• Title/Summary/Keyword: Standard lux

Search Result 39, Processing Time 0.026 seconds

A Study on the Illumination of Household and Research on the Actual Conditions of Wearing Spectacles in Dwellers (주택의 조명과 거주자의 면경착용 실태조사연구)

  • 석호작;남철현
    • Journal of Environmental Health Sciences
    • /
    • v.17 no.2
    • /
    • pp.54-66
    • /
    • 1991
  • As a result of measuring illumination and making up a question at home visit directly by investigator who trained over twenty days period from October 4 to 24, 1990, in order to render help which illumination problem against house, society against eyes or framing of health instruction potgram by seizing natural lighting actual conditions of house and actual conditions of wearing spectacles and by investigating interrelationship, I can summarize as follows. 1) In property of investigation subject, woman 66.9%, In an age, the twenties was largest of 27.4%, the forties was 20.2%, the fifties was 18.6%, the thirties was 17.4%. In academic career, those of upper secondary school grauates was largest of 28.6%, those who possess university career was 25.9%, those who middle school career was 20.9%, decoding of Korean alphabet was 2%. 2) By a residence area, a big city was 43.3%, farming and fishing villages were 20.3%, the rest was a small town and the administrative office of town, township. In positon of house, the middle area was 43.6%, resident of suburb area was 38.0%. In form of house, a Korean-style house was 40.8%, a western-style house was 34.8%, an apartment house was 11.0%. In the a standard of living, the middle classes 77.2%, the lower classes were 15.3%. In residential house unit of area, from 21 to 30 unit of area was largest of 31.5%, from 10 to 20 unit of area was 19.9%, from 31 to 40 was 18.7%. 3) The wearing spectacles rate of study user was 44.1%. By the area, those who wearing spectacles was more than a half of 50.8% in the resident of big city area. As passing from the farm area to the city, that is being resident of big city was high wearing spectacles rate. In position of house, as being residence in central street showed high wearing spectacles rate. (central street was 51.5%, the middle area was 44.5% and the suburb area was 40.1%.) It seemed similarity difference a variable by position of house from wearing spectacles in standard of 1%. By form of house, wearing spectacles rate those who resident in apartment house was 49.5%, that rate those who resident in a western-style house was high of 49.0%, that rate those who resident in a Korean-style house was the lowest 39.0%. By social position of resident in room, in students case who study showed very high, as university students were very high of 62.3% idn wearing spectacles rate, middle and high school students 'were 50.0%, members of society were 47.6%, workers 20.3%. It seemed similarity difference from academic career in standard of 1%. By an age, the thirties was high of 54.1% in wearing spectacles rate, the twenties was 43.2%, the teenage was the lowest of 11.8%. 4) In illumination of study, over 200Lux was high of 40.1%. but below 99Lux which inappropriate illumination to see the books was 32.4%. Average by area, below 99Lux was 22.7% and over 400Lux was 50.0% in case of wooden floor. As examine by area, below 99Lux was high of 27.0% a case of wooden floor in the big city area, it was not good in illumination passing from the farm area(15.0%) to the city(19.0%). Average illlumination by area of the main living room below 99Lux was high of 37.5%, less than 200Lux was 58.5% of whole. In general, illumination of the main livingroom was inappropriate. By area, the big city was 32.5% below 99Lux, the middle and small city area were 33.8%, town and township area were 45.0%, farming and fishing area were 42.8%. By area, in the big city, illumination of study was 52.5% over 200Lux and 28.9% below 99Lux. In case of the middle and small city, study user of below 99Lux was 38.8% and over 200Lux was 46.9%. In case of the seat of town township, below 99Lux was 34.1% and over 200Lux was 39.7%. In case of farming and fishing area, illumination of study was 33.4% below 99Lux and 48.4% over 200Lux. It tends to high rate of inappropriate illumination. 5) By position of house, in case of wooden floor, less than 100Lux was 24.5% in central street. It was bad illumination than others position of house. In case of the main livingroom, less than 100Lux was 40.4% in the suburb area. It was bad iliumnation than others position of house. In case of study, less than 100Lux was 35.4% in the middle area, it was worse in illumination. In case of the main living room, is seemed similarity difference in standard of 1%. 6) By form of house, in case of wooden floor, illumination of less than 100Lux was 23.8% in a western-style house, it was bad illumination than others form of house. In case of the main livingroom, illumination of less than 100Lux was 47.4% in a Korean-style house, it was remarkably bad illumination than others form of house. In case of study, a Korean-style house was 38.8%, it was very bad illumination than others form of house. In case of the main livingroom and study, it seemed similatrity difference each as P < 0.01 and P < 0.05 in standard of 1%. 7) The wearing spectacles rate of those who use room of illumination over 400Lux was 40.7%, and that of those who use room of illumination less than 100Lux was 28.1%. It seemed similarity differecce in standard of 1%. 8) In period of wearing spectacles, 21.3% of total investigator-highest-was from before five years, 8.6% was from before three years. Among those who use of illumintion less than 99Lux, 34.0% began to wear spectacles from before two years 31.7% was from before five years, 30.3% was from before four years. It seemed similarity difference from period of wearing spectacles by illumination in standard of 1 %. 9) Among cause which sight grow worse, the first was that it was each 33.2% and 27.4% in response rate because watch TV nearly to wearing spectacles person and non-wearing person. The second was that a lot of seeing books was 25.3% in wearing spectacles person and response rate for dark illumination was 7.4% in nonwearing spectacles person. It seemed similarity difference in standard of 1%. (P < 0.01). 10) In experience which take medicine good for eyes, it was 50.1% in wearing spectacles person and 8.5% in non-wearing spectacles person. It seemed similarity difference in standard of 1%(P < 0.01). As we have seen above, inappropriate illumination can be a cause of wearing spectacles. Nevertheless, actually, is realities to indifferent against illumination of house. So it must learn knowledge about health obstacle of illumination through society instruction and school eduction against students as well as general residents. In case that natural lighting is inappropriate structural of house, we must be able to maintain appropriate illumination through artificial illumination. And so eyes which is core of human life have to be protected, related the authorities, related group, and all health medical personnel will organically cooperate with and make efforts.

  • PDF

Trend in glass bead and regulation of road marking, and suggestions for preparing an autonomous vehicle age (도로표시 규정 및 글라스비드 동향과 자율주행차량 시대를 대비한 제언)

  • Kang, Byeongguk;Kang, Seunggu
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.29 no.5
    • /
    • pp.229-237
    • /
    • 2019
  • For maintaining high visibility of lane, the high refractive index glass beads with excellent retro-reflectivity are usually applied on the road marking paint. The retro-reflectivity standard of general road marking is different in each country; it is defined as $240mcd/m^2{\cdot}lux$ based on white light in Korea and $250{\sim}300mcd/m^2{\cdot}lux$ in developed countries. In this paper, the recent trends on the manufacturing technology of glass beads suitable for autonomous driving age as well as the road marking regulations has been reviewed. Also, in preparation for the commercialization of autonomous vehicles in the future, the necessity of raising the standard value and improving the glass bead properties were proposed.

Measurement of MRI Monitor Luminance and MRI Room Illuminance with a Light Probe (Light Probe를 이용한 MRI 검사실 및 모니터의 조도와 휘도 측정)

  • Kim, Ji Min;Han, Ah Yung;Lee, Ha Young;Lee, So Ra;Kweon, Dae Cheol
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.5
    • /
    • pp.168-172
    • /
    • 2016
  • The purpose of the optimal environment of the MRI room to measured luminance and illuminance of the MRI room and the monitor. University Hospital (n = 6) of the MRI (n = 10) in the luminance and illuminance Light Probe Xi Unfors (Unfors Instruments AB, Billdal, Sweden) was measured by using the. Black luminance level and white level of illuminance is repeated three times in the middle of the side of the monitor to obtain the mean and standard deviation using a t-test statistical processing was of significance test. Monitor luminance and black level in the average $1.78cd/m^2$, the standard deviation was $0.85cd/m^2$, white level average of $43.58cd/m^2$, the standard deviation of $13.19cd/m^2$. Illuminance of MRI room was the lowest value measured in accordance with the 30.5 lux, the maximum value is 601.3 lux, mean was measured by a variety of 177.86 lux. Luminance and illuminance of the MRI room and monitor is found to have statistically significant difference (p < .05). In conclusion, refer to the recommended standard of MRI and room monitor luminance and illuminance and to create an optimal environment.

The Visual Performance Evaluation of the Work planes with the Automated blind Control in Small Office Spaces

  • Park, Doo-Yong;Yoon, Kap-Chun;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.14 no.1
    • /
    • pp.15-22
    • /
    • 2014
  • Among the various building envelope elements, the glass area takes up the largest portion in the office building design. However, a large area of glass can cause problems such as excessive solar radiation, thermal comfort, and glare. Thus it is important to install the glass area to an appropriate level, and control solar radiation and inflow of daylight with blind devices. This study aims to improve the visual performance of the work plane through the automatic control of the venetian blinds. A total of eight kinds of control strategies were chosen; Case 1 does not control the blinds, Case 2 with the blind slats fixed at the angle of 0 degree, Case 3 to 6 using the existing blind control programs, and Case 7 and 8 with improved blind control. Case 3 with 90 degrees had the best energy performance, but the average indoor illuminance was 113lux, which is below the standards. Cases 4 and 5 showed higher levels of interior daylight illuminance with the average of 281lux and 403lux respectively. However, the fixed angles may have difficulties controlling excessive direct sunlight coming into the room and may cause glare. Cases 6 and 7 used sun tracking angle control and cut-off angle control, and the average interior illuminance was measured 250lux and 385lux respectively. Case 8 used the cut-off angle control in an hourly manner, satisfying the standard illuminance of 400lux with an average interior illuminance of 561lux. It was evaluated to be the best method to control direct solar radiation and to guarantee proper level of interior illumination.

Visual Perception for TCO'03 Angular-Dependence Luminance Uniformity of TFT-LCDs

  • Hsu, Yu-Ju;Chen, Hsin-Ming;Cheng, Yung-Chiang
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.671-674
    • /
    • 2006
  • Due to the stricter requests of the human perception of images, many industrial standards such as TCO'03 have been made to survey the Flat Panel Displays (FPD) nowadays. The angular-dependence luminance uniformity is an important item to evaluate the performance of FPD. In this article, we focus on the above test item base on TCO'03 standard in the case of vertical direction of ${\pm}15^{\circ}$. With controlling the driving voltage toward the liquid crystals of TN-type TFT-LCD, there exists a voltage-driving range which can achieve the value of the $L_{max}/L_{min}$ at ${\pm}15^{\circ}\;{\leq}1.7$ readily. Both experiment and simulation have been well analysis.

  • PDF

Effect of the light qualities on the growth characteristics and yield in the cultivation of Lyophyllum ulmarium (만가닥버섯 재배시 광 종류에 따른 생육 특성 및 수량)

  • Park, Jae-Seong;Choi, Jae-Sun;Rho, Chang-Woo;Yun, Tae;Lee, Chang-Soo
    • Journal of Mushroom
    • /
    • v.8 no.4
    • /
    • pp.137-141
    • /
    • 2010
  • This experiment was carried out to clarify the effect of light qualities on the growth characteristics and yield of fruiting body in the cultivation of Lyophyllum ulmarium. The intensity of illumination by light qualities was in the order of white light(2,270Lux), yellow light(1,750Lux), blue light(460Lux) and red light(400Lux). An investigation of fruiting body showed these results that the pileus size and stipe diameter of fruiting body on CBM(Chungbuk mushroom)-1757 were much larger than Hypsizigus marmoreus, and an effect of yellow light seemed to be better than those of another light. In comparison with Hypsizigus marmoreus, the growth duration of CBM-1757 was shortened by 8 days which included 2 days for mycelial culture, 1 day for first pinning requirement and 1 day for growth. The growth duration in yellow light illumination was about 70 days showing the tendency of 2~4 days reduction. There were no differences in results such as number of effective stem and fresh weight. The yield of fruiting body per bottle in CBM-1757(95.6g) was little higher than Hypsizigus marmoreus(94.8g). By a white light's standard, the yields of blue and red light illumination were decreased by 2~9%, but that of yellow light illumination was increased by 8%. The chromaticity results showed that brightness, red and yellow coloration of CBM-1757 were higher than those of Hypsizigus marmoreus, and yellow light treatment was more effective than another light.

  • PDF

Study on the Gathering Effects of Anchovy Scoop Net in the neighboring waters of the Cheju Island (제주도 근해 멸치 분기초망의 집어효과에 관한 연구)

  • SOHN Tae-Jun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.21 no.3
    • /
    • pp.184-192
    • /
    • 1988
  • Anchovy, Engraulis Japonica were caught by scoop net with fishing lamp in the surrounding water of Cheju and Seogwipo, and their gathering depth, gathering effects, change of catch by the age of the moon and submarine illumination were investigated from May to August 1985. Fish finder (SR-385) and fishing lamp (1 Kw incandescent) were set up at one meter of starboard of scoop net and one meter ahead of the prow together with two meters above the water surface respectively. The submarine illumunation was measured at 2m interval to both vertical direction of 0~18m and horizontal direction of 0~12m form the standard point which is to be 0.1m depth right under the fishing lamp. The catch of anchovy by scoop net was almost $90\%$ of total amount during the early period and the late period in moon age while as low as $10\%$ only was cought during the middle period. The catching depth of anchovy shoals by scoop net with fishing lamp was approximately 2~5m and submarine illuminations were 20~42 Lux, 24~48 Lux in Cheju and Seogwipo respec lively. Submarine illumination which could be cought by scoop net with fishing lamp should be 7~12 times lighter than before gathering since the shoals swiming at 10~15m depth which is 1.7~7 Lux illumination made by 1 Kw. AC 100V incandescent lamp, a surface gathering lamp of 2m high above anchovy scoop net came up to 2~5m depth which is 20~42 Lux illumination. The catching depth of anchovy by scoop net was 2~3m and this could be increased to 4m even though the AC voltage was decreased from 100V to 80V at final fishing stage.

  • PDF

Night Visibility Evaluation of Phosphorescent Road Line Markings (축광 노면표시의 야간 시인성 평가를 위한 기초 연구)

  • Lee, Yong Mun;Kim, Sang Tae;Jeong, Wang Seong;Kim, Heung Rae
    • International Journal of Highway Engineering
    • /
    • v.18 no.4
    • /
    • pp.69-75
    • /
    • 2016
  • PURPOSES : In this study, we evaluated changes in the retroreflectivity and luminance of phosphorescent road line markings with changes in glass beads and line marking thickness. METHODS : The color of line markings affects their retroreflectivity. Using a chromaticity test, we conducted the analysis of whether phosphorescent road line markings adhered to the "KS M 6080" standard. Then, we measured the dry retroreflectivity and wet retroreflectivity for various glass bead refractive indices. We conducted wet retroreflectivity test using the EN 1436 standard as the basis. We also conducted luminance tests for different glass bead refractive indices and line marking thicknesses. RESULTS : 1. Phosphorescent road line markings specimens satisfied the "KS M 6080" standard. 2. In dry retroreflectivity test, phosphorescent road line markings sprayed with glass beads satisfied the national police agency standard ($240mcd/(m^2{\cdot}Lux)$). Wet retroreflectivity test results showed that except for one type of No.1 glass beads, phosphorescent road line markings specimens sprayed with glass beads of one type of No.3 and two types of No.1 satisfied the national police agency standard ($100mcd/(m^2{\cdot}Lux)$). 3. Phosphorescent road line markings had higher retroreflectivity than non-phosphorescent road line markings in the dry condition. 4. Phosphorescent road line markings sprayed with glass beads demonstrated improved luminance. Luminance increased with higher glass bead refractive index and with increased line marking thickness. However, when the thickness crossed a certain threshold, phosphorescence ceased to increase; this is a characteristic of the phosphorescence phenomenon. CONCLUSIONS : Visibility across short distances can be ensured when phosphorescent road line markings are sprayed with glass beads, because of the retroreflection phenomenon. It is also possible to ensure far visibility using phosphorescent road line markings.

A STUDY ON THE ILLUMINATION OF DENTAL CLINIC (치과 진료실의 조명에 관한 실태 조사연구)

  • Choi Jong-In;Kim Yu-Lee;Dong Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.4
    • /
    • pp.374-382
    • /
    • 2006
  • Purpose: This study was designed to investigate the present conditions of illumination techniques in dental clinics in order to contribute improvement of operating environment. This study also aimed exploring qualitative and quantitative luminous intensity required for color temperature in dental clinic illumination, which was a critical part of esthetic dentistry. Materials and methods: A total of forty-eight local dental clinics were selected for sampling a) luminous intensity, and b) color temperature. The author measured the luminous intensity and the color temperature with lux meter and color meter respectively between 12pm and 2pm. The dental unit chair placed in the general operation positions were kept the distance 60 cm then all dental units were measured three times and averaged. The author measured the luminous intensity and color temperature with both common dental operating light and then without operating light in different office environments. The study was conducted under three conditions: 1 artificial illumination in clear day light 2. artificial illumination in cloudy day light, and 3. artificial illumination alone. Results : The results obtained were as follows. 1. The average luminous intensity in dental clinic lighting was 425 lux which was not sufficient to produce the optimal shade of the patient's teeth. Furthermore, the average luminous intensity even in full operating lighting was 9532 lux which fell short of the required level of 10,000 lux. 2. The average color temperature of all dental clinics surveyed was 5169 K which met the optimal range. However, only 33.3% fell in the correct region between 5,000-5,500 K as 25% were over 5,500 K and 41.6% were below 5,000 K. As a result, 66.7% were under insufficient color temperature conditions. 3. The dental unit chair placed next to a window, hence exposure to natural lighting, had significantly higher luminous intensity and color temperature compared to the dental unit chair which didn't have a window or natural lighting. 4. The data analysis revealed that only 6.3% of the dental clinic were met the standard of the average luminous intensity and color temperature.

Study on the Minimum Recursive Reflection Performance according to the Color of Road Surface (노면표시 색상에 따른 최소재귀반사성능 연구)

  • Han, Eum;Kang, Jong Ho;Kim, Cheong Ho;Park, Sungho;Yun, Ilsoo
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.19 no.6
    • /
    • pp.37-48
    • /
    • 2020
  • Eight colors prescribed by the Enforcement Rules of the Road Traffic Act and the group standard were tested to secure the minimum recursive reflectance performance standards when drying and wetting. The results were calculated to be 260.8 (mcd/㎡·lux) when drying white and 154.6 (mcd/㎡·lux) when wet. Yellow was 67% compared to the white reflective performance when drying. Wet poetry was 79 % and 59 %, respectively. In the case of blue, it was 64% in the case of white versus 72% in the case of white. Wet poetry was 63 % and 72 %, respectively. The range of changes in reflective performance during wetting was higher than when drying, and the absence of glass grains was similar to the previous results. The new colors also have a standard value of more than 50% compared to the white color in red, orange, pink, light green, and green. Based on this, it was estimated that the minimum reflective performance criteria according to the color of the road markings would form the basis for the enforcement rules of the Road Traffic Act.