• Title/Summary/Keyword: Standing surface

Search Result 355, Processing Time 0.027 seconds

Chemical Sensors Based on Distributed Bragg Reflector Porous Silicon Smart Particles

  • Sohn, Honglae
    • Journal of Integrative Natural Science
    • /
    • v.8 no.1
    • /
    • pp.67-74
    • /
    • 2015
  • Sensing characteristics for porous smart particle based on DBR smart particles were reported. Optically encoded porous silicon smart particles were successfully fabricated from the free-standing porous silicon thin films using ultrasono-method. DBR PSi was prepared by an electrochemical etch of heavily doped $p^{++}$-type silicon wafer. DBR PSi was prepared by using a periodic pseudo-square wave current. The surface-modified DBR PSi was prepared by either thermal oxidation or thermal hydrosilylation. Free-standing DBR PSi films were generated by lift-off from the silicon wafer substrate using an electropolishing current. Free-standing DBR PSi films were ultrasonicated to create DBR-structured porous smart particles. Three different surface-modified DBR smart particles have been prepared and used for sensing volatile organic vapors. For different types of surface-modified DBR smart particles, the shift of reflectivity mainly depends on the vapor pressure of analyte even though the surfaces of DBR smart particles are different. However huge difference in the shift of reflectivity depending on the different types of surface-modified DBR smart particles was obtained when the vapor pressures are quite similar which demonstrate a possible sensing application to specify the volatile organic vapors.

Developmental Changes of Static Standing Balance and Sensory Organization in Children (정상아동의 정적 균형과 감각통합의 발달)

  • An, Mi-Hee;Yi, Chung-Hwi
    • Physical Therapy Korea
    • /
    • v.15 no.3
    • /
    • pp.1-7
    • /
    • 2008
  • Multi-sensory systems, including the visual, somatosensory, and vestibular ones, are involved in maintaining standing balance. The organization of these sensory systems is as important as the efficiency of each individual system in maintaining optimal balance. The purpose of the present experiment was to investigate the developmental changes in static standing balance and sensory organization under altered sensory conditions. This study involved 64 children (from 4 to 15 years of age) and 17 young adults. The children were divided into four age groups: 4~6, 7~9, 10~12, and 13~15 years. Static standing balance was assessed with the one-leg standing test under four different sensory conditions: the children stood on a firm surface with (1) eyes open or (2) closed, and they stood on a foam surface with eyes (3) open or (4) closed. In balancing ability, the age groups exhibited significant differences. The function of sensory organization for balance control was poorer for the children than for the young adults. The functional efficiency of the somatosensory system of the children aged 7~9 years was at the young adults' level, and the visual function of the children aged 10~12 years had also reached the young adults' level. However, the functional efficiency of the vestibular system of children was significantly lower than that of the young adults, even at the age of 15 years. This may indicate that sensory organization and standing balance are still developing after the age of 15 years.

  • PDF

Angle-Resolved Photoemission Spectroscopy and Raman Spectroscopy Study on the Quasi-free Standing Epitaxial Graphene on the 4H SiC(0001) surface

  • Yang, Gwang-Eun;Park, Jun;Park, Byeong-Gyu;Kim, Hyeong-Do;Jo, Eun-Jin;Hwang, Chan-Yong;Kim, Won-Dong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.277-277
    • /
    • 2013
  • The epitaxial graphene on the 4H- or 6H-SiC(0001) surface has been intensively studied due to the possibility of wafer-scale growt. However the existence of interface layer (zero layer graphene) and its influence on the upper graphene layer have been considered as one of the main obstarcles for the industrial application. Among various methods tried to overcome the strong interaction with the substrate through the interface layer, it has been proved that the hydrogen intercalation successfully passivate the Si dangling bond of the substrate and can produce the quasi-free standing epitaxial graphene (QFEG) layers on the siC(0001) surface. In this study, we report the results of the angle-resolved photoemission spectroscopy (ARPES) and Raman spectroscopy for the QFEG layers produced by ex-situ and in-situ hydrogen intercalation.From the ARPES measurement, we confirmed that the Dirac points of QFEG layers exactly coincide with the Fermi level. The band structure of QFEG layer are sustainable upon thermal heating up to 1100 K and robust against the deposition of several metals andmolecular deposition. We also investigated the strain of the QFEG layers by using Raman spectroscopy measurement. From the change of the 2D peak position of graphene Raman spectrum, we found out that unlike the strong compressive strain in the normal epitaxial graphene on the SiC(0001) surface, the strain of the QFEG layer are significantly released and almost similar to that of the mechanically exfoliated graphene on the silicon oxide substrate. These results indicated that various ideas proposed for the ideal free-standing graphene can be tested based on the QFEG graphene layers grown on the SiC(0001) surface.

  • PDF

A Study of Varicose Veins in Prolonged Standing at Work (서서 일하는 작업에서의 정맥류 발생에 대한 연구)

  • Lee, Yun-Keun;Yim, Sang-Hyuk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.3
    • /
    • pp.139-146
    • /
    • 2010
  • Recent studies suggest that prolonged standing at work is associated with varicose veins (VV). The objective of this study was to analyze the differences of VV risk in terms of work types in casino dealers and hotel service workers. Symptoms of VV were evaluated using a self-reported questionnaire from 2,092 participants, and muscle fatigue in the lower legs were evaluated using surface electromyography. The shift rate of median frequency in Gastrocnemius was -30.0% among the casino dealers working in prolonged static standing posture, and - 14.3% among the casino dealers sitting during working time. After adjusting age, gender, smoking, and family history of VV, the risk ratio of VV was 3.67(95% CI 2.03-6.59) in group I (prolonged standing and occasional walking at work), 6.29(95% CI 3.48-11.35) in group II (prolonged standing, occasional walking and heavy lifting at work), and 8.07(95% CI 4.51-14.43) in groupIII(prolonged static standing at work). In conclusion, prolonged standing at work may be a work related risk factor of VV.

Effects of Lumbar Stabilization on the Trunk and Lower Limb Muscle Activity and Velocity of the Center of Pressure During Single Leg Standing

  • Cynn, Heon-Seock
    • Physical Therapy Korea
    • /
    • v.17 no.4
    • /
    • pp.1-7
    • /
    • 2010
  • The aim of this study was to investigate the effects of lumbar stabilization on both trunk and lower limb muscle activity and center of pressure (COP) in single leg standing. Surface electromyography (EMG) was used to collect muscle activity data, the mean velocity of COP was measured using a force plate, and a pressure biofeedback unit was used for lumbar stabilization training. The findings of this study are summarized as follows: 1) The EMG activity of the erector spinae decreased significantly and the activity of the rectus abdominis, internal oblique, external oblique, gluteus maximus, and gluteus medius increased significantly with lumbar stabilization single leg standing. 2) No differences in activity in the tibialis anterior, medial gastrocnemius, rectus femoris, and medial hamstrings were found with single leg standing. 3) The mean velocity of COP in the antero-posterior and medio-lateral directions in the lumbar stabilization single leg standing decreased significantly compared with the preferred single leg standing. The findings of this study therefore indicate that lumbar stabilization can facilitate the co-activation of deep stabilization and global muscles that improve postural control capability during single leg standing.

Highly Stable Photoluminescent and Magnetic Multilayers Using Nucleophilic Substitution Reaction in Organic Media

  • Jo, Jin-Han
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.262-262
    • /
    • 2010
  • We introduce a novel and efficient strategy for producing free-standing functional films via photo-crosslinking and electrostatic layer-by-layer (LbL) assembly, which can allow the buildup of hydrophilic multilayers onto hydrophobic surfaces. Hydrophobic multilayers were deposited on ionic substrates by a photo-crosslinking LbL process using photo-crosslinkable polymers. The photo-crosslinked surface was converted to an anionic surface by excess UV light irradiation. This treatment allowed also the stable adhesion between metal electrode or cationic polyelectrolyte and hydrophobic multilayers. After dissolving the ionic substrates in water, the formed free-standing films exhibited unique functionalities of inserted components within hydrophobic and/or hydrophilic multilayers.

  • PDF

Ability to Maintain Postural Control while Standing on Perturbed Surfaces (바닥면의 교란에 따른 자세균형능력의 변화)

  • Park, Sung-Ha;Lee, Seung-Won
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.31 no.4
    • /
    • pp.146-152
    • /
    • 2008
  • This study was aimed to understand the effects of perturbed floor surface on human postural stability while standing. Ten subjects were asked to stand quietly on the surface with two angles of inclination ($0^{\circ}$ and $5^{\circ}$), two contamination conditions (dry and oil-contaminated), and three commercial floor materials (ceramic tile, coated wood, and vinyl tile). During each trial, a force plate with data acquisition systems was used to collect subject's center of pressure (COP) position. Measured COPs were then converted into the length of postural sway path in both subject's anterior-posterior (AP) and medio-lateral (ML) axis. Results showed that the length of sway path in ML axis was significantly affected by the angle of inclination and the type of floor material. The sway length was increased significantly at the inclination angle of $5^{\circ}$ and on the vinyl tile, respectively. The contamination condition, however, did not significantly affect the postural sway length in both AP and ML axis. The results imply that a proper treatment of floor surface and material is critical to preserving postural balance while standing.

The Effect of Dual-Task on Standing Postural Control in Persons With Chronic Stroke (만성 뇌졸중 환자의 기립 자세조절에 이중 과제가 미치는 영향)

  • Jeon, Hye-Won;Chung, Yi-Jung
    • Physical Therapy Korea
    • /
    • v.17 no.3
    • /
    • pp.20-30
    • /
    • 2010
  • This study examined whether any changes by mental task types on postural control in chronic stroke persons. Sixteen chronic stroke persons (mean age=53.75 yr) and sixteen age-and gender-matched healthy controls (mean age=54.44 yr) took part in this study. Participants randomly performed three different tasks on the stable and unstable surfaces. The no mental task was to stand while holding a 100 g weight in each hand, the arithmetic task (mental task) was to perform a silent 1-backwards counting while standing and holding a 100 g weight in each hand, and the simple task (mental task) was to stand and hold with both hands a tray (200 g) on which a glass filled with water has been placed. Sway path and sway velocity of the center of pressure (COP) were measured to assess standing postural control by task performance using the force platform. According to the results, in stroke group, total sway path and total sway velocity of COP was significantly decreased during arithmetic and simple task compared to no mental task on the stable surface (p<.05), and sway path (anteroposterior AP, mediolateral ML) of COP, total and sway velocity (AP, ML, total) of COP was significantly decreased during arithmetic and simple task compared to no mental task on the unstable surface (p<.05). Especially, sway path (AP, total) of COP and sway velocity (AP, ML, total) of COP was significantly decreased under the simple task when compared to the arithmetic task on the unstable surface (p<.05). In healthy control group, sway path (AP, ML, total) of COP and sway velocity (AP, ML, total) of COP was significantly decreased during arithmetic and simple task compared to no mental task on the stable and unstable surface (p<.05), and sway path (AP, total) of COP and sway velocity (AP, ML, total) of COP was significantly decreased under the simple task when compared to the arithmetic task on the unstable surface (p<.05). In conclusion, the findings of this study showed that arithmetic and simple task improved standing postural control for chronic stroke patients and the type of arithmetic and simple tasks were critical factor that reduced standing postural sway in dual-task conditions. Future research should determine whether dual-task conditions, including simple task, would be effective as a training program for standing postural control of stroke patients.

Fabrication and Characterization of Optically Encoded Porous Silicon Smart Particles

  • Sohn, Honglae
    • Journal of Integrative Natural Science
    • /
    • v.7 no.4
    • /
    • pp.221-226
    • /
    • 2014
  • Optically encoded porous silicon smart particles were successfully fabricated from the free-standing porous silicon thin films using ultrasono-method. DBR PSi was prepared by an electrochemical etch of heavily doped $p^{{+}{+}}$-type silicon wafer. DBR PSi was prepared by using a periodic pseudo-square wave current. The surface-modified DBR PSi was prepared by either thermal oxidation or thermal hydrosilylation. Free-standing DBR PSi films were generated by lift-off from the silicon wafer substrate using an electropolishing current. Free-standing DBR PSi films were ultrasonicated to create DBR-structured porous smart particles. Optical characteristics of porous smart particles were measured by FT-IR spectroscopy. The surface morphology of porous smart particles was determined by FE-SEM.

Comparison of Trunk Muscle Activity during Static Standing Position and Standing Position on Therapeutic Climbing Wall (정적기립자세와 치료적 클라이밍 기립자세 시 체간근 근활성도의 비교)

  • Kim, Se-Hun;Lee, Jeong-In
    • The Journal of Korean Physical Therapy
    • /
    • v.26 no.1
    • /
    • pp.27-32
    • /
    • 2014
  • Purpose: The purpose of the study was to comparison of trunk muscle activity during static standing position and standing position on therapeutic climbing wall of adult. Methods: Study subject is arbitrarily classified into 10 of experimental group and 10 control group among 20 of adult. Trunk activity measured as rectus abdominalis, external oblique, internal oblique, erector spinae. Control group maintains that center of gravity of trunk pass the front of shoulder, pelvis, knee and ankle on stable surface with putting legs apart more than shoulder width. Experimental group had static exercise on 4 by 3 meter, 90 degree of Therapeutic climbing wall. Starting position is that putting arms and legs apart more than shoulder width. In order to compare the effect of it between the groups, independent t-test was used. Results: According to the test result, significant difference between among rectus abdominalis, erector spinae the experimental groups. And external oblique, internal oblique muscle atvity is no significant difference experimental groups between among the control groups was observed. Conclusion: Trunk muscle activation is activated to standing position on the Therapeutic Climbing Wall more than static standing position.