초고층 건축물 소방안전관리의 기본방향에 관한 연구 (High-rise buildings in the general direction of the Fire Safety Management Study)

  • 최만철;김병석
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2011년도 춘계학술대회
    • /
    • pp.79-93
    • /
    • 2011
  • Unlike a general building high-rise buildings itself has a kind of risk. In this study, the risk of a number of high-rise buildings have fire safety management of the particular risks associated with looking for ways to minimize focused. Theoretical Study of the United States since the collapse of the WTC buildings, and be the center of the authentic country was. outside of the high-rise building fire safety and related issues, and measures were based on the theory of reference. Issues include voluntary arson. disaster management, building codes and fire regulations of the discrepancies, such as fire safety aspects are explained in terms of three kinds, and for it to take steps in the direction suggested an alternative for high-rise buildings. Although differences of opinion between departments will not be easy to fire and building regulations regarding conflicts of laws among other things, require immediate resolution, and high-rise buildings to create a standard for effective crisis management manual countermeasures will also be ensured.

  • PDF

FDS 열분해 모델을 이용한 콘칼로리미터(ISO 5660) 화재 시뮬레이션 (Fire Simulation by Pyrolysis Method of FDS for the Small Cone Calorimeter (ISO 5660))

  • 양성진;장정훈;강찬용
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.206-212
    • /
    • 2009
  • Chemical behaviors of each surface material for interior facilities affect to fire initiation and growth in general fire situation. These chemical behaviors were characterized by thermal properties (Heat release rate, Pyrolysis rate, specific heat, etc) which could be derived from experimental test. Especially, Heat release rate which indicates aspect of fire size is one of the most important property to asses fire hazard and protection needs. The cone calorimeter test (ISO 5660) has recently assumed to a dominant role in bench scale fire testing to obtain the Heat release rate of materials. This value could be calculated by the 'Oxygen Consumption Method' under various producing irradiances to each surface of materials. In this study, Process of the cone calorimeter test was simulated by Pyrolysis model of FDS (Fire Dynamics Simulator by NIST) base on the ISO 5660 international standard. Then, we could estimate the simulation method of FDS in case of single materials through the comparative study with test results.

  • PDF

Fire design of concrete encased columns: Validation of an advanced calculation model

  • Zaharia, R.;Dubina, D.
    • Steel and Composite Structures
    • /
    • 제17권6호
    • /
    • pp.835-850
    • /
    • 2014
  • The fire resistance of composite steel and concrete structures may be determined by using the simplified methods provided in EN 1994-1-2. For the particular situations not covered by the standard, an advanced calculation model might be applied, using special purpose programs for the analysis of structures in fire. The validation of these programs has always been an important issue for software developers, but also for designers and authorities. Clause 4.4.4 from EN 1994-1-2 refers to the validation of the advanced calculation models and states that these models must be validated through relevant test results. The paper presents the calculation of fire resistance of the composite columns in a high-rise building built in Romania, and focusses on the validation of the calculation model (computer program SAFIR), for this particular case. This validation, asked by the Romanian authorities, considers the available experimental results of a fire test, performed on a similar composite steel-concrete column.

초고층 건축물 소방안전관리의 기본방향에 관한 연구 (A Study on the general direction of Fire-Fighting Safety management in high-rise buildings)

  • 최만철;김병석
    • 대한안전경영과학회지
    • /
    • 제13권2호
    • /
    • pp.67-75
    • /
    • 2011
  • Contrast a general building high rise buildings itself has a kind of risk. In this study, the risk of a number of high rise buildings have fire fighting safety management of the particular risks associated with looking for ways to minimize focused. Issues include self fire protection. disaster management, building code and fire code of the mismatch, such as fire protection facilities aspects are explained in terms of three kinds, and for it to take steps in the direction suggested an alternative for high rise buildings. Although differences of opinion between departments will not be easy to fire fighting and building codes regarding conflicts of codes above all require immediate resolution, and high rise buildings to create a standard for effective risk management manual countermeasures will also be ensured.

가스충전소에서 작업복의 정전기 안전관리에 관한 연구 (A Study on the Safety Management of the Electrostatic in Working Clothes at the Gas Station)

  • 이금환;정재희
    • 한국안전학회지
    • /
    • 제24권6호
    • /
    • pp.39-44
    • /
    • 2009
  • In order to prevent fire and explosion due to the electrostatic discharge at the Gas Station etc. This result will be applied to standard in the future. Wearing the non-electrostatic removing wear, Charged voltage of human body is 3,980V(MIE is approximately 0.79mJ). There is a possibility of fire explosion because the MIE of LP gas is 0.25mJ. In accordance with using period(whasing times), Charged voltage is shown that propensity is increased. Electrostatic charge amount is upper standard($0.6{\mu}$C) of the hazard of electrostatic removing wear. There is a possibility of fire and explosion. Therefore, countermeasure and management are needed about gas station worker.

Combustible Gas and Visible Distance by Sprinkler Head for Safety of Gymnasium Workers

  • Ahn, Jae-Cheon;Kong, Ha-Sung
    • International journal of advanced smart convergence
    • /
    • 제10권3호
    • /
    • pp.232-244
    • /
    • 2021
  • This study analyzed the changes in carbon monoxide, carbon dioxide, oxygen and visual distance by presence of sprinkler heads and their types in the event of a fire in an indoor gymnasium. Based on carbon monoxide and visual distance that affects human bodies enormously, first, if there is no sprinkler head, carbon monoxide will reach 0.4% within five seconds and visual distance rapidly shrank within five seconds. Seconds, in the event of standard sprinkler heads, carbon monoxide gradually increased from 30 seconds onwards and visual distance rapidly shrank after five seconds. Second, Third, if there are special sprinkler heads, carbon monoxide fluctuated after opening the head and visual distance became 5m or below from 15 seconds. Finally, in the event of early response sprinkler heads, carbon monoxide fluctuated up and down at 3 seconds due to falling water drops. Visual distance shrank up to 5m or below at 6 seconds. In the future, time for operation of each sprinkler head shall be analyzed.

서점의 적재가연물의 연소특성에 관한 실험적 연구 (Experimental Study on Combustion Characteristics of Live Fire Load in a Bookstore)

  • 남동군
    • 한국화재소방학회논문지
    • /
    • 제25권5호
    • /
    • pp.47-53
    • /
    • 2011
  • 건축물 적재가연물은 종류 및 양 등의 특성에 따라 화재지속시간과 화재규모 등에 크게 기여한다. 서점은 다른 건축용도보다 가연물이 다량 적재되어 있으므로 화재발생시 화재위험성이 클 가능성이 있다. 그러나 한편으로는 서점 내부의 서적은 연소하면 탄화층이 형성되고 적재가연물량에 비해 노출표면적이 작기 때문에 화재시 열분해가스의 생성이 작을 가능성도 있다. 이러한 가능성을 다양한 실험을 통해 파악하여 서점의 화재안전설계에 합리적으로 반영할 필요가 있다. 따라서 본 연구에서는 서점의 성능위주설계에 활용하기 위하여 적재가연물을 재현한 시험체를 가열로에 넣고 ISO834-1:1999 표준가열곡선에 따라 가열하는 일련의 실험을 실행하였다. 이 실험 결과를 바탕으로 서점의 적재가연물의 연소발열성상을 파악하고 성능위주설계에 필요한 연소속도 및 열방출률 등을 제시하였다.

웨브 보강 형태에 따른 H형강 보부재의 내화성능에 관한 연구 (Study on Fire Resistance of H-Section Beams Filled with Concrete at Web)

  • 권인규
    • 한국화재소방학회논문지
    • /
    • 제25권5호
    • /
    • pp.76-84
    • /
    • 2011
  • 건축물 화재는 인명과 재산피해가 동시에 유발될 수 있는 인위 재해이며, 피해의 최소화하기 위해서는 건축물 설계단계부터 화재안전에 관한 요구사항 특히 내화성능을 충족해야만 한다. 강구조물에서의 보부재는 수평하중 전달과 바닥하중을 축부재로 전달하는 주요 구조부재이며, 주로 H형강으로 시공되고 있다. H형강의 내화성능은 내화피복 시공에 의해서 만족되고 있으나, 구조성능과 내화성능을 동시에 향상시킬 수 있는 콘크리트 충전 보부재의 내화성능에 관한 연구 그리고 작용 하중비에 따른 내화성능 연구는 미진한 실정이다. 따라서 본 논문에서는 H형강 보부재와 H형강 웨브에 보통강도 및 고강도 콘크리트가 충전된 H형강 보부재를 대상으로 내화성능과 하중비에 따른 한계온도 자료를 확보하여 향후 성능적 내화설계의 기초자료로 활용하고자 한다.

화재실험을 통한 주택용 연기감지기 응답특성에 관한 연구 (A Study on the Response Characteristics of the Residential Smoke Detector Depending on Controlled Fire Tests)

  • 사공성호;김시국;이춘하;정종진
    • 한국화재소방학회논문지
    • /
    • 제23권4호
    • /
    • pp.98-103
    • /
    • 2009
  • 본 논문은 연기감지기의 응답특성을 분석하여 주택용 화재감지기로 적합한지를 분석하고자 광전식연기감지기, 아날로그연기감지기, 단독경보형연기감지기를 시험체로 선정하여 UL 268에서 정하는 화재시험방법을 응용하여 화재성상(종이화재와 인화성액체화재)에 따른 연기감지기의 응답특성을 분석하고자 화재실험을 실시하였다. 실험결과 화재성상에 따라 연기감지기의 응답특성 차이가 나타나는 것을 확인할 수 있었다.

Developments in Fire Sprinkler Technology

  • Rice, Douglas
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.606-609
    • /
    • 1997
  • Technology in fire sprinklers has exploded. There is more private fire sprinkler research now than ever before. New technology in fire sprinklers has tested the existing standard and found that it was wrong in some cases, it has provided new sprinklers that control fire better while reducing the cost of the overall system. This expansion of the types and applications of fire sprinklers has created a great need for education for the Authorities Having Jurisdiction and the Engineer as they must be able to make informed decisions regarding this new technology. Significant research has been done at Factory Mutual Research Corporation and Underwriters Laboratory in the United States. Full scale fire testing is done to prove any new technology did not lower the level of protection of existing fire sprinkler system installations. In each and every case, the existing level of fire protection was the baseline against which the new sprinklers were tested. This level can not be lowered for the test to be considered a success. This is intended to be an overview of the developments in fire sprinklers. Although extensive detail is not included, the overall aspects of these developments can be discussed. The research that will be covered will include the following general subjects: high piled and rack storage sprinkler protection without in-rack sprinklers, extended coverage and quick response sprinklers for ordinary and light hazard occupancies, as well as special sprinklers and their applications.