• Title/Summary/Keyword: Standard Operation Time

Search Result 651, Processing Time 0.034 seconds

Cycle-to-Cycle Fluctuations in a Spark Ignition Engine at Low Speed and Load

  • Han, Sung Bin;Hwang, Sung Il
    • Journal of Energy Engineering
    • /
    • v.22 no.2
    • /
    • pp.205-210
    • /
    • 2013
  • Cycle-to-cycle variation has long been recognized as limiting the range of operating conditions of spark ignition engines, in particular, under lean and highly diluted operation conditions. At a part load, some of the cycles tend to knock, while others may have incomplete combustion by the time the exhaust valve opens. An experimental study has been performed in order to evaluate the relative contribution of several relevant parameters on the cyclic variability in spark ignition engines. In general, the stability of engine operation is improved with fuel injector according to the optimal injection timing, but the stability of engine operation at idle is not improved compared with a practical gasoline engine. In this study, we investigated the relationship of the effect of operating conditions for the stability at low speed and load.

Simulation Analysis of the Train Overhaul Maintenance Capacity for Rolling Stock Depot (열차 차량기지의 중정비 검수 용량 시뮬레이션 분석)

  • Jeon, Byoung-Hack;Lee, Won-Young;Jang, Seong-Young;Yoo, Jae-Kyun
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1481-1498
    • /
    • 2007
  • As railroad industry face the new Renaissance era, effective and efficient maintenance methods for rolling stock operation are required with advanced railroad technology. All kinds of railroad systems such as high speed long distance train, metropolitan mass transit and light rail require systematic maintenance technology in order to maintain the safe railroad operation. Simulation models for detailed operations of the sample maintenance center are developed. In this study, standard maintenance procedures, layout, equipments and number of workers of Siheung Metropolitan Railroad Maintenance Rolling Stock Depot are considered. The proposed simulation models are developed using simulation package ARENA. Three simulation analysis using the developed simulation model are done. First, the bottleneck operation is identified. Second, the relationship between maintenance center size, number of workers and cycle time is analyzed. Lastly, the scheduling performances between PERT/CPM and Critical Chain Project Management(CCPM) are compared.

  • PDF

Experimental Waveforms of Single-Pulse Soft-Switching PFC Converter

  • Taniguchi, Katsunori;Koh, Kang-Hoon;Lee, Hyun-woo
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.1002-1007
    • /
    • 2003
  • A new driving circuit for the SPSS (Single-Pulse Soft-Switching) PFC converter is proposed. The switching device of a SPSS converter switches once In every half cycle of an AC commercial power source. Therefore, it can be solved many problems caused by the high frequency operation. The proposed SPSS converter achieves the soft-switching operation and the EMI noise can be reduced. The resonant capacitor voltage supplies to the resonant inductor even if the input AC voltage is the vicinity of zero cross voltage. Then, the power factor and input current waveform can be improved without delay time. A new driving circuit achieves the operation of SPSS converter by one switching drive circuit. The proposed converter can be satisfied the IEC standard sufficiently.

  • PDF

Investigate on the rate of change of CO concentration in a tunnel under changed position of the jet fans by using numerical method (제트 팬 가동위치에 따른 장대터널 내 CO 농도 변화율에 대한 전산해석)

  • Min, Jae-Hong;Kim, Dae-Hyun;Chung, Jin-Taek
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2765-2770
    • /
    • 2008
  • The purpose of tunnel ventilation system for long road tunnels is to keep certain levels of Visibility Index and the concentration of CO. Additional equipments such as jet fans are used in road tunnel to discharge pollutants in the road tunnel. The control algorism of tunnel ventilation system takes the value of sensors as input, and then gives the operation method of jet fans in tunnel as output. Information on the variation of CO concentration in tunnel when jet fans are running is needed to minimize their operation time. Numerical analysis is used in this paper because of the difficulty of conducting experiments under standard condition for ventilation of road tunnel. The concentration of CO has been calculated by using 3-dimensional CFD under transient condition with speed of cars, quantity of air ventilation, and the results for various operation position of jet fans are compared.

  • PDF

Standard Work Process to Reduce a Risk of Track Exchange Work for Railroad (철도 운행선 변경작업의 리스크 저감을 위한 표준작업 프로세스 도출)

  • Yoon, Chang Geun;Park, Su Yeul;Kim, Seok
    • Korean Journal of Construction Engineering and Management
    • /
    • v.22 no.6
    • /
    • pp.131-137
    • /
    • 2021
  • Since many resources are put into the work of changing the railway operation within limited time, it is important to have a specific work plan and safety management. For this reason, the work schedule is shared in advance, and parallel work is being carried out simultaneously by rail system, such as tracks, trolly wires, and signals. However, due to the nature of the transfer work, the work is carried out at night when the railway operation is finished, and many resources are put into the limited area of the operating line, so the risk of safety accidents and failure to change the operating line is recognized as high. Nevertheless, there is still not enough research done in korea regarding the operation line change construction. Therefore, this study is conducted a survey on the track exchange work of railroad for working people, and analyzed the results of the survey. Finally, a standard work process was suggested to reduce the risk of track exchange work.

JPH Timer Display System for Indicating the Standard Outputs JPH (표준 작업량 지시용 JPH 타이머 Display 시스템)

  • Lee Seong-Cheol;Pang Du-Yeol;Choi Kwang-Hun
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.313-314
    • /
    • 2006
  • Indicating product quantity by real time can be benefit both worker and management. Worker can compare real product quantity with its target and can adjust working speed to match with goal. Therefore, so called JPH equipment developed to indicate target quantity of product. As a main processor PIC16F877 was used and FND display were used to indicate current time, elapsed time, JPH value and target amount of product. Values like JPH and starting time, etc. are can easily be set by $4{\times}4$ numeric keypad and display datum likes target amount of product, current time and elapsed time, etc are displayed on FND by RS232 serial transmit. The operation of JPH equipment are tested and verified through long term test and are proved acting properly on working conditions.

  • PDF

Instantaneous frequency extraction in time-varying structures using a maximum gradient method

  • Liu, Jing-liang;Wei, Xiaojun;Qiu, Ren-Hui;Zheng, Jin-Yang;Zhu, Yan-Jie;Laory, Irwanda
    • Smart Structures and Systems
    • /
    • v.22 no.3
    • /
    • pp.359-368
    • /
    • 2018
  • A method is proposed for the identification of instantaneous frequencies (IFs) in time-varying structures. The proposed method combines a maximum gradient algorithm and a smoothing operation. The maximum gradient algorithm is designed to extract the wavelet ridges of response signals. The smoothing operation, based on a polynomial curve fitting algorithm and a threshold method, is employed to reduce the effects of random noises. To verify the effectiveness and accuracy of the proposed method, a numerical example of a signal with two frequency modulated components is investigated and an experimental test on a steel cable with time-varying tensions is also conducted. The results demonstrate that the proposed method can extract IFs from the noisy multi-component signals and practical response signals successfully. In addition, the proposed method can provide a better IF identification results than the standard synchrosqueezing wavelet transform.

Analysis of transmission delay of timecode over SpaceWire network using OMNeT++ (OMNeT++을 이용한 스페이스와이어 네트워크의 타임코드 전송 지연 분석)

  • Ryu, Sang-Moon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.9
    • /
    • pp.2022-2028
    • /
    • 2015
  • SpaceWire is a standard for high-speed links and networks between spacecraft components, which was invented for better, cheaper and faster on-board data handling in spacecraft. The standard defines timecode and its distribution which can be used for time synchronization among the nodes in a SpaceWire network. A timecode output from the time master which provides standard time over a SpaceWire network travels through links and routers to reach every nodes. While traveling, a timecode suffers from transmission delay and jitter which cause some difference in time synchronization among nodes. In this work, a simulator was developed using OMNeT++ to simulate the operation of a SpaceWire network and some analyses were performed on the transmission delay and jitter accompanied with a transmission of a timecode. The result will be used in the near future for the research of a precise time synchronization technique over a SpaceWire network.

A Study on the Performance Criteria of Smoke Control System for Underground Spaces Through Numerical Analysis (수치해석을 통한 지하공간의 제연설비 성능기준 검토)

  • Ahn, Chan-Sol;Chae, Han-Sic;Kim, Hyeung-Youl
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.356-362
    • /
    • 2008
  • This study is intended to evaluate the characteristics of smoke spreading and the appropriateness of evacuation time extended by operation of smoke control system during fire within the underground space of the building structured in compliance with the smoke control system performance criteria from the local fire safety standard in Korea. As a preceding review of this study, the combustibles was categorized and identified their heat release rates. For validate the estimated values, modeling a single underground shop was carried out. And a numerical analysis both in case of smoke control system in operation and the system not in operation was carried out of underground space. From the viewpoint of securing the evacuation time, the results were compared in an attempt to assess the appropriateness of the fire safety criteria.

  • PDF

Wide Voltage Input Receiver with Hysteresis Characteristic to Reduce Input Signal Noise Effect

  • Biswas, Arnab Kumar
    • ETRI Journal
    • /
    • v.35 no.5
    • /
    • pp.797-807
    • /
    • 2013
  • In this paper, an input receiver with a hysteresis characteristic that can work at voltage levels between 0.9 V and 5 V is proposed. The input receiver can be used as a wide voltage range Schmitt trigger also. At the same time, reliable circuit operation is ensured. According to the research findings, this is the first time a wide voltage range Schmitt trigger is being reported. The proposed circuit is compared with previously reported input receivers, and it is shown that the circuit has better noise immunity. The proposed input receiver ends the need for a separate Schmitt trigger and input buffer. The frequency of operation is also higher than that of the previously reported receiver. The circuit is simulated using HSPICE at 0.35-${\mu}m$ standard thin oxide technology. Monte Carlo analysis is conducted at different process conditions, showing that the proposed circuit works well for different process conditions at different voltage levels of operation. A noise impulse of ($V_{CC}/2$) magnitude is added to the input voltage to show that the receiver receives the correct logic level even in the presence of noise. Here, $V_{CC}$ is the fixed voltage supply of 3.3 V.