• Title/Summary/Keyword: Standard pattern

Search Result 1,490, Processing Time 0.024 seconds

Characteristics of Fire-induced Thermal-Flowfields in an Underground Utility Tunnel with Ventilation (화재 발생시 환기방식에 따른 지하공동구내 열유동 특성 연구)

  • Kim, Hong-Sik;Hwang, In-Ju;Kim, Yun-Je
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1845-1850
    • /
    • 2003
  • The underground utility tunnels are important facility as a mainstay of country because of communication developments. The communication and electrical duct banks as well as various utility lines for urban life are installed in the underground utility tunnel systems. If a fire breaks out in this life-line tunnel, the function of the city will be discontinued and the huge damages are occurred. In order to improve the safety of life-line tunnel systems and the fire detection, the behaviors of the fire-induced smoke flow and temperature distribution are investigated. In this study we assumed that the fire is occurred at the contact or connection points of cable. Numerical calculations are carried out using different velocity of ventilation in utility tunnel. The fire source is modeled as a volumetric heat source. Three-dimensional flow and thermal characteristics in the underground tunnel are solved by means of FVM (Finite Volume Method) using SIMPLE algorithm and standard ${\kappa}-{\varepsilon}$ model for Reynolds stress terms. The numerical results of the fire-induced flow characteristics in an underground utility tunnel with different velocity of ventilation are graphically prepared and discussed.

  • PDF

Preliminary Study to Develop the Instrument of Oriental Medical Evaluation for Hwa-Byung (화병 한의 평가도구 개발을 위한 기초 연구)

  • Cheong, Myung-Hee;Lee, Sang-Ryong;Kang, Wee-Chang;Jung, In-Chul
    • Journal of Oriental Neuropsychiatry
    • /
    • v.21 no.2
    • /
    • pp.141-155
    • /
    • 2010
  • Objectives : This study was performed to develop a standard instrument of oriental medical evaluation for hwa-byung. Methods : The advisor committee on this study was organized by 17 neuropsychiatry professors of oriental medical colleges. The items and structure of the instrument were quoted from the instrument of pattern identification for hwa-byung. We took consultation twice from the advisor committee and we also took additional advices by e-mail. Results : We discriminated between bian-zheng and su-zheng from the answers of the advisor committee. We got the mean weight of each symptom and sign from the answers of the advisor committee. We got the final weight from the combination of the ratio of bian-zheng to the number of all answers of the advisor committee and mean weight. Conclusions : The instrument of oriental medical evaluation for hwa-byung was developed through experts' discussion. If the validity and reliability of this instrument is confirmed through additional clinical trial, the instrument of oriental medical evaluation for hwa-byung is expected to be applied to the subsequent research.

Flow Analysis of the Plain Seal with Injection (분사를 수반하는 평씨일 내의 유동해석)

  • 이관수;김우승;김기연;김창호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.4
    • /
    • pp.795-802
    • /
    • 1992
  • A numerical analysis is performed on the turbulent flow in the plain seal with injection. The parameters used in this study are as follows : Reynolds number, rotation speed, injection speed, clearance ratio, injection angle, and axial injection location. Flow pattern and leakage performance due to the variation of parameters are investigated. SIMPLER algorithm is used to solve the Navier-Stokes equation governing steady, incompressible turbulent flow and standard K- .epsilon. turbulent model is used to consider the turbulence effects. The leakage performance is significantly enhanced with injection. The increases of the injection flow rate and be rotation speed of the shaft cause the leakage performance to the increased. With the increase of the Reynolds number the leakage performance is diminished. At the injection angle of 90deg, the leakage coefficient has a minimum value. The pressure drop has a maximum value at axial center location but the injection location has little effect on the pressure drop. Clearance ratio has a significant effect on the pressure drop.

Improving the Training Performance of Multilayer Neural Network by Using Stochastic Approximation and Backpropagation Algorithm (확률적 근사법과 후형질과 알고리즘을 이용한 다층 신경망의 학습성능 개선)

  • 조용현;최흥문
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.31B no.4
    • /
    • pp.145-154
    • /
    • 1994
  • This paper proposes an efficient method for improving the training performance of the neural network by using a hybrid of a stochastic approximation and a backpropagation algorithm. The proposed method improves the performance of the training by appliying a global optimization method which is a hybrid of a stochastic approximation and a backpropagation algorithm. The approximate initial point for a stochastic approximation and a backpropagation algorihtm. The approximate initial point for fast global optimization is estimated first by applying the stochastic approximation, and then the backpropagation algorithm, which is the fast gradient descent method, is applied for a high speed global optimization. And further speed-up of training is made possible by adjusting the training parameters of each of the output and the hidden layer adaptively to the standard deviation of the neuron output of each layer. The proposed method has been applied to the parity checking and the pattern classification, and the simulation results show that the performance of the proposed method is superior to that of the backpropagation, the Baba's MROM, and the Sun's method with randomized initial point settings. The results of adaptive adjusting of the training parameters show that the proposed method further improves the convergence speed about 20% in training.

  • PDF

An Overview on Standards for Seasonal Performance Evaluation of Multi-type Air Conditioners (멀티형 에어컨의 기간에너지소비효율 평가규격에 관한 연구)

  • 박윤철;문제명;홍주태
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.1
    • /
    • pp.91-100
    • /
    • 2004
  • Energy efficiency evaluation method for a multi-type air conditioning system still has not been developed. In this study, analysis on capacity range and evaluating method of standards for air conditioners was conducted with world-wide Standards. It is not a proper approach to use the standards for residential air conditioner to multi type air conditioners. Some difficulties and problems are commented in this study with overview of the standards. Through the analytic research, an evaluating method for multi type air conditioner was suggested with Integrated Part Load Value (IPLV). The suggested concept for evaluating energy efficiency during part load condition considers building load pattern and operating hours of the system at different locations. Load was weighted in IPLV to consider not only the concept of occurrence of outdoor temperature such as bin method but also operation hours of the system. An experiment about the IPLV was conducted with variable air volume ducted type air conditioning system and multi-type system through modified code tester to give a glance at quantitative value of the IPLV.

A Study on the Handle and Texture of Artificial Suede (인조 스웨이드의 handle 및 질감에 관한 연구)

  • 신경인;김종준
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.24 no.1
    • /
    • pp.128-137
    • /
    • 2000
  • A range of suede-like samples were collected including woven fabric type, nonwoven fabric type, and natural suede(sheep). The surface textures of these suede-like fabrics are rather diverse and different from the plain filament type fabrics since there are a lot of fine surface free fiber ends. Physical and mechanical measurements were carried using the KES equipments. Based on the Kawabata-Niwa translational equation, primary hand values and THV were calculated. Uniaxial tensile tests were performed. Using glossmeter, the reflectance pattern was analyzed at different incidence and receiving angles. In order to capture the surface images of the specimens, a CCD camera and frame grabber connected to a PC were employed. The reflectance uniformity of the images was measured with line-profile analysis and standard deviation values of the profile of the images were calculated. After the multiscale wavelet transfermation, correlation among the transformed image was analyzed at each scale. The reflectance uniformity of the natural suede was better than that of nonwoven type suede, while that of woven type suede was the last among the selected three samples(natural suede, nonwoven type, woven type). The correlation analysis among images has shown the possibility of using the wavelet transformation of the images as one of the measures to detect similarities among the textured specimens.

  • PDF

Bacteriology and Antibiotic Sensitivity for Diabetic Foot Ulcer (당뇨족 궤양의 세균 역학과 항생제 감수성)

  • Choi, Sang-Rok;Lee, Chang-Kyu;Kim, Deok-Woo;Han, Seung-Kyu;Kim, Woo-Kyung
    • Archives of Plastic Surgery
    • /
    • v.33 no.3
    • /
    • pp.330-334
    • /
    • 2006
  • Polymicrobial nature of diabetic foot infection has been well documented in the literature. Initial antibiotic therapy of diabetic foot infection is usually empiric until reliable culture data is shown. This study was carried out to determine the common bacteriological flora of diabetic foot infection and antimicrobial sensitivity pattern in order to enhance possible empiric treatment. The specimens were obtained from wounds of 207 cases of diabetic foot ulcer, and the bacteriological isolation, and antimicrobial susceptibility tests of the isolates were carried out by standard microbiological methods. Staphylococcus aureus was the most common isolate, with 46.2% of recover rate among total bacterial isolated cases. Among gram-negative organisms, Pseudomonas aeruginosa was most common. Gram-positive organisms showed significant susceptibility to clindamycin, trimethoprim/sulfamethoxazole, and levofloxacin, besides vancomycin. Cefoperazone, piperacillin/tazobactam, and amikacin in addition to imipenem were most effective agents compared to gram-negative organisms. Diabetic foot infection requires use of combined antimicrobial therapy for initial management. Our results indicate that the most effective antibiotic combination for diabetic foot infection of Korean patients is clindamycin plus cefoperazone.

Measurement and Correction of PCB Alignment Error for Screen Printer Using Machine Vision (1) (머신비전을 이용한 PCB 스크린인쇄기의 정렬오차측정 및 위치보정 (1))

  • 신동원
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.6
    • /
    • pp.88-95
    • /
    • 2003
  • This paper presents the measurement and correction method of PCB alignment errors for PCB screen printer. Electronic equipment is getting smaller and yet must satisfy high performance standard. Therefore, there is a great demand for PCB with high density. However conventional PCB screen printer doesn't have enough accuracy to accommodate the demand fur high-resolution circuit pattern and high-density mounting capacity of electronic chips. It is because the alignment errors of PCB occur when it is loaded to the screen printer. Therefore, this study focuses on the development of the system which is able to measure and correct alignment errors with high-accuracy. An automatic optical inspection part measures the PCB alignment errors using machine vision, and the high-accuracy 3-axis stage makes correction for these errors. This system used two CCD cameras to get images of two fiducial marks of PCB. The geometrical relationship between PCB, cameras, and xy$\theta$ stage is derived, and analytical equations for alignment errors are also obtained. The unknown parameters including camera declining angles and etc. can be obtained by initialization process. Finally, the proposed algorithm is verified by experiments by using test bench.

Measurement and Correction of PCB Alignment Error for Screen Printer Using Machine Vision (2) (머신비전을 이용한 PCB 스크린인쇄기의 정렬오차측정 및 위치보정 (2))

  • 신동원
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.6
    • /
    • pp.96-104
    • /
    • 2003
  • This paper presents the measurement and correction method of PCB alignment errors for PCB screen printer. Electronic equipment is getting smaller and yet must satisfy high performance standard. Therefore, there is a great demand for PCB with high density. However conventional PCB screen printer doesn't have enough accuracy to accommodate the demand for high-resolution circuit pattern and high-density mounting capacity of electronic chips. It is because the alignment errors of PCB occur when it is loaded to the screen printer. Therefore, this study focuses on the development of the system which is able to measure and correct alignment errors with high-accuracy. An automatic optical inspection part measures the PCB alignment errors using machine vision, and the high-accuracy 3-axis stage makes correction for these errors. This system used two CCD cameras to get images of two fiducial marks of PCB. The centers of fiducial marks are obtained by using moment, gradient method. The first method is calculating the centroid by using first moment of blob, and the latter method is calculating the center of the circle whose equation is obtained by curve-fitting the boundaries of fiducial mark. The operating system used to implement the whole set-up is carried in Window 98 (or NT) environment. Finally we implemented this system to PCB screen printer.

A Study on the Patient Privacy Protection of Medical Information For Internet (인터넷 환경에서의 의료정보화와 환자개인정보보호 방안)

  • Ji, Hye-Jung;Shin, Seung-Jung;Kim, Jung-Ihl
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.8 no.5
    • /
    • pp.235-241
    • /
    • 2008
  • Please Interests in the medical service are increasing in internet environment as life quality of the people improves because of development in information and medical technology. The medical information in today's modern internet environment can violate privacy of the patients. Many medical institutions in Korea are very passive in the privacy protection of patients in the internet environment. The law, standard scheme and systematic guidance to prevent drain of medical information are not developed. This study examines cases of infringement pattern on information of each patient in the internet environment. This study will also try to find a solution to protect the personal information of patients in the internet environment in the measures of law system, technique and management.

  • PDF