• Title/Summary/Keyword: Standard dome

Search Result 29, Processing Time 0.026 seconds

Design of Integrated Control Software for Automated Observing System

  • Ji, Tae-Geun;Lee, Hye-In;Pak, Soojong;Im, Myungshin;Lee, Sang-Yun;Gibson, Coyne A.;Kuehne, John;Marshall, Jennifer
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.1
    • /
    • pp.57.2-57.2
    • /
    • 2017
  • Remote and robotic telescopes are the most effective instrument for astronomical survey projects. The system is based on the dynamic operation of all astronomical instruments such as dome and telescope control system (TCS), focuser, filter wheel and data taking camera. We adopt the ASCOM driver platform to control the instruments through the integrated software. It can convert different interface libraries from various manufacturers into a uniform standard library. This allows us to effectively control astronomical instruments without modifying codes. We suggest a conceptual design of software for automation of a small telescope such as the new wide-field 0.25m telescope at McDonald Observatory. It can also be applied to operation of multi-telescopes in future projects.

  • PDF

Flow Characteristics of Secondary Recirculation Region in a Liquid Ramjet Combustor (액체 램젯트 엔진 연소기내의 이차유동 특성)

  • C. H. Sohn;J. S. Hong;S. Y. Moon;C. W. Lee
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.05a
    • /
    • pp.137-140
    • /
    • 2003
  • The flow characteristics of secondary recirculation region in a liquid fuel ramjet combustor are measured using PIV method. The model combustor has two rectangular inlets that form 90 degree angle each other. The tested angles of the air intakes were 30, 45 and 60. Three guide vanes are installed in each rectangular inlet to improve the flow stability. The experiments are performed in the water tunnel test with the same Reynolds number as the case of Mach 0.3 at the inlet. PIV software is developed to measure the characteristics of the flow field in the combustor. The accuracy of the developed PIV program is verified with rotating disk experiment and standard data. The experimental results show that the secondary recirculation flow occurred at the front junction of inlet main stream and combustorchamber. The size of secondary recirculation regions are increased with increasing air inlet angles. Since the performanceof combustor is very dependant on not only the main recirculation in the dome region but also the secondary recirculation flow in a junction region, the optimal angle of the air intakes should consider the both recirculation size as a frame holder.

  • PDF

Preliminary Report of Observed Urban - Rural Gradient of Carbon Dioxide Concentration across Seoul, Suwon, and Icheon in South Korea (도시 - 전원간 이산화탄소(CO2) 농도구배 예비관측 결과)

  • Chung, U-Ran;Lee, Kyu-Jong;Lee, Byun-Woo
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.9 no.4
    • /
    • pp.268-276
    • /
    • 2007
  • Urban atmosphere may play as a harbinger for the future climate change with respect to temperature and $CO_2$ concentration. The Seoul metropolitan area is unique in rapid urbanization and industrialization during the last several decades, providing a natural $CO_2$ dome with increased temperature. This study was carried out to evaluate the feasibility of using the urban-rural environmental gradient in replacement of the IPCC mid-term scenario (after 30-50 years). For this, we measured atmospheric $CO_2$ concentration and air temperature at three sites with different degree of urbanization (Seoul, Suwon, and Icheon). Results from 11-month measurement can be summarized as follows: (1) The annual mean $CO_2$ concentration across 3 sites was in the order of Seoul (439 ppm) > Suwon (419 ppm) > Icheon (416 ppm), showing a substantial urban-rural environmental gradient. (2) The diurnal fluctuation in $CO_2$ concentration was greater in summer than in winter, showing the effect of photosynthesis on local $CO_2$ concentration. (3) The daily maximum $CO_2$ concentration was observed at 0500 LST in spring and summer, 0800 LST in autumn, and 0900 LST in winter, showing the sunrise-time dependence. (4) The observed hourly maximum $CO_2$ concentration averaged for the whole period was 446 ppm in Seoul at 0700 LST, while the minimum was 407 ppm in Suwon at 1500 LST. (5) Compared with the background atmospheric concentration of $CO_2$ in Anmyeon-do (377.4 ppm annual mean), $CO_2$ concentration of the study sites was higher by 14% in Seoul, by 10% in Suwon, and by 9% in Icheon. The observed $CO_2$ concentration in Seoul reached already 98% of the 2030-2040 projection (450 ppm) and 80% of the 2040-2050 projection (550 ppm) under the IPCC BAU scenario, showing a feasibility of using the $CO_2$ dome of Seoul as a natural experimental setting for the mid-term climate change impact assessment.

Quantification of Total Mercury in Antarctic Surface Snow using ICP-SF-MS: Spatial Variation from the Coast to Dome Fuji

  • Han, Yeong-Cheol;Huh, Young-Sook;Hong, Sung-Min;Hur, Soon-Do;Motoyama, Hideaki;Fujita, Shuji;Nakazawa, Fumio;Fukui, Kotaro
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.12
    • /
    • pp.4258-4264
    • /
    • 2011
  • The total mercury concentration ($Hg_T$) of surface snow samples collected along a ~1500 km transect in east Queen Maud Land was determined using inductively coupled plasma sector field mass spectrometry to address the behavior of Hg on the Antarctic Plateau. Due to the volatile nature of mercury, measures were taken against Hg loss from standard solutions by choosing appropriate container material and stabilizing agents. Glass bottles with Teflon-lined caps were superior to Teflon and polyethylene containers in protecting against Hg loss, but addition of gold chloride ($AuCl_3$) or bromine chloride (BrCl) was necessary to ensure preservation of Hg. As Hg loss was also observed in snowmelt samples, our analysis may underestimate the actual amount of HgT in the snow. Even so, the measured HgT was still very low (< 0.4-10.8 pg $g^{-1}$, n = 44) without a signal of depositional enhancement accompanying photo-oxidation of atmospheric elemental mercury in austral midsummer. Moreover, the dynamic variation along the traverse implies spatial and temporal heterogeneity in its source processes.

Reducing Donor Site Morbidity When Reconstructing the Nipple Using a Composite Nipple Graft

  • Lee, Taik Jong;Noh, Hyung Joo;Kim, Eun Key;Eom, Jin Sup
    • Archives of Plastic Surgery
    • /
    • v.39 no.4
    • /
    • pp.384-389
    • /
    • 2012
  • Background Numerous procedures are available for nipple reconstruction without a single gold standard. This study presents a method for reducing donor-site morbidity in nipple reconstruction using a composite nipple graft after transverse rectus abdominis musculocutaneous flap breast reconstruction. Methods Thirty-five patients who underwent nipple reconstruction using a composite nipple graft technique between July of 2001 and December of 2009 were enrolled in this study. To reduce the donor site morbidity, the superior or superior-medial half dome harvesting technique was applied preserving the lateral cutaneous branch of the fourth intercostal nerves. The patients were asked to complete a previously validated survey to rate the color and projection of both nipples, along with the sensation and contractility of the donor nipple; and whether, in retrospect, they would undergo the procedure again. To compare projection, we performed a retrospective chart review of all the identifiable patients who underwent nipple reconstruction using the modified top hat flap technique by the same surgeon and during the same period. Results Thirty-five patients were identified who underwent nipple reconstruction using a composite nipple graft. Of those, 29 patients (82.9%) responded to the survey. Overall, we received favorable responses to the donor site morbidity. Projection at postoperative 6 months and 1 year was compared with the immediate postoperative results, as well as with the results of nipples reconstructed using the modified top hat flap. Conclusions The technique used to harvest donor tissue is important. Preserving innervation of the nipple while harvesting can reduce donor site morbidity.

Finite Element Analysis on the Strength Safety of a Fuel Tank for Highly Compressed Gas Vehicle (초고압가스 차량용 연료탱크의 강도안전성에 관한 유한요소해석)

  • Kim, Chung-Kyun;Kim, Do-Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.6
    • /
    • pp.29-33
    • /
    • 2009
  • In this study, the strength safety of a composite fuel tank which is fabricated by an aluminum liner of Al6061-T6 materials and composite layers of carbon/epoxy-glass/epoxy composites has been analyzed by using a finite element analysis technique. In order to enhance the durability of the composite fuel tank, an autofrettage process was used and compressed natural gas was supplied to the prestressed fuel tank. The FEM computed results on the stress safety of autofrettaged gas tanks were compared with a criterion of design safety of US DOT-CFFC and Korean Standard. The FEM computed results indicated that the stress safety of autofrettaged fuels tanks shows instability at the dome zone and uniform stability at the parallel body, which provide an evaluation data for a strength safety of autofrettaged composite fuel tanks. The computed results show that the stress safety of 9.2 liter composite fuel tanks satisfied the safety criteria of four evaluation items, which are provided by US DOT-CFFC and KS and indicated a safe design.

  • PDF

3-D EM Modeling Using Approximate Integral Equation Method for the Models with Non 1-D Background Conductivity (1차원 이외의 배경 전기전도도 구조에서 근사 적분방정식을 이용한 3차원 전자탐사 모델링)

  • Lee Seong Kon;Zhdanov Michael S.
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.3
    • /
    • pp.207-217
    • /
    • 2005
  • We present a new approximate formulation of the integral equation (IE) method for models with variable background conductivity. This method overcomes the standard limitation of the conventional If method related to the use of a horizontally layered background only. The new approximate IE method still employs the Green's functions for a horizontally layered 1-D model. However, the new method allows us to use an inhomogeneous background with the IE method. The method was carefully tested for modeling the EM field for complex structures with a known variable background conductivity. It can find wide application in modeling EM data for multiple geological models with some common geoelectrical features, like a known inhomogeneous overburden, or salt dome structures.

Creation of an Environmental Forest as an Ecological Restoration

  • Lee, Chang-Seok;You, Young-Han
    • The Korean Journal of Ecology
    • /
    • v.24 no.2
    • /
    • pp.101-109
    • /
    • 2001
  • We created an environmental forest on the basis of ecological design around the incineration plant of Jindo Engineering and Construction Co., Ltd., which is located in Jeongwang-dong, Siheung-si, Kyunggi-do. To get ecological information of this site, physico-chemical properties of soil on salt marsh, which is located close to the syudy site and of forest soil transported from other sites for ecological restoration were analyzed. Texture of salt marsh and transported soils were loam and sandy loam, respectively. pH, organic matter, T-N, available P, and exchangeable K and Na contents of salt marsh and transported forest soils were 6.7 and 5.4, 4.1 and 0.4%, 1.0 and 0.3mg/g, 46.7 and 6.8ppm, 521 and 207ppm, and 3.8 and 0.5mg/g, respectively. Introduced plants were selected among the dominant species of forests and the species composing the potential natural vegetation around the present study site. Those plants were selected again by considering the tolerances to air pollution and to salt, and their availability. Selected trees were Pinus thunbergii, Sophora japonica, Celtis sinensis, Quercus aliena, Q. serrata, Q. dentata, and Q. acutissima. Selected sub-trees were Albizzia julibrissin, Koelreuteria poniculata, and Styrax japonica and shrubs were Rhododendron yedoense var. poukhanense, R. mucronulatum, Callicarpa japonica, Euonymus alatus, E. japonica, and R. schlippenbachii. On the other hand, introduction of herbs was not considered except for Liriope platyphylla, which was ornamentally planted in one site. Planting bed of mound type was adopted to provide the fine drainage system. Mound was designed to furnish litter, A, B, and C layers simuating the profile of forest soil. Slope of mound was mulched by rice straw of 2cm in thickness to prevent for sliding of litter and soil in cases of strong wind or heavy rain. Height of mound was designed to secure more than 1 m by combining A and B layers. Narrow zones, in which mound with stable slope degree cannot be prepared, was designed to equip the standard soil depth with the introduction of stone for supporting. On the other hand, plants with shallow root system were arranged in some zones, in which satisfactory soil depth cannot be ensured. Plants were arranged in the order of tree, sub-tree, and shrub from center to edge on the mound to make a mature forest of a dome shape in the future. Dispersion of plants was designed to be random pattern rather than clumped one. Problems on creation of the environmental forest by such ecological design were found to be management or inspection by non-specialized project operators and inspecting officers, and regulations for construction without ecological background. Alternative plans to solve such problems were suggested.

  • PDF

Evaluation of the Oxygen Transfer Parameters (α and F) of a Coarse Bubble Aeration System by Off-gas Column Test (Off-gas Column Test를 이용한 하수처리장 심층포기시스템의 산소전달 매개변수(α와 F)의 산정)

  • Kim, Chul Woong;Lee, Se Ho;Shin, Dong Rok;Lee, Ji Yong;Park, Jae Han;Ahn, Yoon Hee;Ko, Kwang Baik
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.6
    • /
    • pp.1119-1122
    • /
    • 2006
  • Aeration by using diffusers usually requires approximately 50~90% of the total electricity needed to operate WWTP (WasteWater Treatment Plant)s. Accurate evaluation of the oxygen transfer efficiency for an aeration system, and recommendation of a better alternative may help saving WWTP operational costs. Appropriate techniques and methods to achieve this purpose have not been introduced in Korea. In this study, in-process analysis was performed for a coarse bubble aeration system by the off-gas method to evaluate its applicability in Korea. To accomplish this analysis, an off-gas test, unsteady-state clean water test and steady-state off-gas column test was conducted and comparisons to other aeration systems were made. The ${\alpha}$ and the F estimated from the results of the unsteady-state clean water test and the steady-state off-gas column test were 0.61 and 0.90 respectively in a coarse bubble aeration system. The comparison of P.E tube diffusers laid out single spiral roll and ceramic dome diffusers laid out full floor coverage showed that the oxygen transfer efficiency of the coarse bubble aeration system was less than or similar to other aeration systems. But, airflow rates per unit area were 4~5 times greater than other aeration systems. In regards to the oxygen transfer efficiency for airflow rates per unit area, a retrofit to higher efficiency diffusers was urgently needed. This study showed proved that off-gas methods can apply to evaluate diffuser performances to estimate operating factors and to compare other aeration systems in Korea.