• Title/Summary/Keyword: Standard variation

Search Result 1,555, Processing Time 0.026 seconds

A Study on the Variation of Suspended Sediment Concentration in the Reservoir due to a Rainstorm (호우발생시 저수지 유입 부유사농도의 변화특성 연구)

  • Jang, Su-Hyung;Park, Moo-Jong;Yoon, Yong-Nam
    • Journal of Korea Water Resources Association
    • /
    • v.37 no.1
    • /
    • pp.43-54
    • /
    • 2004
  • The objective of this study is to propose reservoir operation method in relation to the suspended sediment concentration due to rainstorms. Present analysis is made for the Tamjin reservoir which is under construction. For the hydrologic computations the Huff rainfall distribution, Clark unit hydrograph method and Puls reservoir routing method are used. The variation of suspended sediment concentration is calculated by 2-dimensional RMA-4 model. As a result of this study, the possible intake time from the reservoir under low frequency flood is estimated and the rainfall-ret urn period - possible intake time relationship is established, which is very important in maintaining the water quality standard when supplying water from the reservoir for different utilizationurn period- possible intake time relationship is established, which is very important in maintaining the water quality standard when supplying water from the reservoir for different utilizations.

Spray Characteristics on Impingement Angle Variation and Mixture ratio of Impinging Injectors (충돌각과 혼합비 변화에 따른 충돌형 분사기의 분무특성에 관한 연구)

  • Gang, Sin Jae;Song, Beom Geun;Song, Gi Jeong;Lee, Jeong Gyu
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.5
    • /
    • pp.72-79
    • /
    • 2003
  • Spray characteristics were investigated by impinging F-O-O-F type injector with varying the impingement angle through 15, 20 and 30 degree and the mixture ratio(O/F ratio) from 1.5 to 3.0. Experimental results show that the correlation between dispersion and impingement angle is not influenced of the mixture ratio variation, but which has influence on number density, and there is a linear correlation between dispersion and impingement angle. Velocity distribution, standard deviation and SMD of droplets are decreased as the impingement angle increases. Also, it was confirmed that the distribution of droplet size are in accordance with Rosin-Rammler and Upper-limit distribution.

Accuracy and Precision according to Optimal Preparation by Analysis of Urine Lead (뇨중 연 분석의 정확성 및 정밀성에 미치는 최적 전처리법)

  • 장봉기;정은희;박종안;손부순;이종화
    • Journal of environmental and Sanitary engineering
    • /
    • v.16 no.1
    • /
    • pp.91-101
    • /
    • 2001
  • In order to propose a optimum method increasing accuracy and reproducibility in analysis of urine lead levels, we compared matrix modifier addition method and microwave digestion method. The results were as follows ; 1. Where the concentration of $Pd(NO_3)_2$(matrix modifier) was $50mg/{\ell}$, and ashing temperature was $900^{\circ}C$, the results were optimum. In case of matrix modifier addition method, the average coefficient of variation (CV) of normal man was 24.1%, and lead worker was 7.9%. The average urine lead levels of standard were $10.42\mu{g}/{\ell}$ and $19.89\mu{g}/{\ell}$ , the accuracies compared to reference values were 97.0% and 92.6%, respectively. 2. Microwave digestion temperature($160~180^{\circ}C$), time(15~25min) and the ratio of urine/ashing acid(1:1~4:1) did not significantly affect lead absorbance and background absorbance. Therefore we set up a optimum analytical conditions as follows: temperature, $160^{\circ}C$; time, 15min; the ratio of urine/ashing acid, 4:1. after samples were digested by the above analytical conditions, lead absorbance and background absorbance was measured at $450^{\circ}C$ as ashing temperature. The average coefficient of variation (CV) of normal man was 12.4%, and lead worker was 6.2%. The average urine lead levels of standard urine were $10.66\mu{g}/{\ell}$ and $23.31\mu{g}/{\ell}$, the accuracies compared to reference values were 99.3% and 103.9%, respectively. From the results, we suggest that microwave digestion method is a more favorable method than matrix modifier addition method because of easiness to reduce organic matter, possibility to analysis at low temperature and accuracy.

  • PDF

Evaluation of Reliability of Automatic System for Measuring Sizing Degree by Basis Weight Variation of Paper (종이 평량의 차이에 따른 자동 사이즈도 측정 시스템의 신뢰성 평가)

  • Lee, Ji-Young;Kim, Chul-Hwan;Lee, Ji-Young;Nam, Hye-Gyeong;Lee, Gyeong-Sun;Jo, Hu-Seung;Park, Hyung-Hun
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.46 no.3
    • /
    • pp.11-19
    • /
    • 2014
  • Reliability of the novel automatic system capable of measuring both St$\ddot{o}$ckigt sizing degree and contact angle at a time was evaluated through the calculation of its repeatability and reproducibility based on TAPPI Standard Method T 1200. As the basis weight of paper specimen increased, the repeatability and reproducibility of the automatic system became more improved than those from Hercules sizing test and contact angle test designated on TAPPI Standard Method T 530 and T 558. The more improved repeatability and reproducibility implies that a single tester can obtain the similar results under similar test conditions in spite of repetitive testing using the automatic system, and likewise that multiple testers can respectively reproduce similar data without big variation from the same paper specimen using the automatic system. In conclusion, this study is greatly meaningful in having developed the world's first automatic system to measure both St$\ddot{o}$ckigt sizing degree and contact angle simultaneously with excellent repeatability and reproducibility.

Impact of Outliers on the Statistical Measures of the Environmental Monitoring Data in Busan Coastal Sea (이상자료가 연안 환경자료의 통계 척도에 미치는 영향)

  • Cho, Hong-Yeon;Lee, Ki-Seop;Ahn, Soon-Mo
    • Ocean and Polar Research
    • /
    • v.38 no.2
    • /
    • pp.149-159
    • /
    • 2016
  • The statistical measures of the coastal environmental data are used in a variety of statistical inferences, hypothesis tests, and data-driven modeling. If the measures are biased, then the statistical estimations and models may also be biased and this potential for bias is great when data contain some outliers defined as extraordinary large or small data values. This study aims to suggest more robust statistical measures as alternatives to more commonly used measures and to assess the performance these robust measures through a quantitative evaluation of more typical measures, such as in terms of locations, spreads, and shapes, with regard to environmental monitoring data in the Busan coastal sea. The detection of outliers within the data was carried out on the basis of Rosner's test. About 5-10% of the nutrient data were found to contain outliers based on Rosner's test. After removal (zero-weighting) of the outliers in the data sets, the relative change ratios of the mean and standard deviation between before and after outlier-removal conditions revealed the figures 13 and 33%, respectively. The variation magnitudes of skewness and kurtosis are 1.36 and 8.11 in a decreasing trend, respectively. On the other hand, the change ratios for more robust measures regarding the mean and standard deviation are 3.7-10.5%, and the variation magnitudes of robust skewness and kurtosis are about only 2-4% of the magnitude of the non-robust measures. The robust measures can be regarded as outlier-resistant statistical measures based on the relatively small changes in the scenarios before and after outlier removal conditions.

Colormap Construction and Combination Method between Colormaps (컬러맵의 생성과 컬러맵간의 결합 방법)

  • Kim, Jin-Hong;Jo, Cheol-Hyo;Kim, Du-Yeong
    • The Transactions of the Korea Information Processing Society
    • /
    • v.1 no.4
    • /
    • pp.541-550
    • /
    • 1994
  • A true color image is needed many data on the occasion of the transmission and storage. Therefore, we want to describe color image by a minority data without unreasonableness at eyesight. In this paper, it is presented 256 colormap construction method in RGB, YIQ/YUV space and common colormap expression method at merge between colormaps by reason of dissimilar original color image to display at a monitor for each other colormap at the same time. In comparison with processed result in RGB, YIQ/YUV space, it was measured by PSNR, standard variation, and edge preservation rate using sobel operator. Process time is 3second in colormap construction and 2second in merge between colormaps. In the PSNR value, RGB space has higher 0.15, 0.34 on an average than YIQ and YUV spae. Standard variation has lower in 0.15, 0.41 on an average than Yiq and YUV space. But in the data compression, YIQ/YUV space have about 1/3 compression efficiency than RGB space by reason of use to only 4bit of 8bit in color component.

  • PDF

Analytical Variability of Airborne Man-made Mineral Fibers by Phase Contrast Microscopy (위상차 현미경법에 의한 인조광물섬유 분석 변이)

  • Shin, Yong Chul;Yi, Gwang Yong;Kim, Boowook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.22 no.2
    • /
    • pp.134-139
    • /
    • 2012
  • Objectives: This study was conducted to study the analytical variability of A & B counting rules in counting using a phase contrast microscope airborne fibers collected on filters in man-made mineral or vitreous fibers (MMMFs) industries. Methods: Fibers in filters were counted using A & B rules of NIOSH Method 7400. Intra-counter and inter-counter variations by fiber type and density were obtained. The types of MMMFs analyzed were glass wool fiber, rock wool fiber, slag wool fiber, and refractory ceramic fibers. The densities of fibers classified were <20 $fibers/mm^2,$ 20 - <50 $fibers/mm^2$, 50 - <100 $fibers/mm^2,$ and ${\geq}100$ $fibers/mm^2,$ respectively. Results: Intra-counter relative standard deviations by rule A were 0.084, 0.102, 0.071 for glass wool fibers, rock wool fibers and refractory ceramic fibers, and those by rule B were 0.139, 0.120 and 0.142, respectively. Inter-counter relative standard deviations by rule A were 0.281, 0.296, 0.180 for glass wool fibers, rock wool fibers and refractory ceramic fibers, and those by rule B were 0.396, 0.337 and 0.238, respectively. Conclusions: Intra-counter variation was not different significantly among fiber types (p>0.05), but B rule variation for ceramic fibers approximately 2 times greater than corresponding A rule estimates, and intra-counter and inter-counter variations were higher in the low fiber density.

Spray Pattern Analysis for a Centrifugal Fertilizer Distributor with Two Shutter Holes (두 개의 셔터 구멍이 적용된 원심식 비료 살포기의 살포패턴 분석)

  • Hwang, Seok-Joon;Park, Jeong-Hyeon;Lee, Ju-Yeon;Kim, Ki-Duck;Shin, Beom-Soo;Nam, Ju-Seok
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.10
    • /
    • pp.8-19
    • /
    • 2019
  • In this study, the spray pattern of a centrifugal fertilizer distributor with two shutter holes was analyzed and an effective driving width that satisfies proper spray uniformity was derived. The centrifugal fertilizer distributor was mounted on a tractor with a rated power of 23.7 kW and static and dynamic spray pattern tests were performed according to the standard procedure proposed by the American Society of Agricultural and Biological Engineers Standard ASAE S341.5. The height of the fertilizer distributor was 80 cm from the ground and the PTO (power take-off) shaft speed of the tractor was fixed at 540 rpm. The fertilizer scattered in space was collected using 275 evenly spaced collectors at shutter opening ratios of 25%, 50%, 75%, and 100%. The spray pattern was analyzed via the amount of sprayed fertilizer at each collector location and the coefficient of variation was used as an indicator of spray uniformity. Using the analyzed spray pattern, the effective driving width that satisfied less than 15% of the coefficient of variation was derived for different tractor driving patterns (race track mode, back and forth mode). From the results, spray uniformity increased as the shutter opening ratio decreased. The largest effective driving width was 8 m at a shutter opening ratio of 25% for both driving patterns.

The Crucial Role of the Establishment of Computed Tomography Density Conversion Tables for Treating Brain or Head/Neck Tumors

  • Yang, Shu-Chin;Lo, Su-Hua;Shie, Li-Tsuen;Lee, Sung-Wei;Ho, Sheng-Yow
    • Progress in Medical Physics
    • /
    • v.32 no.3
    • /
    • pp.59-69
    • /
    • 2021
  • Purpose: The relationship between computed tomography (CT) number and electron density (ED) has been investigated in previous studies. However, the role of these measures for guiding cancer treatment remains unclear. Methods: The CT number was plotted against ED for different imaging protocols. The CT number was imported into ED tables for the Pinnacle treatment planning system (TPS) and was used to determine the effect on dose calculations. Conversion tables for radiation dose calculations were generated and subsequently monitored using a dosimeter to determine the effect of different CT scanning protocols and treatment sites. These tables were used to retrospectively recalculate the radiation therapy plans for 41 patients after an incorrect scanning protocol was inadvertently used. The gamma index was further used to assess the dose distribution, percentage dose difference (DD), and distance-to-agreement (DTA). Results: For densities <1.1 g/cm3, the standard deviation of the CT number was ±0.6% and the greatest variation was noted for brain protocol conditions. For densities >1.1 g/cm3, the standard deviation of the CT number was ±21.2% and the greatest variation occurred for the tube voltage and head and neck (H&N) protocol conditions. These findings suggest that the factors most affecting the CT number are the tube voltage and treatment site (brain and H&N). Gamma index analyses for the 41 retrospective clinical cases, as well as brain metastases and H&N tumors, showed gamma passing rates >90% and <90% for the passing criterion of 2%/2 and 1%/1 mm, respectively. Conclusions: The CT protocol should be carefully decided for TPS. The correct protocol should be used for the corresponding TPS based on the treatment site because this especially affects the dose distribution for brain metastases and H&N tumor recognition. Such steps could help reduce systematic errors.

Reproducibility evaluation of the use of pressure conserving abdominal compressor in lung and liver volumetric modulated arc therapy (흉복부 방사선 치료 시 압력 기반 복부압박장치 적용에 따른 치료 간 재현성 평가)

  • Park, ga yeon;Kim, joo ho;Shin, hyun kyung;Kim, min soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.71-78
    • /
    • 2021
  • Purpose: To evaluate the inter-fractional position and respiratory reproducibility of lung and liver tumors using pressure conserving type(P-type) abdominal compressor in volumetric modulated arc therapy(VMAT). Materials and methods: Six lung cancer patients and three liver cancer patients who underwent VMAT using a P-type abdominal compressor were included in this study. Cone-beam computed tomography(CBCT) images were acquired before each treatment and compared with planning CT images to evaluate the inter-fractional position reproducibility. The position variation was defined as the difference of position shift values between target matching and bone matching. 4-dimensional cone-beam computed tomography(4D CBCT) images were acquired weekly before treatment and compared with planning 4DCT images to evaluate the inter-fractional respiratory reproducibility. The respiratory variation was calculated by the magnitude of excursions by breathing. Results: The mean ± standard deviation(SD) of overall position variation values, 3D vector in the three translational directions were 1.1 ± 1.4 mm and 4.5 ± 2.8 mm for the lung and liver, respectively. The mean ± SD of respiratory variation values were 0.7 ± 3.4 mm (p = 0.195) in the lung and 3.6 ± 2.6 mm (p < 0.05) in the liver. Conclusion: The use of P-type compressor in lung and liver VMAT was effective for stable control of inter-fractional position and respiratory variation by reproduction of abdominal compression. Appropriate PTV margin must be considered in treatment planning, and image guidance before each treatment are required in order to obtain more stable reproducibility