• Title/Summary/Keyword: Standard solution

Search Result 1,929, Processing Time 0.027 seconds

Development of the EAI Solution Selection Criteria : Focused on the case of KRA(Korea Racing Association) (EAI(Enterprise Application Integration) 솔루션 도입을 위한 평가기준 개발 및 적용사례 연구 : KRA적용사례 중심으로)

  • Jeon Seong-Hyeon;Park Chan-Uk
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2004.10a
    • /
    • pp.158-169
    • /
    • 2004
  • Recently companies are aggressively pushing ahead with integrating the systematical applications of internal and external information systems such as Data level, Application level, Process level in the company, Process level between companies. The EAI solution is generally considered as the necessary tool to integrate companies, but the appraisal standard for the EAI solution has not yet settled in Korea, so the companies have difficulty in deciding whether to adopt the EAI solution or not. Through this report, we first introduce the KRA Project as the best practice in making an application of the settled standard to evaluate and adopt the EAI solution, and then suggest that it can be adapted to companies considering applying to the EAI solution.

  • PDF

Analysis of Magnetic Fields induced by Line Currants using Coupling of FEM and Analytical Solution (선전류에 의해 발생되는 자장의 해석을 위한 유한요소법과 해석해의 결합 기법)

  • Kim, Young-Sun;Lee, Ki-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1035-1037
    • /
    • 2005
  • The analysis of magnetic fields(2-D) induced by line currents, such as Overhead Trolley Lines or Transmission Lines, is not so easy by using the standard Finite Element Method(FEM). Mesh generation is one of the most important processes in the standard FEM. Because, the current region is relatively small compared with whole region, and actually is a line without thickness, the mesh refinement around the source lines yields many demerits. A way of supplement such a defect, we proposed the coupling scheme of analytical solution and FEM. In this study, the analytical solution is adopted around the region of line currents and FE solution is a lied to the rest of source region. And the two types of solution are coupled at the artificial boundary. To verify the usefulness of proposed algorithm, simplified model with magnetic material in FE region is chosen and analyzed. The results are compared with those of standard FEM. And the errors between them can be reduced by increasing harmonic orders.

  • PDF

Preparation Method of Indigo Standard Solution and Variation of Indigo Contents in Blue Dye Extract from Breeding Lines of Persicaria tinctoria H. Gross (인디고 분석 표준액의 제조법 및 쪽 육성계통의 인디고 함량변이)

  • Kim, Seong Ju;Ko, Jae Hyung;Park, Si Hyung;Kim, Myeong Seok;Kim, Kwan Su
    • Korean Journal of Medicinal Crop Science
    • /
    • v.21 no.3
    • /
    • pp.213-219
    • /
    • 2013
  • This study was carried out to find out the optimum method of preparation of indigo standard solution and its stability, and to investigate the indigo contents in Niram, blue dye extract, from a total of 7 indigo plants and 34 breeding lines of Persicaria tinctoria H. Gross. Proper solvent for indigo standard was dimethyl sulfoxide (DMSO), and appropriate concentration was 1 mg of indigo in 10 mL of DMSO. Absorbance value of UV/Vis Spectrophotometer at 620 nm of standard solution was changed decreasingly 12 hours after the preparation of standard solution irrespective of the storage conditions such as temperature and light. Average value of absorbance of 8-fold diluted standard solutions prepared daily during 16 days was $0.210{\pm}0.005$, indicating the powder of indigo compound was stable chemically. Calibration curve was made for quantitative analysis of indigo of 7 Niram samples, and indigo contents ranged from 0.69% to 18.76% showing relatively larger variation. Across all 34 breeding lines, the range of indigo content was from 7.9 mg to 56.4 mg per 100 g of fresh leaves, averaging 25.2 mg of indigo content and showing a 47.7% coefficient of variation.

Separation of Glutathione by Ion Exchange Chromatography (이온교환 크로마토그래픽을 이용한 Glutathione 분리)

  • 김정훈;손영종;구윤모
    • KSBB Journal
    • /
    • v.13 no.1
    • /
    • pp.77-82
    • /
    • 1998
  • Glutathione(L-$\gamma$ -glutamyl-L-cysteinylglycine, GSH) produced by microbial enzymes was separated by a liquid chromatography. In order to select a resin which would bind GSH efficiently, a batch adsorption experiment was carried out with GSH solution and various resins at pH 8.0 GSH bound to Q-sepharose and QAE-sephadex among anion exchange resins, but the latter was found not to be suitable because of the reduction of resin volume at high salt concentration. Preliminary experiments using a standard solution were carried out to separate GSH. GSH and $\gamma$ -glutamylcysteine were separated from the other constituents by applying step gradient of salt(NaCl) concentration. GSH was successfully separated from $\gamma$ -glutamylcysteine by applying Tris buffer containing 35mM NaCl. Chromatographic separation behaviors for the enzymatic product was similar to that for the standard solution. Separation yields of GSH from the standard solution and enzymatic product solution were 72.6% and 84.4%, respectively.

  • PDF

Development of the Master Data Management for the Middle manufacturing Industry (중견 제조기업에 적합한 생산 마스터 정보관리(Master Data Management) 솔루션 개발)

  • Kim, Jung-Sook
    • Journal of the Korea Society of Computer and Information
    • /
    • v.11 no.3
    • /
    • pp.97-105
    • /
    • 2006
  • Our middle manufacturing industry need a master data management solution to adjust the changing industry environment effectively. In this paper, we development the master data management solution which has an user interface to use conveniently and has a standard data architecture for the efficient connection among various systems. Also this solution composed of the automated connection module which can make an intermediate language based on the standard data architecture and composed of the extensible production data management to improve the extensibility. This solution can provide an efficient progress information of work which was not managed by officer until now as well as can provide stable system building when we want to extend the system.

  • PDF

Analysis of Magnetic Fields Induced by Line Currents using Coupling of FEM and Analytical Solution (선전류에 의해 발생되는 자장의 해석을 위한 유한요소법과 해석해의 결합 기법)

  • Kim, Young-Sun;Cho, Dae-Hoon;Lee, Ki-Sik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.55 no.3
    • /
    • pp.141-145
    • /
    • 2006
  • The line current problem(2-dimensional space : point source) is not easy to analyze the magnetic field using the standard finite element method(FEM), such as overhead trolley line or transmission line. To supplement such a defect this paper is proposed the coupling scheme of analytical solution and FEM. In analysis of the magnetic field using the standard FEM. If the current region is a relatively small compared to the whole region. Therefore the current region must be finely divided using a large number of elements. And the large number of elements increase the number of unknown variables and the use of computer memories. In this paper, an analytical solution is suggested to supplement this weak points. When source is line current and the part of interest is far from line current, the analytical solution can be coupling with FEM at the boundary. Analytical solution can be described by the multiplication of two functions. One is power function of radius, the other is a trigonometric function of angle in the cylindrical coordinate system. There are integral constants of two types which can be established by fourier series expansion. Also fourier series is represented as the factor to apply the continuity of the magnetic vector potential and magnetic field intensity with tangential component at the boundary. To verify the proposed algorithm, we chose simplified model existing magnetic material in FE region. The results are compared with standard FE solution. And it is good agreed by increasing harmonic order.

Volumetric Determination of a small amount of Iron with Potassium Ferrocyanide (훼로시안化 칼리움에 依한 鐵의 微量適定法)

  • Won, Chong-Hun
    • Journal of the Korean Chemical Society
    • /
    • v.5 no.1
    • /
    • pp.42-47
    • /
    • 1961
  • A titration of a small amount of iron with standard potassium ferrocyanide using potassium thiocyanate as indicator has been studied. A sample solution containing $0.1{\sim}1.0$ mg. $Fe^{3+}$ in 60 ml. is pipeted into 100 ml. Erlenmyer flask and the pH of the solution is adjusted to $1.5{\sim}3.0$ with 0.1 N or 1 N $HNO_3$ and $NH_4OH.$ To this solution one ml. of 1 M KCNS solution as indicator is added. The solution colored by iron thiocyanate complex is titrated with 1/200 M or 1/400 M standard solution of potassium ferrocyanide from a 5 ml. micro-buret. Near the end point, when the color of sample changes from deep red to green, about 20 ml. of ether is added and shake the flask vigorously. The red color is extracted to the ether layer. To settle the ether layer a few drops of ethanol is added and then standard solution is added dropwise and shake vigorously. The end point is reached when the color of the ether layer disappears owing to the quantitative formation of $Fe_4[Fe(CN)_6]_3.$ In this titration, 0.lmg. of $Fe^{3+}$ can be determined within 1.0% of titration error, provided the following optimum conditions, i.e., pH $1.5{\sim}3.0$, final concentration of KCNS indicator; $0.01{\sim}0.02M$, at room temperature. The titration found to be interfered by the presence of slightly soluble salts, stable complex forming ions and the ions which would be reduced by ferrocyanide or oxidized by ferric ion.

  • PDF

Determination of bromine in 1000 ㎍/g Cl standard solution by ID-ICPMS (동위원소희석 질량분석법에 의한 1000 ㎍/g 염소 표준용액 중 브롬 불순물 분석)

  • Park, Chang Joon;Suh, Jung Kee;Song, Hyun Joo;Lee, Dong Soo
    • Analytical Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.1-8
    • /
    • 2006
  • The isotope dilution method was used for the determination of Br impurity in $1000{\mu}g/g$ Cl standard solution. Since relatively pure KCl salt was used for the preparation of the Cl standard solution, the Br impurity determination suffers from both spectral and non-spectral interferences due to the presence of a large amount of K and Cl matrices. AG2-X8 anion-exchange resin was employed to separate the Br analyte from the matrices, and RF power was raised to 1500 W and nebulizer gas flow rate was lowered to 0.77 L/min to reduce background from the $ArArH^+$ molecular ions. The Br impurity in the $1000{\mu}g/g$ Cl standard solution was determined to be 43.7 ng/g with the standard addition method. The analytical result was in good agreement with 41.2 ng/g (RSD 1.6%) determined by the isotope dilution method to lower uncertainty from poor reproducibility of the anion-exchange process.

Treatment of organic dye solutions by electrodialysis

  • Majewska-Nowak, Katarzyna M.
    • Membrane and Water Treatment
    • /
    • v.4 no.3
    • /
    • pp.203-214
    • /
    • 2013
  • Laboratory tests were performed to determine the efficiency of dye solution desalination by electrodialysis. The study involved anionic dye and mineral salt recovery by obtaining two streams from a salt and dye mixture - dye-rich solution and salt solution. A standard anion-exchange and cation-exchange membranes or monovalent selective anion-exchange membranes were used in the ED stack. It was found that the separation efficiency was strongly dependent on the dye molecular weight. The best results for standard ion-exchange membranes were achieved for the desalination of Direct Black solution. Furthermore, the obtained results implied that the application of monovalent selective anion-exchange membranes improved the recovery of dye and salt solutions - the dye concentration in the diluate remained constant irrespective of the molecular weight of anionic dyes, whereas the salt recovery remained very high (99.5%).

A Non-coherent UWB Direct Chaotic Ranging System for Precision Location and Positioning

  • Yang, Wan-Cheol;Lee, Sang-Yub;Lee, Kwang-Du;Kim, Ki-Hwan;Yang, Chang-Soo;Kim, Hak-Sun
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.2
    • /
    • pp.311-315
    • /
    • 2006
  • Precision location and positioning of Asset within a network is an attractive feature with various applications, especially in indoor environments. Such a demand is met by the standard task group, IEEE 802.15.4a. Several methods, that is, pulse, chirp and chaotic communications have been proposed so far to satisfy the requirements of the standard. Among them, ultra wideband direct chaotic communications has advantageous features such as low hardware complexity, low cost, lower power consumption and flexible frequency band plan. In this paper, the feasibility of the ranging system using non-coherent chaotic transceiver is investigated by designing and implementing the system and the performance is proved by conducting location experiments in real indoor environments.

  • PDF