• Title/Summary/Keyword: Standard of test methods

Search Result 2,193, Processing Time 0.031 seconds

Performance evaluation facilities and evaluation methods for hydropower equipment (해외 수력발전설비 성능평가설비 및 평가 방법)

  • Kim, Youngjoon;Kim, Yongyeol;Cho, Yong;Ko, Jaemyoung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.194-194
    • /
    • 2010
  • The variable demand on the energy market, as well as the limited energy storage capabilities, requires a great flexibility in operating hydraulic turbines. But, present in Korea, the absence of testing laboratories and technical criteria for the performance test of small hydropower degrades the efficiency of the domestic hydropower machines, A performance guarantees for hydro turbines shall be contain, as a minimum, guarantees covering power, discharge and specific hydraulic energy, efficiency, maximum momentary overspeed and maximum momentary pressure and/or maximum steady-state runaway speed, as well as guarantees related to cavitation. Performance test are conducted by the test standard. Test codes based on extensive research data are written under the leadership of an IEC. Performance evaluation is carry out several test(performance test, cavitation test and runaway test). The paper presents the international turbine test laboratory and performance test standard.

  • PDF

A Study on the Method of Optimizing the Test Order of Explosive Detection System Using Analytic Hierarchy Process and Objective Rating (계층분석방법 및 객관적평가법을 활용한 폭발물탐지장비 시험순서 최적화 방법에 관한 연구)

  • Sun-Ju, Won;Hyun Su, Sim;Yong Soo, Kim
    • Journal of Korean Society for Quality Management
    • /
    • v.50 no.4
    • /
    • pp.793-810
    • /
    • 2022
  • Purpose: As improving the search performance of aviation security equipment is considered essential, this study proposes the need for research on how to find an optimized test sequence that can reduce test time and operator power during the search function test of explosive detection systems. We derive the weights and work difficulty adjustment factor required to find the optimized test order. Methods: First, after setting the test factors, the time of each test and the difficulty scale determined by the worker who performed the test directly were used to derive weights. Second, the work difficulty adjustment coefficient was determined by combining the basic weight adjustment factor and corresponding to the body part used by the test using objective rating. Then the final standard time was derived by calculating the additional weights for the changeability of the test factors. Results: The order in which the final standard time is minimized when 50 tests are performed was defined as the optimized order. 50 tests should be conducted without duplication and the optimal order of tests was obtained when compared to previously numbered tests. As a result of minimizing the total standard time by using Excel's solver parameters, it was reduced by 379.14 seconds, about 6.32 minutes. Conclusion: We tried to express it in mathematical formulas to propose a method for setting an optimized test sequence even when testing is performed on other aviation security equipment. As a result, the optimal test order was derived from the operator's point of view, and it was demonstrated by minimizing the total standard time.

Comparative Study on Test Methods for Mechanical Properties of Structural Adhesives Used in FRP Strengthening (구조보강용 FRP 함침·접착수지의 역학적 특성 분석을 위한 시험방법 비교 연구)

  • You, Young Chan;Choi, Ki Sun;Kim, Keung Hwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.2
    • /
    • pp.103-112
    • /
    • 2008
  • Pull-off test is generally used to evaluate bond strength of FRP composite with concrete at job site. However, some damages on FRP composites can not be avoided during pull-off test and moreover test range of pull-off strength is limited by maximum tensile strength of concrete. Accordingly, it is required to set-up a test method that can evaluate mechanical properties of structural adhesive indirectly prior to pull-off test. In this study, the standard test methods for structural adhesive which can simply evaluate mechanical performance of adhesive were suggested through comparative experiments from each different standard in various countries. Particularly, gluing thickness of adhesive in tensile lap-shear tests, the section dimension of compression and bending test specimens become unified, and standard test specimen size is achieved by test results.

Study on the unification between KS I ISO standard and official test method enacted by Korean Ministry of Environment - drinking water and indoor air quality - (환경오염공정시험기준과 KS ISO규격의 일원화에 관한 연구 - 먹는 물 및 실내공기질 -)

  • Lee, Jeong-Il;Lee, Ju-Hee;Lee, Jeong-Hee;Lee, Jun-Hee;Lee, Won-Seok;Kim, Ji-In;Kim, Bo-Kyung;Choi, Sung-Hun
    • Analytical Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.102-113
    • /
    • 2012
  • Our study researched on unification of KS I ISO standard harmonized with ISO and Official Test Method enacted by Korean Ministry of Environment-drinking water and indoor air quality. We reviewed KS methods related to drinking water and indoor air quality for about 23,000 KS methods. KS methods related environmental field are classified as KS I, total 635 methods and 583 KS I methods were harmonized with ISO. For Environmental Standard methods for drinking water, 100 methods were reviewed according to 232 KS methods related to ISO/ TC 147 "Water Quality". Environmental Standard methods for indoor air quality were reviewed according to 95 KS standard methods related to ISO/TC 146 "Air Quality". By reviews and comparison tests for unifiable ES for drinking water and indoor air quality with KS methods harmonized with ISO, it was evaluated that for 100 ES methods for drinking water, 23 ES methods were unification complete, 29 ES methods were unification possible, 12 ES methods were unification impossible, no corresponding methods were found in KS I ISO for 36 ES methods and for 17 ES methods for indoor air quality,1 ES methods were unification complete, 3 ES methods were unification possible, 3 ES methods were impossible, no corresponding methods were found in KS I ISO for 10 ES methods.

Comparison Study on Nondestructive Strength Equation Based on Probability for Bridges (확률론적 방법을 적용한 도로교량의 비파괴 압축강도식 평가)

  • Kim, Hun-Kyom
    • International Journal of Highway Engineering
    • /
    • v.20 no.3
    • /
    • pp.39-46
    • /
    • 2018
  • PURPOSES: This study is to estimate nondestructive strength equation based on probability for bridges using field test data. METHODS : In this study, a series of the field inspection and the test have been performed on 297 existing bridges, in order to evaluate the bridges, based on the test results of the in-depth inspection, and the estimated strengths by means of the nondestructive strength equations are analyzed and compared with results of the core specimen strengths. RESULTS : According to results of analyses, In case of standard design compressive strength of concrete is 18MPa, 21MPa, similar reliability of RILEM equation were 0.89~0.90, but in case of standard design compressive strength of concrete is 35MPa, 40MPa were 0.4~0.56. According to standard design compressive strength of concrete is 40MPa, similar reliability of ultrasonic pulse velocity method equation were 0.56. CONCLUSIONS :RILEM equation had high similar reliability than other equation in case of standard design compressive strength of concrete is 18MPa, 21MPa, but had low similar reliability than other equation in case of standard design compressive strength of concrete is 35MPa, 40MPa. and ultrasonic pulse velocity method equation had low similar reliability than other equation in case of standard design compressive strength of concrete is 40MPa.

A Comparative Analysis of Test Methods of Measuring d- and q-Axes Inductances for Interior Permanent Magnet Synchronous Motor (매입형 영구자석 동기전동기의 인덕턴스 측정법 비교 분석)

  • Kim, Seung-Joo;Kim, Cherl-Jin;Lee, Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.5
    • /
    • pp.923-928
    • /
    • 2009
  • The performance analysis and robust control of the interior permanent magnet synchronous motor(IPMSM) greatly depend on accurate value of its parameters. To achieve the high performance of torque control, it is necessary to consider exact inductance values because the inductances are nonlinear parameters of operating the IPMSM. Therefore many different methods have been performed for analysis of the methodology for the exact measurement of synchronous inductances. None of them is considered standard, and accuracy levels of all these methods are also not consistent. Among these experimental methods, the DC current decay test and the vector current control test are ideal for a laboratory environment. In this paper, these two test methods are compared by applying inductances to the IPMSM. The paper analyzes the measured inductances of the two methods and their differences with inductances obtained from the finite element method(FEM).

A Study on the Quality Improvement of College Scholastic Ability Test Scoring System (대학수학능력시험 점수산정시스템의 품질 제고를 위한 연구)

  • Park, Youngsun
    • Journal of Korean Society for Quality Management
    • /
    • v.50 no.2
    • /
    • pp.199-220
    • /
    • 2022
  • Purpose: The purpose of this study is to analyze the score data released by the Korea Institute of Curriculum and Evaluation to find out the problems with the current scoring system provided by the College Scholastic Ability Test and to suggest improvement measures to solve these problems. Methods: We calculated the descriptive statistics of the standard scores using the frequency distribution table of the standard scores and identified the characteristics of the standard scores by expressing the distribution as a graph. Also, we developed an index to evaluate whether each stanine level was stably assigned and calculated the indexes for each area/subject by using the data on the number of examinees for each level. Results: We found that the relationship of conversion from raw scores to integerized standard scores is different depending on the size of the standard deviation of the raw scores, and identified the problem that the raw score information is not fairly reflected in the calculation of the percentile and level as the two raw scores are converted to one standard score. This problem can be solved by calculating the standard score to a decimal point. Conclusion: In this study, as a way to improve the quality of the scores of the current CSAT, the standard score and percentile decimal notation, the specific regulations of the standard score and stanine level calculation method, and the expansion of the open range of the scores were suggested.

Estimation of Liquid Limit by a Single-point Method of Fall Cone Test (Fall Cone Test의 일점법을 이용한 액성한계 추정)

  • Son, Young-Hwan;Chang, Pyoung-Wuck;Won, Jung-Yun;Kim, Seong-Pil
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.203-206
    • /
    • 2003
  • The liquid limit(LL) test is universally used as a standard test for determining one of the index properties of a clay. There are two methods of determining the LL, Casagrande method and cone penetration method that is fall cone test. The interpretation of the Casagrande method of obtaining the LL is not obvious, but it has been suggested that the fall cone test is essentially a strength test and that the LL test simply ascertains the moisture content at which a clay has a certain standard undrained shear strength. This paper presents a determination of the LL by a single-point method. Results obtained from fall cone that is general method and a single-point method are analyzed by comparison.

  • PDF

Comparison and Analysis between the simulation and test result for Quality Assessment of Surge Protective Insulating Transformer. (서지방호용 절연변압기 성능시험관련 모의해석 및 시험결과와의 비교분석)

  • Choi Young-Ha;Kim Myung-Young;Lee Kang-Won;Ohn Jung-Ghun;Song Joong-Ho
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.519-522
    • /
    • 2003
  • 'KRS 6330-3256라' standard regulates performance test of insulating transformer for protecting the electronic interlock linkage equipment which is being done by test procedures and methods according to the standard. The balance/unbalance test evaluating the performance of transformer are applied by impulse voltage($l2/200{\mu}s$) but affected by many other factors. Therefore, the review about these is necessary to have the reliability and reappearance of test results. In this paper, we have simulated about several phenomenon appearing in real balance/unbalance test and compared simulated results with real ones. With the basis of these results, the influence to test result of inner and outer factors are investigated and analyzed and established the plan boosting the reliability and reappearance of test results.

  • PDF

Evaluation Methods for Flat Crush Resistance of Corrugated Fiberboard with Microflutes

  • Youn, Hye-Jung;Kwon, Hyun-Seung;Lee, Hak-Lae
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.41 no.5
    • /
    • pp.8-14
    • /
    • 2009
  • Corrugated fiberboard is a widely used packaging material because of its high compressive strength and stiffness despite light weight. Corrugated fiberboards with microflutes with height $\leq$ 1.5 mm, such as E, F or G, have been developed. As microflutes have a different geometry from other conventional flutes, they may behave differently in testing and require a new testing method. Therefore, we evaluated the flat crush resistance of corrugated fiberboard with microflutes according to the ISO and TAPPI standard test methods. In addition, the effects of specimen area and platen compression rate were examined. The goal of this study was to identify an appropriate method for flat crush test (FCT) of corrugated fiberboard with microflutes. When a test piece with a standard area was subjected to the FCT in accordance with ISO and TAPPI methods, microflute corrugated fiberboard demonstrated a different load-displacement curve. An area of 20 $cm^2$ was determined to be the most appropriate for FCTof microflute corrugated fiberboard.