• 제목/요약/키워드: Standard variation

검색결과 1,555건 처리시간 0.032초

Heterogeneity in liver histopathology is associated with GSK-3β activity and mitochondrial dysfunction in end-stage diabetic rats on differential diets

  • Lee, Jun-Ho;Choi, Soo-Bong;Sung, Dong-Jun;Jin, Mingli;Lee, Ju-Han;Mun, Ji-Young;Hwang, Tae-Sook;Han, Sang-Don;Ro, Young-Tae;Kim, Sung-Young;You, Jueng-Soo;Lim, Inja;Noh, Yun-Hee
    • BMB Reports
    • /
    • 제53권2호
    • /
    • pp.100-105
    • /
    • 2020
  • While liver histopathology is heterogeneous in diabetes, the underlying mechanisms remain unclear. We investigated whether glycemic variation resulting from differential diets can induce heterogeneity in diabetic liver and the underlying molecular mechanisms. We generated end-stage non-obese diabetic model rats by subtotal-pancreatectomy in male Sprague-Dawley rats and ad libitum diet for 7 weeks (n = 33). The rats were then divided into three groups, and fed a standard- or a low-protein diet (18 or 6 kcal%, respectively), for another 7 weeks: to maintain hyperglycemia, 11 rats were fed ad libitum (18AL group); to achieve euglycemia, 11 were calorie-restricted (18R group), and 11 were both calorie- and protein-restricted with the low-protein diet (6R group). Overnight-fasted liver samples were collected after the differential diets together with sham-control (18S group), and histology and molecular changes were compared. Hyperglycemic-18AL showed glycogenic hepatopathy (GH) without steatosis, with the highest GSK-3β inactivation because of Akt activation during hyperglycemia; mitochondrial function was not impaired, compared to the 18S group. Euglycemic-18R showed neither GH nor steatosis, with intermediate GSK-3β activation and mitochondrial dysfunction. However, euglycemic-6R showed both GH and steatosis despite the highest GSK-3β activity and no molecular evidence of increased lipogenesis or decreased ApoB expression, where mitochondrial dysfunction was highest among the groups. In conclusion, heterogeneous liver histopathology developed in end-stage non-obese diabetic rats as the glycemic levels varied with differential diets, in which protein content in the diets as well as glycemic levels differentially influenced GSK-3β activity and mitochondrial function in insulin-deficient state.

개인통신망 설계를 위한 최소 비용 경로 (Minimum Cost Path for Private Network Design)

  • 최홍식;이주영
    • 한국정보과학회논문지:시스템및이론
    • /
    • 제26권11호
    • /
    • pp.1373-1381
    • /
    • 1999
  • 이 논문에서는 통신망 설계 응용분야의 문제를 그래프 이론 문제로써 고려해 보았다. 개별 기업체가 서로 떨어진 두 곳을 연결하고자 할 때 공용통신망의 회선을 빌려 통신망을 구축하게 되는데 많은 경우 여러 종류의 회선들이 공급됨으로 어떤 회선을 선택하느냐의 문제가 생긴다. 일반적으로 빠른 회선(low delay)은 느린 회선(high delay)에 비해 비싸다. 그러나 서비스의 질(Quality of Service)이라는 요구사항이 종종 종단지연(end-to-end delay)시간에 의해 결정되므로, 무조건 낮은 가격의 회선만을 사용할 수는 없다. 결국 개별 기업체의 통신망을 위한 통로를 공용 통신망 위에 덮어씌워(overlaying) 구축하는 것의 여부는 두 개의 상반된 인자인 가격과 속도의 조절에 달려 있다. 따라서 일반적인 최소경로 찾기의 변형이라 할 수 있는 다음의 문제가 본 논문의 관심사이다. 두 개의 지점을 연결하는데 종단지연시간의 한계를 만족하면서 최소경비를 갖는 경로에 대한 해결을 위하여, 그래프 채색(coloring) 문제와 최단경로문제를 함께 포함하는 그래프 이론의 문제로 정형화시켜 살펴본다. 배낭문제로의 변환을 통해 이 문제는 {{{{NP-complete임을 증명하였고 {{{{O($\mid$E$\mid$D_0 )시간에 최적값을 주는 의사선형 알고리즘과O($\mid$E$\mid$)시간의 근사 알고리즘을 보였다. 특별한 경우에 대한 {{{{O($\mid$V$\mid$ + $\mid$E$\mid$)시간과 {{{{O($\mid$E$\mid$^2 + $\mid$E$\mid$$\mid$V$\mid$log$\mid$V$\mid$)시간 알고리즘을 보였으며 배낭 문제의 해결책과 유사한 그리디 휴리스틱(greedy heuristic) 알고리즘이 그물 구조(mesh) 그래프 상에서 좋은 결과를 보여주고 있음을 실험을 통해 확인해 보았다.Abstract This paper considers a graph-theoretic problem motivated by a telecommunication network optimization. When a private organization wishes to connect two sites by leasing physical lines from a public telecommunications network, it is often the cases that several categories of lines are available, at different costs. Typically a faster (low delay) lines costs more than a slower (high delay) line. However, low cost lines cannot be used exclusively because the Quality of Service (QoS) requirements often impose a bound on the end-to-end delay. Therefore, overlaying a path on the public network involves two diametrically opposing factors: cost and delay. The following variation of the standard shortest path problem is thus of interest: the shortest route between the two sites that meets a given bound on the end-to-end delay. For this problem we formulate a graph-theoretical problem that has both a shortest path component as well as coloring component. Interestingly, the problem could be formulated as a knapsack problem. We have shown that the general problem is NP-complete. The optimal polynomial-time algorithms for some special cases and one heuristic algorithm for the general problem are described.

BIO-RAD 정도관리 물질을 이용한 방사면역측정법의 Acceptable Range 설정에 대한 제언 (Radioimmunoassay Using Quality Control Materials BIO-RAD of the Suggestions for Setting Acceptable Range)

  • 박희원;김태훈;노경운;김현주
    • 핵의학기술
    • /
    • 제16권1호
    • /
    • pp.108-114
    • /
    • 2012
  • 면역측정법을 이용하는 검사실에서 가장 많이 사용하고 있는 상업용 제3자 정도관리물질이 BIO-RAD사에서 제공하는 물질이다. 현재 BIO-RAD 정도관리 물질에 포함된 Reference Sheet에는 비방사면역측정을 이용한 검사방법과 검사장비별로 각 측정물질의 Acceptable Range가 기재되어 있다. 그러나 방사면역측정법을 이용하여 검사하는 측정kit나 기기에 대해서는 실무에 적용할 만한 Acceptable Range에 대한 언급이 다소 부족한 것이 현실이다. 방사면역측정검사에 대한 Acceptable Range를 설정하여 검사결과의 객관성을 높이고 누적된 데이터를 제조사에 권고하여 발행되는 Reference Sheet에 기재하고자 한다. 본원에서는 2009년부터 부분적으로 BIO-RAD 정도관리 물질을 사용하여 2011년에는 일부 특정 항목을 제외한 대부분의 검사종목에 BIO-RAD 제 3자 정도관리물질을 사용하고 있다. 따라서 측정된 내부정도관리 데이터를 BIO-RAD사의 Unity Real Time program (version 1.0.9.27)을 이용하여 Acceptable Range를 설정하였다. BIO-RAD 정도관리 물질을 사용하는 약 50가지 검사종목의 20개 Point Data의 평균값, 표준편차, 변이계수를 구하여 측정kit별 Acceptable Range를 산출하였으며, 자동화 면역 측정기기인 Roche Elecsys/ E170/ cobas e Systems의 측정값과 비교하였다. 현재 시행하고 있는 외부정도관리 프로그램과 같이 BIO-RAD 정도관리 물질을 공통으로 사용하는 병원과 peer group을 설정하여 측정 kit별, 기기별 Acceptable Range를 제조사에 권고하여 Reference Sheet에 방사면역검사실에 적합한 Acceptable Range를 기재하여 검사결과의 객관성을 높이고 국내외적으로 방사면역측정법에 대한 인지도를 높이고자 한다.

  • PDF

가스 하이드레이트 부존층의 구조파악을 위한 탄성파 AVO 분석 AVO모델링, AVO역산 (Seismic AVO Analysis, AVO Modeling, AVO Inversion for understanding the gas-hydrate structure)

  • 김건득;정부흥
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.643-646
    • /
    • 2005
  • The gas hydrate exploration using seismic reflection data, the detection of BSR(Bottom Simulating Reflector) on the seismic section is the most important work flow because the BSR have been interpreted as being formed at the base of a gas hydrate zone. Usually, BSR has some dominant qualitative characteristics on seismic section i.e. Wavelet phase reversal compare to sea bottom signal, Parallel layer with sea bottom, Strong amplitude, Masking phenomenon above the BSR, Cross bedding with other geological layer. Even though a BSR can be selected on seismic section with these guidance, it is not enough to conform as being true BSR. Some other available methods for verifying the BSR with reliable analysis quantitatively i.e. Interval velocity analysis, AVO(Amplitude Variation with Offset)analysis etc. Usually, AVO analysis can be divided by three main parts. The first part is AVO analysis, the second is AVO modeling and the last is AVO inversion. AVO analysis is unique method for detecting the free gas zone on seismic section directly. Therefore it can be a kind of useful analysis method for discriminating true BSR, which might arise from an Possion ratio contrast between high velocity layer, partially hydrated sediment and low velocity layer, water saturated gas sediment. During the AVO interpretation, as the AVO response can be changed depend upon the water saturation ratio, it is confused to discriminate the AVO response of gas layer from dry layer. In that case, the AVO modeling is necessary to generate synthetic seismogram comparing with real data. It can be available to make conclusions from correspondence or lack of correspondence between the two seismograms. AVO inversion process is the method for driving a geological model by iterative operation that the result ing synthetic seismogram matches to real data seismogram wi thin some tolerance level. AVO inversion is a topic of current research and for now there is no general consensus on how the process should be done or even whether is valid for standard seismic data. Unfortunately, there are no well log data acquired from gas hydrate exploration area in Korea. Instead of that data, well log data and seismic data acquired from gas sand area located nearby the gas hydrate exploration area is used to AVO analysis, As the results of AVO modeling, type III AVO anomaly confirmed on the gas sand layer. The Castagna's equation constant value for estimating the S-wave velocity are evaluated as A=0.86190, B=-3845.14431 respectively and water saturation ratio is $50\%$. To calculate the reflection coefficient of synthetic seismogram, the Zoeppritz equation is used. For AVO inversion process, the dataset provided by Hampson-Rushell CO. is used.

  • PDF

Backpropagation 인공신경망을 이용한 지하 방사성폐기물 처분장 설계 인자의 민감도 분석 (A Sensitivity Analysis of Design Parameters of an Underground Radioactive Waste Repository Using a Backpropagation Neural Network)

  • 권상기;조원진
    • 터널과지하공간
    • /
    • 제19권3호
    • /
    • pp.203-212
    • /
    • 2009
  • 지하고준위 방사성폐기물 처분장 근계영역에서의 거동을 예측하는 것은 처분장 설계나 안전성 평가에 중요하다. 본 연구에서는 3차원 유한차분 코드를 이용하여 처분장 설계인자 및 재료물성으로 구성되는 7가지 인자에 대한 민감도 분석을 실시하였다. 민감도 분석 결과 처분공 간격, 터널 간격, 냉각시간과 암반의 열전도도가 다른 인자에 비해 영향이 큰 것으로 나타났다. 처분장 주변의 암반과 완충재 온도의 통계적인 분포를 구하기 위해 backpropagation 인공신경망 기법이 적용되었다. 학습된 인공신경망의 적합성을 평가하기 위해 무작위로 선정된 입력 인자에 대한 예측이 실시되었다. 인자 값의 변화가 ${\pm}10%$ 인 경우, 신경망은 1% 오차로 신뢰할 수 있는 예측 결과를 보임을 알 수 있었다. 이렇게 학습된 신경망은 다양한 경우에 대한 신속한 온도 예측에 활용할 수 있었다. 완충재와 암반의 온도는 각각 평균 $98^{\circ}C$, $83.9^{\circ}C$ 표준편차는 $3.82^{\circ}C$$3.67^{\circ}C$로 나타났다. 인공신경망을 이용함으로써 암반과 완충재 온도를 $1^{\circ}C$ 변화시키기 위해 필요한 설계 인자의 조정 범위를 추정할 수 있었다.

ESTIMATION OF CLEAR WOOD PROPERTIES BY NEAR INFRARED SPECTROSCOPY

  • Schimleck, Laurence R.;Evans, Robert;Ilic, Jugo;Matheson, A.Colin
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1161-1161
    • /
    • 2001
  • Rapid cost-effective methods of measuring wood quality are extremely important to tree improvement programs where it is necessary to test large numbers of trees. Non-destructive sampling of a forest can be achieved by using increment cores generally removed at breast height. At CSIRO Forestry and Forest Products methods for the rapid, non-destructive measurement of wood properties and wood chemistry based on increment core samples have been developed. In this paper the application of near infrared (NIR) spectroscopy to the prediction of a range solid wood properties, including density, longitudinal modulus of elasticity (E$\sub$L/) and microfibril angle (MFA), is described. Experiments conducted on individual species (Eucalyptus delegatensis and Pinus radiata), the two species combined and a number of mixed species from several genera are reported. NIR spectra were obtained from the radial/longitudinal face of each sample and used to develop calibrations for the measured physical properties. When the individual species were used the relationships between laboratory determined data and NIR fitted data were good in all cases. Coefficients of determination (R$^2$) ranging from 0.77 for MFA to 0.93 for stick density were obtained for E. delegatensis and R$^2$ ranging from 0.68 for MFA to 0.94 for strip density were obtained for P. radiata. The calibration statistics for the combined E. delegatensis and P. radiata samples were similar to those found for the individual species. As these results indicated that it might be possible to produce general calibrations based on samples from a number of species of a single genus or samples from a number of different genera, a wide range of species was subsequently tested. Good relationships were obtained for both density and E$\sub$L/. These calibrations had R$^2$ that were slightly lower than those determined using individual species and standard errors that were higher. The mixed species calibrations, when applied to the E. delegatensis and P. radiata sample sets, provided good estimates of density (stick and strip) and E$\sub$L/. The results demonstrated that a mixed species calibration, that encompasses wide variation in terms of, wood anatomy, chemistry and physical properties, could be used to rank trees. Experiments reported in this paper demonstrate that solid wood properties can be estimated by NIR spectroscopy. The method offers a rapid and non-destructive alternative to traditional methods of analysis and is applicable to large-scale non-destructive forest resource assessment, and to tree breeding and silvicultural programs.

  • PDF

NIR-TECHNOLOGY FOR RATIONALE SOIL ANALYSIS WITH IMPLICATIONS FOR PRECISION AGRICULTURE

  • Stenberg, Bo
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1061-1061
    • /
    • 2001
  • The scope of precision agriculture is to reach the put up cultivation goals by adjusting inputs as precise as possible after what is required by the soil and crop potentials, on a high spatial resolution. Consequently, precision agriculture is also often called site specific agriculture. Regulation of field inputs “on the run” has been made possible by the GPS (Geographical Position System)-technology, which gives the farmer his exact real time positioning in the field. The general goal with precision agriculture is to apply inputs where they best fill their purpose. Thus, resources could be saved, and nutrient losses as well as the impact on the environment could be minimized without lowering total yields or putting product quality at risk. As already indicated the technology exists to regulate the input based on beforehand decisions. However, the real challenge is to provide a reliable basis for decision-making. To support high spatial resolution, extensive sampling and analysis is required for many soil and plant characteristics. The potential of the NIR-technology to provide rapid, low cost analyses with a minimum of sample preparation for a multitude of characteristics therefore constitutes a far to irresistible opportunity to be un-scrutinized. In our work we have concentrated on soil-analysis. The instrument we have used is a Bran Lubbe InfraAlyzer 500 (1300-2500 nm). Clay- and organic matter-contents are soil constituents with major implications for most properties and processes in the soil system. For these constituents we had a 3000-sample material provided. High performance models for the agricultural areas in Sweden have been constructed for clay-content, but a rather large reference material is required, probably due to the large variability of Swedish soils. By subdividing Sweden into six areas the total performance was improved. Unfortunately organic matter was not as easy to get at. Reliable models for larger areas could not be constructed. However, through keeping the mineral fraction of the soil at minimal variation good performance could be achieved locally. The influence of a highly variable mineral fraction is probably one of the reasons for the contradictory results found in the literature regarding organic matter content. Tentative studies have also been performed to elucidate the potential performance in contexts with direct operational implications: lime requirement and prediction of plant uptake of soil nitrogen. In both cases there is no definite reference method, but there are numerous indirect, or indicator, methods suggested. In our study, field experiments where used as references and NIR was compared with methods normally used in Sweden. The NIR-models performed equally or slightly better as the standard methods in both situations. However, whether this is good enough is open for evaluation.

  • PDF

ADVANTAGES OF USING ARTIFICIAL NEURAL NETWORKS CALIBRATION TECHNIQUES TO NEAR-INFRARED AGRICULTURAL DATA

  • Buchmann, Nils-Bo;Ian A.Cowe
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1032-1032
    • /
    • 2001
  • Artificial Neural Network (ANN) calibration techniques have been used commercially for agricultural applications since the mid-nineties. Global models, based on transmission data from 850 to 1050 nm, are used routinely to measure protein and moisture in wheat and barley and also moisture in triticale, rye, and oats. These models are currently used commercially in approx. 15 countries throughout the world. Results concerning earlier European ANN models are being published elsewhere. Some of the findings from that study will be discussed here. ANN models have also been developed for coarsely ground samples of compound feed and feed ingredients, again measured in transmission mode from 850 to 1050 nm. The performance of models for pig- and poultry feed will be discussed briefly. These models were developed from a very large data set (more than 20,000 records), and cover a very broad range of finished products. The prediction curves are linear over the entire range for protein, fat moisture, fibre, and starch (measured only on poultry feed), and accuracy is in line with the performance of smaller models based on Partial Least Squares (PLS). A simple bias adjustment is sufficient for calibration transfer across instruments. Recently, we have investigated the possible use of ANN for a different type of NIR spectrometer, based on reflectance data from 1100 to 2500 nm. In one study, based on data for protein, fat, and moisture measured on unground compound feed samples, dedicated ANN models for specific product classes (cattle feed, pig feed, broiler feed, and layers feed) gave moderately better Standard Errors of Prediction (SEP) compared to modified PLS (MPLS). However, if the four product classes were combined into one general calibration model, the performance of the ANN model deteriorated only slightly compared to the class-specific models, while the SEP values for the MPLS predictions doubled. Brix value in molasses is a measure of sugar content. Even with a huge dataset, PLS models were not sufficiently accurate for commercial use. In contrast an ANN model based on the same data improved the accuracy considerably and straightened out non-linearity in the prediction plot. The work of Mr. David Funk (GIPSA, U. S. Department of Agriculture) who has studied the influence of various types of spectral distortions on ANN- and PLS models, thereby providing comparative information on the robustness of these models towards instrument differences, will be discussed. This study was based on data from different classes of North American wheat measured in transmission from 850 to 1050 nm. The distortions studied included the effect of absorbance offset pathlength variation, presence of stray light bandwidth, and wavelength stretch and offset (either individually or combined). It was shown that a global ANN model was much less sensitive to most perturbations than class-specific GIPSA PLS calibrations. It is concluded that ANN models based on large data sets offer substantial advantages over PLS models with respect to accuracy, range of materials that can be handled by a single calibration, stability, transferability, and sensitivity to perturbations.

  • PDF

저장 배에서 분리한 Penicillium속의 배양적 특성과 RAPD에 의한 유연관계 분석 (Analysis of Genetic Relationship and Cultural Characteristics of Penicillium species Isolated from Postharvest Decay of Pear by Random Amplified Polymorphic DNA)

  • 김주희;이왕휴;유영진;정성수;최정식
    • 한국균학회지
    • /
    • 제30권2호
    • /
    • pp.78-85
    • /
    • 2002
  • 저장배에서 분리한 15그룹 3종을 KCTC, KCCM, 충남대에서 분양받은 16균주를 대상으로 상호 유연관계를 분석하고자 배양적 특성을 관찰하고 RAPD 검정에 의한 진단 가능성을 검토하였다. 병원균의 배양특성을 조사한 결과 배지상 생육형태, 색, 속도 등에 있어서 균주간 차이를 보였으며 배양적 특성과 RAPD에 의한 유연관계 분석 결과를 비교 분석하기 위하여 배에서 분리한 15개 균주와 16개 표준 균주의 종간 다형성을 관찰하였다. RAPD을 이용하여 유전적 다양성을 분석하기 위하여 5개의 URP primer를 이용하여 genomic DNA를 증폭시킨 결과 $0.1{\sim}2.0kb$ 크기의 총 744개 band들이 증폭되었다. cluster 분석결과 전체 유사도는 47.7%로 31 균주들은 4개의 genomic DNA RAPD 집단으로 분류되었다. 배에서 분리한 P. expansum 균주간에는 87.4% 이상의 상동성을 보였고, P. solitum 균주간에는 97.5%, P. crustosum 균주 간에는 95.1% 이상의 상동성을 보였다. 배에서 분리된 동일한 종내에서는 배양적 특성에 의한 동정결과와 RAPD에 의한 분석결과와 일치하였다.

절대 위상중심변화 적용이 국내 GPS 망 자료처리에 미치는 영향분석 (AN ANALYSIS OF THE EFFECT ON THE DATA PROCESSING OF KOREA GPS NETWORK BY THE ABSOLUTE PHASE CENTER VARIATIONS OF GPS ANTENNA)

  • 백정호;임형철;조중현;조성기;조정호
    • Journal of Astronomy and Space Sciences
    • /
    • 제23권4호
    • /
    • pp.385-396
    • /
    • 2006
  • GPS 안테나 절대 PCV를 이용한 결과가 가지고 있는 지구 축척문제가 GPS 위성 안테나의 PCV 추정을 통해 해결되면서, IGS는 기존에 사용해오던 상대 PCV에서 절대 PCV로의 전환을 준비하고 있다. 이에 따라 전 세계 모든 GPS 고정밀 자료처리는 절대 PCV를 사용하여 수행될 예정이다. 그러므로 향후 국내 GPS 관측망 자료처리의 일관성과 안정성 확보를 위해 기존의 상대 PCV를 이용한 자료처리 결과와 절대 PCV를 적용한 결과를 비교 분석할 필요가 있다. 이 논문에서는 절대 PCV의 사용이 GPS 정밀측위에 미치는 영향을 GPS 망 자료처리를 통해 분석하였다. 기선의 길이와 안테나 레이돔의 영향을 알아보기 위해 1000km이상의 기선을 갖도록 IGS 기준국인 중국의 베이징, 우한과 우리나라의 대전, 수원을 사용하여 GPS 망을 구성하고 자료처리를 수행하였다. 기선의 길이가 1000km 이상인 경우 평균 1.33cm의 수직방향 차이를 보였고, 여기에 레이돔을 고려했을 경우 평균 2.97cm의 차이를 보였다. 절대 PCV적용이 국내 GPS망 자료처리에 미치는 영향을 시험하기 위해 한국천문연구원의 상시관측소 9개 중 데이터 품질이 종은 7개의 관측소에 대해 상대 PCV와 절대 PCV를 각각 적용한 결과를 서로 비교 분석하였다. 수직방향의 차이는 평균 0.12cm로써 국내 지역망에서는 그 효과가 크지 않음을 확인하였다.