• Title/Summary/Keyword: Standard Technique

Search Result 2,819, Processing Time 0.032 seconds

A New Key Protection Technique of AES Core against Scan-based Side Channel Attack (스캔 기반 사이드 채널 공격에 대한 새로운 AES 코아 키 보호 기술)

  • Song, Jae-Hoon;Jung, Tae-Jin;Park, Sung-Ju
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.36 no.1
    • /
    • pp.33-39
    • /
    • 2009
  • This paper presents a new secure scan design technique to protect secret key from scan-based side channel attack for an Advanced Encryption Standard(AES) core embedded on an System-on-a-Chip(SoC). Our proposed secure scan design technique can be applied to crypto IF core which is optimized for applications without the IP core modification. The IEEE1149.1 standard is kept, and low area and power consumption overheads and high fault coverage can be achieved compared to the existing methods.

An Efficient Secrete Key Protection Technique of Scan-designed AES Core (스캔 설계된 AES 코아의 효과적인 비밀 키 보호 기술)

  • Song, Jae-Hoon;Jung, Tae-Jin;Jeong, Hye-Ran;Kim, Hwa-Young;Park, Sung-Ju
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.2
    • /
    • pp.77-86
    • /
    • 2010
  • This paper presents an efficient secure scan design technique which is based on a fake key and IEEE 1149.1 instruction to protect secret key from scan-based side channel attack for an Advanced Encryption Standard (AES) core embedded on an System-on-a-Chip (SoC). Our proposed secure scan design technique can be applied to crypto IP core which is optimized for applications without the IP core modification. The IEEE 1149.1 standard is kept, and low area, low power consumption, very robust secret-key protection and high fault coverage can be achieved compared to the existing methods.

Neural Network Compensation Technique for Standard PD-Like Fuzzy Controlled Nonlinear Systems

  • Song, Deok-Hee;Lee, Geun-Hyeong;Jung, Seul
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.8 no.1
    • /
    • pp.68-74
    • /
    • 2008
  • In this paper, a novel neural fuzzy control method is proposed to control nonlinear systems. A standard PD-like fuzzy controller is designed and used as a main controller for the system. Then a neural network controller is added to the reference trajectories to form a neural-fuzzy control structure and used to compensate for nonlinear effects. Two neural-fuzzy control schemes based on two well-known neural network control schemes, the feedback error learning scheme and the reference compensation technique scheme as well as the standard PD-like fuzzy control are studied. Those schemes are tested to control the angle and the position of the inverted pendulum and their performances are compared.

International Standards trend on Hydrogen fuel quality (ISO/TC197/WG12의 수소품질 국제표준화 동향)

  • Cho, Sung-Kook;Cho, Chang-Ae;Lee, Taeck-Hong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.739-743
    • /
    • 2009
  • Japan is leading standards for the hydrogen fuel quality on the PEMFC(Proton Exchange Membrane Fuel Cell) vehicle at ISO/TC197/WG12. However, it has many problems to solve the standard of measurement and the test method. because the standard of measurement which was proposed in Japan is too high to reach the technique for many countries. it might not control standards for the hydrogen fuel quality on the PEMFC vehicle in Korea. So we need to develop the study of standards and the technique of measurement continuously for the International Standards Meeting.

  • PDF

Problems And Improvements of the Standards Code for Plant Design (플랜트 설계를 위한 표준코드의 문제점 및 개선방향)

  • Gu, Bon-Hak;Kim, Tae-Hui
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2006.11a
    • /
    • pp.659-662
    • /
    • 2006
  • Plant industry is very important industry that dominate 70% of standard foreign countries construction acceptance an order woe 2004 years. Technique of plant industry is state that secure part equipment connection detailed design and construction class' competitive power. But, high added value creation among plant industry need technique elevation because available plan, basic design technology is insufficient. Therefore, high added value creation wishes to present problem of standard code and improvement direction for plant design to improve available plan, basic design technology competitive power.

  • PDF

Testing for Self-care Ability Measurement in an Aged Health Center - A Delphi Technique - (일개 노인보건센터에서의 자가관리능력 측정도구 검증 - 델파이기법을 중심으로 -)

  • Kwon, Myung-Soon
    • Research in Community and Public Health Nursing
    • /
    • v.17 no.4
    • /
    • pp.573-582
    • /
    • 2006
  • Purpose: To find out whether the self-care ability measurement used for visiting health care provide an appropriate standard to select service methods using a Delphi survey and to offer basic data that can improve the measurement. Method: A Delphi survey was done with 39 people consisting of theoretical professionals, field managers, and practitioners engaged in visiting health care. Result: It was found that items and weighted points in the currently used self-care ability measurement needed adjustment. Therefore, a modified evaluation standard was presented by domains, items and detailed items. Finally, the self-care ability measurement is composed of 4 domains, 11 items and 19 detailed items. Conclusion: This study is significant in that it presented an evaluation standard applicable directly to business practice by supplementing problems in the existing self-care ability measurement. This study suggests the need to develop various measurements for elderly households based on community.

  • PDF

A Study on the Work Measurement and Application for Korean Manufacturer (한국기업의 작업표준시간 설정 및 운용에 관한 실태연구)

  • 김홍국
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.11 no.18
    • /
    • pp.41-57
    • /
    • 1988
  • This study was carried out to furnish information for the appropriate standard work time measure and applicate system development that help for korean manufacturers. As a research methodology of the study, the questionnaire survey by sampling nine hundreds registerd corporation, was conducted to find the scientific management technique level (for especially standard work time). By crossectionally analyzing the survey results, placed primary emphasis on the study to comparison with employee scale and types of industry classify. The contents of subjective study art as follows; (1) Establish state of standard time(S. T) (2) Mainly technique for establish S. T (3) Institute level and correctness of S. T (4) Practical use of S. T (5) Performance rating and Allowance rate (6) Advantage and disadvantage to application results.

  • PDF

Measurement of Joint Resistance of $(Bi,Pb)_2Sr_2Ca_2Cu_3O_x$/Ag Superconducting Tape by Field decay Technique (자장감쇠법을 이용한 $(Bi,Pb)_2Sr_2Ca_2Cu_3O_x$/Ag 초전도선재의 접합저항 측정)

  • Kim, Jung-Ho;Lee, Seung-Muk;Joo, Jin-Ho
    • Progress in Superconductivity
    • /
    • v.14 no.1
    • /
    • pp.1-10
    • /
    • 2012
  • We fabricated a closed coils by using resistive-joint method and the joint resistance of the coils were estimated by field decay technique in liquid nitrogen. We used the Runge-kutta method for the numerical analysis to calculate the decay properties. The closed coil was wound by $(Bi,Pb)_2Sr_2Ca_2Cu_3O_x$/Ag tape. Both ends the tape were overlapped and soldered to each other. The current was induced in a closed coils by external magnetic flux density. Its decay characteristic was observed by means of measuring the magnetic flux density generated by induced current at the center of the closed coil with hall sensor. The joint resistance was calculated as the ratio of the inductance of the loop to the time constants. The joint resistances were evaluated as a function of critical current of loop, contact length, sweep time, and external magnetic flux density in a contact length of 7 cm. It was observed that joint resistance was dependent on contact length of a closed coil, but independent of critical current, sweep time, and external magnetic flux density. The joint resistance was measured to be higher for a standard four-probe method, compared with that for the field decay technique. This implies that noise of measurement in a standard four-probe method is larger than that of field decay technique. It was estimated that joint resistance was $8.0{\times}10^{-9}{\Omega}$ to $11.4{\times}10^{-9}{\Omega}$ for coils of contact length for 7 cm. It was found that 40Pb/60Sn solder are unsuitable for persistent mode.

Performance Improvement of Robust Speaker Verification According to Various Standard Deviations of a Reference Distribution in Histogram Transformation (히스토그램 변환에서 기준분포의 표준편차 변경에 따른 강인한 화자인증 성능 개선)

  • Kwon, Chul-Hong
    • Phonetics and Speech Sciences
    • /
    • v.2 no.3
    • /
    • pp.127-134
    • /
    • 2010
  • Additive noise and channel mismatch strongly degrade the performance of speaker verification systems, as they distort the features of speech. In this paper a histogram transformation technique is presented to improve the robustness of text-independent speaker verification systems. The technique transforms the features extracted from speech such that their histogram is conformed to a reference distribution. The effect of different standard deviations for the reference distribution is investigated. Experimental results indicate that, in channel mismatched environments, the proposed technique offers significant improvements over existing techniques. We also verify performance improvement of the proposed method using statistics.

  • PDF

Evaluation Technique for Ratio Error of Current Transformer Comparator (전류변성기 비교기의 비오차 평가 기술)

  • Kim, Yoon-Hyoung;Han, Sang-Gil;Jung, Jae-Kap;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.3
    • /
    • pp.291-295
    • /
    • 2008
  • We have developed an evaluation technique for ratio errors of current transformer (CT) comparator by using the precise standard capacitors. By applying this technique for equivalent circuit of CT comparator evaluation system, we can obtain the calculated and measured ratio errors in the CT comparator. Thus we can evaluate ratio errors of CT comparator by comparing the calculated and measured ratio errors. Because this method requires only the standard capacitors, it is simple and easy method to reliability and accuracy maintenance of CT comparator. The method was applied to CT comparator under test with the ratio error ranges of $0{\sim}{\pm}10%$. The ratio error of the CT comparator under test theoretically obtained in this method are consistent with that measured for same CT comparator under test by using wide ratio error CT within an estimated expanded uncertainty (k = 2) in the overall ratio error ranges.