• Title/Summary/Keyword: Standard time

Search Result 8,333, Processing Time 0.055 seconds

On the present bamboo groves of Cholla-nam-do and their proper treatment -No. 1. On the growing stock of reprsentative phyllostachys reticulata grove by county (전라남도(全羅南道)의 죽림현황(竹林現況)과 그 개선대책(改善對策) -제일(第一), 각군별대표고죽림(各郡別代表苦竹林)의 몇가지 죽간형질(竹桿形質)과 축적(蓄積)에 대하여)

  • Chung, Dong Oh
    • Journal of Korean Society of Forest Science
    • /
    • v.2 no.1
    • /
    • pp.19-28
    • /
    • 1962
  • Total area of bamboo groves in Korea which is limited to $37^{\circ}$ north latitude, i.e., to southern part of Chungchung-nam-do Province and Kangwon-do Province, is 3,235ha., but this country must import about 3,000 metric ton's bamboo culms from Japan every year. It may be true that the country is not so fit for economical cultivation of bamboo groves from the view point of climatic condition, but the author believes that self-sufficiency in bamboo is not impossible if some scientific method for improving bamboo groves is introduced to our primitive groves. Keeping this point in his mind the auther tried to study on the bamboo groves in the country, and as the first step set about to investigate the actual state of twenty good bamboo groves located in Cholla-nam-do Province from March, 1961 to January, 1962. This is a report on some characters of bamboo culms and growing stock with samples collected in the present investigation. 1) Numbers of bamboo culm per 0.1ha. are 1,183 in average, 1,840 in maximum and 87.5 in minimum before harvesting. 2) According to owners' saying, 1960 was such an off-year that they could hardly see any yearling bamboos in groves, but in 1961 very many new bamboos are produced as follows: the proportion of the number of yearling bamboos produced this year to that of mature bamboos (over 2 years old) is 58.7% in average; the highest 110.5% and the lowest 16.8%. 3) the average diameter of culms at eye height is 6.5cm, but the biggest diameter comes to 11.2 cm, and the average diameters of yearling and mature bamboos are 6.5cm and 6.6cm respectively. 4) Internode length records 29.4 cm in average, the shortest 21.3 cm and the longest 38.4 cm. Average internode lengths of new culms and mature culms are 27.6 cm and 29.4 cm respectively. This shows that the internode length of new culms is in the decrease to that of maturer's. 5) Through this investigation, it was found that internode length is in the influence of the exposure and density of bamboo groves, i. e., the more the dencity of bamboo groves is and the more the exposure nears the north-east, the longer the internode length becomes (see Table 7 and 8). 6) In the growing stock of bamboo groves, bundles per 0.1ha. amount to 271 sok (unit of bundle) in total average, 445 sok in maximum and 126 sok in minimum. 7) Among twenty typical bamboo groves, chosen in each County in Cholla-nam-do Province, only one passes perfectly by Veda's standard rule* prescribing the good bamboo grove, but the eight groves shown in Table 9 could be recommended as good ones in Cholla-nam-do Province, because the auther believes that those groves may be improved better, if we pay more attention to the management of them. 8) Considering that they have managed their groves carelessly and primitively, and that unfortunately their groves must have faced almost on clear felling over the entire area at the time of the Korean War, we can surely expect much more increments in bamboo groves, if we introduce some scientific methods in managing their groves.

  • PDF

Establishment of Analytical Method for Dichlorprop Residues, a Plant Growth Regulator in Agricultural Commodities Using GC/ECD (GC/ECD를 이용한 농산물 중 생장조정제 dichlorprop 잔류 분석법 확립)

  • Lee, Sang-Mok;Kim, Jae-Young;Kim, Tae-Hoon;Lee, Han-Jin;Chang, Moon-Ik;Kim, Hee-Jeong;Cho, Yoon-Jae;Choi, Si-Won;Kim, Myung-Ae;Kim, MeeKyung;Rhee, Gyu-Seek;Lee, Sang-Jae
    • Korean Journal of Environmental Agriculture
    • /
    • v.32 no.3
    • /
    • pp.214-223
    • /
    • 2013
  • BACKGROUND: This study focused on the development of an analytical method about dichlorprop (DCPP; 2-(2,4-dichlorophenoxy)propionic acid) which is a plant growth regulator, a synthetic auxin for agricultural commodities. DCPP prevents falling of fruits during their growth periods. However, the overdose of DCPP caused the unwanted maturing time and reduce the safe storage period. If we take fruits with exceeding maximum residue limits, it could be harmful. Therefore, this study presented the analytical method of DCPP in agricultural commodities for the nation-wide pesticide residues monitoring program of the Ministry of Food and Drug Safety. METHODS AND RESULTS: We adopted the analytical method for DCPP in agricultural commodities by gas chromatograph in cooperated with Electron Capture Detector(ECD). Sample extraction and purification by ion-associated partition method were applied, then quantitation was done by GC/ECD with DB-17, a moderate polarity column under the temperature-rising condition with nitrogen as a carrier gas and split-less mode. Standard calibration curve presented linearity with the correlation coefficient ($r^2$) > 0.9998, analysed from 0.1 to 2.0 mg/L concentration. Limit of quantitation in agricultural commodities represents 0.05 mg/kg, and average recoveries ranged from 78.8 to 102.2%. The repeatability of measurements expressed as coefficient of variation (CV %) was less than 9.5% in 0.05, 0.10, and 0.50 mg/kg. CONCLUSION(S): Our newly improved analytical method for DCPP residues in agricultural commodities was applicable to the nation-wide pesticide residues monitoring program with the acceptable level of sensitivity, repeatability and reproducibility.

The Evaluation of Attenuation Difference and SUV According to Arm Position in Whole Body PET/CT (전신 PET/CT 검사에서 팔의 위치에 따른 감약 정도와 SUV 변화 평가)

  • Kwak, In-Suk;Lee, Hyuk;Choi, Sung-Wook;Suk, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.21-25
    • /
    • 2010
  • Purpose: For better PET imaging with accuracy the transmission scanning is inevitably required for attenuation correction. The attenuation is affected by condition of acquisition and patient position, consequently quantitative accuracy may be decreased in emission scan imaging. In this paper, the present study aims at providing the measurement for attenuation varying with the positions of the patient's arm in whole body PET/CT, further performing the comparative analysis over its SUV changes. Materials and Methods: NEMA 1994 PET phantom was filled with $^{18}F$-FDG and the concentration ratio of insert cylinder and background water fit to 4:1. Phantom images were acquired through emission scanning for 4min after conducting transmission scanning by using CT. In an attempt to acquire image at the state that the arm of the patient was positioned at the lower of ahead, image was acquired in away that two pieces of Teflon inserts were used additionally by fixing phantoms at both sides of phantom. The acquired imaged at a were reconstructed by applying the iterative reconstruction method (iteration: 2, subset: 28) as well as attenuation correction using the CT, and then VOI was drawn on each image plane so as to measure CT number and SUV and comparatively analyze axial uniformity (A.U=Standard deviation/Average SUV) of PET images. Results: It was found from the above phantom test that, when comparing two cases of whether Teflon insert was fixed or removed, the CT number of cylinder increased from -5.76 HU to 0 HU, while SUV decreased from 24.64 to 24.29 and A.U from 0.064 to 0.052. And the CT number of background water was identified to increase from -6.14 HU to -0.43 HU, whereas SUV decreased from 6.3 to 5.6 and A.U also decreased from 0.12 to 0.10. In addition, as for the patient image, CT number was verified to increase from 53.09 HU to 58.31 HU and SUV decreased from 24.96 to 21.81 when the patient's arm was positioned over the head rather than when it was lowered. Conclusion: When arms up protocol was applied, the SUV of phantom and patient image was decreased by 1.4% and 9.2% respectively. With the present study it was concluded that in case of PET/CT scanning against the whole body of a patient the position of patient's arm was not so much significant. Especially, the scanning under the condition that the arm is raised over to the head gives rise to more probability that the patient is likely to move due to long scanning time that causes the increase of uptake of $^{18}F$-FDG of brown fat at the shoulder part together with increased pain imposing to the shoulder and discomfort to a patient. As regarding consideration all of such factors, it could be rationally drawn that PET/CT scanning could be made with the arm of the subject lowered.

  • PDF

Study on PM10, PM2.5 Reduction Effects and Measurement Method of Vegetation Bio-Filters System in Multi-Use Facility (다중이용시설 내 식생바이오필터 시스템의 PM10, PM2.5 저감효과 및 측정방법에 대한 연구)

  • Kim, Tae-Han;Choi, Boo-Hun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.48 no.5
    • /
    • pp.80-88
    • /
    • 2020
  • With the issuance of one-week fine dust emergency reduction measures in March 2019, the public's anxiety about fine dust is increasingly growing. In order to assess the application of air purifying plant-based bio-filters to public facilities, this study presented a method for measuring pollutant reduction effects by creating an indoor environment for continuous discharge of particle pollutants and conducted basic studies to verify whether indoor air quality has improved through the system. In this study conducted in a lecture room in spring, the background concentration was created by using mosquito repellent incense as a pollutant one hour before monitoring. Then, according to the schedule, the fine dust reduction capacity was monitored by irrigating for two hours and venting air for one hour. PM10, PM2.5, and temperature & humidity sensors were installed two meters front of the bio-filters, and velocity probes were installed at the center of the three air vents to conduct time-series monitoring. The average face velocity of three air vents set up in the bio-filter was 0.38±0.16 m/s. Total air-conditioning air volume was calculated at 776.89±320.16㎥/h by applying an air vent area of 0.29m×0.65m after deducing damper area. With the system in operation, average temperature and average relative humidity were maintained at 21.5-22.3℃, and 63.79-73.6%, respectively, which indicates that it satisfies temperature and humidity range of various conditions of preceding studies. When the effects of raising relatively humidity rapidly by operating system's air-conditioning function are used efficiently, it would be possible to reduce indoor fine dust and maintain appropriate relative humidity seasonally. Concentration of fine dust increased the same in all cycles before operating the bio-filter system. After operating the system, in cycle 1 blast section (C-1, β=-3.83, β=-2.45), particulate matters (PM10) were lowered by up to 28.8% or 560.3㎍/㎥ and fine particulate matters (PM2.5) were reduced by up to 28.0% or 350.0㎍/㎥. Then, the concentration of find dust (PM10, PM2.5) was reduced by up to 32.6% or 647.0㎍/㎥ and 32.4% or 401.3㎍/㎥ respectively through reduction in cycle 2 blast section (C-2, β=-5.50, β=-3.30) and up to 30.8% or 732.7㎍/㎥ and 31.0% or 459.3㎍/㎥ respectively through reduction in cycle 3 blast section (C-3, β=5.48, β=-3.51). By referring to standards and regulations related to the installation of vegetation bio-filters in public facilities, this study provided plans on how to set up objective performance evaluation environment. By doing so, it was possible to create monitoring infrastructure more objective than a regular lecture room environment and secure relatively reliable data.

A Study on Market Size Estimation Method by Product Group Using Word2Vec Algorithm (Word2Vec을 활용한 제품군별 시장규모 추정 방법에 관한 연구)

  • Jung, Ye Lim;Kim, Ji Hui;Yoo, Hyoung Sun
    • Journal of Intelligence and Information Systems
    • /
    • v.26 no.1
    • /
    • pp.1-21
    • /
    • 2020
  • With the rapid development of artificial intelligence technology, various techniques have been developed to extract meaningful information from unstructured text data which constitutes a large portion of big data. Over the past decades, text mining technologies have been utilized in various industries for practical applications. In the field of business intelligence, it has been employed to discover new market and/or technology opportunities and support rational decision making of business participants. The market information such as market size, market growth rate, and market share is essential for setting companies' business strategies. There has been a continuous demand in various fields for specific product level-market information. However, the information has been generally provided at industry level or broad categories based on classification standards, making it difficult to obtain specific and proper information. In this regard, we propose a new methodology that can estimate the market sizes of product groups at more detailed levels than that of previously offered. We applied Word2Vec algorithm, a neural network based semantic word embedding model, to enable automatic market size estimation from individual companies' product information in a bottom-up manner. The overall process is as follows: First, the data related to product information is collected, refined, and restructured into suitable form for applying Word2Vec model. Next, the preprocessed data is embedded into vector space by Word2Vec and then the product groups are derived by extracting similar products names based on cosine similarity calculation. Finally, the sales data on the extracted products is summated to estimate the market size of the product groups. As an experimental data, text data of product names from Statistics Korea's microdata (345,103 cases) were mapped in multidimensional vector space by Word2Vec training. We performed parameters optimization for training and then applied vector dimension of 300 and window size of 15 as optimized parameters for further experiments. We employed index words of Korean Standard Industry Classification (KSIC) as a product name dataset to more efficiently cluster product groups. The product names which are similar to KSIC indexes were extracted based on cosine similarity. The market size of extracted products as one product category was calculated from individual companies' sales data. The market sizes of 11,654 specific product lines were automatically estimated by the proposed model. For the performance verification, the results were compared with actual market size of some items. The Pearson's correlation coefficient was 0.513. Our approach has several advantages differing from the previous studies. First, text mining and machine learning techniques were applied for the first time on market size estimation, overcoming the limitations of traditional sampling based- or multiple assumption required-methods. In addition, the level of market category can be easily and efficiently adjusted according to the purpose of information use by changing cosine similarity threshold. Furthermore, it has a high potential of practical applications since it can resolve unmet needs for detailed market size information in public and private sectors. Specifically, it can be utilized in technology evaluation and technology commercialization support program conducted by governmental institutions, as well as business strategies consulting and market analysis report publishing by private firms. The limitation of our study is that the presented model needs to be improved in terms of accuracy and reliability. The semantic-based word embedding module can be advanced by giving a proper order in the preprocessed dataset or by combining another algorithm such as Jaccard similarity with Word2Vec. Also, the methods of product group clustering can be changed to other types of unsupervised machine learning algorithm. Our group is currently working on subsequent studies and we expect that it can further improve the performance of the conceptually proposed basic model in this study.

The Influence of Ventilation and Shade on the Mean Radiant Temperature of Summer Outdoor (통풍과 차양이 하절기 옥외공간의 평균복사온도에 미치는 영향)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.5
    • /
    • pp.100-108
    • /
    • 2012
  • The purpose of the study was to evaluate the influence of shading and ventilation on Mean Radiant Temperature(MRT) of the outdoor space at a summer outdoor. The Wind Speed(WS), Air Temperature(AT) and Globe Temperature(GT) were recorded every minute from $1^{st}$ of May to the $30^{th}$ of September 2011 at a height of 1.2m above in four experimental plots with different shading and ventilating conditions, with a measuring system consisting of a vane type anemometer(Barini Design's BDTH), Resistance Temperature Detector(RTD, Pt-100), standard black globe(${\O}$ 150mm) and data acquisition systems(National Instrument's Labview and Compfile Techs' Moacon). To implement four different ventilating and shading conditions, three hexahedral steel frames, and one natural plot were established in the open grass field. Two of the steel frames had a dimension of $3m(W){\times}3m(L){\times}1.5m(H)$ and every vertical side covered with transparent polyethylene film to prevent lateral ventilation(Ventilation Blocking Plot: VP), and an additional shading curtain was applied on the top side of a frame(Shading and Ventilation Blocking Plot: SVP). The third was $1.5m(W){\times}1.5m(L){\times}1.5m(H)$, only the top side of which was covered by the shading curtain without the lateral film(Shading Plot: SP). The last plot was natural condition without any kind of shading and wind blocking material(Natural Open Plot: NP). Based on the 13,262 records of 44 sunny days, the time serial difference of AT and GT for 24 hour were analyzed and compared, and statistical analysis was done based on the 7,172 records of daytime period from 7 A.M. to 8 P.M., while the relation between the MRT and solar radiation and wind speed was analyzed based on the records of the hottest period from 11 A.M. to 4 P.M.. The major findings were as follows: 1. The peak AT was $40.8^{\circ}C$ at VP and $35.6^{\circ}C$ at SP showing the difference about $5^{\circ}C$, but the difference of average AT was very small within${\pm}1^{\circ}C$. 2. The difference of the peak GT was $12^{\circ}C$ showing $52.5^{\circ}C$ at VP and $40.6^{\circ}C$ at SP, while the gap of average GT between the two plots was $6^{\circ}C$. Comparing all four plots including NP and SVP, it can be said that the shading decrease $6^{\circ}C$ GT while the wind blocking increase $3^{\circ}C$ GT. 3. According to the calculated MRT, the shading has a cooling effect in reducing a maximum of $13^{\circ}C$ and average $9^{\circ}C$ MRT, while the wind blocking has heating effect of increasing average $3^{\circ}C$ MRT. In other words, the MRT of the shaded area with natural ventilation could be cooler than the wind blocking the sunny site to about $16^{\circ}C$ MRT maximum. 4. The regression and correlation tests showed that the shading is more important than the ventilation in reducing the MRT, while both of them do an important role in improving the outdoor thermal comfort. In summary, the results of this study showed that the shade is the first and the ventilation is the second important factor in terms of improving outdoor thermal comfort in summer daylight hours. Therefore, it can be apparently said that the more shade by the forest, shading trees etc., the more effective in conditioning the microclimate of an outdoor space reducing the useless or even harmful heat energy for human activities. Furthermore, the delicately designed wind corridor or outdoor ventilation system can improve even the thermal environment of urban area.

Dosimetric Evaluation of a Small Intraoral X-ray Tube for Dental Imaging (치과용 초소형 X-선 튜브의 선량평가)

  • Ji, Yunseo;Kim, YeonWoo;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.160-167
    • /
    • 2015
  • Radiation exposure from medical diagnostic imaging procedures to patients is one of the most significant interests in diagnostic x-ray system. A miniature x-ray intraoral tube was developed for the first time in the world which can be inserted into the mouth for imaging. Dose evaluation should be carried out in order to utilize such an imaging device for clinical use. In this study, dose evaluation of the new x-ray unit was performed by 1) using a custom made in vivo Pig phantom, 2) determining exposure condition for the clinical use, and 3) measuring patient dose of the new system. On the basis of DRLs (Diagnostic Reference Level) recommended by KDFA (Korea Food & Drug Administration), the ESD (Entrance Skin Dose) and DAP (Dose Area Product) measurements for the new x-ray imaging device were designed and measured. The maximum voltage and current of the x-ray tubes used in this study were 55 kVp, and 300 mA. The active area of the detector was $72{\times}72mm$ with pixel size of $48{\mu}m$. To obtain the operating condition of the new system, pig jaw phantom images showing major tooth-associated tissues, such as clown, pulp cavity were acquired at 1 frame/sec. Changing the beam currents 20 to $80{\mu}A$, x-ray images of 50 frames were obtained for one beam current with optimum x-ray exposure setting. Pig jaw phantom images were acquired from two commercial x-ray imaging units and compared to the new x-ray device: CS 2100, Carestream Dental LLC and EXARO, HIOSSEN, Inc. Their exposure conditions were 60 kV, 7 mA, and 60 kV, 2 mA, respectively. Comparing the new x-ray device and conventional x-ray imaging units, images of the new x-ray device around teeth and their neighboring tissues turn out to be better in spite of its small x-ray field size. ESD of the new x-ray device was measured 1.369 mGy on the beam condition for the best image quality, 0.051 mAs, which is much less than DRLs recommended by IAEA (International Atomic Energy Agency) and KDFA, both. Its dose distribution in the x-ray field size was observed to be uniform with standard deviation of 5~10 %. DAP of the new x-ray device was $82.4mGy*cm^2$ less than DRL established by KDFA even though its x-ray field size was small. This study shows that the new x-ray imaging device offers better in image quality and lower radiation dose compared to the conventional intraoral units. In additions, methods and know-how for studies in x-ray features could be accumulated from this work.

Dosimetric Effect on Selectable Optimization Parameters of Volumatric Modulated Arc Therapy (선택적 최적화 변수(Selectable Optimization Parameters)에 따른 부피적조절회전방사선치료(VMAT)의 선량학적 영향)

  • Jung, Jae-Yong;Shin, Yong-Joo;Sohn, Seung-Chang;Kim, Yeon-Rae;Min, Jung-Wan;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.15-25
    • /
    • 2012
  • The aim of this study is to evaluate plan quality and dose accuracy for Volumetric Modulated Arc Therapy (VMAT) on the TG-119 and is to investigate the effects on variation of the selectable optimization parameters of VMAT. VMAT treatment planning was implemented on a Varian iX linear accelerator with ARIA record and verify system (Varian Mecical System Palo Alto, CA) and Oncentra MasterPlan treatment planning system (Nucletron BV, Veenendaal, Netherlands). Plan quality and dosimetric accuracy were evaluated by effect of varying a number of arc, gantry spacing and delivery time for the test geometries provided in TG-119. Plan quality for the target and OAR was evaluated by the mean value and the standard deviation of the Dose Volume Histograms (DVHs). The ionization chamber and $Delta^{4PT}$ bi-planar diode array were used for the dose evaluation. For treatment planning evaluation, all structure sets closed to the goals in the case of single arc, except for the C-shape (hard), and all structure sets achieved the goals in the case of dual arc, except for C-shape (hard). For the variation of a number of arc, the simple structure such as a prostate did not have the difference between single arc and dual arc, whereas the complex structure such as a head and neck showed a superior result in the case of dual arc. The dose distribution with gantry spacing of $4^{\circ}$ was shown better plan quality than the gantry spacing of $6^{\circ}$, but was similar results compared with gantry spacing of $2^{\circ}$. For the verification of dose accuracy with single arc and dual arc, the mean value of a relative error between measured and calculated value were within 3% and 4% for point dose and confidence limit values, respectively. For the verification on dose accuracy with the gantry intervals of $2^{\circ}$, $4^{\circ}$ and $6^{\circ}$, the mean values of relative error were within 3% and 5% for point dose and confidence limit values, respectively. In the verification of dose distribution with $Delta^{4PT}$ bi-planar diode array, gamma passing rate was $98.72{\pm}1.52%$ and $98.3{\pm}1.5%$ for single arc and dual arc, respectively. The confidence limit values were within 4%. The smaller the gantry spacing, the more accuracy results were shown. In this study, we performed the VMAT QA based on TG-119 procedure, and demonstrated that all structure sets were satisfied with acceptance criteria. And also, the results for the selective optimization variables informed the importance of selection for the suitable variables according to the clinical cases.

Diagnosis of Obstructive Sleep Apnea Syndrome Using Overnight Oximetry Measurement (혈중산소포화도검사를 이용한 폐쇄성 수면무호흡증의 흡증의 진단)

  • Youn, Tak;Park, Doo-Heum;Choi, Kwang-Ho;Kim, Yong-Sik;Woo, Jong-Inn;Kwon, Jun-Soo;Ha, Kyoo-Seob;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.9 no.1
    • /
    • pp.34-40
    • /
    • 2002
  • Objectives: The gold standard for diagnosing obstructive sleep apnea syndrome (OSAS) is nocturnal polysomnography (NPSG). This is rather expensive and somewhat inconvenient, however, and consequently simpler and cheaper alternatives to NPSG have been proposed. Oximetry is appealing because of its widespread availability and ease of application. In this study, we have evaluated whether oximetry alone can be used to diagnose or screen OSAS. The diagnostic performance of an analysis algorithm using arterial oxygen saturation ($SaO_2$) base on 'dip index', mean of $SaO_2$, and CT90 (the percentage of time spent at $SaO_2$<90%) was compared with that of NPSG. Methods: Fifty-six patients referred for NPSG to the Division of Sleep Studies at Seoul National University Hospital, were randomly selected. For each patient, NPSG with oximetry was carried out. We obtained three variables from the oximetry data such as the dip index most linearly correlated with respiratory disturbance index (RDI) from NPSG, mean $SaO_2$, and CT90 with diagnosis from NPSG. In each case, sensitivity, specificity and positive and negative predictive values of oximetry data were calculated. Results: Thirty-nine patients out of fifty-six patients were diagnosed as OSAS with NPSG. Mean RDI was 17.5, mean $SaO_2$ was 94.9%, and mean CT90 was 5.1%. The dip index [4%-4sec] was most linearly correlated with RDI (r=0.861). With dip index [4%-4sec]${\geq}2$ as diagnostic criteria, we obtained sensitivity of 0.95, specificity of 0.71, positive predictive value of 0.88, and negative predictive value of 0.86. Using mean $SaO_2{\leq}97%$, we obtained sensitivity of 0.95, specificity of 0.41, positive predictive value of 0.79, and negative predictive value of 0.78. Using $CT90{\geq}5%$, we obtained sensitivity of 0.28, specificity of 1.00, positive predictive value of 1.00, and negative predictive value of 0.38. Conclusions: The dip index [4%-4sec] and mean $SaO_2{\leq}97%$ obtained from nocturnal oximetry data are helpful in diagnosis of OSAS. CT90${\leq}$5% can be also used in excluding OSAS.

  • PDF

The study on the entry of dental technicians in the public health center for a manpower supply and demand plane (Centering around a denture insurance policy in 2012) (인력수급 대책을 위한 치과기공사의 보건지소 진출에 관한 연구 - 2012년 틀니보험화 정책을 중심으로 -)

  • Lee, Jong-Do;Kim, Jeong-Sook;Park, Kwang-Sig
    • Journal of Technologic Dentistry
    • /
    • v.32 no.4
    • /
    • pp.417-433
    • /
    • 2010
  • Purpose: This study evaluated the manpower planning of dental technicians. Methods: Methods : Survey was conducted regarding subject's general characteristics, characteristics of dental technician's occupational view and working conditions, and reason to enter into branches of the public health enter. The survey sample consisted of 323 dental technicians (221 male/ 102 female). Survey was conducted for one month from August 1 to September 1 in 2010. Following results were obtained. Results: 1. Regarding general characteristics of the subjects, there was a slight male predilection with 68.4%. Subjects in their 40s occupied the highest proportion of 32.2%. Majority of subjects worked in the big cities (71.5%). Favored working places were dental laboratory (57.6%) and dental hospital or dental clinic (19.5%). Although no position is available in the public sector such as public health center or health care civil servant, 9.3% preferred working in the public health center. Public sector is more favored than 2-year technical colleges or dental supply and equipment companies. In respect to education, 57% of the subjects graduated college. 67.8% were married. Subjects who specialize in the porcelain or all-ceramic were 57.9%. With regard to current position, head of the dental laboratory was most common. 2. Following occupation characteristics were found. Economic reason took the highest proportion when deciding their occupation (39.9%) followed by gaining social experience (36.5%). Majority of the subjects (76.5%) wanted to work as dental technicians until their retirement. 71.5% pursuit to become a manager of the dental laboratory. 76.1% agreed on opening a dental technician position in the public health center. Regarding an authority to lead developing the dental technician position in the public sector, majority of the subject chose ministry of health and welfare (35.6%) and Korean dental technologist association (34.7%). Employment (average, 30%) and turnover rate (average, 36.5%) of dental technology college graduates ranged from 40% to 60%. Most important factors for the employment were practical experience (41.2%) and competency (34.4%). With regard to job satisfaction, so-so as 46.7% and satisfactory was 42.7% 3. In respect to the reason for opening a position in the public health center, 'It is needed to continue denture rogram for elderly patients' obtained the highest score (4.14 point). 'Institutional devices are required to open a position for dental technicians as a public healthcare provider' received high score (4.11 point). 4. Concerning the working conditions, 'professional knowledge is required' received the highest score (4.23) followed by 'too short maternity and parental leave' (4.21). 5. Relationship between general characteristics of the subjects and favor of working in the public health center was investigated. Significant differences were found according to the current and favored working area, favored occupation, education level, marital status, and specialty. Working in the public health center was favored by following subjects: working in mid- or small-sized cities (4.16 point, p<0.05); PhD degree-holder (4.59 point, p<0.01). 6. Among general characteristics of the subjects, significant difference of working conditions was found in the following factors: gender; working areas; favored working areas; favored working positions, and education level. Majority of subjects favored working in big cities and currently work in big cities although satisfaction was comparatively low (3.75 score). 7. Future plan to work in public health center was evaluated according to occupational characteristics. Subject's intention to work in the public healthcare center was significantly affected by opening of dental technician position, leading authority, average turnover rate, and factors affecting employment. Working in the public health care center was favored by the following subjects: Dental technicians who actively supported opening of the dental technician position (4.34 point, p<0.001); subjects who thought the Korean dental technologist association is responsible for the opening of positions in the public sector (4.26 point, p<0.001); and subjects who thought that attitude and character are important for the employment (p<0.001). 8. Concerning difference of working conditions according to the occupational characteristics, significant difference was demonstrated by factors such as a reason to choose to be a dental technician, work plan, pursuing position, responsible authority, average employment rate, and job satisfaction. High standard of working conditions was required in subjects who selected to be a dental technician for the leisure time after work (s.05 point, p<0.01), who planted to work until their marriage (4.25 point, p<0.001), and who pursuit to be a manager (3.98, p<0.05). 9. In respect to influence of general characteristics on the advancement to public health centers, the coefficient of determination (R2) was 0.068 and age affected the working condition with significant difference according to the pvalue. 10. Regarding influence of general characteristics on the advancement to public health centers, the coefficient of determination (R2) was 0.335 and work plan, opening of dental technician position in the public sector, and responsible authority had significant influence over the subject's intention to work in the public health center according to the p-value. 11. With regard to the influence of general characteristics on the advancement to public health centers, the coefficient of determination (R2) was 0.091 and reason to choose to be a dental technician, work plan, and responsible authority significantly affected subject's working conditions. Conclusion: Korean society is becoming a super-aged society according to several statistics. As aged population is rapidly increasing, national health insurance plans to cover denture for senior citizen over 75 years old from 2012. Therefore, dental technicians are urgently needed in the public health centers all over the nation. Many subjects in this study planed to work until their retirement and recognized dental technician's expertise. Ministry of health and welfare and Korean dental technologist association should co-operate each other to prepare foundation and institutional devices for dental technicians to advance into the public health center. This will improve oral health of the population. This study showed urgency of medical facilities and services which meets increasing number of aged population and welfare of the population.