• Title/Summary/Keyword: Statcom

Search Result 231, Processing Time 0.033 seconds

Design of the Control System for STATCOM (STATCOM용 제어시스템 개발)

  • Lee, Jong-Hak;Kim, Yun-Hyun;Kim, Tae-Hyeong;Kwon, Byung-Ki
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.534-535
    • /
    • 2013
  • 본 논문은 당사에서 개발한 5Mvar급 STATCOM(static synchronous compensator)의 제어 시스템에 대해 기술한다. 제작된 5Mvar급 STATCOM은 한 상당 12대의 HBI(H-Bridge Inverter)로 구성이 가능하도록 25-Level로 제작되었다. 제안된 제어시스템은 DSP(digital signal processor)를 이용하였으며, 하나의 Main Controller와 다수의 Cell Controller, FPGA 보드 등으로 구성되어 있다. Controller 간의 상호 정보를 교환하기 위해 eCAN 통신을 이용하였고, HBI의 스위칭을 위한 보드는 각각에 연결되어 있으며, Cell Controller보드와는 절연을 위해 광신호로 연결하였다. 본 논문에서는 개발한 제어시스템의 신뢰성을 검증하기 위한 실험을 진행하였다.

  • PDF

Special Issues - 345kV 100MVA STATCOM 국산화 개발

  • Jeong, Jeong-Ju;Jang, Byeong-Hun;Yun, Jong-Su;Han, Yeong-Seong;Park, Yong-Hui;Kim, Jun-Seong;Yu, Hyeon-Ho;Choe, Jong-Yun;Seo, In-Yeong
    • JOURNAL OF ELECTRICAL WORLD
    • /
    • s.394
    • /
    • pp.46-51
    • /
    • 2009
  • 국내 수도권 전력망의 전압 안정도 향상과 융통전력 증대로 인한 혼잡비용 저감을 위하여 한전 전력연구원과 (주)효성은 2005년부터 345kV 100MVA STATCOM을 국산화 개발하고 수도권 중추 변전소중 하나인 미금 변전소에 설치하여 실증운전을 수행하였다. 본 설비는 IGCT 전력소자를 이용하여 전압원 인버터의 고성능화, 소형화를 이룩하였으며, 설계, 제작, 설치, 운영 및 IT 기술을 이용한 운영방안의 고도화 등 제반사항을 국내 기술로 개발한데 큰 의의가 있다. 본 STATCOM은 2010년말까지 실증운전을 통한 신뢰성 검증후 2011년 본격적인 상용운전을 시작할 예정이다.

  • PDF

A Study on Voltage Stability Enhancement of Power System using the STATCOM (STATCOM을 이용한 전력계통의 전압안정도 향상방안에 관한 연구)

  • Gim, Jea-Hyeon;Kim, Yang-Il;Ki, Kyung-Hyun;Jeung, Sung-Won
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.255-258
    • /
    • 2003
  • In this paper there are different methods used to study the voltage stability, such as the P-V curve method. Jacobian method and the voltage collapse proximity indicator(L-index) method. The P-V curve method is to check operating margin from the maximum operating point. The Jacobian method is to check the eigenvalue or the minimum singular value of the load flow Jacobian matrix. If the power system is unstable, one of the eigenvalues, at least, has crossed the imaginary axis. The L-index method is to quantify how to close a particular operating point. This paper describes these methods to select the best location of FACTS and demonstrate the effectiveness of STATCOM of voltage stability on the IEEE 9-bus system.

  • PDF

The Digital Butterworth Filter of STATCOM for detecting negative sequence components of Unbalanced Load currents (불평형보상용 STATCOM의 역상분 전류 검출을 위한 디지털 버터워쓰 필터)

  • Lim, Su-Saeng;Lee, Eun-Woong;Son, Hong-Kwan;Kim, Seok-Kon;Kim, Jun-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.333-335
    • /
    • 2000
  • STATCOM(static synchronous compensator : one of the custom power equipment) can be used for balancing unbalanced loads. Compensation current references are given by the analysis of the unbalanced 3-phase currents. And for detecting negative-sequence components, a digital Butterworth Filter is designed. Finally a negative sequence component of an unbalanced load current is acquired using the digital Butterworth Filter.

  • PDF

Grid Voltage Regulation with MMC-HVDC System

  • Quach, Ngoc-Thinh;Jeong, Woo-Cheol;Yang, Hang-Jun;Choi, Jong-Yun;Kim, Eel-Hwan
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.146-147
    • /
    • 2014
  • This paper presents an operation of the modular multilevel converter-high voltage direct current (MMC-HVDC) system as a Statcom to support the grid voltage. The advantage of the MMC-HVDC system is that it can control the active and reactive powers independently. The proposed control scheme will be designed by combining this performance and the control method of the Statcom. The grid voltage is regulated by the control of the reactive power, meanwhile the active power is controlled according to its applications. The simulation results based on the PSCAD/EMTDC simulation program will evaluate the effectiveness of the control scheme.

  • PDF

DC Voltage Balancing Control for Multilevel H-Bridge STATCOM (다단 인버터 STATCOM의 직류전압 평형 제어)

  • Kim, Kyoung-Jin;Song, Seong Ho;Jeong, Seung-Gi
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.234-237
    • /
    • 2010
  • This paper proposes a balancing control of DC-link voltages of a H-bridge multilevel inverter for STATCOM application. Individual DC link voltage is controlled by simply adjusting the d-q voltage reference through a PI controller in each cell while the main controller carries out the reactive power control. The correctness and effectiveness of the method are validated by PSIM simulation with unbalanced load condition data taken from a typical arc furnace load, showing the adverse effects of load unbalance to DC link voltage significantly suppressed.

  • PDF

The analysis of KEPCO $\pm40MVA$ SSSC dynamic characteristics (FACTS Pilot Plant $\pm40MVA$ SSSC 동특성 분석)

  • Yoon Jong Su;Jeon Young Soo;Kim Soo Yeol
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.174-176
    • /
    • 2004
  • FACTS 기술은 송전계통에 전압원 인버터를 설치하여 모선 전압과 전력조류를 제어하므로 송전용량 증대 및 계통 안정도 향상을 가능케하는 신기술이다. 국내에서는 2003년 최초의 FACTS Pilot Plant인 80MVA UPFC가 154kV 강진 변전소에 설치되었다. UPFC는 STATCOM과 SSSC가 DC 커패시터를 통하여 결합된 구조로 되어 모선전압과 유효/무효전력 조류의 독립적인 제어가 가능하며 계통 운전 상황에 따라 STATCOM과 SSSC의 단독운전 또한 가능하다. 따라서 STATCOM 및 SSSC 단독운전시의 계통영향에 대한 분석이 필요하다 본 논문은 EMTDC 모델을 이용하여 현재 운전중인 강진 변전소 UPFC의 직렬 운전모드인 40MVA SSSC의 제어특성과 운전효과 분석에 대하여 기술하였다.

  • PDF

Study on Elimination of STATCOM DC Unbalance (STATCOM DC Unbalance 해소에 대한 연구)

  • Han, Young-Seong;Chung, Chung-Choo;Kim, Dae-Hee;Yoo, Hyun-Ho;Suh, In-Young;Kim, Su-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.369-370
    • /
    • 2008
  • 본 논문은 TD-PS(Time Delay-Phase Shift) 방식 다중 3-Level NPC 인버터의 출력에 포함된 미소 직류 전압 억제 및 직류버스의 정/부 콘덴서 전압의 불평형 개선 방안과 그 효과에 대하여 기술하였다.

  • PDF