• Title/Summary/Keyword: Standard Test Specification

Search Result 220, Processing Time 0.033 seconds

Development of Standard Test Specification for Hiking Stick (등산스틱 시험규격 개발 연구)

  • Kil, S.K.;Kim, J.H.;Kim, T.W.;Lee, S.C.;Hwang, J.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.9 no.4
    • /
    • pp.309-317
    • /
    • 2015
  • In this paper, we proposed the standard test specification for safety and function of hiking stick for the elderly. We have concluded nine factors representing specification of hiking stick through analysis of hiking patents and research papers, products survey of business market, case studies for damaged hiking stick and expert surveys. To test the factors, we designed three different kinds of apparatus to examine twist resistance, stick and tip durability and stick straightness. The sample of hiking sticks purchased from market based on Naver sales ranking top to fifteenth. As a result, we concluded six-standard test specification based on eccentric load, adjustable parts load, hand strap load, basket load, tip load and pull load of hiking stick.

  • PDF

A Study on the Automated Compliance Test System for the LSD Protocol Providing the Digital Library Lending Model

  • Kim, Tae-Hyun;Yoon, Hee-Don;Kang, Ho-Gap;Cho, Seung-Hwan
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.4
    • /
    • pp.51-58
    • /
    • 2017
  • Research on the Development of EPUB SCP(Secure Content Protection) Technical Specification and International Standardization has been carried out as a R&D project granted by the Korea Copyright Commission since 2014. The research aims to build a standard framework for the EPUB DRM(Digital Rights Management) based on the Readium LCP(Licensed Content Protection) and KS EPUB DRM specifications, to develop element technologies for the framework, and to standardize it as an IDPF(International Digital Publishing Forum) industrial standard. One of the essential features of the EPUB DRM developed though this study is to support the lending model of the digital library. This paper introduces LSD(License Status Document) specification which is a DRM license management protocol for the digital library lending process, and also represents a model which can automatically test the implemented entities of the LSD specification, test scenarios and test materials.

Implementation of Java/RTI Level One Test Procedures (Java/RTI를 위한 Level One Test Procedures 구현)

  • 이정욱;김용주;김영찬
    • Journal of the Korea Society for Simulation
    • /
    • v.12 no.4
    • /
    • pp.41-50
    • /
    • 2003
  • HLA (High Level Architecture) is the object, time, and interface standard that proposed for distribution simulation in the US Department of Defense. The HLA is defined by three components: Rules, the HLA Interface Specification, and the Object Model Template (OMT). The RTI (Run-Time Infrastructure) software implements the interface specification. It provides services to simulation applications. To test whether a RTI software is suitable for the standard and all service was implemented is performed through two phases of processes proposed by DMSO. In this paper, we implement Level One Test Procedures of DMSO and apply to NetCust's RTI software. The experimental results are discussed.

  • PDF

Development for Java/RTI Test Suite (Java/RTI를 위한 Test Suite 개발)

  • 이정욱;김용주;김영찬
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.749-752
    • /
    • 2003
  • The HLA is defined by three components: (1) Rules, (2) the HLA Interface Specification, and (3) the Object Model Template(OMT). The RTI(Run-Time Infrastructure) software implements the interface specification. It provides services in a manner that is comparable to the way a distributed operating system provides services to applications. A way to test whether is suitable for a standard, and all service was implemented is tested through two phases of processes to verify the RTI which proposed in DMSO. In this paper, we discuss Level One Test Procedures and a method. Confirms whether RTI was implemented in Interface Specification according to Level One Test Procedures appropriately through a test. Develops Test Suite for every each step to test whether a correct command and the expected results are occur.

  • PDF

A Study on the Automated Compatibility Standard Test System for eBook DRM (전자책 DRM을 위한 자동화된 표준정합성 검사 시스템에 관한 연구)

  • Kim, Tae-Hyun;Kang, Ho-Gap;Ahn, Chang-Ju;Cho, Seong-Hwan
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.2
    • /
    • pp.127-136
    • /
    • 2013
  • The study of the compatibility of EPUB DRM, granted by the Korea Copyright Commission, as a CT R & D project (Project Title: The Development of the standard reference software technology for International Standard EPUB-based eBook DRM) developed standards such as profile standards for encryption digital signature and authentication certificates and standards for technical terms of rights information. In 2012, these four standards have been established as the Korean Industrial Standards under the names of 'Encryption specification for EPUB DRM,' 'the Digital signature specification for EPUB DRM,' 'the Certificate specification for EPUB DRM,' and 'Definitions of Right Terms for EPUB DRM' through the ODPF(Open Digital Standardization Forum) and the TTA(Telecommunications Technology Association). The research project also proposed standards of ebook DRM license protocols in order for the four standards to practically apply to ebook DRM compatibility. It is necessary for technology standards to require a compatibility standard test process for testing whether implementations which were developed on the basis of the standard specification, comply with standards. This study suggests an automated compatible standard test method and a test model under the ebook DRM standard technical specification.

A study on case analysis for loading capacity standard establishment of bi-directional pile load test (BD PLT) (양방향말뚝재하시험의 재하용량 기준 설정을 위한 사례분석 연구)

  • Choi, Yong-Kyu;Seo, Jeong-Hae;Kim, Sang-Il
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.377-384
    • /
    • 2008
  • In the bi-directional pile load test (BD PLT) for pile load test of Mega foundation, loading capacity specification were not specified exactly. Therefore there are so many confusions and variations of maximum 2 times in loading capacity are come out. In this study, specifications of bi-directional pile load test (BD PLT) were considered. Based on cases of the bi-directional pile load test performed in domestic areas, maximum equivalent test load, test load increasing ratio and sufficiency ratio of design load were analyzed. It can be known that the loading capacity specification of bi-directional pile load test must be defined as 1-directional test load that is established as more than 2 times of design load.

  • PDF

Discharge Capacity of PBD and Deep Soft Soil Improvement (PBD의 배수특성과 대심도 지반개량)

  • 구본효
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.10a
    • /
    • pp.585-592
    • /
    • 2002
  • Discharge capacity of PBD is the most important factor of specification items to control any product of PBD. There is no standard specification for the PBD. Because the degree of discharge capacity is related to well resistance, install depth, maximum strain etc in the field. Discharge capacity test of PBD, permeability test of filter are conducted using PBD materials used in Korea. This paper proposes the critical discharge capacity for deep PBD under condition of non well resistance based upon their test and theoretical calculation. It was found that discharge capacity more than about 10 ㎤/sec is enough to undergo designing of deep PBD without well resistance.

  • PDF

Evaluation of Structural Safety of Polyethylene Boats by Drop Test Method (낙하시험에 의한 폴리에틸렌 보트의 구조 안전성 평가)

  • Lee, Sung-Riong;Kang, Gyung-Ju;Cho, Seok-Swoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.5
    • /
    • pp.531-542
    • /
    • 2017
  • The structural safety of small craft, such as steel ships and FRP ships, can be estimated using the measurement test of the hull plate thickness or the longitudinal bending strength test. A polyethylene boat is made using inexpensive HDPE and can be mass produced. The structural safety of a polyethylene boat cannot be guaranteed because a polyethylene boat hull is notspecified in the KR technical rules. The inspection procedure of sailing yachts and pleasure boats and drop test method of ISO standard 12215-5 propose the structural strength required for small crafts as the drop test height. Therefore, in this study, the drop test of a polyethylene boat hull was carried out based on the inspection procedure of a sailing yacht and pleasure boat and the drop test method of ISO standard 12215-5. The drop load was acquired by the drop acceleration ofa boat hull. Structural analysis and safety of a polyethylene boat were performed by the drop load and allowable stress criteria. The calculation results of the hull plate thickness by structural design specification of ISO standard 12215-5 showed that polyethylene boat hull was more than two times thicker than a steel ship hull and the boat hull determined by the inspection procedure of sailing yacht and pleasure boat and drop test method of ISO standard 12215-5 was more than 1.2 times thicker than the boat hull determined by structural design specification of ISO standard 12215-5. Therefore, inspection procedure of sailing yachts and pleasure boats and drop test method of ISO standard 12215-5 was much more conservative than the structural design specification of ISO standard 12215-5 and could be used as the structural design method of a polyethylene boat.

A study on the improvement of The standard specifications for Mock-up Test in the Curtain-wall construction (Curtain-wall공사에 있어서 Mock-up Test 건축공사표준시방서의 개선 방안에 관한 연구)

  • Lee Jin-Man;Kang Jae-Wang;Son Yong-Geun;Kim Chang-Duk
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.491-494
    • /
    • 2003
  • Curtain wall (for the outside wall) must be designed and constructed to resist weather condition of nature like rain. wind and surrounding environment. So, Now days, Mock-up test of curtain wall's total capability is generally used for skycraft building. But, Mock-up test specification in korea is so weak that there are lots of disputation. Also, lacking of clearness in specification causes many trouble in adaptation. Therefore, I would like to consider the problem of Mock-up test specification by inspecting and comparing with other country's works. and I will mention the way of approvement in our specification.

  • PDF

Bodyshell strength analysis for standard EMU (표준전동차 개발을 위한 구조체의 강도해석)

  • 권태수;이호용;이관섭;최성규
    • Proceedings of the KSR Conference
    • /
    • 1998.11a
    • /
    • pp.455-463
    • /
    • 1998
  • The standardization urban transit project has been started by government and the Korean standard electrical railcar has been designed. The bodyshell of standard railcar is made of aluminium alloy. In the present paper, the design of its bodyshell is evaluated in the viewpoint of strength analysis. The loading condition is based on the 'Test Methods of Static Load for Body Structure of Electrical Multiple Unit', standard specification. The bodyshell of Korean standard EMU consist of longitudinal extrusion members which are double-skin structure type. The result in this paper is enough to satisfy strength requirement which is provided by standard specification. The comparison between actual experiment and analysis result will be presented in the next paper.

  • PDF