 폭발 사고에 대한 위험도 기반 사고한계상태 평가)

  • Yoo, Seung-Jae;Kim, Han-Byul;Park, Jin-Hoo;Won, Sun-Il;Choi, Byung-Ki
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2015.09a
    • /
    • pp.69-73
    • /
    • 2015
  • An evaluation of the accidental limit state (ALS) for design of a semi-submersible drilling rig is one of the essential design requirements as well as ultimate limit state (ULS) and fatigue limit state (FLS). This paper describes the ALS evaluation on the explosion accident at shale shaker room of semi-submersible drilling rig. There are three steps for the ALS evaluation such as structural analysis at concept design, risk based safety design and structural analysis at detailed design. For the ALS evaluation at concept design, conceptual explosion overpressure from the Rule guided by the classification society was used in the structural analysis that was carried out using LS-DYNA. To set up the design accidental load (DAL), explosion analysis was carried out using FLACS taking safety barriers into consideration. Then, the structural analysis was carried out applying DAL for the ALS evaluation at detailed design. Through the ALS evaluation on the explosion at shale shaker room, the importance of the risk based safety design was described.

  • PDF

A Study on PC using State and Demand of User's at Home (주거 내 PC사용공간의 사용실태 및 사용자의식에 관한 연구)

  • Jeong, Byeol-Ah;Kim, Bong-Ae
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2005.11a
    • /
    • pp.143-146
    • /
    • 2005
  • The objective of this study is to provide new direction on house design in consideration of the user's life pattern. To this end, pc usage status at home, demand for pc using space, and requirements for pc room interior were analyzed. A survey was taken by parents and the SPSS win.10 was applied for analysis. The survey was conducted for 2 months, starting May 2004 to see the computer usage at home, demand and satisfaction for the computer's room. The results of this study were as follows; The oldest son or daughter in a family was the main user of the computer, posting 71%. 42percent of respondents said they used the pc in their son's and daughter's room while 36% answered living room. It reflects that the whole family want to use the pc in their sharing room, or for their children's convenience. Currently, inconvenience of space-related constraints for using the pc was not that high, which possibly stems from a lack of awareness of inconvenience in using the pc. However, the need for furniture and space for refreshment was suggested. Through this study, it is expected that new housing designs need to be made to reflect these requirements into interior design and building plan for user's convenience.

  • PDF

가변 풍량 유닛에 의한 실내 공간의 온도제어를 위한 공간의 분할 모델과 상태궤환 제어기의 개발에 관한 연구

  • 박세화;신승철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.10
    • /
    • pp.947-959
    • /
    • 2001
  • We propose a control scheme to control the indoor zone temperature via variable air volume (VAV) unit. To control the room temperature, state space model of the conditioned zone which is partitioned into nine artificial sectional regions is derived. The nonlinearity of the damper motion and actuator are considered for the practical use in the state space system description. The temperature control of the room temperature is performed by manipulating the degree of openness of the damper in relation to the local room temperature and the supplied air flow rate. In general, since a local temperature in the conditioned zone is measured, it is required to estimate the temperature values in each regions for the precise temperature control. We thus design a state observer to estimate the regional temperature, and use these values in the controller. The overall control system consists of the state observer based state feedback with the integral control. We compared the control results of the proposed scheme with those of cascade proportional and integral (PI) control, and showed that the scheme achieved precise control of the conditioned system.

  • PDF

Design of Semiconducting Gas Sensors for Room-Temperature Operation

  • Song, Young Geun;Kim, Gwang Su;Ju, Byeong-Kwon;Kang, Chong-Yun
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.1
    • /
    • pp.1-6
    • /
    • 2020
  • Gas sensors that operate at room temperature have been extensively studied because of sensor stability, lift time, and power consumption. To design effective room-temperature gas sensors, various nanostructures, such as nanoparticles, nanotubes, nanodomes, or nanofibers, are utilized because of their large-surface-to-volume ratio and unique surface properties. In addition, two-dimensional materials, including MoS2, SnS2, WS2, and MoSe, and ultraviolet-activated methods have been studied to develop ideal room-temperature gas sensors. Herein, a brief overview of state-of-the-art research on room-temperature gas sensors and their sensing properties, including nanostructured materials, two-dimensional materials, the ultraviolet-activated method, and ionic-activated gas sensors, is provided.

Study on the Unsteady Contaminated Particle Transportation in the Flow Field for the Super Clean Room (초청정 클린룸 난류유동장내에서의 오염입자 비정상 전파거동에 관한 연구)

  • 오명도;임학규;배귀남
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.2
    • /
    • pp.430-439
    • /
    • 1990
  • Steady state turbulent airflow and unsteady characteristics of generation, transportation, and recovery behavior of contaminate particles in the simplified 2 dimensional Vertical Laminar Flow (VLF) type clean room was numerically simulated using the low Reynolds number k-over bar.epsilon- turbulent model. Characteristics of airflow in VLF type clean room are greatly affected by the recirculation zone around working surface. The recirculation zone must be considered at the time of clean room design because the recirculation zone whose area increases with increment of inlet velocity exerts bad influence upon the performance of clean room in terms of particle contamination. The location of maximum particle concentration changes from the location of particle source to the recirculation zone, while averaged particle concentration is reduced exponentially with time. Recovery time of clean room with spontaneous particle generation source is inversely proportional to inlet velocity. We introduce nondimensionalized recovery time through the dimensional analysis, which can indicates the general performance of clean room with design structure change. It was identified that .tau. is independent of inlet velocity and background concentration. Therefore .tau. can be the simple factor to compare the different structure of clean room in terms of dynamic response to contamination and becomes larger with better structure of clean room.

A Study of Practical Room Composition for Interior Site Adaptation (인테리어현장 적응을 위한 실기실 구성에 관한 연구)

  • 박의정
    • Korean Institute of Interior Design Journal
    • /
    • no.40
    • /
    • pp.3-9
    • /
    • 2003
  • Today the social concern about Interior Design gradually requires wide comprehension. Also according to demanders' requirement. Colleges cope with speed. Interior Design made by experts for the function and purpose in the conception of decoration. Therefore, Colleges are responsible to educate for more capable professional designers. But management is the first concern for Interior Design Company students are going to work at. Interior Design has not the important state yet in Korea, it is hard to manage the company with only design works on the table. As architectural design side must get some admission, design is apart from construction. but they are worked together in Interior Design. Also, as the architectural design with process detail drawings, interior design is required the detail design for construction. But it is the facts that the college is interested in and concentrated on rather education for design and space plan than intensive education for construction because of the restricted environment of practice room. I propose component and practical use of nude construction department to understand detailed design.

Design of Daylighting Aperture Using Daylight Factor Method and its Evaluation by Distribution of Sky Component (Daylight Factor Method를 이용한 채광창의 설계와 주광율의 직접조도분에 의한 채광창의 평가)

  • Chee, Chol-Kon;Kwon, Young-Hye
    • Proceedings of the KIEE Conference
    • /
    • 1988.11a
    • /
    • pp.210-213
    • /
    • 1988
  • A new and accurate expression to derive a window area is presented with a sequence for daylighting design using Daylight Factor Method process not in its classical point--by-point method but in lumen method as in artificial lighting design process to consider daylight in the early stage of a building design process. Accepting CIE Overcast Sky as the worst state with the lowest sky luminance, a user of a room can have more available daylight in his or her room. In the design process uniformity is checked to ensure reasonably even daylighting by comparing the depth of the room with the computed limiting depth. After these steps the shape and position of window is altered, of which the Sky Component of Daylight Factor under an Overcast Sky, SCo, is investigated and computed in Composite Simpson Multiple Integral so that a building designer or an analyst can choose the best shape and location that satisfies his/her taste and purpose of the room.

  • PDF

The Effect of Music Therapy on Anxiety of Patients in Emergency Room (음악요법이 응급실 환자의 불안에 미치는 영향)

  • Lee, Pyung-Hwa;Suh, In-Sun;Chung, Seung-Hee
    • Korean Journal of Adult Nursing
    • /
    • v.20 no.3
    • /
    • pp.500-511
    • /
    • 2008
  • Purpose: The purpose of this study was to examine the effects of music therapy on anxiety of patients in emergency room. Methods: The study was designed using a noneqivalent control group nonsynchronized design. For 20 minutes, the experimental group(22 patients) had listened to music and the control group(23 patients) had bed rest. A six-item state anxiety scale developed by Marteau and Bekker, which was based on Spielberger's State-Trait Anxiety Inventory, blood pressure and pulse rate were measured to all study participants before and after the intervention. The data was analyzed by the SPSS 12.0 program. Results: 1) The experimental group's state anxiety level were significantly lower than the control group's(t=2.220, p=.032). 2) There were no significant differences in both group's diastolic(t=-.495, p=.623) and systolic blood pressure(t=831, p=.411). 3) The experimental group's pulse rate was significantly lower than the control group's(t=2.363, p=.023). Conclusion: Music therapy may be applied as a nursing intervention to decrease anxiety in emergency room.

  • PDF

Safety assessment of Generation III nuclear power plant buildings subjected to commercial aircraft crash Part II: Structural damage and vibrations

  • Qu, Y.G.;Wu, H.;Xu, Z.Y.;Liu, X.;Dong, Z.F.;Fang, Q.
    • Nuclear Engineering and Technology
    • /
    • v.52 no.2
    • /
    • pp.397-416
    • /
    • 2020
  • Investigations of the commercial aircraft impact effect on nuclear island infrastructures have been drawing extensive attention, and this paper aims to perform the safety assessment of Generation III nuclear power plant (NPP) buildings subjected to typical commercial aircrafts crash. At present Part II, based on the verified finite element (FE) models of aircrafts Airbus A320 and A380, as well as the NPP containment and auxiliary buildings in Part I of this paper, the whole collision process is reproduced numerically by adopting the coupled missile-target interaction approach with the finite element code LS-DYNA. The impact induced damage of NPP plant under four impact locations of containment (cylinder, air intake, conical roof and PCS water tank) and two impact locations of auxiliary buildings (exterior wall and roof of spent fuel pool room) are evaluated. Furthermore, by considering the inner structures in the containment and raft foundation of NPP, the structural vibration analyses are conducted under two impact locations (middle height of cylinder, main control room in the auxiliary buildings). It indicates that, within the discussed scenarios, NPP structures can withstand the impact of both two aircrafts, while the functionality of internal equipment on higher floors will be affected to some extent under impact induced vibrations, and A380 aircraft will cause more serious structural damage and vibrations than A320 aircraft. The present work can provide helpful references to assess the safety of the structures and inner equipment of NPP plant under commercial aircraft impact.