• Title/Summary/Keyword: Standard facility

Search Result 917, Processing Time 0.023 seconds

CFD study of the PTS experiment in ROCOM test facility

  • Carija, Zoran;Ledic, Fran;Sikirica, Ante;Niceno, Bojan
    • Nuclear Engineering and Technology
    • /
    • v.52 no.12
    • /
    • pp.2803-2811
    • /
    • 2020
  • With the aging of nuclear reactors, embrittlement of the reactor pressure vessel (RPV) steel, as a consequence of routine operations, is highly probable. To ensure operational integrity and safety, prediction and mitigation of compromising damage, brought on by pressurized thermal shock (PTS) following an emergency procedure, is of utmost importance. Computational fluid dynamics (CFD) codes can be employed to predict these events and have therefore been an acceptable method for such assessments. In this paper, CFD simulations of a density driven ECC state in the ROCOM facility are analyzed. Obtained numerical results are validated with the experimental measurements. Considerable attention is attributed to the boundary conditions and their influence, specifically outlet definitions, in order to determine and adequately replicate the non-active pumps in the facility. Consequent analyses focused on initial conditions as well as on the temporal discretization and inner iterations. Disparities due to different turbulent modelling approaches are investigated for standard RANS models. Based on observed trends for different cases, a definitive simulation setup has been established, results of which have been ultimately compared to the measurements.

DC Arc Characteristics Analysis according to U1699B Test Standardof the Status (태양광발전설비 DC 아크특성 분석)

  • Wan-Su Kim;Kwang-Muk Park
    • Current Photovoltaic Research
    • /
    • v.11 no.4
    • /
    • pp.118-123
    • /
    • 2023
  • The main cause of solar facility fires is arc, and in the last 3 years ('16 to '18), about 80% of domestic solar facility fires have been caused by arcs. The capacity of solar power facilities installed around the world continues to increase, and fires caused by arcs are also expected to increase as the solar power generation facilities that were initially installed become obsolete, In this paper, an arc generation test was conducted based on the UL1699B test standard. As a result of the test, the arc generation satisfied the minimum arc current according to the test conditions, and DC arc characteristics were analyzed through data such as arc voltage and arc current according to variables such as speed of moving electrodes and electrode spacing.

A Study on the behavior of the Elderly and the optimum scale of the Necessary space in Daycare Center (주간보호센터의 이용자 행동과 소요공간의 적정규모에 관한 연구)

  • Kil, Jong-Won;So, Kab-Soo
    • Korean Institute of Interior Design Journal
    • /
    • v.17 no.6
    • /
    • pp.152-160
    • /
    • 2008
  • The Cases of advanced nations which have advanced welfare policy, they have headed for the deinstitutionalization and the protection of the local society. So they have expanded and improved the various policies and welfare facilities to be able to keep daily life on the base of local area. Many problems have been caused by rising the average life span of the elderly in Korea now. Under the tendency, there have been many alternative proposals to solve the problems. One of those proposals, the deinstitutionalization theory that is rated the ideal way, is the community-based care than the care in facilities for the elderly. It shows that the most ideal facility for the care is Daycare center and that it matters the system of spatial construction and standard of the facilities. Under the undetailed Korean standard of facility design, it is very important that system of spatial construction to correspond to the needs of the users and standard of the facilities are prepared from the point of view of the standard design of the domestic facilities for the elderly. The study of the book grasps the regional present situation of the domestic Daycare center and surveys the tendency of the stay and features of occupation of the user there through some case, and aims to have a thorough grip of the spatial scale by the user's behavior. It is to utilize for a proposal for preparation of the space scale, and an institution standard corresponding to user's needs in a Daycare center.

Characteristics of Uplift Capacity of House Pipe Foundation according to Foundation Types and Soil Conditions (기초형식 및 지반조건에 따른 하우스파이프기초의 인발저항력 특성)

  • Song, ChangSeob;Jang, UngHee;Choi, DookHo;Kim, JungChul
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.62 no.1
    • /
    • pp.117-126
    • /
    • 2020
  • The area of facility horticulture in Korea is increasing rapidly, the single-span pipe house which uses galvanized steel pipe as the main rafters occupies 78.7% of the facility area. Lightweight structures such as the single-span pipe house are vulnerable to meteorological disasters such as strong winds, economic losses of the state, local governments and farmers are continuing as construction does not meet the design standards. In order to minimize economic losses in the horticultural specialty facilities sector, the Rural Development Administration has been operating the horticultural disaster resilient standard for horticultural specialty facilities since April 2007. The only standard for the pipe connector is the disaster resilient standard, there is no standard for the uplift capacity of the house pipe foundation and the research on it is also insufficient. The purpose of this study is to investigate the characteristics of uplift capacity according to the foundation type, compaction ratio and embedded depth through soil box test. The results of the maximum uplift capacity according to the type, compaction ratio and embedded depth can be used as the basic data for the basic design of the pipe house conforming to the disaster resilient standard. Due to the limitation of soil box test, it may be different from the behavior of pipe house installed on site. In the future, the field test and the actual pipe house should be made and supplemented by comparing this result with the field test values.

Study on the Applicability of Standard Design Response Spectrum Analysis Method for Pile-type Mooring Facilities (말뚝식 계류시설의 표준설계응답스펙트럼 해석법 적용성 연구)

  • Oh, Jeong-Keun;Jeong, Yeong-Seok;Kwon, Min-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.5
    • /
    • pp.27-36
    • /
    • 2020
  • The purpose of this paper is to study on the applicability of the standard design response spectrum from the response spectrum analysis method, mainly applied to pile mooring facilities. To this end, after performing the ProShake 1-dimensional site response considering various geological conditions, the current standard design response spectrum was compared, and the ground-pile model in time history and two-dimensional site response analysis using Abaqus were performed to analyze the dynamic behavior of the ground-pile and to examine the selection method of the reference surface of the response spectrum on the installed slope, respectively. As a result, it was confirmed that no problems were found in the applicability of the current standard design response spectrum and no improvements are needed as well when considering the characteristics of the ground-pile dynamic behavior and the slope of the pile mooring facility.

A Study For the Standardization Design of Ginseng Cultivating Facility for the Improvement of Farming Environment (영농환경 개선을 위한 인삼재배사 표준화 디자인)

  • 신택균
    • Archives of design research
    • /
    • v.16 no.1
    • /
    • pp.93-102
    • /
    • 2003
  • This thesis is a study for the standardization of the design of ginseng cultivating facility (also known as the sun off facility) for the improvement of farming environment. The core background of this study is to propose a basic study for introducing, for the first time, the modern ginseng cultivating facility that matches the position of korea as a main nation cultivating ginseng and to secure the production and quality value of Koryo Ginseng, which is a special world-level agricultural product of Korea, under the present WTO agricultural product open system. Right now, wood, rice straw, or vinyls, which are non-standardized or are for one-time use only are used. Therefore, as a concept of the design, 1 tried to revise the fact that these materials are being used to set up the facility repeatedly every year which is creating environmental pollution and wasting of our countries labor and resource. Concrete factors to be improved are as follows: First, standardization of the form and structure of mass production system; Second, introduction of new materials such as semi-permanent resin etc., for standardization of materials; 1 tried to make the above two factors into a shape based on a Korean image. As for the design, designed a standard unit model of the ginseng cultivation facility especially keeping in mind to design it so the facility can be freely connected and assembled according to the size and shape of the cultivation area.

  • PDF

The Plan on the Seismic Design of Electrical Facility Installed in the Building (건축물에 시설되는 수변전설비 내진설계 방안)

  • Kim, Gi-Hyun;Lee, Sang-Ick;Bae, Suk-Myong;Cho, Sung-Gook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.2
    • /
    • pp.89-95
    • /
    • 2009
  • Recently life and properties damage at Japan and China by generating earthquake. So earthquake generation trend and damage in the earthquake risk, and these are a growing interest in domestic. This paper analyzes domestic site and problems of earthquake measures for electrical facility at transformer vault which supply the power the emergence situation at generating earthquake. Also we present the seismic design of electrical facility using "Building construction design standard" in internal and "Manual of seismic design and construction for Building Electrical facility" in japan. This paper will be used detail seismic design of pipe and facility, reliability inspection plan for seismic design and construction of electrical facility.

A Study on Educational Facilities Resource Management System using Smart Devices (스마트 디바이스를 활용한 교육시설물 자원관리 시스템에 관한 연구)

  • Ryu, Chang-Su
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.1013-1014
    • /
    • 2015
  • Regardless of the strict enforcement of prevention education in accordance with the school facility management standard, safety accidents that lead to human and physical damages occur in current educational facilities because of teenagers with very low sense of responsibility and insensitivity toward fire and facility safety. To ensure educational facility safety, technology that will enable a fast work process and easy confirmation of electronic blueprints and related documents about the educational facility through smart devices at the site by various means is needed. This paper proposes a system design linked to the National Education Information System (NEIS) that uses the document conversion function, high efficiency resolution, and Internet of Things (IoT) to inspect and control the educational facility in the event of a safety accident through the Educational Facility Resource Management System (EFRMS) that manages the electronic blueprints, and various educational facility documents through various smart devices.

  • PDF

A Case Study on Swine Farms for the Planning of Gnotobiotic Pigs' Facility - Focused on Space Organization and Circulation System - (무균돼지 사육시설 계획을 위한 사례연구 - 공간구성 및 동선계획을 중심으로 -)

  • Kwon, Soon-Jung;Seong, Je-Kyung;Yeom, Su-Cheong
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.12 no.1
    • /
    • pp.49-59
    • /
    • 2006
  • According to the increase of demand for human organs such as kidney, heart, pancreas, joint, and cornea for therapeutic transplantation, the production of alternative organs based on Gnotobiotic Pigs gains a lot of concerns all over the world. However, it is not common to design and build Gnotobiotic Pigs' facility, and there are only a few those facilities and planning principles for them. Considering the situation above, this paper tries to develop planning guidelines for space organization and circulation system of standardized Germ Free Pig's facility on the bases of case analysis. The results of this study are as follows. At first, four swine farms including a Gntobiotic Pig's facility has been analysed from the point of space organization and circulation system. Secondly, the space zoning of Gnotobiotic Pigs' facility has been proposed into 5 groups : pigs' area, adminstration area, operating room and laboratory, service area, and mechanical area. Space components of each group have been presented also. Finally, circulation system of Gnotobiotic Pigs' facility has been explored from a operational point of view. This, also, includes human circulation, pig's circulation, and goods' circulation. This study has some limitations because it does not consider the SOPs(standard operational policies) of that facility to the fullest measure and does not suggest space area of each part, either. Despite of some weaknesses, it is expected that this study can give some useful guidelines for the design and planning of Germ Free Pigs' facilities.

  • PDF

A Study on a space utilization plan for screening clinic in public health center by means of the prevention of respiratory infectious disease - Focused on a negative pressured tuberculosis exam room (호흡기 감염병 예방을 위한 보건소 상시 선별진료소 활용방안 연구 - 음압 결핵 검진실을 중심으로)

  • Yoon, Hyung Jin;Han, Su Ha
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.27 no.4
    • /
    • pp.51-60
    • /
    • 2021
  • Purpose: Tuberculosis(TB) care unit in public health center should be carefully considered to be re-designed as an infection safety environment for both patient and healthcare workers. So, for the enhancement, this study analyses the facility requirements for co-using the screening clinic as a TB and other respiratory disease care unit. Methods: Not only screening clinic facility guidelines from "A Study for Standard Triage Design and Construction Document" but also the guidelines of TB care and related medical facility are reviewed; KDCA, CDC, ECDC and WHO as a TB care, and FGI and NHS for facility. The facility requirements are summarized space, approach, and mechanical requirement in order. By comparing the summary and screening clinic facility guidelines, supplementations are proposed for TB care unit setting. Results: The result of this study shows that both the space program and mechanical requirement of the screening clinic and that of TB care unit are almost identical and could be share, which include direct airflow or negative air pressure in an exam room. To increase functional and economical efficiency, however, it is necessary to consider a multi-functional negative pressured room, So care process may be re-designed based on a room type; face-to-face room or glass wall inbetween. Implications: The facility guidelines for TB care unit of a public health center should be developed to build a safe environment for infection control by reflecting its medical plan and budget.