There are no International Standards or Criteria pertaining to fires inside tunnels at the moment, but there are some fire-related regulations in some advanced countries such as Germany and the Netherlands where some fire-related studies have been expedited. Germany has established regulations related to the safety of structures by stipulating Fire Curves of RABT and EBA Tunnels. Also, the Netherlands has established the resistance capacity of structures by stipulating RWS curve so that they can prevent the adjacent area from being damaged due to a tunnel collapse. Hydrocarbon Fire Curve is the standard assessing the behaviour of a structure in a serious fire, by increasing the heating speed and the maximum temperature of ISO 834 Curve, while MHC Fire Curve, which was established in France, realizes more serious fire conditions. In this study, we aimed to develop the basis of full-sized experiments, with which you can assess the fire-resisting capacity against the fire strength of concrete PC panel lining, through the realization of various tunnel fire curves as mentioned above, by developing the heating furnace suitable for the requirements of Fire-Resisting Standards, with which you can assess the fire damage of tunnel concrete lining. We have developed various conditions of the heating furnace and the method to install a thermo couple within the furnace based on EFNARC and KS F2257-1. We have also conducted a calibrating experiment in order to secure its reliability.
In this study, fire resistance of steel fiber reinforced concrete was investigated Cylindrical and prismatic specimens made of Ordinary Portland Cement plain concrete and steel fiber reinforced concrete were exposed to heating in accordance with a standard time-temperature curve as specified in KS·F22 57, method of fire resistance test for structural parts of buildings, the period of heating was 1 hour and 2 hours. After the fire resistance test, mechanical properties of specimens such as compressive and bending strength, stress-strain curve, static and dynamic modulus of elasticity and bending toughness were investigated. Also the cracks and spallings of the specimens were observed. From the test results, it was confirmed that steel fiber reinforced concrete has a excellent fire resistance than plain concrete in the view of higher residual strength of concrete and smaller crackings because of steel fibers in concrete.
Recently, it increases in use of CFT(Concrete filled steel tube, below CFT) that is an excellent internal force and deformation capacity because material and method are required to be diversification and High-Performance according to increase the super-high structure. And it is proposed to use high-strength Concrete Filled steel Tube Column. But it is difficult quantitative evaluation about fire-resist performance of CFT because steel tube bind concrete. Also, the case of high strength CFT is feared that spalling occur inside. Therefore, this study made CFT specimen that determine the factor(which is strength of concrete) and then CFT column was exposed to heating controlled as closely as possible the ISO-834 standard fire curve. Also, it tried to analyze internal temperature through nonlinear transient heat flow analysis.
본 연구는 도시철도 터널내 화재시 구조체의 내화성능을 평가하기 위한 기준을 제시하고자 실시하였다. 현재 국내 도심의 지하철 터널 구간은 135km로써 그 규모가 세계 4위이며 대도시들의 도시철도 터널건설의 증가와 그 연장이 길어짐에 따라 터널 내 화재사고가 갈수록 높아지고 있는 상황이다. 하지만 국내에는 도시철도 터널 화재에 대한 내화성능평가에 기본적으로 적용되는 시간-온도 곡선이 없다. 따라서 본 연구에서는 국내 도시철도 터널의 통행량, 차량 종류 등을 고려한 열방출율을 기초로 외국에서 제시된 시간-온도 곡선을 검토하였으며 국내 실정에 맞는 설계화재 모델을 제시하였다. 또한 제시된 설계화재모델에 대해 수치해석을 통하여 화재시 도시철도 터널 구조체의 온도분포를 산정하였다.
본 연구는 도로터널 내 화재시 콘크리트 구조체의 내화성능을 평가하기 위한 기준을 제시하고자 실시하였다. 현재 국내에서는 지형특성 및 환경친화적인 도로건설로 도로 터널의 수가 빠른 속도로 증가하며, 터널연장이 길어짐에 따라 터널 내 화재사고가 갈수록 높아지고 있는 상황이다. 하지만 우리나라에서는 터널 화재에 대한 적합한 시간-온도 곡선을 규정하지 못하고 있는 실정이다. 따라서 본 연구에서는 국내 도로의 통행량, 차량 종류등을 고려한 열방출율을 기초로 외국에서 제시된 시간-온도 곡선을 검토해 보았으며 설계화재 모델을 제시하였다.
본 연구에서는 철도터널내 화재시 터널내 구조체의 내화성능을 평가하기 위한 시간-온도곡선의 기준을 제시하고자 실시하였다. 현재 국내에서는 철도터널건설과 터널의 수가 빠른 속도로 증가하고 있으며, 터널연장이 길어짐에 따라 터널 내 화재사고가 갈수록 높아지고 있는 상황이다. 철도터널의 화재빈도수는 적지만 화재시 인명과 교통차단으로 인한 사회적 피해는 막대하다. 하지만 우리나라에서는 철도터널 화재에 대한 적합한 시간-온도 곡선을 규정하지 못하고 있는 실정이다. 따라서 본 연구에서는 국내 철도의 통행량, 차량종류 등을 고려한 열방출율을 기초로 외국에서 제시된 시간-온도 곡선을 검토해 보았으며 국재 실정에 가장 적합한 설계화재 모델을 제시하였다. 탄화수소(HC)시간-온도 곡선이 국내 철도터널의 설계화재모델로 가장 적합하였으며, 탄화수소 시간-온도곡선에 의한 철도터널 구조체의 온도분포를 예측하기 위하여 유한요소해석을 통하여 콘크리트터널 구조체의 구조성능을 검토하였다.
본 연구는 구획된 소공간유형의 EPS실에서 케이블 등의 가연성물질에 대한 화재특성을 시뮬레이션(FDS6)을 활용하여 진행하였다. 구획된 공간인 EPS실에서는 산소의 공급이 원활하지 않아 표준화재곡선에서와 같은 우상향의 연소곡선이 나타나지 않았다. 환기가 제한되는 상황에서 열방출율과 연기 방출량에 대한 시뮬레이션 결과는 상승과 하락을 반복하며 불안정한 형태의 복잡한 화재특성을 보였다. 화재시간은 화재하중에 비하여 길게 나타났다. 열방출율에 비하여 연기 방출량의 변화는 느리게 진행되었으나 전체적인 면에서 변화양상은 유사성을 보이는 것으로 확인되었다.
yLRC 합성기둥은 기존 합성기둥의 장점과 거푸집 공사의 절감을 가져올 수 있으며, CFT와 비교하였을 때 강재량 감소의 효과와 함께 콘크리트의 충전상태를 육안으로 쉽게 확인할 수 있는 등의 장점을 가지고 있다. 실험결과와 연구를 통하여 yLRC 합성기둥의 구조체로서의 내력은 검증이 되었으나 내화성능에 관한 연구는 수행되지 않았다. 이에 본 논문에서는 yLRC 합성기둥의 내화성능 평가를 위해 콘크리트 면적비, 보강판, 피복유무 등을 변수로 두어 실험과 해석을 수행하였으며, 실험과 해석결과를 비교 고찰하여 내화 성능 평가를 하였다.
화재와 같은 고온 시 구조부재의 붕괴를 방지함으로써 재실자와 소방관계자 그리고 재산을 보호할 수 있는 방법은 구조부재의 내화성능을 확보하는 것이며, 이는 시방적 내화설계방법인 내화시험을 통하여 확보되어 왔다. 그러나 내화시험에 수반되는 시험체 제작과 운반 그리고 막대한 시험 비용의 반복적 사용 등은 새로운 공법과 재료 개발의 문제점으로 대두되었다. 따라서 본 연구에서는 일반 등급(SS 400) 강재의 고온 시 항복강도, 탄성계수와 열전달 및 열응력 해석을 적용하여 H형강 보부재의 표면온도 상승 및 고온 시 내력 변화를 평가하였다. 또한 H형강 보부재의 길이 변화에 따른 고온 시의 보부재의 내력평가를 수행하여 각각의 길이변화에 따른 내력 변화의 차이를 평가하였다.
Jaiho Lee ;Byeongjun Kim;Yong Hun Jung;Sangkyu Lee;Weon Gyu Shin
Nuclear Engineering and Technology
/
제55권4호
/
pp.1571-1584
/
2023
In this study, a numerical analysis was performed as part of an international joint research project to reproduce a real cable tray fire that occurred in the heater bay area of the turbine building of a nuclear power plant. A sensitivity analysis was performed on various input parameters to derive results consistent with the sprinkler activation time obtained from the fire event analysis. For all sensitive parameters, the normalized sprinkler activation time correlated well with the power function of the normalized sprinkler height. A correlation equation was developed to identify the sprinkler activation time at any location when determining the slope or fire growth rate under the conditions assuming a linear or t-squared heat release rate (HRR) time curve. Various cable fire growth assumptions were used to determine which assumption was better to provide the prediction coincident with the information given from the fire event analysis in terms of the sprinkler activation time and total energy generated from cables damaged by fire. In the comprehensive analysis of all the sensitive parameters, the standard deviation of the input parameters increased as the sprinkler height decreased. Within the range of the sensitivity parameter values given in this study, when considering all sprinkler heights, the standard deviation of the cable model change was the largest and that of the overhang position change was the smallest.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.