• 제목/요약/키워드: Standard variation

검색결과 1,552건 처리시간 0.027초

Temperature Stable Current Source Using Simple Self-Bias Circuit

  • Choi, Jin-Ho
    • Journal of information and communication convergence engineering
    • /
    • 제7권2호
    • /
    • pp.215-218
    • /
    • 2009
  • In this paper, temperature stable current and voltage references using simple CMOS bias circuit are proposed. To obtain temperature stable characteristics of bias circuit a bandgap reference concept is used in a conventional circuit. The parasitic bipolar transistors or MOS transistors having different threshold voltage are required in a bandgap reference. Thereby the chip area increase or the extra CMOS process is required compared to a standard CMOS process. The proposed reference circuit can be integrated on a single chip by a standard CMOS process without the extra CMOS process. From the simulation results, the reference current variation is less than ${\pm}$0.44% over a temperature range from - $20^{\circ}C$ to $80^{\circ}C$. And the voltage variation is from - 0.02% to 0.1%.

문서세단기 성능평가방법의 표준화에 관한 연구 (A Study on Standard of Performance Evaluation for Paper Shredder)

  • 이동규;유송민;이위로;노대호;김민호
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 추계학술대회 논문집
    • /
    • pp.122-127
    • /
    • 2004
  • The purpose of this study is to introduce the standard of the durability and evaluation method for paper shredder. The major evaluation criteria include shredding capability, shredding blade (or cutter) hardness and edge roughness, and durability. Due to the difficulties in assessing the durability directly, performance deterioration of the shredder was assessed by measuring the torque variation along with the variation in shredded chip size and load, thereby proposing the indirect method of assessing the paper shredder durability.

  • PDF

터보블로워용 헬리컬 기어의 접촉응력 해석 (Contact Stress Analysis of Helical Gear for Turbo Blower)

  • 황석철;이동형;박영철;이권희
    • 한국기계가공학회지
    • /
    • 제10권2호
    • /
    • pp.90-95
    • /
    • 2011
  • This paper presents the study on the contact stress analysis of a pair of mating helical gears for turbo blower during rotation. Turbo blowers need high speed rotation of impeller in structure and high rate gear ratio. The use of helical gear indicated that noise was an important problem when the application involves high speeds and large power transmission. An example is presented to investigate the variation of contact stress on a pair of mating gears with contact positions. The variation of contact stress during rotation is compared with the contact stress at the lowest point of single tooth contact(LPSTC) and AGMA Equation for contact stress. In this study, the gear design considering the contact stress on a pair of mating gear is more severe than that of AGMA standard.

Machine Learning Based Variation Modeling and Optimization for 3D ICs

  • Samal, Sandeep Kumar;Chen, Guoqing;Lim, Sung Kyu
    • Journal of information and communication convergence engineering
    • /
    • 제14권4호
    • /
    • pp.258-267
    • /
    • 2016
  • Three-dimensional integrated circuits (3D ICs) experience die-to-die variations in addition to the already challenging within-die variations. This adds an additional design complexity and makes variation estimation and full-chip optimization even more challenging. In this paper, we show that the industry standard on-chip variation (AOCV) tables cannot be applied directly to 3D paths that are spanning multiple dies. We develop a new machine learning-based model and methodology for an accurate variation estimation of logic paths in 3D designs. Our model makes use of key parameters extracted from existing GDSII 3D IC design and sign-off simulation database. Thus, it requires no runtime overhead when compared to AOCV analysis while achieving an average accuracy of 90% in variation evaluation. By using our model in a full-chip variation-aware 3D IC physical design flow, we obtain up to 16% improvement in critical path delay under variations, which is verified with detailed Monte Carlo simulations.

서울대기중 아질산기체의 계절별 농도변화 (Concentration and Seasonal Variation of Gaseous Nitrous Acid in Seoul Air)

  • 이용근;김종욱;이동수;백선영
    • 한국대기환경학회지
    • /
    • 제10권1호
    • /
    • pp.24-31
    • /
    • 1994
  • Hourly variation of gaseous nitrous acid( HNO$_2$) concentration in Seoul air was monitored from Jan. 11 to SeP. 12, Nitrous acid concentration was determined by DS/IC over nine months of observation, HNO$_2$ range from 0.04 ppb to 5.5 ppb. Gor-tex tube as gaseous HNO$_2$generator in this study is thought to be more convenient and reproducible device than previous generator. As a result of NaOH instead of Na$_2$ CO$_3$/NaHCO$_3$ solution as the IC eluent, we could obtain more stable baseline. The concentration of the NaOH eluent was 15 mM . The limit of detection(3$\sigma$) of the liquid- Phase and gas phase nitrous acid of this method are 1.1ng/$m\ell$ , 0.04 n $\ell$ / $\ell$, respectively. The precisions evaluated by 10 replicate analysis of standard solution and standard gas generated are $\pm$1.59, $\pm$2. 89% RSD, respectively. Due to the lack of standard material for air, direct assessment of the accuracy was not possible. This study was applied to the analysis of Seoul ambient air and their results are reported herein.

  • PDF

Variation of Energy Consumption in Barracks through Simulation by Year of Completion

  • Choi, Doo-Sung;Jeon, Hung-Chan;Cho, Kyun-Hyong;Yoo, Jeong-Seong
    • KIEAE Journal
    • /
    • 제16권1호
    • /
    • pp.21-28
    • /
    • 2016
  • Purpose: The purpose of this study is to analyze & suggest the variation of energy consumption consequent on thermal insulation performance strengthening from early 2000s when modernization of barracks began until the present targeting a large barracks. Method: To carry out this research, this study surveyed the standard of thermal insulation by year, which is being applied to a barracks by conducting literature search, and selected the standard model for a barracks. Also, this study analyzed energy consumption by year & region by performing simulation(ECO2)of the selected standard model. Result: As a result, it was analyzed that in case of a building which was completed in 2015, the energy consumption for air-conditioning & heating, lighting, and hot water supply over the year 2000 reduced by 11% on the average in central district, 10% on the average in southern district, and 17% on the average in Jeju, respectively.

여천 공업단지 봄, 가을 대기 중 휘발성 유기화합물 농도 비교 연구 (Comparative Study of Volatile Organic Compound Concentrations in the Yochon Industrial Estate during Spring and Fall)

  • 김영성;송철한
    • 한국대기환경학회지
    • /
    • 제14권2호
    • /
    • pp.153-160
    • /
    • 1998
  • The concentrations of volatile organic compounds (VOCs) in the atmosphere were measured from the Yochon Industrial Estate and compared with those from Tongkwangyang and Seoul. The first important phenomenon observed in the air of Yochon was high concentrations of alkenes and in particular, ethylene and propene. For most dominant species, their means and standard deviations were high simultaneously. Concentrations of several major aliphatic species exhibited a similar pattern of diurnal variation, however, with different species combination on each day. Concentrations of several hazardous aromatic species also exhibited a similar pattern of diurnal variation on the same day, which was different from that observed in the diurnal variation of major aliphatic species. It was interpreted that some species were intermittently released from relevant processes. It was also understood that high concentrations and variations of VOC species in Yochon were localized and not related to high average concentrations of ozone in Yochon and Tongkwangyang areas.

  • PDF

남성의 숫자음 발성에 나타난 화자변이 (Speaker Variation in Number Production by Males)

  • 양병곤
    • 음성과학
    • /
    • 제8권3호
    • /
    • pp.93-104
    • /
    • 2001
  • The author analyzed acoustic parameters of ten Korean numbers produced by ten male students using Praat. Variations of f0, F1, F2 and F3 within and between speakers were examined by determining an average and standard deviation of the parameters of each number and by comparing the acoustic values with one another. Results showed that each subject produced the numbers within a certain range of variation across time. Thus, speaker identification can be more certain using dynamic information of the acoustic parameters within each vocalic segment. Also, percent difference of within-subjects' variation to that of between-subjects can be utilized to determine which sounds would be better stimuli for speaker identification. According to the criteria, the number '2' proved the best stimulus while the number '7' was the worst. Future studies will be necessary to explore robust methods of speaker identification under noisy conditions.

  • PDF

다중경로 전파환경에서 텔레비전 이동수신시의 화상품질 열화요인 이동측정법 (A Mobile Measurement Technique of Picture Quality Impairing Factor In Mobile Television Reception under Multipath Propagation Environments)

  • Deock Ho Ha
    • 전자공학회논문지A
    • /
    • 제30A권8호
    • /
    • pp.27-33
    • /
    • 1993
  • This paper presents a mobile measurement technique of the ghost-flutter caused in mobile television reception. The ghost-flutter is caused by timing variation of the television horizontal synchronizing pulse due to frequency selective fading in a multipath propagation environment. The ghost-flutter can be detected by measuring the dynamic timing variation of horizontal synchronizing pulse. Especially, in this paper, a technique for measuring horizontal synchronizing timing fluctuations which cause the ghost-flutter is developed, using a Rubidium oscillator as a time standard with high stability.

  • PDF

Investigation of Cyclic Variations of IMEP Under Idling Operation in Spark Ignition Engines

  • Han, Sung-Bin
    • Journal of Mechanical Science and Technology
    • /
    • 제15권1호
    • /
    • pp.81-87
    • /
    • 2001
  • Cyclic variability limits the range of operating conditions of spark ignition engines, especially under lean and highly diluted operation conditions. The cyclic combustion variations can be characterized by pressure parameters, combustion related parameters, and flame-front related parameters. The coefficient of variation (COV) in indicated mean effective pressure (IMEP) defines the cyclic variability in indicated work per cycle.

  • PDF