• Title/Summary/Keyword: Standard facility

Search Result 926, Processing Time 0.026 seconds

A Study on the HEC(Hybrid ESE-Conductor) Method for Lightning Protection of Buildings (건축물의 낙뢰보호를 위한 HEC(Hybrid ESE-Conductor) 방식에 관한 연구)

  • Kim, Dong-Jin;Kim, Young-Sun;Lee, Ki-Sik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.146-152
    • /
    • 2008
  • The frequency of lightning is increased due to improbable weather condition and global wanning. This phenomenon increases economical damage as well as human damage. Advanced countries like europe and north america have applied the facility standard of lightning by accumulating a store of quantitative data about lightning research. Lightning facility is composed of the lightning accepting part for induction lightning, ground connected electrode which conducts lightning current. The lightning accepting part is composed of normal rod, horizontal conductor, ESE lightning rod. Moreover, lightning accepting part is taken to use by the method of protection. This paper suggests HEC(Hybrid ESE-Conductor) method which mixes horizontal conductor and ESE lightning rod. This is also discovered by experiment that the starting point of corona discharge current is low, so it is efficient for lightning protection comparing with other methods. Moreover, distribution of electric field is analyzed qualitatively by finite element method. It also results in the relation of the starting point of corona discharge current. Corona discharge current makes minute current about some ${\mu}A$ between the electrodes by the strength of electric field. Also it occurs insulation destruction of gas, and it is developed to the shape of streamer by increase of the strength of electric field. We can find that the initial occurrence of streamer and contact probability of lightning can have advantage after researching the starting point of corona discharge current and discharge current of lightning striking point. This research demonstrates that the suggested HEC method is economically competitive as a lightning protection facility, and it takes a capably perfect role.

A Study on the Derivation of the User-Oriented Agricultural Drought Assessment Criteria Using the AHP technique (AHP기법을 이용한 수요자 중심의 농업가뭄 영향 평가 기준 도출 연구)

  • Lee, Suk-Ju;Song, Jae-Do;Jang, Tae-Il;Sul, Dong-Moon;Son, Jae-Kwon
    • Journal of Korean Society of Rural Planning
    • /
    • v.24 no.4
    • /
    • pp.47-55
    • /
    • 2018
  • Currently in the drought evaluation, which is a supplier-oriented standard that applies storage rates of reservoirs, evaluation for users that use agricultural water is not done. Therefore, this study established drought evaluation items for drought evaluation based on farmers' judgement, conducted a survey on farmers and experts, compared and analyzed weighted value between two groups, and then classified the evaluation standards per each evaluation item. The agricultural drought evaluation items are 5 major items of water supply lapse rate, agricultural weather, agricultural irrigation facility, crop and soil, and 12 subsections for regional characteristics and opinions of consumers that use water to be reflected. The result of analyzing weighted value of farmers and experts' major items shows that farmers is agricultural irrigation facility(0.219), water supply lapse rate(0.211), agricultural weather(0.204), crop(0.183) and soil(0.183). Experts is agricultural weather(0.297), agricultural irrigation facility(0.202), water supply lapse rate(0.189), crop(0.162) and soil(0.150), which displays difference between the two groups. The agricultural drought criteria standards are established based on precedent studies and cases, and grades of evaluation items are 1st grade(extreme stage), 2nd grade(warning stage), 3rd grade(alert stage) and 4th grade(attention stage). The above analysis per each consumer-oriented agricultural drought evaluation item and the analysis on the standards of evaluation grades are expected to be used as a basic resource for establishing agriculture drought policy and selecting drought area in the future.

A Basic Study for Establishing Standards for Special School Facilities -Focusing on Case Studies and Advice- (특수학교 시설기준 수립을 위한 기초연구 -사례조사 및 자문을 중심으로-)

  • Meang, Joon-Ho;Kim, Sung-Joong;Song, Byung-Joon;Kim, Jae-Young
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.20 no.2
    • /
    • pp.11-21
    • /
    • 2021
  • In order to create future-oriented special school facilities with a high-quality educational environment in response to various changes and demands of the times, it is necessary to break away from the existing uniform and formal framework to find appropriate special school space. This study was a basic research to construct an active detailed model of new and creative educational space that reflects the changes of future society and educational direction. In this study, we proposed a criteria based on case studies and expert advice, deviating away from the limitations and problems that existing special schools' educational space had. The direction of plan was presented based on the compilation of expert consultation and analysis of best practice facility survey across the nation. Based on the results of this study, it is intended to maximize the effectiveness of educational policies in the long term by preparing a specific facility model for the establishment of special school planning standards.

The development of EASI-based multi-path analysis code for nuclear security system with variability extension

  • Andiwijayakusuma, Dinan;Setiadipura, Topan;Purqon, Acep;Su'ud, Zaki
    • Nuclear Engineering and Technology
    • /
    • v.54 no.10
    • /
    • pp.3604-3613
    • /
    • 2022
  • The Physical Protection System (PPS) plays an important role and must effectively deal with various adversary attacks in nuclear security. In specific single adversary path scenarios, we can calculate the PPS effectiveness by EASI (Estimated Adversary Sequence Interruption) through Probability of Interruption (PI) calculation. EASI uses a single value of the probability of detection (PD) and the probability of alarm communications (PC) in the PPS. In this study, we develop a multi-path analysis code based on EASI to evaluate the effectiveness of PPS. Our quantification method for PI considers the variability and uncertainty of PD and PC value by Monte Carlo simulation. We converted the 2-D scheme of the nuclear facility into an Adversary Sequence Diagram (ASD). We used ASD to find the adversary path with the lowest probability of interruption as the most vulnerable paths (MVP). We examined a hypothetical facility (Hypothetical National Nuclear Research Facility - HNNRF) to confirm our code compared with EASI. The results show that implementing the variability extension can estimate the PI value and its associated uncertainty. The multi-path analysis code allows the analyst to make it easier to assess PPS with more extensive facilities with more complex adversary paths. However, the variability of the PD value in each protection element allows a significant decrease in the PI value. The possibility of this decrease needs to be an important concern for PPS designers to determine the PD value correctly or set a higher standard for PPS performance that remains reliable.

A study on the Types of Urgent Isolation Ward (긴급치료격리병동의 평면유형)

  • Lee, Hyunjin;Kwon, Soonjung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.28 no.4
    • /
    • pp.61-69
    • /
    • 2022
  • Purpose: In response to the rapid spread of COVID-19 in 2020, the government supported facilities and equipment through the 'Urgent Isolation Ward Expansion Project'. Design and remodeling of efficient negative pressure isolation facilities had to be done in a short period of time, and the performance gap between facilities was very large because the types of hospitals and wards of existing medical facilities were diverse. In order to secure the stability of isolation wards between medical facilities and reduce the facility gap, guidelines for planning isolation wards considering the diversity of each hospital should be appropriately presented. In consideration of these points, this study aims to provide basic data for future remodeling guidelines for each plan type of the negative pressure isolation ward first. Methods: We analyzed the plans before and after the change of 13 case hospitals that performed the urgent care bed expansion project for COVID-19 confirmed patients. Before the remodeling, the current status of the facility was analyzed according to the type of corridor, the location of the nursing station, and the location of the elevator. After remodeling, the flow of medical staff and patients, the flow of entry and exit of clean and contaminated items, and the space of negative pressure and non-negative pressure areas. Results: The ward type was divided into three types according to the corridor type and room arrangement: double loaded corridor type with two side wards, race track type with one side ward, and race track type with two side wards. Based on these three types, the standard floor plan type of the isolation ward was proposed in terms of the location of the elevator bank and Nurse station. Implications: When the existing general ward is converted into a negative pressure isolation ward, this study can be a basic data to present customized guidelines for each ward type.

Hydraulic and hydrologic performance evaluation of low impact development technology

  • Yano, Kimberly Ann;Geronimo, Franz Kevin;Reyes, Nash Jett;Choe, Hye-Seon;Jeon, Min-Su;Kim, Lee-Hyeong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.325-325
    • /
    • 2020
  • Low impact development (LID) is a widely used technology that aims to reduce the peak flow volume and amount of pollutants in stormwater runoff while introducing physicochemical, biological or a combination of both mechanisms in order to improve water quality. This research aimed to determine the effect of hydrologic factors in removing the pollutants on stormwater runoff by an LID facility. Monitored storm events from 2010-2018 were analysed to evaluate the hydraulic and hydrological performance of a small constructed wetland (SCW). Standard methods for the examination water and wastewater were employed to assess the water quality of the collected samples (APHA et al, 1992). Primary hydrologic data were obtained from the Korea Meteorological Administration. The recorded average rainfall intensity and antecedent dry days (ADD) of SCW were 5.26 mm/hr and 7 days respectively. During the highest rainfall event (27 mm/hr), the removal efficiency of SCW for all the pollutants was ranging from 67% to 91%. While on the lowest rainfall event (0.7 mm/hr), the removal efficiency was ranging from -36% to 62%. Rainfall intensity has a significant effect to the removal efficiencies of each facility due to its dilution factor. In addition to that, there was no significant correlation of ADD to the mean concentrations of pollutants. Generally, stormwater runoff contains significant amount of pollutants that can cause harmful effects to the environment if not treated. Also, the component of this LID facility such as pre-treatment zone, media filters and vegetation contributed to the effectivity of the LID facilities in reducing the amounts of pollutants present in stormwater runof.

  • PDF

Efficient Evaluation Method of Operation Cost for Wastewater Treatment Plant by BTL Contract Type (하수처리시설 BTL사업의 합리적인 운영비 산정방안)

  • Kang, Leen Seok;Yoon, Sun MI;Kwon, Joong Hee
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.5D
    • /
    • pp.627-634
    • /
    • 2009
  • The BTL (Build-Transfer-Lease) contract of construction project serves as a part for early establishment of industrial foundation for social overhead capital. However, project cost of BTL contract is focused on initial construction cost. Accordingly, operation cost is lowly evaluated because there is no standard criterion for estimating maintenance cost for the facility. The low operation cost can be a factor that reduces service quality of facility operation. This study suggests a resonable method for estimating cost and manpower in the operation phase by using the existing practical data for wastewater treatment plant by BTL contract. The results of the study can be used for evaluating rough operation cost and manpower of similar plant project by facility size.

A Study on the Permit Method for a New or an Enlarged Facilities According to the Implementation of Air Pollutant Emission-Cap Regulation in Metropolitan Area (수도권 사업장 대기총량제 시행에 따른 신·증설 사업장 허가기준 개발 연구)

  • Kim, Hong-Rok;Yoon, Young-Bong;Ko, Byung-Churl;Shin, Won-Geun;Kim, Dong-Joong;Lee, Myung-Hwoon
    • Journal of Environmental Impact Assessment
    • /
    • v.16 no.4
    • /
    • pp.301-310
    • /
    • 2007
  • For the improvement of air quality in the metropolitan area, Korea has enforced the air pollutant emission cap regulation from the 1st of July, 2007, and the companies that intend to install a new or an enlarged facility in the metropolitan area will be restricted. However, the current regulation on permission does not describe a standard of judgement distinctly. In this study, therefore, a method of permission on the installation of a new or an enlarged facility was developed by supplementing the law in force based on the foreign cases. To develop a specific permit regulation and procedure, the developed nations' cases such as US, Canada, EU were reviewed thoroughly. Also, an appropriate method was suggested to apply domestically for a new or an enlarged facility permit within the regulations of the metropolitan special law. The method consists of first, calculating the possible permit quantity from the difference between an estimated annual emission cap and the annual emission provided by the implementation plan in each region. Second, permitting a new or an enlarged facility construction within the difference of the emission between the regional emission cap and the implementation plan in 2014. Third, distributing emissions allowable to each performance year based on the regional emission cap and the implementation plan in 2014. Fourth, making use of the emission difference between the implementation plan and the performance result in each year. Considering the general domestic conditions, the convenience of the permit authority and permitted companies, the most reasonable method was to use the fourth. To enforce the suggested permit method in a more flexible way, parts of the related regulations need to be revised and continuous research and analysis on the results from the implemented system and on foreign cases is necessary to develop this method a suitable system for domestic conditions and to settle the air pollutant emission cap system.

COBie-based Building Information Exchange System Framework for Building Facility Management (건축물 유지관리를 위한 COBie기반 건축정보교환체계 프레임웍 연구)

  • Kang, Tae-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.8
    • /
    • pp.370-378
    • /
    • 2020
  • The Construction Operations Building Information Exchange (COBie) collects and documents a large amount of information from different paths in one place during design and construction projects. This documented information is readily available as a means of continuously transferring data to the facility management systems used by building engineers. In this process, the COBie Worksheet, an open standard form, is used to input the information by simplifying the list required by the user. As a result, COBie was developed to improve dramatically how relevant information is obtained and updated to support operations, maintenance, and asset management at the design and construction stages. On the other hand, to use COBie, a great deal of manual work is required for information linkage and quality inspection with heterogeneous data models. These issues become obstacles to COBie-based facility management system development. This study analyzed the COBie information system and defined the framework for simpler operating maintenance information from BIM (Building Information Modeling). Moreover, the rules for facility management information submission, quality inspection, role definition of framework components, and information linkage were derived. COBie DB schema and support data linkages could be generated effectively based on the proposed framework in prototype development.

The Safety Management Status and Policy Directions for Sports Facilities in Gangwon Province (강원도 체육시설 안전관리 실태와 정책방향)

  • Kim, Tae-Dong;Kim, Heung-Tae
    • Journal of Korea Entertainment Industry Association
    • /
    • v.14 no.4
    • /
    • pp.265-288
    • /
    • 2020
  • Public sports facilities, which have increased in number due to continued government attention and investment, are used by a large number of residents in the province. However, the safety management in some facilities is limited due to being carried out with reference to safety management standard manuals as a mere formality. The purpose of this study was to analyze the current safety management status of public sports facilities in Gangwon and to seek out a policy direction that can be used safely by provincial residents. To this end. the study made a comprehensive review of central government and Gangwon government policy trends in sports facility safety management in Gangwon along with actual cases, from which it made the following suggestions for policy directions. First, it proposed the designation and operation of specialized institutions using locally established development and municipal companeie,. universities and cooperatives. and the training and fostering of safety managers for sports facilities. Secod, it proposed the establishment of a foundation to promote a sport facility safety culture such as designation of and commendation for excellent facility safety management on the provincial level. holding case presentations on safety and responsiveness. sports safety experience plazas, sports safety classes, and cartoons for public relations. Third, it proposed setting the foundation for a safety management system that takes into account the greater quantity of leisure sports facilities compared to other cities and provinces. Fourth, it proposed the establishment of an institutional basis to establish support ordinance for sports facility safety management that meets the local conditions in Gangwon. Fifth, it proposed safety management measures for sports facilities at the central government level in parallel with a basic plan for sports facility safety management tailored to Gangwon that matches the conditions on the ground in the region.