• Title/Summary/Keyword: Starting Current

Search Result 633, Processing Time 0.029 seconds

Charging-Discharging Behavior and Performance of AGM Lead Acid Battery/EDLC Module for x-HEV (x-HEV용 AGM 연축전지/EDLC 통합모듈의 성능 및 충방전 거동)

  • Kim, Sung Joon;Seo, Sung Won;An, Sin Young;Kim, Bong-Gu;Son, Jeong Hun;Jung, Yeon Gil
    • Korean Journal of Materials Research
    • /
    • v.31 no.2
    • /
    • pp.84-91
    • /
    • 2021
  • To cope with automobile exhaust gas regulations, ISG and charging control systems are applied to HEV vehicles for the purpose of improving fuel economy. These systems require quick charge-discharge performance of high current. Therefore, a Module of the AGM battery with high energy density and EDLC(Electric Double Layer Capacitor) with high power density are constructed to study the charging and discharging behavior. In CCA, which evaluates the starting performance at -18 ℃ & 30 ℃ with high current, EDLC contributed for about 8 sec at the beginning. At 0 ℃ CA (Charge Acceptance), the initial Charging current of the AGM/EDLC Module, is twice that of the AGM lead acid battery. To play the role of EDLC during high-current rapid charging and discharging, the condition of the AGM lead-acid battery is optimally maintained. As a result of a Standard of Battery Association of Japan (SBA) S0101 test, the service life of the Module of the AGM Lead Acid Battery/EDLC is found to improve by 2 times compared to that of the AGM Lead Acid Battery.

Development of the Starting Algorithm and Starter for Turbo Generator (터보 제너레이터의 시동 알고리즘 및 시동기 개발)

  • 노민식;박승엽
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.1
    • /
    • pp.17-24
    • /
    • 2004
  • The starter of the turbo generator is composed of a high speed generator(HSG), an inverter and a boost converter instead of a gearbox, a DC motor and a low-voltage battery in the starter of the turbo shaft generation system. Because turbo generator is needed a high speed motoring at start-up, high speed generator has a low leakage inductance and inverter need a high DC link voltage. In this study, for developing the stater of a turbo generator, a boost converter with a high capacity was developed to convert high voltage from a low battery voltage. And for controlling a high frequency current to be injected to a motor winding with a low leakage inductance, the inverter with a high precision and a high speed operation was designed and for a stable ignition, the starting algorithm of a turbo generator was proposed. Turbo generator was started by the starter developed to verify the performances.

The copy networks controlling the copy number according to the fluctuations of the input traffics for an ATM Multicast Switch (입력 트래픽의 특성에 따라 복사 수가 제어되는 ATM 멀티캐스트 스위치 복사 망)

  • Paik, Jung-Hoon;Lim, Chae-Tak
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.10
    • /
    • pp.52-63
    • /
    • 1998
  • In this paper, several improvements to a copy network proposed previously for multicast packet switching are described. The improvements provide a solution to some problems inherent in multicasting. The input fairness problem caused by overf low is solved by a dynamic starting point decider(DSD), which can calculate running sums of copy requests starting from any input port. The starting point is changed adaptively in every time slot based on both the fill level of the input buffers in current time slot and the overflow situations of the previous time slot. Using the fill level of the conventional network. The DSD also provides the function of regulating overall copy requests according to the amount of input traffics. This is an essential function in improving overall throughputs of the copy networks. The throughput of a multicast switch can be improved substantially if partial service of copy request is implemented when overflow occurs. Call-splitting can also be implemented by the DSD in a straightforward manner. The hardware for the DSD is derived with the objective of simple architectures for the high speed operation. Simulation study of the copy network under various traffic conditions is presented to evaluate its performance.

  • PDF

A Study on the Stabilization of Generating Negative Voltage for IT Equipments using Microcontroller (마이크로컨트롤러를 이용한 IT 기기용 마이너스 전압 생성의 안정화에 관한 연구)

  • Lee, Hyun-Chang
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.6
    • /
    • pp.7-13
    • /
    • 2021
  • In this paper, the function of starting the negative voltage used in the IT equipment when it is generated and the method of controlling it using a microcontroller for the function to detect the overload and respond to it are presented. To do this, the limitations of the existing negative voltage generation circuit and the problems that occur during overload were analyzed, and a circuit that detects and controls the overload condition without a separate current sensing circuit was presented. In order to confirm the effect of the proposed method, an experiment was conducted by configuring an experimental circuit. As a result of the experiment, compared to the existing negative voltage generation circuit, which falls into a latch-up state when overloaded and enters a dangerous state, the proposed circuit detects this, stop the operation of the circuit, and informs the user of such an abnormal state to take action. have. In addition, since the starting point of the circuit is determined according to the system state, the experimental result was confirmed that the starting time was significantly shortened by about 23% compared to the time switch method.

A Study on High Efficiency Inverter Ballast Using Microprocessor (마이크로프로세서를 사용한 고효율 인버터 안정기에 관한 연구)

  • 정재륜
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.2
    • /
    • pp.88-94
    • /
    • 1999
  • This paper describes the high efficiency inverter ballast circuit using very cheap microprocessor, which has been developed by the author. A variety of soft-switching techniques have been proposed to reduce the switching losses and EMI publems that accur with higher switching frequencies in switched inverter ballast 1be inverter ballast circuit, which employs a temperature sensing circuits has been also proposed to improve starting performance of the fluorescent lamps. That is, the inverter ballast circuit, which employs a soft-starting circuits and soft-switching techniques to implement the power factoc correcticn and to mitigate of power-loss and iocrease a life time of the fluorescent lamps, has become an attractive performance forballasting the fluorescent lamps. In this paper, the operation and the control of the inverter ballast are described in detail and experimental results are presented. As the experimental results, when enviroment temperatture is at TEX>$-40^{\circ}C$, the inverter ballast circuit has low THD(4.8%) of the input current and large power factor(98%) of the lamp current. The proposed improved ballast circuit awears to be a good performance for ballasting fluorescent lamps. lamps.

  • PDF

Development of a Durable Startup Procedure for PEMFCs (고분자전해질 연료전지 내구성 향상을 위한 시동 기술 개발에 관한 연구)

  • Kim, Jae-Hong;Jo, Yoo-Yeon;Jang, Jong-Hyun;Kim, Hyung-Juhn;Lim, Tae-Hoon;Oh, In-Hwan;Cho, Eun-Ae
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.288-294
    • /
    • 2009
  • Various polymer electrolyte membrane fuel cell (PEMFC) startup procedures were tested to explore possible techniques for reducing performance decay and improving durability during repeated startup-shutdown cycles. The effects of applying a dummy load, which prevents cell reversal by consuming the air at the cathode, on the degradation of a membrane electrode assembly (MEA) were investigated via single cell experiments. The electrochemical results showed that application of a dummy load during the startup procedure significantly reduced the performance decay, the decrease in the electrochemically active surface area (EAS), and the increase in the charge transfer resistance ($R_{ct}$), which resulted in a dramatic improvement in durability. After 1200 startup-shutdown cycles, post-mortem analyses were carried out to investigate the degradation mechanisms via various physicochemical methods including FESEM, an on-line $CO_2$ analysis, EPMA, XRD, FETEM, SAED, FTIR. After 1200 startup-shutdown cycles, severe Pt particle sintering/agglomeration/dissolution and carbon corrosion were observed at the cathode catalyst layer when starting up a PEMFC without a dummy load, which significantly contributed to a loss of Pt surface area, and thus to cell performance degradation. However, applying a dummy load during the startup procedure remarkably mitigated such severe degradations, and should be used to increase the durability of MEAs in PEMFCs. Our results suggest that starting up PEMFCs while applying a dummy load is an effective method for mitigating performance degradation caused by reverse current under a repetition of unprotected startup cycles.

  • PDF

Simple Digital LCD Backlight Inverter using a Single-chip Microcontroller (단일칩 마이크로컨트롤러를 이용한 간단한 디지털 LCD 백라이트 인버터)

  • Jeong, Gang-Youl
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.2
    • /
    • pp.461-468
    • /
    • 2010
  • This paper presents a simple digital LCD backlight inverter using a single-chip microcontroller. The proposed inverter reduces the ignition voltage and eliminates the current spikes and hence improves the ignition behavior of the cold cathode fluorescent lamp(CCFL). Thus it increases the CCFL's life span. This is achieved by implementing a digital dimming control algorithm, that contains the soft-starting algorithm, all on a single-chip microcontroller. The inverter utilizes the full-bridge resonant circuit topology. The design example along with a simple analysis for the inverter is shown, and the experimental results of the designed prototype results in close agreement with the theoretical analysis and explanation. The overall system's power efficiency is approximately 85%. Compared with conventional inverters, the ignition voltage is reduced by around 30% without any lamp current spike occurring during the dimming control operation.

Novel LCD CCFL-backlight Electronic Ballast using the Phase-shift Full-bridge Inverter (위상천이 풀브리지 인버터를 이용한 새로운 LCD CCFL 백라이트 전자식 안정기)

  • Jeong, Gang-Youl
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.8-17
    • /
    • 2010
  • This paper proposes a novel LCD CCFL-backlight electronic ballast using the phase-shift full-bridge inverter. The proposed electronic ballast reduces the ignition voltage and eliminates current spikes using the new digital dimming control applied with soft-starting. Thus the electronic ballast improves ignition behavior of the CCFL and hence increases the CCFL's life span. For this, this paper analyzes the full-bridge inverter topology of the proposed electronic ballast and explains the new digital dimming control algorithm applied to the ballast, briefly. And this paper shows a design example of the prototype circuit and explains an implementation method of the digital dimming control which is implemented on a single-chip microcontroller with software. This was implemented as actual prototype electronic ballast, and its experimental results showed that the proposed electronic ballast operates correctly. The ignition voltage of the prototype in the digital dimming operation was reduced about 30[%] compared with the conventional electronic ballast and there were not any current spikes.

Initial Rotor Polarity Detection of Single-phase Permanent Magnet Synchronous Motor Based on Virtual dq-axis (단상 영구자석 동기 전동기의 가상 dq축 기반 초기 회전자 자극 검출)

  • Seo, Sung-Woo;Hwang, Seon-Hwan;Lee, Ki-Chang
    • Journal of IKEEE
    • /
    • v.24 no.4
    • /
    • pp.1004-1010
    • /
    • 2020
  • This paper proposes an initial rotor magnetic pole detection method for single-phase permanent magnet synchronous motors. The target motor cannot obtain position information based on the back emf in the low speed and stop state. Therefore, an open loop starting process is required, and in this process, initial rotor position information for low current and soft start is need. The proposed initial rotor magnetic pole detection algorithm considers the effect of asymmetric air- gap and magnetic flux. In addition, the high-frequency voltage signal injection and the offset voltage for accurate detection is used. As a result, the permanent magnet poles are is determined by acquiring the maximum value of the induced current using the virtual dq-axis.

Performances of SRM for LSEV

  • Ahn Jin-Woo;Kim Tae-Hyoung;Lee Dong-Hee
    • Journal of Power Electronics
    • /
    • v.5 no.1
    • /
    • pp.45-54
    • /
    • 2005
  • This paper presents an application of SR drives for LSEV's(Low Speed Electric Vehicles) which are used for golf and leisure. Two types of 5[HP] SRM's and its drive system are designed and tested. In order to be energy saving and have effective braking during deceleration, a multi-level inverter is proposed. For the precise switching angle control, a new type of analog encoder is proposed. A current control is adopted for soft starting and an angle control is adopted at high speed to increase efficiency. Drive characteristics and performance are shown with test results.