• Title/Summary/Keyword: Standard test method

Search Result 2,907, Processing Time 0.029 seconds

Comparison of General Test Methods of Various Organs on Synthetic Food Colors (여러 기관의 일반시험법에 의한 식용 타르색소의 규격 비교 시험)

  • Shin Dong-Hwa;Kim Yong-Suk;Lee Young-Hwan;Bang Jeong-Ho;Om Ae-Son;Shin Jae-Wook;Lee Tal-Soo;Hong Ki-Hyoung;Park Sung-Kwan;Choi Jang-Duck;Kim Hee-Yun
    • Journal of Food Hygiene and Safety
    • /
    • v.19 no.4
    • /
    • pp.171-175
    • /
    • 2004
  • An analytical method of nine synthetic food colors in Korea, Japan, Joint FAO/WHO Expert Committee of Food Additives (JECFA), and USA were compared. Contents of water insoluble matter in synthetic food colors tested were not different by general test methods of various organs. Contents of chloride and sulfate salts in Food Green No.3, Food Red No.3, Food Blue No.2, and Food Yellow No.4 slightly differed in various methods, and but up to the standard, and general test methods of JECFA and USA needed far more time. For the measurement of arsenic contents in food colors, colorimetric method in Korea and Japan, and silver diethyldithiocarbamate colorimetric method in USA and JECFA were used, but the standards of them were different. Content of heavy metals was up to the standard, but the methods were used colorimetric method in Korea, atomic absorption method in Japan, and both methods in JECFA and USA.

A Method for Determining the Sandstone Porosity by Using a Microwave Oven (마이크로웨이브 오븐을 이용한 사암의 공극률 산출 방법)

  • Woo, Seulgi;Kim, Jinhoo
    • Journal of the Korean earth science society
    • /
    • v.38 no.2
    • /
    • pp.150-160
    • /
    • 2017
  • In order to determine the porosity of rock, the 'standard test method for porosity and density of rock' proposed by the Korean Society for Rock Mechanics is commonly used. However, the standard test method, which uses a drying oven, takes 8 to 24 hours to complete the test in taking samples out of the oven every four hours and measuring the weight of the specimen. To complement these disadvantages, we devised a method for measuring rock porosity by using a microwave oven. The devised method reduced the cause of errors and the inconvenience occurred in the process of weighing samples by constructing a weight monitoring system, which monitors the drying process. A suitable heating/pause time was set up to maintain the temperature of sample below $105{\pm}3^{\circ}C$ in drying process, and an alarm system was implemented in order to stop drying process when the weight change of the rock sample is within 0.1% of the initial weight. The porosity was determined from the dry weight of the sample, which was obtained by the curve fitting of weight monitoring data. Then, the porosities obtained by using the microwave oven were compared with those obtained by the standard test method. Test results using sandstone samples showed that the porosities obtained by a microwave oven was similar to those obtained by the standard method and the porosity difference between two methods was as large as 0.4%. In addition, repeated porosity measurement using the same specimen showed that the standard deviation of the porosity, which reflects the precision of the measurement was as good as 0.23%. Therefore, a microwave oven porosity measurement system can give the porosity of rock samples with high reliability.

Automatic Threshold-decision Algorithm using the Average and Standard Deviation (평균과 표준편차를 이용한 자동 임계치-결정 알고리즘)

  • Ko, Kyong-Cheol;Rhee, Yang-Won
    • The Journal of Korean Association of Computer Education
    • /
    • v.8 no.6
    • /
    • pp.103-111
    • /
    • 2005
  • This paper presents a novel automated threshold-decision algorithm that uses the mean and standard-deviation values obtained from the difference values of consecutive frames. At first, the calculation of difference values is obtained by the weighted ${\chi}^2$-test algorithm which was modified by joining color histogram to ${\chi}^2$-test algorithm. The weighted ${\chi}^2$-test algorithm can subdivide the difference values by imposing weights according to NTSC standard. In the first step, the proposed automatic threshold-decision algorithm calculates the mean and standard-deviation value from the total difference values, and then subtracts the mean value from the each difference values. In the next step, the same process is performed on the remained difference values, and lastly, the threshold is detected from the mean when the standard deviation has a maximum value. The proposed method is tested on various video sources and, in the experimental results, it is shown that the proposed method efficiently estimates the thresholds and reliably detects scene changes.

  • PDF

Improvement of waste landfill by dynamic compaction method (동다짐공법에 의한 쓰레기매립지반의 개량특성 분석)

  • 정하익;곽수정
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.10a
    • /
    • pp.404-410
    • /
    • 2002
  • Dynamic compaction is an efficient ground improvement technique for loose soils and waste landfill. The improvement is obtained by controlled high energy tamping and its effects vary with the soil properties and energy input. This study demonstrated the application of dynamic compaction method for the improvement of waste landfill in construction site. Various tests and measurements such as standard penetration test, bore hole loading test, crater settlement, ground settlement, pore water pressure were peformed during dynamic compaction field test. From the field test results, the efficiency of dynamic compaction method for the improvement of waste landfill was proved.

  • PDF

Development of gripping force and durability test standard for myoelectric prosthetic hand (근전전동의수의 파지력 및 내구성 시험 표준 개발)

  • Gook Chan Cha;Suk-Min Lee;Ki-Won Choi;Sangsoo Park
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.393-399
    • /
    • 2023
  • Upper limb amputees wear an upper limb prosthesis for both aesthetic purposes and functional necessity, and in particular, in the case of amputee with both hands, it is essential to wear a myoelectric prosthetic hand capable of gripping action. The prosthetic hand operated by the EMG signal of the remaining muscles is a public insurance benefit item of the Industrial Accident Compensation Insurance, and test method standards are needed to be developed for the safety of the user and the effectiveness of the product performance. In this study, we developed systems for measuring the gripping force of myoelectric hand prosthesis by a load cell and for durability test of the prosthesis over repeated use with a proximity sensor, and propose a test method standard. Since the international test method standard has not yet been established, it is expected that Korea will be able to play a leading role in this standardization field in the future.

Construction of Korean Korea CALS Standardization (한국적 CALS 표준화 구축방안)

  • 김철환;김규수;신영인
    • The Journal of Society for e-Business Studies
    • /
    • v.1 no.1
    • /
    • pp.117-140
    • /
    • 1996
  • CALS is recognized as a national response to the new chapter of information society. It is essential that the standardization in Korea should be constructed compatible with not only domestic but also international standardization trend. This study aims to propose a proper direction of CALS standardization in Korea, based on the international CALS standardization movement. This paper classifies standard into five types and provides a proper direction and guidance far each standard. As a trend of CALS standard, all ten data files are converted using SGML standard far the interchangeability of data among heterogenous systems. CAD and Graphic data arc also moving toward to the STEP as their standard. In this regard, this paper discusses how to implement SGML and STEP Model. Finally, this paper proposes a method how to construct an EDI system with CALS standard and how to establish a standard authorization institute which will be responsible far the standard authorization. Furthermore, this paper also proposes the CALS Test Network (CTN) as its experimental method.

  • PDF

REVIEW OF DYNAMIC LOADING J-R TEST METHOD FOR LEAK BEFORE BREAK OF NUCLEAR PIPING

  • Oh, Young-Jin;Hwang, Il-Soon
    • Nuclear Engineering and Technology
    • /
    • v.38 no.7
    • /
    • pp.639-656
    • /
    • 2006
  • In order to apply the leak before break (LBB) concept to nuclear piping systems, the dynamic strain aging effect of low carbon steel materials has to be taken into account, in compliance with the requirements of the Korean Standard Review Guide (KSRG) 3.6.3-1. For this goal, J-R tests are needed for a range of various temperatures and loading rates, including dynamic loading conditions. In the dynamic loading J-R test, the unloading compliance method can not be applied to measure the crack growth and direct current potential drop (DCPD) method; this method also has a problem defining the crack initiation point. The normalization method is known as a very useful method to determine the J-R curve under dynamic loading because it does not need additional equipment or complicated loading sequences such as electric current or unloading. This method was accepted by the American Society for Testing and Materials (ASTM) as a standard test method E1820 A15 in 2001. However, it has not yet been clearly verified yet if the normalization method is sufficiently reliable to be applied to LBB. In this study, the basic background of the J-integral, LBB and dynamic loading J-R test are explained, and the current status for dynamic loading J-R test methods are reviewed from the view point of LBB for nuclear piping. In particular, the theoretical and historical background of the normalization method which has received attention recently, is summarized. Recent studies for this method are introduced and future works are suggested that may improve the reliability of LBB for nuclear piping.

Evaluation of Ground Improvement on Sands at Yongjong Island Geotechnical Experimental Site (영종도 지반공학 야외시험장에서의 사질토지반 개량효과 평가)

  • 김동수;박형춘;김영웅;김수일
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.03a
    • /
    • pp.439-446
    • /
    • 1999
  • In situ experimental studies were Performed at Yongjong Island Geotechnical Experimental Site to evaluate the ground densification on sand deposited. Standard penetration test, cone penetration test, and SASW test were performed and soil profiles and quality of ground improvements were evaluated. The feasibility of applying SASW method were verified by comparing test results. The evaluation technique of in-situ density using SASW and resonant column tests was proposed, and the reliability of proposed method was verified by performing case studies.

  • PDF

Laboratory tests on noise emission from appliances and equipment used in water supply installations Part 1: Method of measurement (급수기구 발생음의 실험실 측정방법 제1부 : 측정방법)

  • 양관섭;정갑철;김선우
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.845-850
    • /
    • 2003
  • Noise caused by water installations may lead to annoyance in adjacent rooms, for example in dwellings. hospitals and hotels. This part of standard describes a method of measurement allowing comparable results to be obtained in laboratory measurements. The test conditions described herein constitute the standard reference conditions essential for comparisons between laboratories.

  • PDF

Reliability evaluation plan of Rocket motor system (추진기관 시스템의 신뢰성 평가 방안)

  • Sim, Haeng-Geun;Jang, Ju-Su
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2011.06a
    • /
    • pp.305-309
    • /
    • 2011
  • Reliability evaluation of One-Shot systems which fly at speed of Mach must evaluate as the result which leads a many firing test. But many firing test the fact that is impossible is actuality with problem of budget. Method of prediction leads consequently with alternative and will be able to present the alternative which evaluates. Prediction of One-Shot systems that how many did accumulate a many experience data according to the accuracy is decided, there is a possibility of seeing. One like shot our country and the method which is indirect leads from the environment where the test data is insufficient and only will not be able to set the direction of prediction, the present paper about such method describes 217 Plus where is a reliability prediction standard which is new the thing in standard.

  • PDF