• Title/Summary/Keyword: Statcom

Search Result 231, Processing Time 0.029 seconds

Study on comparisons between PSS/E and Matlab Simulink/SimPower Result on network system data (PSS/E - Matlab Simulink/SimPower 간 순시치 시뮬레이션 비교에 관한 연구)

  • Yoo, Yeuntae;Kim, Kisuk;Lee, Changun;Jang, Gilsoo
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.249-250
    • /
    • 2015
  • Technological advance of power elcetronic devices using semiconductor switches in last several decades, invoke the increase of switching devices' penetration in the system like STATCOM or HVDC and also, increase the difficulty to adjust switching characteristics in the virtual simulating configuration, which are not capable of reflect the detailed phenomena. To investigate harmful effect of switching devices into the grid, detailed modeling of power electronic devices are necessary, and the first step for entire grid modelling is simulate power system in time domain model. In this paper, simple two bus system with synchronous generator and infinite bus on the other side has been compromised in two simulation environment, using PSS/E and Matlab/Simulink. Comparing the result of two simulation result will give answers to the fundamental difference between two type of simulation environment.

  • PDF

New Double-Connected Multi-Step Inverter for High Power Motor Drive Applications (대용량 모터드라이브 적용을 위한 새로운 이중접속방식의 멀티스뎁 인버터)

  • Yang S.U.;Mok H.S.;Choe G.H.;Choi S.W.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.598-601
    • /
    • 2003
  • 본 논문에서는 전압원 인버터의 출력전압 파형을 개선하여 중 $\cdot$ 대용량급 모터드라이버 및 UPS, STATCOM, SVC등에 적용하기 위한 새로운 3상 전압원 인버터를 제안한다. 보조회로로서 사용한 컨버터로 리플전압을 발생시키고 이를 기존의 12-스텝 인버터에 주입하는데 한대의 링크를 사용하면 12-스텝 동작이 24-스텝으로 전환되며 보조 변압기의 1차 권선을 2N(N=1,2,3...)으로 늘리면 24N-스텝으로 전환된다. 본 방식의 타당성을 실험 및 시뮬레이션을 통하여 입증하였다.

  • PDF

The commissioning and test results of 80MVA UPFC (80MVA UPFC 시험 및 운전 결과 분석)

  • Kim S. Y.;Chang B. H.;Kwak N. H.;Yang J. W.;Ryu H. H.
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.159-162
    • /
    • 2003
  • 한국전력공사에서는 전압원 인버터형 FACTS 기기인 UPFC를 전남 강진군 강진변전소에 설치하였다. 강진 UPFC는 한전과 (주)효성이 공동으로 투자하고, 지멘스와의 기술제휴를 통해 개발하였으며, 40MVA 병렬인버터, 40MVA 직렬인버터로 구성되어 총 80MVA 용량이다. 강진 UPFC는 GTO를 이용한 3레벨 인버터 모듈 20MVA 총 4대로 구성되어 있으며, STATCOM, SSSC, UPFC의 3가지 운전모드를 갖는다. 현재 병렬인버터는 강진 모선전압 제어, 직렬인버터는 강진-장흥간의 조류제어에 기여하며, 상용운전 중이다. 본 논문에서는 강진 UPFC 커미셔닝 및 그 운전 결과를 소개하였다.

  • PDF

A Voltage and Frequency Controller for Stand Alone Pico Hydro Generation

  • Kasal, Gaurav Kumar;Singh, Bhim
    • Journal of Power Electronics
    • /
    • v.9 no.2
    • /
    • pp.267-274
    • /
    • 2009
  • This paper deals with a voltage and frequency (VF) controller for an isolated power generation system based on an asynchronous generator (AG) driven by a pico hydro turbine. The proposed controller is a combination of a static compensator (STATCOM) and an electronic load controller (ELC) for decoupled control of the reactive and active powers of the AG system to control the voltage and frequency respectively. The proposed generating system along with its VF controller is modeled in MATLAB using SIMULINK and PSB (Power System Block Sets) toolboxes. The performance of the controller is verified for the proposed system and feeding various types of consumer load such as linear/non-linear, balanced/unbalanced and dynamic loads.

New Reactive-Power Compensator using Thyristor Current-Source Inverter (싸이리스터 전류원인버터를 이용한 새로운 무효전력보상기)

  • Baek, Seung-Taek;Han, Byeong-Mun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.4
    • /
    • pp.219-225
    • /
    • 1999
  • This paper proposes a new reactive-power compensator composed of a thyristor current-source inverter. The compensator consists of a 6-pulse thyristor bridge, dc reactor, and a commutation circuit. The commutation circuit offers the thyristor bridge to have PWM operation with minimal switching losses. The operation of proposed system was analyzed by computer simulations with EMTP and experimental works with hardware scaled-model. The proposed system would have low cost and easy expansion of operation voltage due to using the conventional thyristors.

  • PDF

Control of DSTATCOM for nonlinear load (EMTDC를 이용한 비선형 부하 제어를 위한 배전용 STATCOM 제어)

  • Jung, Soo-Young;Moon, Seung-Il;Kim, Tae-Hyun;Han, Byung-Moon
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.336-339
    • /
    • 2001
  • 본 논문에서는 $\alpha-\beta-0$ 변환 방식을 이용한 제어방식을 모델화 하여 DSTATCOM에 적용하였다. 이러한 변환 방식을 통해서 배전 선로상에 존재하는 역상성분, 영상성분 고조파 성분 등을 나타낼 수 있으며 이에 대한 적절한 보상신호를 연산과정을 통해 생성해 낼 수 있다. 제안된 제어기의 검증을 위해 EMTDC/PSCAD를 이용한 IEEE 13 버스 배전 계통 모델링 및 유도기 부하 모델링 및 사고 모의 및 보상 시뮬레이션을 실시하였다.

  • PDF

System Study for FACTS Pilot Plant Application (FACTS Pilot Plant 도입을 위한 기본 계통 해석)

  • Kim, H.M.;Chun, Y.H.;Jeon, J.H.;Kook, K.S.;Oh, T.K.;Lee, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.90-92
    • /
    • 2001
  • This Paper presents a part of system study results for UPFC Pilot Plant application in Korea. The system study includes short circuit rate of Kangjin S/S which is site of UPFC Pilot Plant, ${\Delta}V/{\Delta}Q$ characteristics in STATCOM mode, P and Q flow control boundary of UPFC Pilot Plant. The system study is simulated by PSS/E Ver. 26.

  • PDF

A study of UPFC model for Power system Analysis (전력계통 해석을 위한 UPFC 모델 연구)

  • Chang, Byung-Hoon;Jun, Young-Su;Kim, Jong-Sun;Lee, Ki-Sun;Chu, Jin-Bu;Baek, Young-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.832-834
    • /
    • 1997
  • 최근 전력계통 운용상 문제점을 해결하기 위하여 대용량 반도체 스위칭 소자를 이용한 전력전자 설비인 FACTS에 관한 연구가 활발히 진행되고 있다. FACTS 설비는 신속한 응답, 다양한 출력변화, 정교한 출력제어 등의 특성으로 전력 계통 적용시 송전용량 증대, 조류제어 등의 효과를 가져오고 있다[7,8]. 본 논문에서는 최근 개발된 FACTS설비인 UPFC(Unified Power Flower Controllers)에 대한 실계통 적용검토 연구를 위하여, 계통모의용 모델을 제시하고, 이에 대한 적용효과를 샘플계통에서 기존의 FACTS설비인 SVC, STATCOM과 비교하였다.

  • PDF

Dynamic Characteristics Analysis of Multi-bridge PWM Inverter SSSC (다중브리지 PWM 인버터로 구성된 SSSC의 동특성 분석)

  • 한병문;박덕희;김성남
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.6
    • /
    • pp.296-302
    • /
    • 2001
  • This paper proposes a SSSC based on multi-bridge inverters. The dynamic characteristic of the proposed SSSC was analyzed by EMTP simulation and a scaled hardware model, assuming that the SSSC is inserted in the transmission line of the one-machine-infinite-bus power system. The proposed SSSC has 6 multi-bridge inverters per phase, which generates 13 pulses for each half period of power frequency. The proposed SSSC generates a quasi-sinusoidal output voltage by 90 degree phase shift to the line current. The proposed SSSC does not require the coupling transformer for voltage injection, and has a flexibility in operation voltage by increasing the number of series connection.

  • PDF

Establishment of Custom Power Device Test Center (전력품질 향상기기 실증시험장 구축)

  • Jeon, Y.S.;Kim, S.Y.;Yoon, J.S.;Jang, B.H.;Park, S.H.;Kwak, N.H.;Jeong, Y.H.;Choo, J.B.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.154-156
    • /
    • 2003
  • 고도화 정보화시대의 도래로 수용가측의 전력품질에 대한 관심이 나날이 높아지고 있고, 전원 품질에 의한 경제적 피해가 늘어나면서 중요 부하 및 계통을 보호하기 위한 전력품질 보상기기 개발에 대한 연구가 활발히 진행되고 있다. 대표적인 전력품질 향상기기로는 STATCOM, DVR, SSTS 등이 있으며, 이러한 기기의 사용이 늘어나면서, 하나의 배전계통에 여러 종류의 전력품질 보상기기들이 동시에 운영될 경우, 보상기기 상호간에 미치는 영향, 그리고 대용량의 비선형 부하가 존재할 경우 보상기의 정상 동작에 미치는 영향을 함께 고려하여 보상기기의 동작 특성을 실계통에서 검증하기 위한 전력품질 실증시험장 구축이 필요하다.

  • PDF