• Title/Summary/Keyword: Standard variation

Search Result 1,558, Processing Time 0.029 seconds

Distribution Characteristics of the Concentration of Ambient PM-10 and PM-2.5 in Daegu Area (대구지역 대기 중 PM-10과 PM-2.5의 농도분포 특성)

  • Do, Hwa-Seok;Choi, Su-Jin;Park, Min-Sook;Lim, Jong-Ki;Kwon, Jong-Dae;Kim, Eun-Kyung;Song, Hee-Bong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.1
    • /
    • pp.20-28
    • /
    • 2014
  • The three air quality monitoring sites, analysed simultaneously PM-10 and PM-2.5, ie. Ihyeondong in industrial area, Manchondong in residential area, Pyeongnidong in streetside, among 13 air quality monitoring sites in Daegu area, were investigated the concentration distribution characteristics of PM-2.5 and PM-10 in the last 2 years (2011~2012). PM-10 concentrations exceeded annual average reference value ($50{\mu}g/m^3$) in Ihyeondong ($52.5{\mu}g/m^3$) and Pyeongnidong ($60.9{\mu}g/m^3$) but satisfied in Manchondong ($44.9{\mu}g/m^3$). All PM-2.5 concentrations exceeded EPA annual standard value of the United States ($15{\mu}g/m^3$) in three points, but also exceeded new control annual standard value ($25{\mu}g/m^3$) coming into effect in 2015. Seasonal concentration of PM-10 appeared the order of spring > winter > fall > summer, and in the case of PM-2.5, the order was winter > spring > fall > summer. Monthly concentrations of PM-10 and PM-2.5 were highest in February and lowest in September. Diurnal concentrations of PM-10 and PM-2.5 increased from 7:00 AM, and recorded the highest concentration between 10:00 AM and 11:00 AM. And after 6:00 PM it lowered continuously and tended to show fixed concentrations from evening until early morning. In addition, the concentration of fine particles during the week was higher than the weekend. The fluctuation in industrial area was larger than the residential area. At the PM-2.5/PM-10 ratio, summer was generally high, spring was the lowest. And, when yellow sand occurred, it was 0.32 to 0.42. It was very low compared to 0.54 to 0.64 during non-yellow sand times. This paper for the state and the characteristics of Daegu' fine particles (PM-10, PM-2.5) will be valuable to future researches of fine particles and air pollution management.

Reproducibility of Applicator Position with High dose rate brachytherapy in uterine cervical cancer (자궁경부암 환자의 근접치료시 재현성 평가)

  • Kim Jong-Hwa;Son Jung-Hae;Jung Chil;Kim Mi-Hwa
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.15 no.1
    • /
    • pp.29-33
    • /
    • 2003
  • I. Purpose Brachytherapy is the main component in treatment of patients with uterine cervical cancer. The reproducibility of applicator position in the same patient at repeated treatments was very important for accurate dose delivery. It was aimed to evaluate the change of applicator location between each high dose rate(HDR) brachytherapy insertion in the patients with uterine cervical cancer. II. Materials and Methods From January 1999 to October 2001, total 52 patients were treated with external beam radiotherapy and HDR brachytherapy (Microselectron, Nucletron). During six to seven times of brachytherapy, all patients had three treatment plans. From the orthogonal radiographs, we measured the following variables; height from upper border of pubic bone to os (HPO), distance from sacral promontory to tip of tandem (DST), distance from coccyx to os (DCO), distance from tip of right ovoid to os (DRO), distance from tip of left ovoid to os (DLO), and distance from center of the first tandem source to ovoid (DTO). To evaluate the reproducibility of applicator position, it was calculated the standard deviation of differences between three insertions for the 7 parameters in each patient. III. Results The ranges of standard deviations of interfractional differences for the variables were as follows. 1)HPO : $0{\sim}0.79cm$ 2)DST : $0{\sim}0.9cm$ 3)DCO : $0.06{\sim}0.76cm$ 4)DRO : $0{\sim}0.53cm$ 5)DLO : $0{\sim}0.45cm$ 6) DTO $0{\sim}0.36cm$ IV. Conclusions There was some change in applicator position on repeated implants in our study. But variation of the interfractional differences was minimal; in all parameters, there were less than 1 cm. We are continued to try for reducing the geometric variation between each procedure.

  • PDF

A Study on the Standardization of QSCCII (Questionnaire for the Sasang Constitution Classification II) (사상체질분류검사지(四象體質分類檢査紙)(QSCC)II의 표준화(標準化) 연구(硏究) -각(各) 체질집단(體質集團)의 군집별(群集別) Profile 분석(分析)을 중심(中心)으로-)

  • Kim, Sun Ho;Go, Byeong-Hui;Song, Il-Byeong
    • Journal of Sasang Constitutional Medicine
    • /
    • v.8 no.1
    • /
    • pp.187-246
    • /
    • 1996
  • The purpose of this study is to evaluate and standardize the four scales of Questionnaire for the Sasang Constitution ClassificationII (QSCCII). QSCCII is newly prepared by statistical item analysis and is designed to examine its diagnostic discriminability. QSCCII is administered to 1366 random informants. From the survey, we could get the data for the standardization. The criteria of standardization are based on the data from 265 informants who are examined by professionals. Collected data are analyzed by internal consistency, variation analysis(ANOVA), Duncan test and discrimination analysis of SPSS PC+ V4.0 program. The results are as follows 1) The reliability of four scales for QSCCII is relatively valid. The internal consistency of Tae-yang(太陽) scale is Cronbach's ${\alpha}=0.5708$. That of So-yang(少陽) scale is ${\alpha}=0.5708$. That of Tae-eum(太陰) scale is ${\alpha}=0.5922$. That of So-eum(少陰) scale is ${\alpha}=0.6319$. 2) There is a significant difference between each group through variation analysis of four scales. 3) The process of standardization is based on the average value and standard deviation with respect to age and sex difference of each criteria. 4) This study suggests a source of standardization of Sasang Constitution Classification by providing norms in which the differences of age, sex, and number of items are taken into deep consideration. QSCCII, therefore, can be applied to every age(the 10's to the 60's) and sex groups. 5) The recalculation of the raw-score to standard value (T-score) shows that the diagnostic discriminability (Hit-ratio : 70.08%) of QSCCII brings about 37% improvement than proportional chance criteria(33.33%). Especially, Hit-ratios of Tae-eum In(74.5%) and So-eum In(70.8%) are higher than that of So-yang In(60.0%). 6) QSCC has discriminability only to male informants. Compared with QSCC, however, QSCCII has relatively efficient discriminability both to male and female informants. 7) These results would be a demonstration of the fact that the QSCCII could be used as a tool for sasang constitution classification.

  • PDF

Radioimmunoassay for Determination of Serum Macrophage Migration Inhibitory Factor (혈중 대식세포 유주 저지 인자 측정을 위한 방사면역측정법)

  • Lee, Tae-Sup;Shin, Seok-Hwan;Song, Jee-In;Woo, Kwang-Sun;Chung, Wee-Sup;Choi, Chang-Woon;Lim, Sang-Moo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.6
    • /
    • pp.532-539
    • /
    • 2004
  • Purpose: There has been a renewal of interest in Macrophage migration inhibitory factor (MIF), especially correlation in pathogenesis of sepsis by many infectious diseases and in regulation of host inflammatory and immune response. We developed immunoradiometric assay (IRMA) to determine serum human MIF concentration. Materials and Methods: The IRMA system utilizes solid phase bound monoclonal anti-recombinant human MIF (rhMIF) antibody as a capture antibody, biotinylated polyclonal anti-rhMIF antibody as a detector antibody. We applied with rhMIF that concentration of standard solutions increased from 0 ng/ml to 100 ng/ml. We used $^{125}I$-streptavidin (SA) as radiotracer to determination of rhMIF concentration. Streptavidin was labeled with $^{125}I$ by Chloramine-T method and $^{125}I$-SA was purified by ultracentrifugation. $^{125}I$-SA stability was evaluated by ITLC analysis at $4^{\circ}C$ and room temperatures until 60days. To validate IRMA system for MIF, we experimented intra-assay and inter-assay coefficients of variation, recovery test and dilution test. Results: Radiolabeling yield of $^{125}I$-SA was 87% and purified $^{125}I$-SA retained above 99% radiochemical purity. $^{125}I$-SA showed above 93% stability in $4^{\circ}C$ until 60days that it is good for immunoradiometric assay as radiotracer. Plotted standard dose response curve showed that increased concentration of rhMIF linearly correlated (R2=0.99) with bound radioactivity of $^{125}I$-SA. The highest intra- and inter-assay coefficients of variation were 5.5% and 7.6%, respectively. The average of recovery of MIF in samples was 102%. In dilution test, linear response curves were obtained (R2=0.97). Conclusion: Radioimmunoassay using $^{125}I$-SA as radiotracer thought to be useful for the determination of serum MIF concentration, and further, its data will be used to evaluate the correlation between clinical significance and serum MIF concentration in patients with various inflammatory diseases.

Analysis of Commercial Organic Compost Manufactured with Livestock Manure (국내 유통중인 가축분퇴비의 품질 특성)

  • Kim, Myung-Sook;Kim, Seok-Cheol;Park, Seong-Jin;Lee, Chang-Hoon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.26 no.4
    • /
    • pp.21-29
    • /
    • 2018
  • The contents of total nitrogen(T-N), phosphate($T-P_2O_5$), and potash($T-K_2O$) are important factors to determine the application rate of the livestock compost to prevent nutrients accumulation and maintain their appropriate levels in arable lands. The concentrations of nutrient, organic matter, salt, water content, heavy metal in livestock compost in circulation were investigated with 659 samples from 2016 to 2017. In order to investigate the fluctuation nutrient contents of livestock composts with the same product name, 19 samples were collected and analyzed T-N, and $T-P_2O_5$, and $T-K_2O$ concentration during two years. The mean levels of T-N, $T-P_2O_5$, and $T-K_2O$ in livestock composts of from 2016 to 2017 were 1.73%, 1.88%, and 1.66%, respectively. The average contents of organic matter, water, and salt were 38.9%, 40.9%, and 1.2%, respectively. There were found that the maximum concentrations of Cr, Ni, Cu, and Zn in some livestock composts were exceeded the criteria of the official standard of commercial fertilizer. The maximum variation coefficient of T-N, $T-P_2O_5$ and $T-K_2O$ content of livestock composts was found to be 24%, 27%, and 50% on average, respectively. In order to manage the nutrients in agricultural soils, it will be reasonable that the error range of T-N and $T-P_2O_5$ content in livestock composts should be recommended to be 27% in mean as variation coefficient in case of displaying the nutrient element in liverstock compost.

Variation on Estimated Values of Radioactivity Concentration According to the Change of the Acquisition Time of SPECT/CT (SPECT/CT의 획득시간 증감에 따른 방사능농도 추정치의 변화)

  • Kim, Ji-Hyeon;Lee, Jooyoung;Son, Hyeon-Soo;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.15-24
    • /
    • 2021
  • Purpose SPECT/CT was noted for its excellent correction method and qualitative functions based on fusion images in the early stages of dissemination, and interest in and utilization of quantitative functions has been increasing with the recent introduction of companion diagnostic therapy(Theranostics). Unlike PET/CT, various conditions like the type of collimator and detector rotation are a challenging factor for image acquisition and reconstruction methods at absolute quantification of SPECT/CT. Therefore, in this study, We want to find out the effect on the radioactivity concentration estimate by the increase or decrease of the total acquisition time according to the number of projections and the acquisition time per projection among SPECT/CT imaging conditions. Materials and Methods After filling the 9,293 ml cylindrical phantom with sterile water and diluting 99mTc 91.76 MBq, the standard image was taken with a total acquisition time of 600 sec (10 sec/frame × 120 frames, matrix size 128 × 128) and also volume sensitivity and the calibration factor was verified. Based on the standard image, the comparative images were obtained by increasing or decreasing the total acquisition time. namely 60 (-90%), 150 (-75%), 300 (-50%), 450 (-25%), 900 (+50%), and 1200 (+100%) sec. For each image detail, the acquisition time(sec/frame) per projection was set to 1.0, 2.5, 5.0, 7.5, 15.0 and 20.0 sec (fixed number of projections: 120 frame) and the number of projection images was set to 12, 30, 60, 90, 180 and 240 frames(fixed time per projection:10 sec). Based on the coefficients measured through the volume of interest in each acquired image, the percentage of variation about the contrast to noise ratio (CNR) was determined as a qualitative assessment, and the quantitative assessment was conducted through the percentage of variation of the radioactivity concentration estimate. At this time, the relationship between the radioactivity concentration estimate (cps/ml) and the actual radioactivity concentration (Bq/ml) was compared and analyzed using the recovery coefficient (RC_Recovery Coefficients) as an indicator. Results The results [CNR, radioactivity Concentration, RC] by the change in the number of projections for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.5%, +3.90%, 1.04] at -90%, [-77.9%, +2.71%, 1.03] at -75%, [-55.6%, +1.85%, 1.02] at -50%, [-33.6%, +1.37%, 1.01] at -25%, [-33.7%, +0.71%, 1.01] at +50%, [+93.2%, +0.32%, 1.00] at +100%. and also The results [CNR, radioactivity Concentration, RC] by the acquisition time change for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.3%, -3.55%, 0.96] at - 90%, [-73.4%, -0.17%, 1.00] at -75%, [-49.6%, -0.34%, 1.00] at -50%, [-24.9%, 0.03%, 1.00] at -25%, [+49.3%, -0.04%, 1.00] at +50%, [+99.0%, +0.11%, 1.00] at +100%. Conclusion In SPECT/CT, the total coefficient obtained according to the increase or decrease of the total acquisition time and the resulting image quality (CNR) showed a pattern that changed proportionally. On the other hand, quantitative evaluations through absolute quantification showed a change of less than 5% (-3.55 to +3.90%) under all experimental conditions, maintaining quantitative accuracy (RC 0.96 to 1.04). Considering the reduction of the total acquisition time rather than the increasing of the image acquiring time, The reduction in total acquisition time is applicable to quantitative analysis without significant loss and is judged to be clinically effective. This study shows that when increasing or decreasing of total acquisition time, changes in acquisition time per projection have fewer fluctuations that occur in qualitative and quantitative condition changes than the change in the number of projections under the same scanning time conditions.

Comparison of Batch Assay and Random Assay Using Automatic Dispenser in Radioimmunoassay (핵의학 체외 검사에서 자동분주기를 이용한 Random Assay 가능성평가)

  • Moon, Seung-Hwan;Lee, Ho-Young;Shin, Sun-Young;Min, Gyeong-Sun;Lee, Hyun-Joo;Jang, Su-Jin;Kang, Ji-Yeon;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.4
    • /
    • pp.323-329
    • /
    • 2009
  • Purpose: Radioimmunoassay (RIA) was usually performed by the batch assay. To improve the efficiency of RIA without increase of the cost and time, random assay could be a choice. We investigated the possibility of the random assay using automatic dispenser by assessing the agreement between batch assay and random assay. Materials and Methods: The experiments were performed with four items; Triiodothyronine (T3), free thyroxine (fT4), Prostate specific antigen (PSA), Carcinoembryonic antigen (CEA). In each item, the sera of twenty patients, the standard, and the control samples were used. The measurements were done 4 times with 3 hour time intervals by random assay and batch assay. The coefficient of variation (CV) of the standard samples and patients' data in T3, fT4, PSA, and CEA were assessed. ICC (Intraclass correlation coefficient) and coefficient of correlation were measured to assessing the agreement between two methods. Results: The CVs (%) of T3, fT4, PSA, and CEA measured by batch assay were 3.2$\pm$1.7%, 3.9$\pm$2.1%, 7.1$\pm$6.2%, 11.2$\pm$7.2%. The CVs by random assay were 2.1$\pm$1.7%, 4.8$\pm$3.1%, 3.6$\pm$4.8%, and 7.4$\pm$6.2%. The ICC between the batch assay and random assay were 0.9968 (T3), 0.9973 (fT4), 0.9996 (PSA), and 0.9901 (CEA). The coefficient of correlation between the batch assay and random assay were 0.9924(T3), 0.9974 (fT4), 0.9994 (PSA), and 0.9989 (CEA) (p<0.05). Conclusion: The results of random assay showed strong agreement with the batch assay in a day. These results suggest that random assay using automatic dispenser could be used in radioimmunoassay.

Detection of Copy Number Variation of the KIT Gene in the Landrace Breed using an Quantitative Oligonucleotide Ligation Assay(qOLA) (Quantitative Oligonucleotide Ligation Assay(qOLA)를 이용한 Landrace 품종의 KIT 유전자 반복수 변이 탐지)

  • Seo, B.Y.;Kim, J.H.;Nahm, D.W.;Yoo, C.K.;Lee, S.H.;Lee, J.B.;Lim, H.T.;Jung, E.J.;Cho, I.C.;Heo, K.N.;Jeon, J.T.
    • Journal of Animal Science and Technology
    • /
    • v.49 no.5
    • /
    • pp.559-568
    • /
    • 2007
  • Recently, copy number variations (CNV) of genes or genomic segments have been intensively studied and various analysis methods have been developed. In this study, quantitative oligonucleotide ligation assay (qOLA) was applied to investigate CNV of KIT gene in the Landrace breed. A combined assay using qOLA and pyrosequencing, 6 genotype classes, I1/I1 or I3/i (IBe), I1/I2 or I3/IP, I1/I3, I1/IP or I2/i (IBe), I2/I2and I2/IP, were identified from 44 Landrace pigs. Genotype assignment using grouping features of measurements on a scatter plot showed 100% agreement with those using a statistical assignment by PROC FASTCLUS procedure implemented in the SAS package. Two versions (3100 and 3130) of ABI sequencers gave the same genotyping results, indicating there was no influence on qOLA by different versions of instrument, however, the means of standard deviation and coefficient of variation from the qOLA on a ABI 3130 (2.33 and 4.10) was lower than those from the qOLA on a ABI 3100 (2.67 and 4.81). Effect of proteinase K treatment on the PCR product followed by qOLA was very clear because noise peaks were disappeared and the observed ration fit better to the reference ratio corresponding to each genotype.

Establishment and Application of Landscape Control Point Selection Method for Landscape Assessment of Urban Development Projects (도시개발사업의 경관평가를 위한 조망점 선정체계 구축 및 적용)

  • Jang, Cheol-Kyu;Jung, Sung-Gwan;Kim, Kyung-Tae
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.39 no.3
    • /
    • pp.39-50
    • /
    • 2011
  • This study furnishes basis data for plan foundation and proper valuation of view by presenting objective and concrete selection standards and ways of Landscape Control Point(LCP) on valuation of development projects. To sum up the results of study, it establishes the prospect, publicity and direction of view as a selection standard LCP on precedent studies. The prospect, which includes visual range, direction of view, geographical features, and visibility, sets up as a valuation basis picking out the available places which have alterations according to direction and distance in practice. In the case of publicity, to select the place as there presentative area where public activities often happen than others, thirteen evaluation indexes including administration facilities, educational facilities, commercial facilities and so on. And variation of landscape is set up as an assessment index to know how much the land has changed from the beginning to the end of development. To apply the selection standards to sample places, the preliminary LCP is founded by analyzing both the prospect and published; a series of courses for selecting the final LCP is founded by analyzing the preliminary LCP and variableness of landscape on a basic of placed which have many alterations of view. At last, in the case of a selection system for LCP, the preliminary LCP is founded by analyzing both the prospect and publicity; a series of courses for selecting the final LCP is found by analyzing the preliminary LCP and variableness of landscape. Applying selection standards and the assessment index to the Sam-deok 3 residence improvement area, in the case of prospect, the southern distant view area has the largest extent. Next, the results of the assessment using the system of publicity show that a five-lane road is taking up the largest area. Hence, a total of 48 preliminary LCPs are set up by analyzing both the prospect and publicity. The results of analyzing landscape variation, one of the valuation indexes, show that Sam-deok dong around the post office has the highest rate of variation at 28.07%. Finally, three LCPs in each part, which are close range, middle range and distance view, are selected; thus, a total of nine LCPs are selected. The selected LCPs that go through a series of practical courses like a GIS program have a lot of professional opinions and are expected to secure objectivity of landscape assessment.

ROC Analysis of Visual Assessments Made in Gated Blood Pool Scans of Patients with Coronary Artery Disease (관상동맥질환에서 심장풀 스캔의 육안적 평가에 대한 ROC 분석)

  • Lee, Kyun-Han;Choi, Yoon-Ho;Lee, Bum-Woo;Moon, Dae-Hyuk;Koong, Sung-Soo;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.23 no.2
    • /
    • pp.175-181
    • /
    • 1989
  • Visual assessment of regional wall motion abnormality (RWMA) by gated blood pol scan (GBPS) serves as an useful parameter in the diagnosis, functional evaluation, and follow up in various clinical settings, but are still subject to some inherent limitations. On important problem may be the interobserver as well as intraobsever variation that may well be present due to the subjective nature of the interpretations. This study was carried out to determine the reliability and reproducibility of visual assessments made in GBPSs, and to observe the degree to which the results would be influenced by observer variation. Fifty two patients with coronary heart disease had resting GBPS and contrast ventriculography within 4 days appall. Contrast ventriculography-showed normal wall motion in 6 patients and the remaining 46 had RWMA in one or more segments. The anterior and left anterolateral views of all 52 GBPSs were analyzed by three independent observers, who selected from 5 scales, their level of confidence that there was RWMA in that segment. Reciever operating characteristic (ROC) curves for each analysis was plotted and the area under the curve $(\theta)$ was used as a parameter representing each observer's performance in his interpretations. The findings of contrast ventriculographies were used as the standard for RWMA. The apical and inferoapical segments showed the best correlation with contrast ventriculography ($\theta=0.90-0.94$, 0.81-0.94, respectively), and the inferior wall showed the poorest correlation $(\theta=0.70-0.74)$. The interpretations of the inferior, septal, apical, and posteroinferior, segments showed no difference between the observers, but there was significantly better performance in assessment by observer A compared to that by B or C for the anterolateral segments ($\theta=0.87$, 0.78, 0.76, respectively. p<0.01 for A vs B, p<0.05 for A vs C), as well as when all segments were considered altogether ($\theta=0.88$, 0.83, 0.82, respectively. both p<0.05). This was also true for the infero-apical segment between A and C ($\theta=0.09$, 0.81, p<0.05). The intraobserver variation, however, did not appear significant, with only the inferior segment for observer B showing any significant difference when observer A and B repeated the analysis 10 days latter. There was no difference in assessing dyskinesia, with all observers showing a high performance ($\theta=0.98$, 0.87, 0.97, respectively). The visual assessment of left ventricular ejection fraction by all three observers correlated well with the calculated value from a semiautomated method (Spearman's r = 0.91, 0.83, 0.83. p<0.01, p<0.05, p < 0.05). The assessment of LV and RV size also correlated well between the three observers (Kendall's w = 0.80, 0.51, p<0.01 for both left and right ventricles). The above findings suggest that RWMA visually assessed by GBPS correlates well with that done by contrast ventriculography. And although the observer's experience or skill may influence the results in certain segments, visual analysis of GBPS may serve as a reliable and reproducible means for evaluating ventricular function.

  • PDF