• Title/Summary/Keyword: Standard setting

Search Result 746, Processing Time 0.024 seconds

Effect of five PAHs (2-methylnaphthalene, fluorene, dibenzothiophene, phenanthrene, and pyrene) on the embryonic development in the mussel, Mytilus galloprovincialis (지중해담치, Mytilus galloprovincialis의 배 발생에 미치는 다환방향족탄화수소류 (2-methylnaphthalene, fluorene, dibenzothiophene, phenanthrene, pyrene) 의 영향)

  • Sung, Chan-Gyoung;Park, Pan-Soo;Lee, Jong-Hyeon;Lee, Chang-Hoon
    • The Korean Journal of Malacology
    • /
    • v.30 no.3
    • /
    • pp.177-187
    • /
    • 2014
  • Mussels have been commonly used in bioassay for quality assessments of environment. Moreover, several standard protocols for the developmental bioassay of bivalves have been proposed. In this study, the EC50 of polycyclic aromatic hydrocarbons (PAHs) was determined using mussel, Mytilus galloprovincialis embryonic developmental bioassay. To determine the sensitivity of M. galloprovincialis, their fertilized eggs were exposed to five PAHs (2-metylnaphthalene, fluorene, dibenzothiophene, phenanthrene, pyrene). The EC50 of 2-metylnaphthalene, fluorene, dibenzothiophene, phenanthrene, and pyrene were 232, 273, 67.9, 43.2, and $33.1{\mu}g/L$, respectively. The overall sensitivity of M. galloprovincialis in the present developmental bioassay was similar to or more sensitive than that of other marine organisms commonly used in aquatic bioassays. The results of this study could be provide with fundamental data of setting standard for protection of marine life and or can use prediction the aquatic toxicity of PAHs.

An Analysis on the Characteristics of Energy and Water Consumption in Urban Rental Apartment (도심(都心) 임대(賃貸)아파트의 에너지 및 상수(上水) 소비(消費) 특성(特性) 분석(分析))

  • Seo, Youn-Kyu;Kim, Joo-Young;Hong, Won-Hwa
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.11a
    • /
    • pp.261-265
    • /
    • 2008
  • To solve the lack of housing, our country has supplied an enormous volume of apartments, and these days it occupies 75% of our buildings. As apartments occupy most of our housings, the rate of energy usage from them are also high. On this, setting apartment energy reduction as a target, by researching the actual conditions of energy consumption and drawing a basis data, we can apply this as a way of saving energy, rationalization of the scale of energy supply facilities and a standard when planning facilities. To grasp the present condition of energy usage of the urban rental apartment, this research analysed the use of electricity, gas and water monthly and annually of a rental apartment that is located in Daegu. The results showed that in 2003 the electricity usage was 1,198MWh but 1,315MWh in 2007, which means 9% of electricity usage increases every year. The average of water usage was $85,072m^2$ per year and they used $604.2MJ/m^2$ Typical energy consumption unit on $74.4m^2$ of area and $448.8MJ/m^2$ on $105.8m^2$. By showing the usage of energy and water of the urban rental apartment, understanding the tendency and preparing an Typical energy consumption unit standard through this research, apartments should use energy more efficiently.

  • PDF

A Study on the Sound Proof Efficiency of Windows for Road Traffic Noise (도로변 건물의 창문과 방음효과에 대한 평가)

  • 박성배;신재영;정종흡;정일현
    • Journal of Environmental Health Sciences
    • /
    • v.21 no.4
    • /
    • pp.56-62
    • /
    • 1995
  • Recently, the traffic noise around residences and schools has become a serious social problem with the increase of the amount of transportation. This study was performed to investigate the sound proof efficiency of windows for traffic noise. The results were as follows 1) The traffic noise in 19 sites among 22 sampling sites was higher value than 65 dB(A) being roadside environment standard level in the daytime when all windows were opened, while the noise in 22 sampling sites was transmitted below standard level when all windows were closed. 2) The transmission loss of sound level at single window and double windows were 10~25 dB(A) and 11~29 dB(A) respectively. 3) The transmission loss of sound level at sampled school with sound proof pannel was 7~8 dB (A), which was lower 2~7 dB(A) than the theoretical value of the influence assessment . 4) The construction cost of double windows was lower 28% even if include the cost of setting up air conditioner for the summer season and the power consuming cost for its operation than that of sound proof pannel for traffic noise. 5) The effect of transmission loss of windows was more influenced by airtight than materials of windows.

  • PDF

Case of Application of Rail Temperature Detector for Track Management (궤도 관리를 위한 레일온도검지장치 설치 사례)

  • Chung, Sung-Hyun;Shin, Gil-Cheol;Kim, Gil-Soo
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1362-1369
    • /
    • 2007
  • Seoul Metro continuously converted the standard rail into continuous welded rail since the later part of 1990's, and currently, most of the sectors of the Seoul Metro are continuous welded rails. As the continuous welded rail is inhibited by the contraction and expansion force of the rail as well as rail-bed, this force is stored as the internal stress of the rail with the exception of portion of the both ends of the continuous welded rail. If the contraction and expansion of the rail is restricted, the internal stress, that is, the force in the direction of the axis, is proportional to the cross-sectional area of the rail. Therefore, with regards to the temperature changes, the internal stress changes in accordance with the type of rail, bolting apparatus, railroad tie and rail-bed. As such, the rail temperature becomes important data in securing the gap at the adjoining section of the rail in the standard rail section, and to determine the setting temperature for the continuous welded rail. In addition, it becomes basic data for maintenance of the track. Accordingly, this thesis introduces cases of installation of rail temperature detector in order to prevent and manage track defectiveness due to increase in rail temperature, and to utilize as basic data at the time of various construction and maintenance. Furthermore, this thesis aims to assist maintenance of track through systematic temperature management in the future by looking into means of its utilization.

  • PDF

A Review of Studies on Antibiotic Course and Antibiotic Resistance in Nasopharyngeal Pathogens in Primary Care Setting (일차진료 항생제 치료기간과 비인두 항생제 내성률에 대한 연구 고찰)

  • Shin, Hyang Hwa;Lee, Sun Haeng;Yun, Sung Joong;Chang, Gyu Tae
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.32 no.2
    • /
    • pp.64-71
    • /
    • 2018
  • Objectives The purpose of this study is to examine the correlation of antibiotics administration duration and antimicrobial resistance by reviewing domestic and foreign literatures. Methods We searched literatures dated up to 23 February, 2018 in PubMed and Cochrane Library using terms of "Anti-Bacterial Agents", "Carrier State", "Nasopharynx", "Drug Administration Schedule", and also searched via RISS (Research Information Service System), KISS (Koreanstudies Information Service System), DBpia (DataBase Periodical Information Academic) using terms of antibiotics, resistance, and dose. Results In comparison with shortened and standard antibiotic course, longer treatment duration is associated with greater antimicrobial resistance or non-significant difference, but we cannot find literature that shortened antibiotic course increases antimicrobial resistance on human nasopharyngeal flora. Conclusions Currently, there is no evidence that completing the standard antibiotic course reduces antimicrobial resistance. It can be a strategy for reducing antibiotic use to apply Korean medicine treatment, as well as short-course antibiotic therapy or delayed antibiotic prescription. Additional well-designed trials should be conducted in domestic and foreign settings about the appropriate duration of antibiotic therapy.

A parametric study of bolt-nut joints by the method of finite element contact analysis (유한 요소 접촉 해석법에 의한 나사 체결부 설계 개선에 관한 연구)

  • 이병채;김영곤
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.3
    • /
    • pp.353-361
    • /
    • 1989
  • A parametric study of load distribution in bolt-nut joints is performed by the method of finite element contact analysis. The contacting surface is assumed unbonded and frictionless. Multi-body contact analysis is performed in elastic region under the assumption of axi-symmetric stress state. Load acting on the first thread from the fastened plate is much greater than that on the other threads in the standard setting. But the load distribution is shown to be improved by making the center of contact force acting on the nut surface move outwards. Such a modification is possible by enlarging the gap between bolt shank and fastened plate or by inserting suitable washers. Shape modification of the standard nut by the making a groove and a step on the nut surface is also suggested, which results in almost uniform load distribution and considerable decrease in the maximum stress of the joint.

A Study on the Characteristics of Space Programs for Senior Center in Japan (일본 노인복지센터의 공간구성 특성에 관한 연구)

  • 소준영
    • Korean Institute of Interior Design Journal
    • /
    • no.29
    • /
    • pp.153-162
    • /
    • 2001
  • This study suggests the basic data required in setting up the standard for the architectural planning of Korean senior center by analyzing the standard and current situation of a senior center in Japan that has the welfare facility system similar to that of Korea and understanding its architectural characteristics. 1) Basic spaces that constitute the senior center in Japan are meeting room, lecture room, library, multipurpose meeting room, conference room, game-recreation room, kitchen, lounge, locker room and office. ADL, kitchen, relaxing room, private bathroom, and special bathroom are needed for adult day care as establishments as an annex and work room is also required for Job training. 2) The area of a senior center is calculated in consideration of its space organization that are required as basic. For the type "A", minimum area of 1,256.42 $m^2$2 and maximum area of 2,050.56$m^2$ and for the type "B", minimum area of 812000$m^2$ and maximum area of 1,604.14$m^2$ are suggested as optimum areas. 3) The circulation planning is presented by the connected between the space organization as well as the circulation system in day care center.

  • PDF

A Study on the Statistical Production Control of Energy Efficiency in Electric Product (전기제품 에너지 소비효율의 통계적 양산 관리 방법에 대한 연구)

  • Chun, Young-Ho;Kim, Seong-Don
    • Journal of the Korea Management Engineers Society
    • /
    • v.23 no.4
    • /
    • pp.73-86
    • /
    • 2018
  • Most electric products produced during the manufacturing process are produced after design and mass production under a given control standard. In particular, the development phase should present the criteria for the production process by setting appropriate limits based on the performance being targeted. Even if the standard of performance is set considering the performance of the process, measuring the performance of the product after actual production results will cause nonconformities with the expected results. Among the performance of electrical products, Energy standards represented by energy consumption efficiency continue to be of importance, and are mandatory standards that correspond to national standards in most countries. Therefore, statistical quality control of these standards shall basically have a large number of test equipment for each product, ensure sufficient test time and continuous sampling of product samples. In the end, companies that produce and sell electric appliances are striving to control mass production at a great cost, but this is not acceptable. This study presents basic characteristics of the energy efficiency of electrical products and proposes and conducts a case study on statistical production control methods for performance variation across products under the standards about domestic and international regulations.

A Study on the Possibility of Expanding the Use of Green Remodeling for Fire Stations (소방서를 대상으로 한 그린리모델링 용도 확대 가능성 분석에 관한 연구)

  • Sangheon Jeong;Jinhwan Oh;Sangmu Bae;Yujin Nam
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.20 no.1
    • /
    • pp.8-15
    • /
    • 2024
  • This study aims to investigate the possibility of expanding the support program for green remodeling of fire stations and analyze the standard design guidelines. Green remodeling is essential for reducing greenhouse gas emissions and promoting green buildings, but currently, it is only conducted for buildings with limited purposes. In this study, we conduct green remodeling for fire stations with severe aging to demonstrate energy performance improvement and investigate the potential for expanding the support program to other types of aging buildings. The research methodology includes analysis of previous studies, preliminary investigation and alternative setting, energy analysis, calculation of construction costs, evaluation of the possibility of introducing support programs, and examine of the fire station standard design guidelines. The research results confirm that green remodeling can reduce energy consumption in fire stations and present the possibility of including fire stations as targets in the support program for green remodeling of public buildings.

A Study on Function of the Delineation System by Pattern for Safety Audit on Road Exit Ramp (국도유출부 안전진단을 위한 시선유도시설의 유형별 기능검토)

  • Kum, Ki-Jung;Kim, Hong-Sang;Min, Kyeong-Tae;Yang, Gye-Seung
    • International Journal of Highway Engineering
    • /
    • v.8 no.4 s.30
    • /
    • pp.1-11
    • /
    • 2006
  • Currently, road mobility improved from the National Road Improvement. Nevertheless delineation system is facility that enhanced driver's safety, that was set up often inconsistent or nonexistent over the road exit ramp So it judged functional investigation will be necessary. This study suggested setting type of the delineation system. That was based on a field study and reviews the legal standard of it and considering driver's cognition behavior. For the study, make a 3D-simulation and so could objectively a comparative test. Comparison variable between delineation setting type is selected conspicuity and visibility. Cased that illustrated characteristics of driver's visual cognition behavior. The experiment was used Eye Marker Recorder for measure the gaze frequency more quantitatively and objectively. And used the ANOVA analysis for significance testing between delineation setting type. A significant percent of the conspicuity analyzed types(Safe mark, Obstacle Sign, Warning Light, and Tubular Maker) in road exit ramp for recognize. And gaze frequency that measure of effectiveness of visibility are measured. On the analysis result, the visibility was significance difference between delineation setting type and visibility of types was best.

  • PDF