• 제목/요약/키워드: Standard ceiling system

검색결과 30건 처리시간 0.023초

내화천장구조 적용을 통한 석고보드 활용 확대에 관한 연구 (A Study on the Application of Gypsum Board through the Application of Fire Resistance Ceiling Structure)

  • 최동호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 추계 학술논문 발표대회
    • /
    • pp.217-218
    • /
    • 2019
  • Fire resistance ceiling system is the structure of which the ceiling installed under the slave of the structure has the fire resistance performance. Because of having the fire resistance performance, fire resistive coatings on steel beams can be reduced and large span structures can be constructed. So, it have advantages of convenience for construction, shorten for construction time and cost reducing. In foreign country, it is general that one system consisting of slave and ceiling is constructed as a fire resistance system, in these cases, gypsum boards are mostly used as ceiling materials. The purpose of this study was to explain the possibility of expanding the use of gypsum boards by securing fire resistance performance of these ceilings.

  • PDF

비내력 천장구조 내화성능평가에 대한 실험적 연구 (An Experimental Study on Fire Resistance Performance Test of Non-loadbearing Ceiling Systems)

  • 최동호;김대회;박수영
    • 한국화재소방학회논문지
    • /
    • 제25권4호
    • /
    • pp.22-27
    • /
    • 2011
  • 건축물의 바닥 하부에 설치되는 비내력 천장이 일정 시간의 내화성능을 확보할 경우 바닥 및 보에 요구되는 내화성능의 감소가 가능하다. 이에 따라 건물시공시 이들 부재에 시공되는 내화피복 절감 및 충전구조 시공 완화 등으로 인하여 공간 구획의 활용성이 증가하여 비교적 경량으로 대규모 공간에 대한 시공이 가능하게 되어 건물 시공 유지관리의 편의성 확보, 공사기간의 단축 및 비용절감과 같은 경제적인 건축생산이 가능하게 된다. 외국에서는 보 바닥 및 천장재를 하나의 복합 시스템으로 구성하여 내화구조로 시공하거나 천장자체의 내화성능을 확보하는 경우가 있으나 국내에서는 이에 대한 연구가 진행되지 않아 건축물의 고층 경량화에 따른 경제적인 효율성을 확보하지 못하고 있는 실정이다. 따라서 국내 건축물에 적용 가능한 내화성능을 확보한 표준화된 비내력 내화천장구조의 개발이 필요하며, 이에 본 연구에서는 현재 일반적인 비내력 천장구조의 내화성능을 평가하여 향후 비내력 내화천장구조의 개발을 위한 기초자료를 제시하였다.

매단 천장의 실간 공기전달음 차단성능 측정방법의 KS규격화 방안 (Korean Standard Draft of the Laboratory Method of Measuring the Airborne Sound Insulation of a Suspended Ceiling)

  • Yang, Kwan-seop;Lee, Keun-hee;Kim, Sun-woo
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.393.1-393
    • /
    • 2002
  • Offices and other multipurpose buildings commonly have suspended ceilings installed over room dividing wall. But Korean Standards don't include any code on test methods and test facility of the suspended ceiling system. Therefore, test methods and test facility from ISO and ASTM have been used for evaluating sound performance in domestic so far. In this study, Korean Standards draft on test methods and test facility of suspended ceiling system and materials is proposed on the basis of ISO and ASTM.

  • PDF

Performance evaluation of suspended ceiling systems using shake table test

  • Ozcelik, Ozgur;Misir, Ibrahim S.;Saridogan, Serhan
    • Structural Engineering and Mechanics
    • /
    • 제58권1호
    • /
    • pp.121-142
    • /
    • 2016
  • The national standard being used in Turkey for suspended ceiling systems (SCS) regulates material and dimensional properties but does not contain regulations regarding installation instructions which cause substandard applications of SCSs in practice. The lack of installation instructions would potentially affect the dynamic performance of these systems. Also, the vast majority of these systems are manufactured using substandard low-quality materials, and this will inevitably increase SCS related damages during earthquakes. The experimental work presented here focuses on the issue of dynamic performance of SCSs with different types of carrier systems (lay-on and clip-in systems), different weight conditions, and material-workmanship qualities. Moreover, the effects of auxiliary fastening elements, so called seismic perimeter clips, in improving the dynamic performance of SCSs were experimentally investigated. Results show that clip-in ceiling system performs better than lay-on system regardless of material and workmanship qualities. On the other hand, the quality aspect becomes the most important parameter in affecting the dynamic performance of lay-on type systems as opposed to tile weights and usage of perimeter clips. When high quality system is used, tile weight does not change the performance of lay-on system, however in poor quality system, tile weight becomes an important factor where heavier tiles considerably decrease the performance level. Perimeter clips marginally increase the dynamic performance of lay-on ceiling system, but it has no effect on the clip-in ceiling system under the shaking levels considered.

비내진 상세를 갖는 금속마감패널 천장시스템의 진동대 실험을 통한 내진성능평가 (Seismic Performance Evaluation of Non-seismic T-bar type Steel-Panel Suspended Ceiling using Shaking Table Test)

  • 이재섭;인성우;정담이;이두용;이상현;조봉호
    • 대한건축학회논문집:구조계
    • /
    • 제35권10호
    • /
    • pp.171-180
    • /
    • 2019
  • In Korea, the seismic design of non-structural elements was interested by Earthquake of the 2016 Gyeong-ju and 2017 Po-hang. Among the non-structural elements, the ceiling system with steel panel used in Po-hang station showed failure examples of non-seismic design ceiling. In this study, the seismic performance of suspended ceiling with steel-panel, such as those used in Po-hang Station, was evaluated by shaking table tests. The shaking table tests were performed in accordance with the ICC-ES AC156 standard with floor acceleration being applied horizontally in one direction using a $3.3{\times}3.3m^2$ frame. The ceiling system consists of steel-panels, carrying channels, main and cross T-bars, and anti-falling clips. The anti-falling clip prevents the steel panel falling completely. The shaking table test confirmed that the damage at the previous stage had a direct impact on the damage state at the next stage. Through the shaking table test, the damage state of the T-bar type steel-panel suspended ceiling system was defined.

천장속 공간을 공유하는 매단 천장의 실간 공기전달음 차단성능 측정방법의 KS규격화 방안 (Korean Standard Draft of the Laboratory Method of Measuring the Airborne Sound Insulation of a Suspended Ceiling)

  • 양관섭;이근희;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.956-960
    • /
    • 2002
  • Offices and other multipurpose buildings commonly have suspended ceilings installed over room dividing wall. But Korean Standards don't include any code on test methods and test facility of the suspended ceiling system. Therefore, test methods and test facility from ISO and ASTM have been used for evaluating sound performance in domestic so fu. In this study, Korean Standards draft on test methods and test facility of suspended ceiling system and materials is proposed on the basis of ISO and ASTM.

  • PDF

한국어 대용량발화말뭉치의 단모음분석 (Monophthong Analysis on a Large-scale Speech Corpus of Read-Style Korean)

  • 윤태진;강윤정
    • 말소리와 음성과학
    • /
    • 제6권3호
    • /
    • pp.139-145
    • /
    • 2014
  • The paper describes methods of conducting vowel analysis from a large-scale corpus with the aids of forced alignment and optimal formant ceiling methods. 'Read Style Corpus of Standard Korean' is used for building the forced alignment system and a subset of the corpus for the processing and extraction of features for vowel analysis based on optimal formant ceiling. The results of the vowel analysis are reliable and comparable to the results obtained using traditional analytical methods. The findings indicate that the methods adopted for the analysis can be extended and be used for more fine-grained analysis without time-consuming manual labeling without losing accuracy and reliability.

Analysis on the Age of Air and the Air Change Effectiveness of the Personal Environmental Module System in Intelligent Buildings

  • Cho, Dongwoo
    • Architectural research
    • /
    • 제1권1호
    • /
    • pp.47-53
    • /
    • 1999
  • An interesting of desktop air-conditioning system is the Personal Environmental Module(PEM) System. The PEM system allows the occupant to choose the desired temperature, air volume and direction of the discharged air. In this study, the measurements on the age of air and the air change effectiveness, using the tracer gas method, are carried out to analyze the ventilation performance for provision of fresh air near the breathing zone by the PEM. The relations between the PEM for optimal control and other factors related to indoor air quality, and the ventilation for the PEM are examined. Also, three different supply diffuser types(desktop, floor and ceiling) are compared in view of their ability to distribute supply air to the workstation breathing zone. The desktop diffuser type could deliver air directly to the occupants breathing zone with a high degree of effectiveness. The minimum local age of air was measured in the breathing zone, which is directly supplied with air from the PEM diffusers, and the measured local air change effectiveness of the desktop diffuser in the breathing zone was about 1.13 to 1.23 times greater than that of the ceiling and floor diffusers. When the minimum outside air change rate as specified using ASHRAE Standard 62R is supplied with a desktop diffuser type, the volume of outside air can be reduced 13 to 23%, resulting in a commensurate in ventilation energy use.

  • PDF

공조취출방식에 따른 공기의 나이 및 환기효율 비교 (Comparison of age of air and air change effectiveness between supply diffuser types)

  • 조동우
    • 설비공학논문집
    • /
    • 제11권1호
    • /
    • pp.117-124
    • /
    • 1999
  • In this study, three different supply diffuser types(desktop, floor and ceiling) are compared in view of their ability to distribute supply air to the workstation breathing zone. The measurements on the age of air and the air change effectiveness using the tracer gas method are carried out to analyze the ventilation performance for provision of fresh air between the diffusers. The desktop diffuser type could deliver air directly to the occupants breathing zone with a high degree of effectiveness. The measured local air change effectiveness of the desktop diffuser in the breathing zone was usually 1.13 to 1.23 times greater than that of ceiling and floor diffusers. When the minimum outside air change rate as specified using ASHRAE Standard 62R is supplied with a desktop diffuser type, the volume of outside air can be reduced 13 to 23%, resulting in a commensurate in ventilation energy use.

  • PDF

CFD 툴을 활용한 패키지형 수소충전시스템의 안전성 향상 연구 (A Study on the Safety Improvement by CFD Analysis for Packaged Type Hydrogen Refueling System)

  • 황순일;강승규;허윤실
    • 한국수소및신에너지학회논문집
    • /
    • 제30권3호
    • /
    • pp.243-250
    • /
    • 2019
  • In this study, to ensure the safety of the packaged hydrogen refueling system, the improvement plan was derived by using 3-dimensional CFD program (FLACS). We also confirmed the effectiveness of risk reduction and the suitability of safety standard. By ventilation performance evaluation according to the position of the vent, it demonstrated that the vent should be installed at the ceiling to safely ventilate without stagnation of the leaked gas. In case of ventilation system according to KGS standard, risk situation could be resolved after about 5 minutes in the worst leaked condition. The result showed that jet fire and explosion inside the packaged system could affect the surrounding facilities. This proves that the standard for installing flame detectors, emergency shut down system and protection wall is appropriate.