• 제목/요약/키워드: Standard facility

Search Result 926, Processing Time 0.029 seconds

Dynamic Shear Behaviors on the Normally Consolidation Clay-Geosynthetic Interface (토목섬유-정규압밀점토의 접촉면 동적 전단거동 평가)

  • Bae, Hyogon;Jang, Dongin;Kwak, Changwon;Park, Innjoon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.12
    • /
    • pp.33-39
    • /
    • 2018
  • In this study, important characteristics were identified for the Geosynthetic-soil interface using overburden pressure and saltwater and fresh water to evaluate silt shear behavior of the Geosynthetic-soil interface. In addition, waste landfill can secure spaces for waste disposal in the sea and this spaces can be used for additional facilities which will be necessary in the future. Analysis of behavior characteristics on interface of Geosynthetic-soil shows that, if analyzed using standard consolidometers, the consolidation stress of fresh water increased significantly more than saltwater. When analyzed using cyclic shear apparatus, saltwater and freshwater in both conditions, the displacement value increases as the wire gauges become closer to the lower module, and the shear fracture tends to occur radically under saltwater conditions than fresh water. Therefore, seawater, fresh water that act on the interface of geosynthetic-soil, and installation of facility using geosynthetic should be considered as important parameters that are essential for the dynamic design factor of the water controlling facility.

Diagnostic Method for Logistics Services Level on National Industrial Complexes, Airports and Seaports (국가산업단지 및 수출입 공항·항만의 물류서비스 수준 진단방법 개발)

  • HUR, Sung Ho;JEONG, Seung-Ju
    • Journal of Korea Port Economic Association
    • /
    • v.35 no.1
    • /
    • pp.97-116
    • /
    • 2019
  • National industrial complexes, airports, and seaports are major logistics nodes and the availability of their logistics services is a key factor for the successful operation of entire supply chains. For this reason, the central government has established a plan for their development and is investing in development projects. However, some difficulties exist in project prioritization and investment plan creation owing to the absence of a clear appraising method. For a smooth flow of national logistics and efficient investment on facilities, it is necessary to diagnose the logistics facilities' present conditions and practice sustainable management. In this study, a diagnostic method for logistics services, which consists of service factors and facility factors, is proposed. Adopting the method, facility factors can be prioritized to improve facilities' services; further, a standard procedure is proposed to support decision making for effective investments in logistics facilities. The method is applied to actual logistics facilities (three national industrial complexes, three seaports, and two airports) and the results indicate that it can be effectively applied to actual logistics facilities.

A Survey on the Spaces in Police Substation for Improving Area Standards (지역경찰관서 면적기준 개선을 위한 실태조사)

  • Kang, Kyung-Yeon;Han, Gi-Sung;Lee, Kyung-Hoon
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.36 no.2
    • /
    • pp.3-11
    • /
    • 2020
  • The police substation includes work spaces for civil services, interviews, and meetings, etc, and private spaces for rest, showers and cafeterias and so on. Since a large number of rooms for each function should be installed in a relatively small building, it is important to develop an area standard for efficient space organization in consideration of the functional characteristics and usage patterns of each space. The purpose of this study is to suggest the way for improving the area standards for spaces in police substation based on the results of existing standards analysis and case study. For this objective, architectural documents of 161 police substations built after 2013 in Korea were comparatively analyzed. Sixteen of these facilities were selected for field survey and investigated how the workspace and private area were organized and used. The results of investigation showed that there were a number of problematic cases, such as spaces not installed or insufficient, spaces used for two or more functions, spaces installed even though they are not included in the standards. It was mainly due to the fact that several important spaces which had been installed in most police substations were not included in the existing standards. The ways for improvement were suggested like following four points: (1) Modifying the criteria for classifying facility size, (2) Modifying the lists of the required spaces, (3) Specifying the basis of calculation for each space in detail, and (4) Differentiating the way to organize spaces according to the facility size.

A Study in the legal standards of healthcare facilities in Korea, China, and Japan (한국·중국·일본의 의료시설 법적기준과 그 변화 과정에 관한 연구)

  • Cho, Junyoung;Lei, Qingyun;Yang, Naewon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.26 no.4
    • /
    • pp.39-47
    • /
    • 2020
  • Purpose: Korea, China, and Japan can be seen as a geopolitical community that has developed through various relationships in terms of history. However, nowadays, it seems that they are pursuing different societal goals resulting from the difference in political and social systems, demographic structures, and economic situations. The law provides the minimum standards for people's lives in the direction that the society pursues. Therefore, the aim of this study is to examine the architectural differences in medical facilities and their causes comparing the legal standards of medical facilities in Korea, China, and Japan. Methods: The subject of the study is Korea, China, and Japan's legal standards of facilities corresponding to the Korean medical service act; enforcement decree of medical service act; and enforcement rules of medical service act. The scope of the study is as follows: First, the facilities standards and the reason for the revision of the standards after the 1950s when the current system of each country was established are investigated and thus the changing trends of the facilities standards that each country has pursued are analyzed. Second, the range and level presented by the current facilities standards of each country are compared and the differences are analyzed. Finally, cases in which the differences in the legal facilities standards are reflected in the actual design are compared and the effect of the facilities standards of medical facilities on the architectural plan is identified. Results & Implications: Each country differs in the legal standards of facilities because of changes in demographic structure and experience of disease. Moreover, it is identified that differences in social operating systems, especially in the operating methods of medical facilities, affect the range and level enforced by the facility standards. When investigating and researching foreign standards of facilities and cases for foreign medical facilities, it is required that they should be analyzed in consideration of the social and cultural aspects of each country.

Estimation of Energy Recovery Rate of Municipal Waste Incineration Facilities through Measuring Instruments (계측기기 측정을 통한 생활폐기물 소각시설의 에너지 회수효율 산정 연구)

  • Kwon, Young-Hyun;Kang, Jun-Gu;Ko, Young-Jae;Yoo, Ha-Nyoung;Kwon, Jun-Hwa;Park, Ho-Yeun;Jeon, Tae-Wan;Lee, Young-Ki
    • Journal of Korea Society of Waste Management
    • /
    • v.35 no.8
    • /
    • pp.770-776
    • /
    • 2018
  • This study measured the energy recovery rate of each municipal waste incineration facility according to the revised energy recovery rate estimation method, which targeted four municipal waste incineration facilities (Unit No. 7). The results calculated by the measuring instruments were used for each factor to estimate the recovery rate, and the available potential of available energy was examined by analyzing the energy production and valid consumption. As a result of the low heating value, 2,540 kcal/kg was calculated on average when the LHVw formula was applied, which is approximately 116 kcal/kg higher than the average design standard of 2,424 kcal/kg. The energy recovery rate was calculated as 96.9% on average based on production and 67.5% based on effective consumption, and the analysis shows that approximately 29.4% energy can be used.

A Comparison on Detected Concentrations of LPG Leakage Distribution through Actual Gas Release, CFD (FLACS) and Calculation of Hazardous Areas (가스 누출 실험, CFD 및 거리산출 비교를 통한 LP가스 누출 검지농도 분포에 대한 고찰)

  • Kim, Jeong Hwan;Lee, Min-Kyeong
    • Applied Chemistry for Engineering
    • /
    • v.32 no.1
    • /
    • pp.102-109
    • /
    • 2021
  • Recently, an interest in risk calculation methods has been increasing in Korea due to the establishment of classification code for explosive hazardous area on gas facility (KGS CODE GC101), which is based on the international standard of classification of areas - explosive gas atmospheres (IEC 60079-10-1). However, experiments to check for leaks of combustible or toxic gases are very difficult. These experiments can lead to fire, explosion, and toxic poisoning. Therefore, even if someone tries to provide a laboratory for this experiment, it is difficult to install a gas leakage equipment. In this study we find out differences among actual experiments, CFD by using FLACS and calculation based on classification code for explosive hazardous area on gas facility (KGS CODE GC101) by comparing to each other. We develpoed KGS HAC (hazardous area classification) program which based on KGS GC101 for convenience and popularization. As a result, actual gas leak, CFD and KGS HAC are showing slightly different results. The results of dispersion of 1.8 to 2.7 m were shown in the actual experiment, and the CFD and KGS HAC showed a linear increase of about 0.4 to 1 m depending on the increase in a flow rate. In the actual experiment, the application of 3/8" tubes and orifice to take into account the momentum drop resulted in an increase in the hazardous distance of about 1.95 m. Comparing three methods was able to identify similarities between real and CFD, and also similarities and limitations of CFD and KGS HAC. We hope these results will provide a good basis for future experiments and risk calculations.

A Case Study on Product Production Process Optimization using Big Data Analysis: Focusing on the Quality Management of LCD Production (빅데이터 분석 적용을 통한 공정 최적화 사례연구: LCD 공정 품질분석을 중심으로)

  • Park, Jong Tae;Lee, Sang Kon
    • Journal of Information Technology Services
    • /
    • v.21 no.2
    • /
    • pp.97-107
    • /
    • 2022
  • Recently, interest in smart factories is increasing. Investments to improve intelligence/automation are also being made continuously in manufacturing plants. Facility automation based on sensor data collection is now essential. In addition, we are operating our factories based on data generated in all areas of production, including production management, facility operation, and quality management, and an integrated standard information system. When producing LCD polarizer products, it is most important to link trace information between data generated by individual production processes. All systems involved in production must ensure that there is no data loss and data integrity is ensured. The large-capacity data collected from individual systems is composed of key values linked to each other. A real-time quality analysis processing system based on connected integrated system data is required. In this study, large-capacity data collection, storage, integration and loss prevention methods were presented for optimization of LCD polarizer production. The identification Risk model of inspection products can be added, and the applicable product model is designed to be continuously expanded. A quality inspection and analysis system that maximizes the yield rate was designed by using the final inspection image of the product using big data technology. In the case of products that are predefined as analysable products, it is designed to be verified with the big data knn analysis model, and individual analysis results are continuously applied to the actual production site to operate in a virtuous cycle structure. Production Optimization was performed by applying it to the currently produced LCD polarizer production line.

Effect of the De-NOx Facility Operating Condition on NOx Emission in a 125 MW Wood Pellet Power Plant (125 MW급 우드펠릿 발전소에서 탈질설비 운전조건이 질소산화물 발생량에 미치는 영향)

  • Jeon, Moonsoo;Lee, Jae-Heon
    • Plant Journal
    • /
    • v.18 no.3
    • /
    • pp.52-61
    • /
    • 2022
  • This study tested the effect of de-NOx Facility operating condition on Nox emisiion in a 125 MW wood pellet power plant in Yeongdong Eco Power Plant Unit 1, which is in operation. As SNCR urea flow rate increased, NOx emission gradually decreased, but ammonia slip after SCR increased. The boiler under test has a structure that is unfavorable to SNCR operation due to the high internal temperature, and the optimum location of the nozzle will be required. SCR dilution air temperature change did not affect the amount of NOx generated. Increasing SCR ammonia flow reduced the NOx emission at SCR outlet and also increased the NOx removal efficiency. However, the ammonia flow rate of 111 kg/h, which does not exceed the ammonia slip its own reference limit, is estimated to be the maximum operating standard. The increase in SCR mixer pressure reduced NOx emission and the removal efficiency was also measured to be the most effective variable to inhibit NOx production.

  • PDF

Strategic Improvement of Harbor Floating Pier Facilities (항만부잔교시설의 전략적 운영 개선 방안)

  • Park, Doo-Jin;Kim, Jung Yee;Kim, Woo-Sun
    • Journal of Korea Port Economic Association
    • /
    • v.37 no.3
    • /
    • pp.105-116
    • /
    • 2021
  • Harbor floating pier is a structure in which one or several floating vessels are connected to have a port function so that ships can be bordered regardless of tide level in places where differences between tidal rocks are severe. There are 233 harbor floating piers in Korea, and 27.5% of harbor floating pier are over 30 years old. Harbor floating piers older than 30 years are potentially at high risk of accidents. However, there is no clear standard for disposal or sale of aging harbor floating pier, and the management regulations on the timing of maintenance inspection and repair are ambiguous. In this study, the AHP model was designed by classifying the problems and improvement factors of harbor floating pier facility operation through interviews with port managers and existing literature studies. The AHP analysis showed that the relative importance of the evaluation factors of the higher class was in the order of improvement of the legal system, improvement of operational management and technical improvement. This study can be used as basic data for improving the operation of Korea harbor floating pier facilities.

Standardization Analysis of 'NEC Article 690' for Photovoltaic Shutdown Technology (태양광(PV) 셧다운(Shutdown)기술 'NEC Article 690' 표준화 분석)

  • Yoon, Yongho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.3
    • /
    • pp.171-176
    • /
    • 2022
  • The communication signal for quick cut-off specification is defined as "design to support fast cut-off requirements of all applicable photovoltaic(PV) systems" in NEC 2014, NEC 2017 or the corresponding UL standard regardless of the system configuration. On the other hand, if you look at the domestic regulations related to new and renewable energy, the standards, regulations, and guidelines set by each institution are general, or only the parts necessary for the institution are being established and operated. There are many insufficient points to apply these things to photovoltaic facilities, and there are cases where excessive facilities are installed according to the design, inspection standards of supervisors and inspection agencies, and the skill level of inspectors. The internationally accepted IEC standards deal with various facility standards in detail. In each European country, there are separate facility regulations based on IEC. In particular, the performance and safety of devices are dealt with in detail, and in the case of 'NEC Article 690' applied in North America such as the United States, each item is described in detail. Therefore, in this paper, we will look at the details of the PV shutdown technology that is currently used and applied internationally.