• Title/Summary/Keyword: Standard solution

Search Result 1,940, Processing Time 0.038 seconds

Glomerular Filtration Rate Test Methods and Guidelines (Glomerular Filtration Rate 검사방법 및 가이드라인)

  • Park, Min-Ho;Lee, Ha-Young;Ryu, Hwa-Jin;Yoo, Tae-Min;Noh, Gyeong-Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.97-100
    • /
    • 2018
  • Purpose The glomerular filtration rate (GFR) test is an important indicator of glomerular filtration and has been used to test renal function and the extent of its function. The GFR test is performed by intravenous injection of radioactive medicines made of $^{51}Cr$-EDTA, and blood concentration is measured by taking blood according to the elapsed time. also, PET-CT, bone scan, transfusion and so on will affect the outcome. Therefore, we will improve the quality of the test by providing guidelines for the GFR test for more accurate testing. Materials and Methods 5 mL of physiological saline solution and 2 mL of $^{51}Cr$-EDTA solution are used to make 5 mL of the radiopharmaceutical solution to be injected into the patient. First, the syringe weight is measured before the injection, and then the radioactive medicine is injected into the patient's vein and the syringe weight is measured after the injection. Blood sampling is performed twice in total. In adults, blood is collected 3 hours / 5 hours after injection and in children 2 hours / 5 hours after injection. The blood sample is centrifuged at 3300 rpm for 5 minutes. Standard solution is prepared by filling diluent water up to the scale indicated in the 200-mL volumetric flask, discarding $500{\mu}L$, injecting $500{\mu}L$ of GFR reagent and mixing well. $500{\mu}L$ each of the standard solution is dispensed into two test tubes, and $500{\mu}L$ of each of the plasma samples collected in time is dispensed into two test tubes and measured with a Cobra Counter. Results At present, the reference range applied in this study is $119.5{\pm}30.3ml/min/1.73m2$ for males and $125.2{\pm}28.2ml/min/1.73m^2$ for females. Conclusion The GFR test is conducted using radioactive medical products. GFR testing is performed as a scheduled test, but PET-CT, dialysis and transfusion, which may affect GFR testing, may be scheduled during GFR testing. Therefore, we could get accurate GFR test results by notifying the ward and department beforehand when booking.

An Improved Multiresolution Technique to Reconstruct Magnetoencephalography(MEG) Source Distribution

  • Im, Chang-Hwan;An, Kwang-Ok;Jung, Hyun-Kyo;Lee, Yong-Ho;Kwon, Hyuk-Chan
    • International Journal of Control, Automation, and Systems
    • /
    • v.1 no.3
    • /
    • pp.385-389
    • /
    • 2003
  • In this paper, an improved technique for multiresolutive reconstruction of magnetoencephalography (MEG) source distribution is proposed. Using the proposed technique, focal solution with higher energy density can be reconstructed. Moreover, the proposed approach is very easy to implement compared to conventional ones. The usefulness of the proposed technique is verified by the application to a real brain model.

Design of BACnet/Zigbee Intrated System (BACnet/Zigbee 통합 시스템의 설계)

  • Kim, Se-Hwan;Park, Dong-Kyu;Hong, Seung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.6
    • /
    • pp.1063-1068
    • /
    • 2008
  • BACnet(Building Automation and Control Networks) is a standard data communication protocol specifically designed for building automation and control systems, BACnet provides six options for data link layer protocols and these six data link layer options can be applied with various wired transmission media. Recently wireless technology prevails in automation area. ZigBee is an IEEE 802.15.4 based standard communication protocol for low-rate wireless personal area networks. In this study, we propose a BACnet over ZigBee model that adopts ZigBee communication channel as a wireless data link layer protocol in a BACnet-based communication network system. The technology proposed in this paper can expand the BACnet application using the advantages of wired and wireless integrated network solution.

Linear-Quadratic-Gaussian Regulators with Moving Horizons (가변경계조건을 갖는 새로운 칼만필터 및 레규레이터 구성)

  • Kwon, W.H.;Park, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 1979.08a
    • /
    • pp.80-82
    • /
    • 1979
  • While the standard linear-quadratic-Gaussian problem has fixed horizons, this paper considers the LQG problem with moving horizons. By the separation principle the solution will be given by the kalman filter with the approaching horizon and the LQ regulator with the receding horizon. Sufficient conditions on weighting matrices are derived under which the filter and regulator are asymptotically stable. It wall be shown that the computation method of the moving-horizon LQG regulators is better than that of the standard LQG regulator. The performance measure between the two optimal controls will be compared. A simulation result is given in order to show the usefulness of the moving-horizon LQG regulator.s

  • PDF

Toxicological Studies on the Humic acid (Humic acid의 독성학적 연구)

  • 라규환
    • Environmental Analysis Health and Toxicology
    • /
    • v.2 no.1_2
    • /
    • pp.13-16
    • /
    • 1987
  • The author obtained three kinds of humic acid from the soil of suburbs in the Wonju city, sediments of Wonju stream and Maeji reservoir in 29 April 1986. The yield of each humic acid was 7.23 g, 3.35 g and 4.61 g per sample 200 g. In the physicochemical characters, the COD varied from 65.9 ppm to 54.9 ppm and BOD showed 6.7~15.9 ppm, but the standard humic acid was COD 58.9 ppm and BOD 6.5 ppm in 0.01 % solution. Doses of the humic acids for 20% methemoglobin formation are as follows; 0.303 mg/m$\ell$ in St. A humic acid, 0.602 mg/m$\ell$ in St. B humic acid, 0.84 mg/m$\ell$ in St. C humic acid and 0.105 mg/m$\ell$ in standard humic acid.

  • PDF

The Properties of Hardened Slag by Alkali and Curing Method (알칼리 첨가 및 양생방법에 따른 슬래그 경화체의 특성)

  • 김원기;소정섭;배동인
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.27-32
    • /
    • 2002
  • In this research influences of type and concentration of alkali activator and curing condition on the hydration, and properties of alkali activated blast furnace slag(AAS) concrete were investigated. Sodium carbonate and sulfate were used as alkali activators and their concentration were 4~10 weight percent with Na$_2$O equivalent to binder. The curing conditions were standard curing using 23$^{\circ}C$ water and activated curing chamber at $65^{\circ}C$. Results show that in case of sodium carbonate addition high early strengths were gained by activation of early hydration, but later strength gained was slight. On the other side sodium sulfate strengths were continuously increased with adding amount and ages. Steam curing activated early hydration so that early strengths were improved but later strengths were similar to standard curing. The strength reduction of AAS mortar with sodium sulfate was less than OPC mortar in 5% sulfuric acid solution so that AAS concrete can be useful for acid-resistance concrete.

  • PDF

Continuous Processing of Monodispersed Zirconia Powders (초음파 혼합 연속공정에 의한 단분산 지르코니아 분체의 합성)

  • Rhee, Jhun;Jo, Dong-Soo
    • Journal of the Korean Ceramic Society
    • /
    • v.29 no.12
    • /
    • pp.919-925
    • /
    • 1992
  • Continuous synthesis process for monodispersed zirconia powders with ultrasonic wave mixing was developed. Reactant solutions were flowed through a T-tube with small diameter and then mixed in a microscale with ultrasonification. Reaction and aging were followed during the mixed solution of reactants is in plug flowing through a narrow long teflon tubing. Zr(n-OC4H9)4 in ethanol and H2O in ethanol were used as reactants. From this process monodispersed, spherical, non-agglomerated, singlet hydrated zirconia powders with 0.6 $\mu\textrm{m}$ average size were obtained. Geometrical standard deviation of the particle size distribution was less than 1.2 with ultrasonic mixing, and the geometrical standard deviation was not affected by the flow rate of the reactants.

  • PDF

Determination of Boron Steel by Isotope-Dilution Inductively Coupled Plasma Mass Spectrometry after Matrix Separation

  • Park, Chang-J.
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.11
    • /
    • pp.1541-1544
    • /
    • 2002
  • The concentration of B in steels is important due to its influence on mechanical properties of steel such as hardenability, hot workability, and creep resistance. An analytical method has been developed to determine B in steel samples by high-resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). National Institute of Standard and Technology Standard Reference Material (NIST SRM) 348a was analyzed to validate the analytical method. The steel sample was digested in a centrifuge bottle with addition of aqua regia and $^{10}B$ spike isotope. Sample pH was then adjusted to higher than 10 to precipitate most matrix elements such as Fe, Cr, and Ni. After centrifugation, the supernatant solution was passed through a cation exchange column to enhance the matrix separation efficiency. B recovery efficiency was about 37%, while matrix removal efficiency was higher than 99.9% for major matrix elements. The isotope dilution method was used for quantification and the determined B concentration was in good agreement with the certified value.

Clinical Application of Pulmonary Vein Wedge Angiography (Pulmonary Vein Wedge Angiography 의 임상적 이용)

  • 문경훈
    • Journal of Chest Surgery
    • /
    • v.20 no.3
    • /
    • pp.544-547
    • /
    • 1987
  • Pulmonary vein wedge angiography was applied to two patients of 2 years old TOF with PFO. Left pulmonary artery was not visualized by standard right ventriculogram and catheter was not entered into main pulmonary artery. Through PFO and left atrium, pulmonary vein wedge angiography at left lower pulmonary vein was done. The ipsilateral pulmonary artery & its trees in both cases and the contralateral pulmonary artery in one case were well visualized. Dangerous complication, such as massive bronchoconstriction due to extravasation of contrast material into the bronchus, was not developed. Mild coughing was occurred, but well tolerable in both cases. We recommended a dose of 0.8 mL/Kg of contrast material at a rate of 2 to 3 mL/sec and 1 to 2 mL/Kg of flush solution at the same rate by the hand, and routine use of pulmonary vein wedge angiography in cyanotic patients whose pulmonary artery was not visualized by the standard angiography.

  • PDF

Legal Sources of Fraud Rule and It's Standard in Documentary Credit (화환신용장에서 사기배제법칙의 법원과 표준)

  • Oh, Won-Suk;Kim, Jae-Seong
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.21
    • /
    • pp.99-127
    • /
    • 2003
  • Legal sources of fraud rule in documentary letter of credit, which have their origin in Sztejn Case can be traced to various rules or laws of international or domestic level ; URCG, URDG and ISP98 as ICC Rules, and UNCITRAL Convention as an international uniform law, and UCC as a domestic law and U.K. cases. Among them the combination of "material fraud" in UCC ${\S}5-109$ and the detailed list of the types of misconduct in UNCITRAL Convention may provide the best solution or standard in real application of the fraud rule in letter of credit transaction.

  • PDF