• Title/Summary/Keyword: Standard floor impact sources

Search Result 22, Processing Time 0.023 seconds

Prediction of Concrete Slab Acceleration and Floor Impact Noise Using Frequency Response Function (주파수 응답함수를 이용한 콘크리트 슬래브 가속도 및 바닥충격소음 예측)

  • Mun, Dae-Ho;Park, Hong-Gun;Hwang, Jae-Seung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.6
    • /
    • pp.483-492
    • /
    • 2014
  • Uncomfortable feelings of occupants by indoor floor impact noise in a residential building are not accurately represented by the floor impact noise from a standard impact source. It is due to the characteristics of standard impact sources, which are different from the impact forces produced by occupants. It varies significantly by impact source, and it is not easy to be replicated for testing. As a result, the indoor floor impact noise under different acoustic conditions cannot be directly compared. Using frequency response function(FRF), which represents the input-output relationships of a dynamic system, it is possible to examine the characteristics of the system. Especially, FRF can predict the response of a linear dynamic system subjected to various excitation. To determine the relationship between impact force and the corresponding response of dynamic system in residential building, the acceleration response of a concrete slab and the floor impact noise in the living room, produced by bang-machine and rubber-ball excitation, were measured. The test results are compared to the estimates based on FRF and impact force spectrum.

Selection of the standard impact sounds similar to the human impact sounds in reinforced concrete floors (실충격음과 표준충격원으로 발생된 바닥충격음의 비교)

  • Sato, Shin-Ichi;Lee, Pyoung-Jik;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1167-1172
    • /
    • 2007
  • This study investigates human floor impact sounds; not only the children's jumping and running represented by heavy-weight impact source such as bang machine and impact ball but also the high-heel walking and the light weight object dropping represented by tapping machine in the standard measurements. However, due to reliability problems as a standard impactor, bang machine has not been included in the new draft of ISO 10140 Part 3: Measurement of impact sound insulation. Therefore, the procedure to convert the floor impact sound level of the bang machine into that of the impact ball has been demanded because the bang machine has been only the standard heavy-weight standard impact source and much of its data has been collected, This study indicates that the use of impact ball is reliable and that the bang machine data can be successfully converted into the impact ball data in case of box-frame type reinforced concrete structures.

  • PDF

Investigation of receiving position in the measurement method for floor impact sound in a testing building (표준시험동 바닥충격음 측정위치에 대한 고찰)

  • Lee, Sin-Young;Yoo, Seung-Yup;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.964-968
    • /
    • 2007
  • The measurement of floor impact sound have been standardized in KS 2810-1 and 2. The height of receiving microphones position is specified in the standard as 1.2m which is almost half height of apartment rooms as a listening position. In this study, receiving positions are investigated by measuring the distribution of sound pressure levels at 792 receiving microphone positions in the standard testing building. Standard impact sources, tapping machine and impact ball, are driven on the center position in the source room where is located at the above floor. It was found that the distribution of sound pressure levels in the receiving room indicates significant deviation at different frequencies there is more than 5dB drop at 63Hz but 2dB rise at 125Hz at a height of 1.2m when the impact ball is driven, in the other case of a generating tapping machine there is more than 2dB rise at 125Hz at a height of 1.2m due to room modes.

  • PDF

A Study on Evaluation Method of Floor Noise Reduction and Blocking Performance for Apartment Buildings in Korea (국내 공동주택 건축물 층간소음 저감 방안 및 차단 성능 등급평가법에 관한 고찰)

  • Jung, Kyung-Tae
    • Journal of Korean Association for Spatial Structures
    • /
    • v.24 no.3
    • /
    • pp.69-77
    • /
    • 2024
  • The purpose of this study is to present a plan for reducing noise between floors of apartment houses in Korea and to examine the method for evaluating noise blocking performance rating between floors. The definition of floor noise and classification method of floor noise can be described, and floor noise can be distinguished into lightweight impact sound and heavy impact sound. The wall-type structure, which is mainly adopted in domestic apartments, relatively transmits vibration caused by impact sources rather than using columns and beams, so noise problems between floors are relatively higher than systems using columns and beams. Three representative methods for reducing and blocking floor noise are described, and criteria for evaluating the effectiveness of floor noise reduction by each method are described. In addition, the method for noise reduction and blocking grades for each construction method currently applied in Korea was described, and as a result, it was judged that the domestic rating evaluation method was not suitable for the current domestic situation, and a new evaluation method and standard were needed.

Deviation of sound pressure level in receiving room according to the heavy-weight floor impact sources and it's positions (중량 바닥충격음 충격원의 종류 및 위치에 따른 수음실 음압레벨 변화)

  • Ju, Mun Ki;Han, Myung Ho;Oh, Yang Ki
    • KIEAE Journal
    • /
    • v.9 no.4
    • /
    • pp.23-28
    • /
    • 2009
  • Standard sound source currently used in heavy-weight floor impact sounds that cause many social problems has excessive low-frequency energy within a range from 63 Hz to 125 Hz, and is difficult to evaluate and measure. To solve these problems, studies are widely performed using a new impact source, the impact ball. In this study, the sound fields in a receiving room were compared and analyzed according to the current impact source, the bang machine, and the impact ball. And deviation of sound pressure level according to the impact source positions were compared. In case of impact ball, the sound pressure level was lower at 63 Hz and below and higher at 125 Hz and above. The same trend was observed at the low-frequency range on the horizontal and vertical planes, regardless of the type of the impact source, which showed the influence of the room mode. There was a problem with the variations in the sound pressure level according to the size or shape of the receiving room. And it also shows that change of source positions may effect the single number rating scheme.

Floor Impact Noise Characteristics Depending on the Experimental Conditions Using Impact Ball (실험조건에 따른 임팩트 볼의 바닥충격음 변화 고찰)

  • Lee, Won-Hak;Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.30 no.2
    • /
    • pp.92-99
    • /
    • 2011
  • In Japan, bang machine has been considered to have problems about not only the impact force and frequency response which are different from the real impact sources such as children's jumping and running, but also damage in the wooden structure housing. Therefore, a new impactor for lower impact force to prevent demage in wooden structure housing was developed. The impact ball was adopted as the second standard impact source in JIS A 1418-2 and ISO 140-11. In the present study, floor impact sounds generated by impact ball with drop heights in four floors of mock-up building of Building Research Institute (BRI) similar to typical Japanese wooden structure housing were investigated and also compared to jumping sound. The results show that Impact ball sound dropped at 10 cm to 30 cm was most similar to jumping sound. And The impact sound levels at 250 and 500 Hz were more sensitive to drop height than other lower frequencies. The error that may occur from the difference of height of 10 cm up and down based on the standard drop height caused by the impact ball operated by human hands was approx. 1 dB or less only in its value of characteristic, but it must be carefully taken into Impact ball in the Korea Standard.

Characteristics of Impact Force and Floor Impact noise for Man Walking and Standard Impact Sources (보행과 표준중량충격원의 충격력 및 바닥충격음 특성)

  • Park, Hong-Gun;Mun, Dae-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.216-224
    • /
    • 2014
  • 층간소음의 대부분의 원인이 아이들 뛰거나 발걸음으로 나타나고 있어 층간소음 저감을 위한 선행 연구로 층간소음의 주요 충격원인 보행 행위에 대한 정밀한 연구가 필요하다. 성인 보행 충격력과 그에 따른 바닥충격음을 계측하여 보행하중이 바닥충격음에 영향을 주는 요소를 분석하였다. 보행하중 중 발 뒤꿈치 충격력은 전체 충격하중을 주파수 특성을 대변할 수 있는 임펄스 형태의 하중으로 충격력은 뱅머신 또는 고무공보다 낮지만 1 차 영점(First zero)이 80Hz 정도로 높아 유효 가진 주파수 대역이 표준 중량충격원 보다 높았다. 구조물과 수음실의 고유모드 특성으로 인해 외부 충격에 대한 구조체 진동 및 음압의 공진 현상이 발생되기 때문에 공진 성분이 포함되는 바닥충격음 레벨은 순수 충격력 특성인 보행 또는 표준 중량충격원의 옥타브 밴드 충격력 폭로레벨과는 전혀 다른 주파수 특성을 나타내었다.

  • PDF

Measurements of Floor Impact Noise Using a New Impact Ball (고무공 충격원을 이용한 바닥충격음 측정)

  • 정정호;전진용;류종관
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.208-213
    • /
    • 2003
  • The purpose of this study is to review the use of a new standard impactor, the impact ball, in evaluating heavy-weight impact noises in reinforced concrete structures. A survey revealed that children running and jumping are the major heavy-weight impact sources in multi-story residential buildings. The noise from the impact ball was measured and psychoacoustically assessed. The relationship between the noise levels and the subjective responses was also investigated. Results showed that the noise from the impact ball is similar to the noise of children running and jumping. It was also found that the noise level of the impact ball is slightly higher than the noise level of a bang machine, although the impact ball has a lower impact force.

  • PDF

Establishing Evaluation Modifiers for the Annoyance Responses to Heavyweight Impact Noise (Annoyance 반응에 의한 중량충격음 평가척도 구성)

  • Kim, Kyoung-Ho;Jeong, Jeong-Ho;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.917-917
    • /
    • 2003
  • The auditory experiments based on the subjective annoyance responses were undertaken for the establishment of the adverb modifiers of the heavy-weight impact noises. The standard heavy weight impact noise, impact ball noise and adult walking noise were recorded by dummy head at a newly-built apartment and were presented to the subjects by headphones. The levels of the three impact noises were varied from 30 to 60㏈(A) and the subjects matched one of the adverb modifiers to each level of the noise sources. As a result, seven scale modifiers were established and the intervals between the modifiers were found as equal. In addition, it was found that the lower annoyance noise limits for the heavyweight impact, impact ball and walking were 40-45㏈ (L$\sub$I, Fmax. AW), which is 6㏈ lower than in the previous study. The background noise level was as low as 21㏈(A) in the test booth, therefore, the testing conditions need to be concerned for evaluation of floor impact noise.

  • PDF