• Title/Summary/Keyword: Standard variation

Search Result 1,555, Processing Time 0.026 seconds

A Study on the effect of JPEG recompression with the color image quality (JPEG 재 압축이 컬러 이미지 품질에 미치는 영향에 관한 연구)

  • 이성형;구철회
    • Proceedings of the Korean Printing Society Conference
    • /
    • 2000.04a
    • /
    • pp.17-24
    • /
    • 2000
  • The Joint Photographic Experts Group (JPEG) is a standara still-image compression technique, established by the International for Standardization (ISO) and International Telecommunication Standardization Sector (ITUT). The standard is intended to be utilized in the various kinds of color still imaging systems as a standard color image coding format. Because JPEG is a lossy compression, the decompressed image pixel values are nto the same as values before compression. Image of JPEG compression is often made to JPEG recompression at saving to apply JPEG compression of color image. In general, JPEG is a lossy compression and compression image is predicted to be varied image quality according to recompressed Q-factor. Various distortions of JPEG compression and JPEG recompression has been reported in previous paper. In this paper, we compress four difference color samples (photo image, gradient image, vector drawing image, text image) according to various Q-factor, and then compressed images are recompressed according to various Q-factor once again. As the results, we inspect variation of quality and file size of recompressed color image, and ensure the optimum recompression factor.

An Evaluation of Liquid Chromatography/Mass Specrometry with Atmospheric Pressure Chemical Ionizarion for the Rapid and Simultaneous Measurement of Carbamate Pesticides and Organophosphorus Pesticides

  • Kim, Byeong Ju;So, Hyeon Yeong
    • Bulletin of the Korean Chemical Society
    • /
    • v.21 no.5
    • /
    • pp.471-476
    • /
    • 2000
  • Liquid chromatography/mass spectrometry with an atmospheric pressure chemical ionization interface (LC/APCI/MS) is evaluated for the simultaneous determination of carbamate pesticides and organophosphorus pesticides in a single chromatographic analysis. APCI mass spectra of those compounds were obtrained to study their ionization characteristics. APCI provided abundant ions such as protonated molecules and characteristic fragment ions for carbamate pesticides and organophosphorus pesticides. To evaluate the feasibility of the LC/APCI/MS for a routine quantitative analysis, the linearity and repeatability of LC/APCI/MS were examined by measuring standard solution mixtures of five carbamate pesticides and four organophosphorus pesticides over the range of 1 to 100 ㎍/mL. Teh peak areas in chromatograms of characteristic ions for those compounds showed less than 3% of variation from run to run. The standard calibration curves for the nine pesticides show good linearity in the concentration range. The detection limits of the LC/APCI/MS system for those compounds range from 0.006 to 0.2 ng.

Flow Range Extension of Light Oil Flowmeter Standard System with Build-Up Technique (Build-Up 기법을 이용한 경질유 표준장치의 측정범위 확장)

  • Lim, Ki-Won;Choi, Jong-Oh
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.12 s.255
    • /
    • pp.1139-1146
    • /
    • 2006
  • Light Oil Flow Standard System(LOFSS) in Korea Research Institute of Standards and Science(KRISS) was designed for oil flowmeter calibration. In order to extend the flow range from 120 $m^3/h$ to 200 $m^3/h$, the build-up technique was applied with two positive displacement flowmeters as master flowmeter. The master flowmeters were calibrated against with LOFSS, which has 0.04 % uncertainty of flow quantity determination, then the test flowmeter is calibrated against two master flowmeters. For uncertainty analysis, the repeatability of master flowmeters, the variation of the fluid density and the pipe volume due to temperature change were scrutinized. The contribution of each uncertainty factors to the calibrator and the correlation of each factors were discussed. For investigating the feasibility of uncertainty analysis, a turbine flowmeter as a transfer package was tested with LOFSS and two reference flowmeter. The hypothesis test for both results was coincide with a 95 % significant level. This means that the uncertainty analysis procedure of the calibrator is reasonable and the extension of flow range with master meters was carry out successfully.

Liquid Chromatography-Tandem Mass Spectrometry for the Determination of Lithospermic Acid B in Rat Serum

  • Kim, Hui-Hyun;Ji, Hye-Young;Lee, Hye-Won;Kim, Youn-Chul;Sohn, Dong-Hwan;Lee , Hye-Suk
    • Archives of Pharmacal Research
    • /
    • v.27 no.12
    • /
    • pp.1202-1206
    • /
    • 2004
  • A rapid, sensitive and selective liquid chromatography-tandem mass spectrometric (LC-MS/ MS) method for the determination of lithospermic acid B (LSB) in rat serum was developed. LSB and internal standard, 7-hydroxy-3-phenyl-chromen-4-one (HPC) were extracted from rat serum with methyl-tert-butyl ether at acidic pH and analyzed on a Luna $C_8$ column with the mobile phase of acetonitrile-ammonium formate (10 mM, pH 6.5) (50:50, v/v). The analytes were detected using a negative electrospray ionization tandem mass spectrometry in the multiple- reaction-monitoring mode. The standard curve was linear $(r^2 = 0.997)$ over the concentration range of 10.0-500 ng/mL. The coefficient of variation and relative error for intra- and interassay at three QC levels were 1.1~6.2% and -10.3~-2.7%, respectively. The recovery of LSB from serum sample ranged from 73.2 to 79.5%, with that of HPC (internal standard) being 75.1 %. The lower limit of quantification for LSB was 10 ng/mL using 50 ${\mu}L$ of serum sample.

Variation of Alloying Element Distribution and Microstructure due to Microsegregation in Ni-base Superalloy GTD 111 (니켈기 초내열 합금 GTD 111에서 편석에 의한 합금원소 분포 및 미세조직 변화)

  • Choi, Baig-Gyu;Kim, In-Soo;Do, Jeong-Hyeon;Jung, Joong-Eun;Jo, Chang-Yong
    • Journal of Korea Foundry Society
    • /
    • v.35 no.6
    • /
    • pp.170-177
    • /
    • 2015
  • Segregation during solidification and homogenization during thermal exposure in GTD 111 were investigated. The microstructures of as-cast, standard heat-treated, and thermally exposed specimens were observed by SEM. A compositional analysis of each specimen was conducted by EDS. The dendrite core was enriched in W and Co, though lower levels of Ti and Ta were observed. An unexpected phase, in this case like the ${\eta}$ phase, was observed due to segregation near the ${\gamma}-{\gamma}^{\prime}$ eutectic in the standard heat-treated specimen. Segregation also induced microstructural evolution near the ${\gamma}-{\gamma}^{\prime}$ eutectic during the standard heat treatment. A quantitative analysis and microstructural observations showed that the thermal exposure at a high temperature enhanced the chemical homogeneity of the alloy.

Analysis of DA-6034, a New Flavonoid Derivative in Biological Fluids by HPLC (HPLC를 이용한 생체 시료중의 새로운 플라보노이드 유도체인 DA-6034의 분석)

  • Lee, Jong-Jin;Son, Mi-Won;Yoo, Moo-Hi;Jang, Min-Sun;Kim, Won-Bae;Lee, Kang-Chun
    • YAKHAK HOEJI
    • /
    • v.42 no.2
    • /
    • pp.149-152
    • /
    • 1998
  • A high performance liquid chromatographic method was developed for the determination of DA-6034 in biological fluids using internal standard. Plasma containing DA-6034 and inter nal standard was extracted by liquid-liquid extraction at an acidic pH. After evaporation of the organic layer, the drug and internal standard were reconstituted with mobile phase and injected into the column. They were separated by high performance liquid chromatography on inertsil ODS II column at 334 nm. The detection limit of DA-6034 in plasma was 0.02 ${\mu}$g/ml. In this method, the range of recovery and coefficients of variation were 96-110% and 0.40-3.78%, respectively. There was no interference from endogenous substances. Urine and bile were analysed using the deproteinization method and the detection limit of DA-6034 was 1${\mu}$g/l.

  • PDF

SgrA* 22/43GHz KaVA observation and its Amplitude Calibration

  • CHO, ILJE;JUNG, TAEHYUN;ZHAO, GUANG-YAO;KINO, MOTOKI;SOHN, BONGWON
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.1
    • /
    • pp.73.2-73.2
    • /
    • 2016
  • We present the results of KaVA SgrA* observation together with Takahagi(32m), Yamaguchi(32m) and Nobeyama(45m) telescopes at 22 and 43GHz, respectively. In early 2014, G2 cloud was expected to encounter with SgrA* and to make a significant flux variation, but it has not been measured yet. So it's worth to check our amplitude calibration method to confirm if we have a missing flux caused by uncertainty in measuring it. We have tested both a standard method using system noise temperature(Tsys) with antenna gain information, and a template method in order to calibrate antenna gain using nearby maser source. As a result, we found that the latter method is useful for antennas which have inaccurate gain information or poor Tsys measurements, and is especially effective for sources at low elevation like SgrA*. In addition, the comparison shows that the amplitude calibration by standard method can be improved up to 10% with a correction factor using a template method. This result implies we can get more accurate flux from a standard method when any maser source not exists around target.

  • PDF

The Concentration Variation of Volatile Organic Compounds before and after Renovation in Apartment Houses (아파트 개조 전후의 휘발성유기화합물 농도변화 실태)

  • Choi, Yoon-Jung;Shim, Hyun-Suk;Shin, Hae-Chul
    • Journal of the Korean housing association
    • /
    • v.18 no.4
    • /
    • pp.59-67
    • /
    • 2007
  • The purposes of this study were to make clear the present condition of the TVOC and HCHO concentration after renovation in apartment houses. The field measurements of TVOC and HCHO concentration according to the Korea Test Method Standard for Indoor Air Quality were carried out in 4 subject apartment houses. The results are as follows; the TVOC concentration after renovation in apartment houses ranged from mean 0.35ppm to mean 5.08ppm and increased of $0.35{\sim}5.08ppm$. The TVOC concentration of 3 subjects exceeded the Indoor Air Quality Management standard for the newly-built apartment houses (0.58ppm). The HCHO concentration after renovation ranged from mean 0.13ppm to mean 0.43ppm and increased of $0.06{\sim}0.26ppm$. The HCHO concentration of 2 subjects exceeded the Standard (0.17ppm). As results of analysis on the relation of concentrated ascension and renovation elements, the amount and the types of finishing materials and adhesives affected concentrated ascension. Also, production method for installed or purchased furniture had certain effect on the TVOC and HCHO concentration ascension.

Accelerometer Signal Processing for User Activity Detection (사용자 운동 상태 추정을 위한 가속도센서 신호처리 기술)

  • 백종훈;이기혁
    • Proceedings of the IEEK Conference
    • /
    • 2003.07d
    • /
    • pp.1279-1282
    • /
    • 2003
  • Estimation of human motion states is important enabling technologies for realizing a pervasive computing environment. In this paper, an improved method fur estimating human motion state from accelerometer data is introduced. Our method fur estimating human motion state utilizes various statistics of accelerometer data, such as mean, standard variation, skewness, kurtosis, eccentricity, as features for classification, and therefore is expected to be more robust than other existing methods that rely on only a few simple statistics. A series of experiments fur testing the effectiveness of the proposed method has been performed, and its result is presented.

  • PDF

The influence of outside temperature upon shading effect in greenhouses (외기온이 온실의 차광효과에 미치는 영향)

  • 이석건;이종원;이현우
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.243-249
    • /
    • 1998
  • This study was conducted for analyzing the influence of outside temperature upon shading effect of greenhouses by simulation. The simulation program was tested by comparing predicted values to measured values and applied the Korean standard wide span glasshouse. The shading effect according to the variation of outside temperature was different by shading method and rate. The increasing rate of inside temperature with different shading rate was nearly propotional to the increasing value of outside temperature. The outside shading effect was a little better than inside shading.

  • PDF