• Title/Summary/Keyword: Starting Current

Search Result 633, Processing Time 0.028 seconds

Permanent magnet excitation generator Voltage fluctuation suppression control method (영구자석 여자기형 발전기의 전압변동 억제 제어방식)

  • Jo, YeongJun;Kwak, YunChang;Lee, Dong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.74-75
    • /
    • 2017
  • This paper proposes a control scheme of the voltage ripple suppression for the permanent magnet exciter generator. The output voltage of the permanent magnet excitation generator is affected by the field current, load current and the engine speed. The engine speed can be controlled by the governor. But, the actual frequency is changed at the starting and a sudden load variation. As a result, output voltage overshoot and undershoot can decrease the power quality in the grid system. The proposed control scheme uses a frequency factor to control the field current of the generator for the voltage ripple reduction. Because of the linkage flux is proportional to the frequency, the instantaneous frequency can consider the linkage flux. The proposed control method shows the improved control performance for the permanent magnet excitation generator through simulation.

  • PDF

Voltage Quality Analysis in Power Distribution System with Superconducting Fault Current Limiter at Grounding Line (초전도 한류기를 주변압기 접지선에 설치시 배전계통의 순간전압품질 분석)

  • Moon, Jong-Fil
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.4
    • /
    • pp.159-163
    • /
    • 2013
  • In this paper, voltage quality improvement is analyzed in case of Superconducting Fault Current Limiter (SFCL) installed in grounding line of main transformer in power distribution system. First, a resistive-type SFCL model is used. Next, Korean power distribution system is modeled. Finally, when SFCL is installed in the starting point of feeder and grounding line of main transformer, voltage qualities are evaluated according to various fault locations and resistance values of SFCL using PSCAD/EMTDC. The voltage quality results in case of grounding line are compared with the voltage in case of feeder.

Digital Transformation in the Restaurant Industry: Current Developments and Implications

  • Alt, Rainer
    • Journal of Smart Tourism
    • /
    • v.1 no.1
    • /
    • pp.69-74
    • /
    • 2021
  • Restaurants are an important area of the hospitality industry. This industry sector has not only experienced severe consequences of the recent lockdowns, but it has also seen the rise of digital technologies. As known from other industries, the digital transformation impacts products, processes and business models alike. Starting from the classical distinction of a restaurant's front- and back-of-the-house processes, this paper presents an overview on current developments in the restaurant industry and based on an analysis of current digital services, it derives some implications for future directions. Among the observations are that restaurants need to cover more touch points, provide more individualized offerings and strive for more automation as well as integration of their systems.

Development of a Sensorless Deep Well Pump Multi-function Controller using Current Detection Method (전류검출 방식의 심정 펌프 센서리스형 다기능 컨트롤러 개발)

  • Lee, In-Jae;Basnet, Barun;Chun, Hyun-Jun;Bang, Jun-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.7
    • /
    • pp.1149-1154
    • /
    • 2017
  • In this paper, we propose a sensorless multi-function controller applicable for deep well water pumps using current detection method. The proposed system overcomes various drawbacks of existing sensored system and additional features like Over current protection function due to overload, Under current protection function for idling at low water level and Relay function for starting single phase motors and acts as a level indicator to detect water lever in real time by the current detection method. A prototype of the multi-function controller system is designed and all of its functions are tested in the laboratory. The application of the proposed controller ensures reduction in the power consumption and maintenance cost in the facilities like water and septic tanks, drainage and waste water system, oil and chemical tanks where deep well pumps are used.

A Study on Rotor Polarity Detection of SP-PMSM Using Offset Current Based on Current Control (전류 제어 기반 옵셋 전류를 이용한 단상 영구자석 동기 전동기의 회전자 자극 검출에 관한 연구)

  • Park, Jong-Won;Hwang, Seon-Hwan
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.1020-1026
    • /
    • 2019
  • In this paper, a rotor polarity detection algorithm is proposed to control the single-phase permanent magnet synchronous motors(SP-PMSMs) for high speed sensorless operation. Generally, the sensorless control of a SP-PMSM is switched to the sensorless operation in a specific speed region after the open loop startup. As a result, it is necessary to detect the rotor polarity to maintain a constant rotational direction of the SP-PMSM at the starting process. There, this paper presents a novel rotor polarity detection method using a high frequency voltage signal and offset current which is generated by current regulator. The proposed algorithm verified the effectiveness and usefulness of the rotor polarity detection through several experiments.

Characteristics of Hybrid-Type SFCL according to the Parallel Connection of Secondary Windings (2차권선의 병렬연결에 따른 하이브리드형 초전도 한류기의 특성)

  • Hwang, Jong-Sun;Cho, Yong-Sun;Choi, Hyo-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2006.10b
    • /
    • pp.208-211
    • /
    • 2006
  • We have analyzed operating characteristics of hybrid-type superconducting fault current limiter (SFCL) according to the parallel connection of secondary windings with $YBa_{2}Cu_{3}O_{7}$ (YBCO) films. The turn ratio between the primary and secondary windings of each reactor was 63:21. Hybrid-type SFCL using a transformer with parallel reactors could reduce the unbalanced quench caused by differences of the critical current density between YBCO films. We found that hybrid-type SFCL having parallel connection induced simultaneous quench between the superconducting elements. The quench-starting point at this time was almost same. When the applied voltage was 200V, the limiting current in the hybrid-type SFCL with a serial connection was lowered to 34 percent than that in the SFCL with a parallel connection. In the meantime, when the voltage generated in the superconducting elements was the same, the current value in the parallel connection was 60 percent less than in the serial connection. The voltage generated in the primary winding also showed the similar behavior. In conclusion, we found that the fault current was limited more effectively in the SFCL with the serial connection but the power burden of the superconducting elements was reduced in the parallel connection.

  • PDF

A Single-Input Single-Output Approach by using Minor-Loop Voltage Feedback Compensation with Modified SPWM Technique for Three-Phase AC-DC Buck Converter

  • Alias, Azrita;Rahim, Nasrudin Abd.;Hussain, Mohamed Azlan
    • Journal of Power Electronics
    • /
    • v.13 no.5
    • /
    • pp.829-840
    • /
    • 2013
  • The modified sinusoidal pulse-width modulation (SPWM) is one of the PWM techniques used in three-phase AC-DC buck converters. The modified SPWM works without the current sensor (the converter is current sensorless), improves production of sinusoidal AC current, enables obtainment of near-unity power factor, and controls output voltage through modulation gain (ranging from 0 to 1). The main problem of the modified SPWM is the huge starting current and voltage (during transient) that results from a large step change from the reference voltage. When the load changes, the output voltage significantly drops (through switching losses and non-ideal converter elements). The single-input single-output (SISO) approach with minor-loop voltage feedback controller presented here overcomes this problem. This approach is created on a theoretical linear model and verified by discrete-model simulation on MATLAB/Simulink. The capability and effectiveness of the SISO approach in compensating start-up current/voltage and in achieving zero steady-state error were tested for transient cases with step-changed load and step-changed reference voltage for linear and non-linear loads. Tests were done to analyze the transient performance against various controller gains. An experiment prototype was also developed for verification.

Leakage Current Waveforms and Spectrum Analysis of EPDM Polymer Insulator according to Environment Condition (환경조건에 따른 EPDM 고분자 애자의 누설전류파형과 스펙트럼 분석)

  • Park, Jae-Jun;Kim, Jeong-Boo;Song, Young-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05b
    • /
    • pp.82-86
    • /
    • 2004
  • This research is about the result of leakage current waveform about the situation of surface leakage current and environmental changes(Salt fog, clean fog and rain) by EPDM polymer insulators' amount of salt. The researcher presents the result of changing about fundamental harmonic, 3rd harmonic and 5th harmonic from starting point of supplying power to flashover. In this study, researched environmental affects (clean fog, salt fog and rain) about surface aging of polymer insulators and used frequency spectrum of leakage current waveform to develop the diagnostic technique of surface aging. When amount of salt contents changed, surface aging stage and the degree of aging (distortion factor) about 3rd and 5th harmonic waveform on low frequency harmonic wave. The distortion factor which is harmonic percentage about basic harmonic is important pointer to evaluate the surface condition of polymer insulators.

  • PDF

Characteristics of Current Patterns and Structure of Bamboo Weir in Samchunpo Water Area (삼천포 수역 죽방렴의 어구구조와 해수유동 특성)

  • 강경미;신현옥
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.38 no.1
    • /
    • pp.69-78
    • /
    • 2002
  • In order to examine the directional suitability of the axis direction of the fishing gear against the current, the experiments were carried out at the bamboo weir in Samchunpo water area from January, 2000 to September, 2001 The results of the study are as follows: In the experimental fishing gear constructed in the "V" shape, the range between two reference piles located at the entrance was 2.5m. The direction of bamboo weir′s axis was 355.5$^{\circ}$ The length of the left wing and those from the reference pile to the starting point of a curve were 106.0m, 7.5m, respectively. The length of the right wing and those from the reference pile to the starting point of a curve were 79.0m, 10.0m, respectively. Depths around the left and right stone wall that drove the steel pile were 5.0~6.5m and 6.5~9.5m, respectively. Also, depths on the bamboo weir′s axis and around the sack were 7.0~8.0m and about 8.0m, respectively. The maximum height of stone walls at the point of the left wing, the right wing and around the sack on the bamboo weir\` axis were 3.0m, 4.7m and 4.0m, respectively, Widths of stone walls at the point of both of the wings and around the sack on the bamboo weir\`s axis were 10.0~l4.0m, 22.0~25.0m, respectively. The averaging current direction on ebb tide was measured two times and it was 169.2$^{\circ}$ but the direction had about a 6.3$^{\circ}$ difference from the bamboo weirs axis. The maximum current speed appeared two to three hours later from the time of high tide and the current speed over 80.0cm/s lasted during about two Hours on the ebb tide In the case of a straight type wing In the bamboo weir, the eddy out of the left wing was comparatively big and the current on the right side from the bamboo weir′s axis had a tendency in turning to the right wing side. But in the case of a curve type wing, the eddy and tendency reduced significantly. It was thought that the experimental fishing gear was set suitably from the result of this simulation.

The Current Status of the Development of Bearing Steels (베어링강의 개발동향)

  • 유선준
    • Transactions of Materials Processing
    • /
    • v.12 no.2
    • /
    • pp.88-93
    • /
    • 2003
  • Several alloy bearing steels have been starting to replace for conventional high carbon and high chromium bearing steel since 1980. In this paper the global bearing developing trends were summarized in several important aspects- developments in alloy bearing steels for improved service life, development of inclusion rating method in bearing steel and developments in bearing service life testing.