• Title/Summary/Keyword: Standard solution

Search Result 1,940, Processing Time 0.033 seconds

A Study on the Development of Soil-based PTMs for Analysis of Benzo[a]pyrene - Focusing on the Evaluation of Homogeneity and Stability for the Certification of Benzo[a]pyrenecandidate Reference Materials - (Benzo[a]pyrene 분석용 토양 숙련도 표준시료 개발에 관한 연구 - 후보 표준물질의 인증을 위한 균질성, 안정성 평가를 중심으로 -)

  • Lee, Minhyo;Lee, Guntaek;Joo, Changkyu;Kim, Yonghun;Lee, Bupyoel;Choe, Sunghun;Kim, Myeongock;Hong, Sukyoung;Kim, Gumhee;Lee, Wonseok
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.6
    • /
    • pp.49-58
    • /
    • 2014
  • This study was implemented as a part of the experiment to develop two kinds of soil-based Benzo[a]pyrene (BaP) proficiency testing materials (PTMs) for soil analysis. A test was carried out for the check of solubility of the reference material (high purity reagent) using several solvents. Another test was also conducted for the evaluation of homogeneity and stability of two kinds of candidate soil reference materials. The test analysis of BaP in terms of the candidate materials was conducted according to the Standard Soil Analytical Methods by Ministry of Environment. Dissolution of the reference material was shown to vary depending on solvent type and was higher in the order of Dichloromethane > Acetone > Acetone/MeOH (9 : 1) > N-hexane. In addition, the slope on calibration curve for BaP standard solutions was largest on BaP standard solutions prepared with dichloromethane of the tested solvents. Such tendency appeared egually in the commercial BaP standard solution. Therefore, it is thought to be reasonable to use dichloromethane as the solvent in case of the standard stock solution that is used for the measurement of BaP concentration in soil. ISO 13528 and IUPAC protocol were used for verification of homogeneity on the two kinds of soil candidate materials, Both candidate materials were sufficiently homogeneous. Stability assessment of the two candidate materials was made according to ISO Guide 35 and the result showed that both batches did not have any long-term and short term stability issues that might occur during shipping. However, monitoring results of BaP concentration in soil showed that BaP concentration of the two batches measured at 15 days after the sample preparation was reduced by about 24~37% compared with that of the samples measured on 0 day of the sample preparation. Identification was done with several treatments such as irradiation and sterilization etc. The major cause was shown to be irradiation to the samples.

The shelf life of 1,2-indandione/zinc and polyvinylpyrrolidone solutions used to develop latent fingermarks deposited on the surface of thermal paper (감열지에 부착된 잠재지문을 현출하는데 사용하는 1,2-indandione/zinc와 polyvinylpyrrolidone 용액의 보존기한)

  • Hong, Sungwook;Kim, Yujin;Kim, Hyunjung;Kim, Hyerim;Lee, Junchul;Yu, Seoungho
    • Analytical Science and Technology
    • /
    • v.30 no.6
    • /
    • pp.312-318
    • /
    • 2017
  • The shelf life of 1,2-indandione/zinc (1,2-IND/Zn) solution and polyvinylpyrrolidone (PVP) solution, which are known as reagents for developing latent fingermarks deposited on the surface of thermal paper, was studied. The standard latent fingermarks used for comparisons were artificial latent fingermarks printed on thermally sensitive and non-sensitive surfaces with the same intensity. Upon treatment of standard latent fingermarks with the pre-mixed 1,2-IND/Zn and PVP solutions, the fingermarks could be successfully developed until 3 days after the preparation of the mixture. However, from the third day after mixing the reagents, blackening was observed on the surface of the thermal paper, indicating deterioration of the reagent performance. The 1,2-IND/Zn and PVP solutions separately stored without mixing in advance were mixed immediately before use, and the development efficiency of the latent fingermarks deposited on the surface of thermal paper was observed. The performance of the PVP solution decreased after 20 days from the preparation of the reagent. It was also found that the shelf life of 1,2-IND/Zn and PVP mixture was determined by the PVP solution. The effect of oxygen and moisture on the degradation of PVP was investigated. It was found that the performance of the PVP solution deteriorated because of the influence of moisture, though it was not affected by oxygen.

A study on the washing remediation of tailing waste and contaminated surrounding soil of a bandoned metal mines (폐금속광산 광미 및 주변 오염토양 세정에 관한 연구)

  • 이동호;박옥현
    • Journal of Korea Soil Environment Society
    • /
    • v.4 no.2
    • /
    • pp.87-101
    • /
    • 1999
  • This study has been carried out to examine the feasibility of washing technique for reducing the heavy metal contamination level of tailing wastes and agricultural soil surrounding abandoned metal mines. Some organic acids with low molecular weight were used as washing solution. Initial contamination levels of copper and lead for some soil samples were found to exceed the standard levels of countermeasure and concern, and those of cadmium to approach the standard level of countermeasure. Experimental results using sequential extraction method revealed that more than half of copper and lead existing in tailing wastes are adsorbed forms available for plants. There are some proportional relationships between metal concentrations determined by using 0.1N HCI solution and those determined by sequential extractions. Citric acid was turned out to be superior to oxalic acid and acetic acid with low molecular weight in washing above three metals. When citric acid is used for washing heavy metals from soil, it is desirable to operate at pH less than 5.5 for better washing effect. Metal removal effect by citric acid solution has been proved to depend upon solution concentration and the mass ratio of solution to soil. Addition of SDS(Sodium Dodecyl Sulfate) to citric acid improved the washing effect of cadmium among three metal most significantly. while copper removal did not change. Washing technique using citric acid for removal of heavy metals from agricultural soil or tailing wastes is recognized to be an effective remediation method.

  • PDF

Fundamental Studies on the Development of On-line Monitoring of Trace Mercury in Drinking Water (음용수 중 수은 연속자동측정시스템의 개발에 관한 연구)

  • Chang, Soo-Hyun;Kim, Hyo-Jin;Kim, Sun-Tae;Kim, Young-Man
    • Analytical Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.299-305
    • /
    • 1999
  • The electrolyte cathode atomic glow discharge (ELCAD) is a new plasma source for direct determination of trace heavy metals in drinking and waste water. ELCAD has been successfully developed for on-line monitoring of heavy metals, however, shows difficulty to measure mercury. In this study, ELCAD has been modified to apply the atomic absorption spectrometry (AAS) for the direct determination of trace elements of mercury in flowing water.The fundamental characteristics of this new types of plasma source have been investigated and found that the pH of the solution, discharge voltage, and current are most important factors.The absorbance of 1.0 ppm Hg standard solution increases as pH of the solution increases from pH 1.0 to 3.0.However, % RSD of the absorbance also increases as the pH of solution increasesdue to plasma unstability.The detection limits of the standard solution of pH 1.5 and pH 3.0 are about 40 ppb and 10 ppb level, respectively.

  • PDF

A parallel plate viscometer for blood viscosity measurement (혈액점도 측정용 평행판 점도계)

  • Donggil Seo;Kyung Hyun Ahn;Jihoon Kang;Sangsoo Park
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.331-335
    • /
    • 2023
  • As the viscosity of the blood increases, the blood becomes more sticky and difficult to flow, so the possibility of thrombosis increases and the probability of ischemic cerebral infarction increases. The importance of measuring blood viscosity has recently been emphasized for the prevention of circulatory system diseases, and the need for a viscometer capable of easily and accurately measuring blood viscosity has emerged. In this study, the measured values of a viscosity standard solution and an artificial blood by a parallel-plate viscometer ARS-Medi were compared with the those by Ares-G2 of TA instrument, which is internationally recognized for its accuracy and reliability. The viscosity of N44 standard solution, which is a Newtonian solution, was almost perfectly matched between the two instruments at all shear rates. In the case of an artificial blood, which is a non-Newtonian solution, the measured values between the two instruments showed a difference of about 10% at the lowest shear rate 1 rad/s; however, at a clinically significant shear rate of 10 rad/s or higher, the measured values between them were consistent within the error range. We expect that ARS-Medi, a newly developed parallel-plate viscometer for blood, using disposable plates, will be very useful in clinical practice as it improves the convenience and hygiene of blood viscosity measurement.

Effect of ionic Strength of Nutrient Solution on Growth and Yield in Cucumber(Cucumis sativus L.) (양액이온 농도 차이가 오이의 생육과 수량에 미치는 영향)

  • 권병선;정현희;신동영;김학진;임준택;현규환;신정식
    • Korean Journal of Plant Resources
    • /
    • v.16 no.3
    • /
    • pp.223-229
    • /
    • 2003
  • This study was carried out to investigate the optimum ionic strength of nutrient solution were treated with a quarter, a half, three quarters, standard, one and half, and double ionic strength of balanced nutrient solution of Yamazaki solution recommended for cucumber plants. Plant height and number of loaves of growing period were rapidly increased in 1/2 ionic strength of nutrient solution. Growth characteristics of cucumber plant as affected by the different ionic strength of nutrient solution were not significant differences, however, in the growing period, plant height, stem length and leaf area were highest in 1/2 ionic strength of nutrient solution. Fruit yield of cucumber plant as affected by the different ionic strength of nutrient solution was not significant differences, however, fruit yield was highest in 1/2 ionic strength of the lowering ionic strength of nutrient solution. Nitrogen concentration was not significant differences, however, it was high corcentration in 1/2 ionic strength of nutrient solution. Growth and yield characteristic of cucumber as affected by 1/2 ionic strength of nutrient solution at 36 days transplanting analyzed correlation cofficient. Plant height showed positive correlated with number of plant and positive correlated with yield.

Effects of Compost Leachate and Concentrated Slurry on the Growth and Yield of Pepper in a Substrate Hydroponic Culture (퇴비단 여과액비와 막분리 농축액비를 이용한 고형배지경 양액재배가 고추의 생육과 수량에 미치는 영향)

  • Ryoo, Jong-Won
    • Journal of Animal Environmental Science
    • /
    • v.15 no.2
    • /
    • pp.161-170
    • /
    • 2009
  • This experiment was conducted to investigate the effects of compost leachate and concentrated pig slurry on growth of pepper in substrate hyrdoponic culture. In process of composting, compost leachate was was through a saturated compost heap. Pig slurry was filtered by ultra filtration and concentrated by reverse osmosis process. The pig slurry was mixed with chemical nutrient solution and byproduct based on nitrogen content. Peppers were grown in the seven different hydroponic solutions; compost leachate (CL), concentrated pig slurry (CS), compost leachate + byproduct (CL+BP), concentrated pig slurry + byproduct (CS+BP), compost leachate 50% + nutrient solution 50% (CL+NS), concentrated pig slurry 50% + nutrient solution 50% (CS+NS) and chemical nutrient solution for pepper. The chemical nutrient solution was the standard solution of National Horticulture Research Station for the growth of pepper. The concentration of nutrient solution was adjusted $1.6{\sim}2.0mS/cm$ in EC. The compost leachate and concentrated pig slurry were low in phosphorus (P), calcium (Ca), magnesium (Mg), but rich in potassium (K). Growth characteristics as affected by the different nutrient solution were significantly different. Growth and fruit characteristics treated with CL 50+NS 50%CS and 50+NS 50% were similar with NS 100% control plot. The dry weight of stem and leaf were 107.4, 104.2g in plot of NS 100% and CS 50%+NS 50%, respectively. The fruit of pepper showed lowest in the plot treated with 100% concentrated pig slurry, and the growth of pepper severely decreased after application of 100% CS treatment. The yield of pepper was not significantly different between the plots treated with mixture of CS50 + NS50% and 100% nutrient solution treatment. Fruit yield of the compost leachate concentrated pig slurry plot were 59, 14% compared to control, repectively. In conclusion, the mixture solution of 50% of pig slurry and 50% of nutrient solution could be used as a nutrition solution of pepper in hydroponic culture.

  • PDF

Improvement method for viscosity measurement of high viscosity paper and fabric cultural heritages (고점도 지류 및 섬유 문화재의 점도 측정 개선 방법 연구)

  • Kim, Young-Hee;Hong, Jin-Young;Jo, Chang-Wook;Kim, Soo Ji;Lee, Jeung-Min;Seo, Min Seok;Choi, Kyoung Hwa
    • 보존과학연구
    • /
    • s.34
    • /
    • pp.20-29
    • /
    • 2013
  • Paper, textile and wood materials are mainly consisted of cellulose. Cellulose is high molecule and make up the strong crystalline structure by hydrogen bonds. In particular, the polymerization degree of cellulose are closely related to the strength of fiber, and the permanence. the useful life of fiber, also depends on the degradation of this substance. The viscosity of cellulose is considered to be an important indicator of fiber damage in high molecule polymers. The viscosity measurements with CED solution is used to measure the molecular weight and the degree of polymerization of cellulose. Cellulose viscosity of wood fibers is measured with TAPPI standard method T230. However, TAPPI standard method T230 is difficult to completely dissolving the cellulose of high molecular weight and large degree of polymerization, such as Korea traditional papers and fabrics made with mulberry, ramie, cotton fibers. In this study, The high viscosity of hanji and fabric was measured with TAPPI standard method T254. T254 method is that the cellulose specimen with the proper amount of weaker (0.167M CED) solution, and completely dissolved with the stronger (1.0M CED) solution. It was found that cellulose with high degree of polymerization was dissolved more easily in general CED method.

  • PDF

Current Research Trend of Postharvest Technology for Chrysanthemum (국화 수확 후 관리기술의 최근 연구 동향)

  • Kim, Su-Jeong;Lee, Seung-Koo;Kim, Ki-Sun
    • Korean Journal of Plant Resources
    • /
    • v.25 no.1
    • /
    • pp.156-168
    • /
    • 2012
  • Chrysanthemum is a cut flower species that normally lasts for 1 to 2 weeks, in some cases 3-4 weeks. This has been attributed to low ethylene production during senescence. Reduction in cut flower quality has been attributed to the formation of air embolisms that partially or completely blocks the water transport from the vase solution to the rest of the cut flower stem, increasing hydraulic resistance which may cause severe water stress, yellowing, wilting of leaf, and chlorophyll degradation. Standard type chrysanthemum can be harvested when buds were still tightly closed and then fully opened with the simple bud-opening solution. Standard type chrysanthemum can also be harvested when the minimum size of the inflorescence is about 5-6 cm bud which opened into the first flower full-sized flower. While spray varieties can be harvested when 2-4 most mature flowers have opened (40% opening). Cut flowers are sorted by stem length, weight, condition, and so on. Standard chrysanthemum is 80 cm length for standard type and 70cm for spray type. Pre-treatment with a STS, plant regulator such as GA, BA, 1-MCP, chrysal, germicide, and sucrose, significantly improved the vase life and quality of cut flowers. It is well established that vase solutions containing sugar can improve the vase life of cut chrysanthemum. Chrysanthemum is normally packed in standard horizontal fiberboard boxes. Chrysanthemum should normally be stored at $5{\sim}7^{\circ}C$. Precooling resulted in reduction in respiration, decomposition, and transpiration activities as well as decoloration retardation. There was significant difference between "wet" storage in 3 weeks and "dry" storage in 2 weeks. In separate pulsing solution trials, various germicides were tested, as well as PGRs to maintain the green color of leaves and turgidity. Prolonging vase life was attained with the application of optimal solution such as HQS, $AgNO_3$, GA, BA and sucrose. This also retarded senescence in leaves of cut flower stems. Fresh cut chrysanthemum can be transported using a refrigerated van with $5{\sim}7^{\circ}C$. Increasing consumption and usage of cut chrysanthemum of various cultivars would require efficient transport system, and effective information exchange among producer, wholesaler, and consumer.

Flux Decline Behavior in Cross-flow Microfiltration of Inorganic Colloidal Suspensions (무기 콜로이드 현탁액의 십자류 정밀여과에 의한 투과유속의 감소거동)

  • Nam Suk-Tae;Han Myeong-Jin
    • Membrane Journal
    • /
    • v.15 no.4
    • /
    • pp.338-348
    • /
    • 2005
  • The permeate flux decline on microfiltration capillary membrane operation was investigated with inorganic colloidal solutions. The permeate flux of the alumina solution is two times higher in average than that of the bentonite solution. The flux decline with increase in operation time was less in the alumina solution than in the bentonite solution. The rate of initial flux decline until 10 min was higher on the bentonite solution over the alumina solution. The decline in permeate flux was due to both the cake formation and the pore blocking. The latter effect was higher in the operation of the bentonite solution. In comparing the ratio of each fouling component to the total fouling fur the $1.0\;kg_f/cm^2$ TMP condition, complete blocking was $9.35\%$, standard blocking was about $6.82\%$ and cake filtration was $83.83\%$, respectively. With the increase in cross flow velocity, the permeate flux increased by $6.0\%$ for the alumina solution and by 14.0 for the bentonite solution. With the increase in average pore size fromm $0.24\;{\mu}m\;to\;0.34\;{\mu}m$, the permeate flux increases 1.61 times for the alumina solution and 1.76 times far the bentonite solution.