• 제목/요약/키워드: Standard measure

검색결과 1,920건 처리시간 0.029초

Study on Calibration Methods of Discharge Coefficient of Sonic Nozzles using Constant Volume Flow Meter

  • 정완섭;신진현;강상백;박경암;임종연
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2010년도 제39회 하계학술대회 초록집
    • /
    • pp.17-17
    • /
    • 2010
  • This paper address technical issues in calibrating discharge coefficients of sonic nozzles used to measure the volume flow rate of low vacuum dry pumps. The first challenging issue comes from the technical limit that their calibration results available from the flow measurement standard laboratories do not fully cover the low vacuum measurement range although the use of sonic nozzles for precision measurement of gas flow has been well established in NMIs. The second is to make an ultra low flow sonic nozzlesufficient to measure the throughput range of 0.01 mbar-l/s. Those small-sized sonic nozzles do not only achieve the noble stability and repeatability of gas flow but also minimize effects of the fluctuation of down stream pressures for the measurement of the volume flow rate of vacuum pumps. These distinctive properties of sonic nozzles are exploited to measure the pumping speed of low vacuum dry pumps widely used in the vacuum-related academic and industrial sectors. Sonic nozzles have been standard devices for measurement of steady state gas flow, as recommended in ISO 9300. This paper introduces two small-sized sonic nozzles of diameter 0.03 mm and 0.2 mm precisely machined according to ISO 9300. The constant volume flow meter (CVFM) readily set up in the Vacuum center of KRISS was used to calibrate the discharge coefficients of the machined nozzles. The calibration results were shown to determine them within the 3% measurement uncertainty. Calibrated sonic nozzles were found to be applicable for precision measurement of steady state gas flow in the vacuum process. Both calibrated sonic nozzles are demonstrated to provide the precision measurement of the volume flow rate of the dry vacuum pump within one percent difference in reference to CVFM. Calibrated sonic nozzles are applied to a new 'in-situ and in-field' equipment designed to measure the volume flow rate of low vacuum dry pumps in the semiconductor and flat display processes.

  • PDF

배관 압력을 이용한 방향제어밸브 위상각 대역폭 주파수 측정에 관한 연구 (A Study on the Phase Bandwidth Frequency of a Directional Control Valve Based on the Hydraulic Line Pressure)

  • 김성동;이정은;신대영
    • 드라이브 ㆍ 컨트롤
    • /
    • 제15권4호
    • /
    • pp.1-10
    • /
    • 2018
  • Spool displacement of a direction control valve is the standard signal to measure the bandwidth frequency of the direction control valve. When the spool displacement signal is not available, it is suggested in this study to use the metering hydraulic line as an alternative way to measure - 90 degree phase bandwidth frequency of the hydraulic direction control valve. Dynamics of the hydraulic line is composed of inertia, capacitance, and friction effects. The effect of oil inertia is dominant in common hydraulic line dynamics and the line dynamics is close to a derivative action in a range of high frequency; such as a range of bandwidth frequency of common directional control valves. Phase difference between spool displacement and line load pressure is nearly constant as a valve close to 90 degree. If phase difference is compensated from the phase between valve input and pressure, compensated phase may be almost same as the phase of spool displacement that is a standard signal to measure phase bandwidth frequency of the directional control valve. A series of experiments were conducted to examine the possibility of using line pressure in to measure phase bandwidth frequency of a directional control valve. Phase bandwidth frequency could be measured with relatively high precision based on metering hydraulic line technique and it reveals consistent results even when valve input, oil temperature, and supply pressure change.

표준모타를 이용한 추진제 연소특성 분석 (Combustion Property Analysis of Propellant using Standard Motor)

  • 박의용;최성한;황종선
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2003년도 제21회 추계학술대회 논문집
    • /
    • pp.181-184
    • /
    • 2003
  • 메인모타 추진제의 연소속도를 예측하기 위하여 표준모타를 제작하고 지상연소시험을 수행하였다. 이를 위하여 중, 소형 모타의 시험에 적합한 지상연소시험장을 구축하고 경량화된 6 inch 급의 표준모타를 개발하여 여러 차례의 시험에 적용하였고, 메인모타의 연소속도와 비교하였다. 그 결과 표준모타를 이용하는 방법이 기존의 연소속도 측정 방법에 비해 메인모타의 연소속도를 비교적 잘 반영하는 것으로 나타나, 앞으로의 추진제 개발 활동 및 양산품의 품질보증 활동에 적극 활용할 계획이다.

  • PDF

ILAS와 ILAS-II 자료에서 나타난 남극 와동 붕괴기간의 미량기체 분포변화 (Variation of Tracer Distribution During the Antarctic Polar Vortex Breakup Shown in ILAS and ILAS-II Data)

  • 최우갑;임경수
    • 대기
    • /
    • 제20권3호
    • /
    • pp.367-377
    • /
    • 2010
  • Variation of tracer distribution during the vortex-breakup period in the Antarctic region was observed by the data from the Improved Limb Atmospheric Spectrometer (ILAS) and ILAS-II. All four trace species including methane, nitrous oxide, ozone, and water vapor show similar patterns of vertical gradient in spite of different structures of zonal mean mixing ratio. Timings of vortex breakup on each level are estimated by two different methods, and they are compared with zonal standard deviations following the latitude circle of each trace species. Although the tracers have different chemical life times and sink/source, the zonal standard deviation patterns show remarkable similarities. The zonal standard deviation shown here to measure the zonal asymmetry of tracer distribution is believed to diagnose the timing of the Antarctic polar-vortex breakup reasonably well.

ICP/AES에 의한 먹는물의 무기원소 분석 (Elemental Analysis of Drinking Water with ICP/AES)

  • 박계헌;신형선;한정희
    • 자원환경지질
    • /
    • 제29권1호
    • /
    • pp.21-24
    • /
    • 1996
  • Inductively coupled plasma atomic emission spectrophotometer (ICP/AES) is a versatile modern instruments for the multi-element analysis, but quantitative analysis using ICP/AES with normal pneumatic nebulizer is not applicable for the measurement of elemental concentrations in water down to the drinkining water standard level except a few elements because of poor detection limits. However, the detection limit can be lowered enough to measure drinking water standard, if ultrasonic nebulizer and/or hydride vapor generator is attached. This method is tested with groundwater samples from Tajeon area. It is confirmed that the elemental concentrations in these samples are within the limit of drinking water standard for the most elements. However, uranium concentration is very high in some samples compared with the concentrations suggested by Environmental Protection Agency of U.S.A. There is no standard concentration level to this element in Korea and it should be prepared immediately.

  • PDF

표준 Limits 및 Fits가 조립 로보트의 생산성에 미치는 영향 (The Effect Of Standard Limits And Fits On The Productivity Of Assembly Robots)

  • 김선호
    • 대한산업공학회지
    • /
    • 제17권2호
    • /
    • pp.75-86
    • /
    • 1991
  • This paper presents a methodology to enable the tolerances on mating parts of an assembly to be specified and be compatible to the precision of an assembly robot so as to achieve maximum system performance. The measure of performance is defined as the Probability of Successful Assembly (PSA). A typical loose fastener assembly, usually called peg-in-a-hole is investigated. The Geometric Tolerancing System is adopted to represent position tolerances of mating parts. Two models are presented by considering modifiers on a position tolerance, Regardless of Feature Size (RFS) and Maximum Material Condition (MMC). Using these models, it is analyzed how the Standard Limits and Fits recommended by ANSI influence the performance of an assembly robot. For this analysis, the Standard Limits and Fits are transformed to the representation scheme of the Geometric Tolerancing System. Due to low PSAs when the Standard Limits and Fits are taken into account, the effect of chamfers around a hole is also analyzed.

  • PDF

A Study for Robustness of Objective Function and Constraints in Robust Design Optimization

  • Lee Tae-Won
    • Journal of Mechanical Science and Technology
    • /
    • 제20권10호
    • /
    • pp.1662-1669
    • /
    • 2006
  • Since randomness and uncertainties of design parameters are inherent, the robust design has gained an ever increasing importance in mechanical engineering. The robustness is assessed by the measure of performance variability around mean value, which is called as standard deviation. Hence, constraints in robust optimization problem can be approached as probability constraints in reliability based optimization. Then, the FOSM (first order second moment) method or the AFOSM (advanced first order second moment) method can be used to calculate the mean values and the standard deviations of functions describing constraints and object. Among two methods, AFOSM method has some advantage over FOSM method in evaluation of probability. Nevertheless, it is difficult to obtain the mean value and the standard deviation of objective function using AFOSM method, because it requires that the mean value of function is always positive. This paper presented a special technique to overcome this weakness of AFOSM method. The mean value and the standard deviation of objective function by the proposed method are reliable as shown in examples compared with results by FOSM method.

공항 수.배전 설비 표준화 (Standardization for receive and supply of electric power facility of airport)

  • 최홍규;원진희;송영주;조계술
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2003년도 학술대회논문집
    • /
    • pp.349-354
    • /
    • 2003
  • Airport facility is infrastructure that become external creditworthiness and linear measure of country competitive power. Among them, receive and supply of electric power facility of airport is very important in peculiarity, trustability, safety side of airport. In this parer, sorted domestic airline as 4 classes by code to accomplish standardization for receive and supply of electric power facility of airport. And established justice and coverage about receive and supply of electric power facility using without any standard present and analyze problem for receive and supply of electric power facility of existing airport and presents standard. Finally, present standard single-line diagram by airport grade and system grade standard of receive and supply of electric power facility of airport.

  • PDF

화물 선적 최적화를 위한 LiDar 센서 기반 비규격 화물 체적산출 방법 연구 (A Study on the Method of Non-Standard Cargo Volume Calculation Based on LiDar Sensor for Cargo Loading Optimization)

  • 전영준;김예슬;안선규;정석찬
    • 한국멀티미디어학회논문지
    • /
    • 제25권4호
    • /
    • pp.559-567
    • /
    • 2022
  • The optimal shipping location is determined by measuring the volume and weights of cargo shipped to non-standard cargo carriers. Currently, workers manually measure cargo volume, but automate it to improve work inefficiency. In this paper, we proposed the method of a real-time volume calculation using LiDar sensor for automating cargo measurement of non-standard cargo. For this purpose, we utilized the statistical techniques for data preprocessing and volume calculation, also used Voxel Grid filter to light weighted of data which are appropriate in real-time calculation. We implemented the function of Normal vectors and Triangle Mesh to generate surfaces and Alpha Shapes algorithms to process 3D modeling.

중첩 불일치 평가기준으로서의 계수공제영상의 계조도 표준편차 연구 (The Study of Standard Deviation of Gray Scale Histogram in Digital Subtraction Radiography as a Test Parameter for SuperimpoSition Error)

  • 조봉혜
    • 치과방사선
    • /
    • 제29권2호
    • /
    • pp.417-422
    • /
    • 1999
  • Purpose : The aim of this study was to assess the validity of standard deviation of gray scale histogram in digital subtraction radiography as a test parameter for superimposition error. Materials and Methods : Twenty periapical radiographs were used as baseline images and they were copied to exclude the influence of exposure geomety and contrast differences. These subsequent images were linearly displaced by 0.1-0.5 mm in the x-. y- and xy-directions, rotated by 0.5-3° and distorted by angular contraction of 1-5° in x- and y-axis before subtraction. The standard deviations of gray levels in the subtraction images were obtained and paired t-tests were performed. Pearson correlation coefficients(r) were calculated between the standard deviations and the superimposition errors. Results : Linear displacement showed high correlation coefficients of 0.997, 0.997 and 0.995 in x-. y- and xy-axis respectively. Statistically significant different standard deviation existed among all linearly displaced groups(p<0.05). Distortion showed relatively low correlation coefficients of 0.982 and 0.959 in x- and y-axis. The standard deviations between the two distortion groups were statistically significant different(p<0.05). Conclusion : Standard deviation of gray level distribution in digital subtraction images is satisfactory but not perfect similarity measure to assess the superimposition errors.

  • PDF