• Title/Summary/Keyword: Standard Operation Time

Search Result 653, Processing Time 0.027 seconds

Low-complexity Local Illuminance Compensation for Bi-prediction mode (양방향 예측 모드를 위한 저복잡도 LIC 방법 연구)

  • Choi, Han Sol;Byeon, Joo Hyung;Bang, Gun;Sim, Dong Gyu
    • Journal of Broadcast Engineering
    • /
    • v.24 no.3
    • /
    • pp.463-471
    • /
    • 2019
  • This paper proposes a method for reducing the complexity of LIC (Local Illuminance Compensation) for bi-directional inter prediction. The LIC performs local illumination compensation using neighboring reconstruction samples of the current block and the reference block to improve the accuracy of the inter prediction. Since the weight and offset required for local illumination compensation are calculated at both sides of the encoder and decoder using the reconstructed samples, there is an advantage that the coding efficiency is improved without signaling any information. Since the weight and the offset are obtained in the encoding prediction step and the decoding step, encoder and decoder complexity are increased. This paper proposes two methods for low complexity LIC. The first method is a method of applying illumination compensation with offset only in bi-directional prediction, and the second is a method of applying LIC after weighted average step of reference block obtained by bidirectional prediction. To evaluate the performance of the proposed method, BD-rate is compared with BMS-2.0.1 using B, C, and D classes of MPEG standard experimental image under RA (Random Access) condition. Experimental results show that the proposed method reduces the average of 0.29%, 0.23%, 0.04% for Y, U, and V in terms of BD-rate performance compared to BMS-2.0.1 and encoding/decoding time is almost same. Although the BD-rate was lost, the calculation complexity of the LIC was greatly reduced as the multiplication operation was removed and the addition operation was halved in the LIC parameter derivation process.

The opening efficiency of the miniaturized small-scale net for anchovy boat seine to reduce the fleet size (선단축소를 위한 기선권현망 축소형 소형어구의 전개성능)

  • AN, Young-Su;BACK, Young-su;JIN, Song-han;JANG, Choong-Sik;KANG, Myoung-hee;CHA, Bong-jin;CHO, Youn-hyoung;CHA, Ju-hyeng;KIM, Bo-Yeon
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.55 no.1
    • /
    • pp.7-19
    • /
    • 2019
  • This study was conducted in order to improve opening efficiency of the miniaturized small-scale net for anchovy boat seine gear to reduce the fleet size. Field experiment was performed to observe geometry of nets by catcher boats. When the distance between the two ships was 150, 300 and 450 m and the speed of towing nets was 0.6, 0.9, and 1.2 kt, the vertical opening and actual opening of each part of the miniaturized small-scale net was as follows: the front part of the wing net, 6.8-9.5 m, 45-63%; the middle part of the wing net, 16.1-30.7 m, 34-65%; the entrance of the inside wing net, 21.6-41.2 m, 44-84%; the square and bosom, 17.4-34.0 m, 38-75%; the entrance of the body net, 16.5-29.4 m, 36-64%; the entrance of the bag net, 14.5-21.9 m, 70-106%; the flapper, 6.7-7.7 m, 81-83%, and the end of the bag net, 8.6-10.9 m, 64-81%. The tension of towing nets was measured to be 2,734-6,812 kg approximately, which indicates that the fleet can tow nets with 350 hp, the standard engine horse power. The fishing operation time was shortened comparing to existent net with the large-scale buoy attachment operation. It was also possible to operate the ship without fish detecting boat.

High Temperature Application of Iron Removal Chemical Cleaning Solvent in the Secondary Side of Nuclear Steam Generators (증기발생기 2차측 제철화학세정액의 고온적용)

  • Hur, D.H.;Lee, E.H.;Chung, H.S.;Kim, U.C.
    • Nuclear Engineering and Technology
    • /
    • v.26 no.1
    • /
    • pp.140-148
    • /
    • 1994
  • A qualification test was performed for the iron removal chemical cleaning of the secondary side of nuclear steam generators at the selected temperature, 1$25^{\circ}C$, higher than the standard application temperature, 93$^{\circ}C$. The field cleaning condition for a nuclear unit was tested in a bench scale test loop including a SUS 316 stainless steel autoclave with one gallon capacity as a test vessel. The kinetics of sludge dissolution, corrosion of the secondary side materials and change of solvent chemistry were monitored. Test results indicated that more thorough cleaning was accomplished in less than half of the cleaning time required at 93$^{\circ}C$. And the total corrosions of the secondary side materials were found to be less than the values at 93$^{\circ}C$. While the solvent is recirculated and heated by an external chemical cleaning equipment for the conventional 93$^{\circ}C$ process, the secondary side is heated by the lateral heat of the primary coolant without the recirculation of the cleaning solution, and the solvent is mixed by vigorous boiling induced by periodic ventilation for the high temperature process. The requirement that the reactor coolant pumps should be running during the cleaning operation is the major disadvantage of the high temperature process which also should be considered when chemical cleaning is planned for steam generators under operation.

  • PDF

XQuery Query Rewriting for Query Optimization in Distributed Environments (분산 환경에 질의 최적화를 위한 XQuery 질의 재작성)

  • Park, Jong-Hyun;Kang, Ji-Hoon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.14 no.3
    • /
    • pp.1-11
    • /
    • 2009
  • XQuery query proposed by W3C is one of the standard query languages for XML data and is widely accepted by many applications. Therefore the studies for efficient Processing of XQuery query have become a topic of critical importance recently and the optimization of XQuery query is one of new issues in these studies. However, previous researches just focus on the optimization techniques for a specific XML data management system and these optimization techniques can not be used under the any XML data management systems. Also, some previous researches use predefined XML data structure information such as XML schema or DTD for the optimization. In the real situation, however applications do not all refer to the structure information for XML data. Therefore, this paper analyzes only a XQuery query and optimize by using itself of the XQuery query. In this paper, we propose 3 kinds of optimization method that considers the characteristic of XQuery query. First method removes the redundant expressions described in XQuery query second method replaces the processing order of operation and clause in XQuery query and third method rewrites the XQuery query based on FOR clause. In case of third method, we consider FOR clause because generally FOR clause generates a loop in XQuery query and the loop often rises to execution frequency of redundant operation. Through a performance evaluation, we show that the processing time for rewritten queries is less than for original queries. also each method in our XQuery query optimizer can be used separately because the each method is independent.

A Study on the Accuracy of the Loran-C Fix of Korean Chain in Pusan Area (부산지역에서의 Loran-C 한국체인의 측위정도에 관한 연구)

  • 박주삼
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.32 no.4
    • /
    • pp.372-380
    • /
    • 1996
  • The operation of Far East Chain(GRI 5970) of Loran - C system had been stopped on June, 1995, but that of Korean Chain(GRI 9930) of Loran - C system which was jointed with North West Pacific Chain(GRI 8930) and Russia Chain(GRI 7950) by international cooperation, was started on January 1996. In this paper, in order to study the accuracy of Loran - C fix of Korean Chain, the authors examined and analyzed the data of the reciever of Loran - C(LC -90, Furuno) and GPS(AccNav Sport super (TM), Eagle) measured automatically and continually for 2 seconds at interval of 5 minutes from November 22, 1992, to January 20, 1996 at the fixed position of National Fisheries University of Pusan, The results obtained were as follows ; 1)The mean time differences of M-W, M-X, and M-Y pair measured in the base observed position were 12333.09${\mu}$s, 28338.44${\mu}$s, and 42806.01${\mu}$s respectively and the mean standard deviations of that were 0.0121${\mu}$s, 0.0290${\mu}$s, and 0.0327${\mu}$s respectively. The daily and monthly variance forms of time difference at each pair appeared in a similar reappearance. 2)The mean standard deviations of the latitude and longitude by Loran - C were 9.1m and 17.4m in W.X pair, 11.5m and 13.7m in W.Y pair, and 8.1m and 29.3m in X.Y pair respectively, and then the probable radiuses within 95% of each pair were 39.2m, 35.7m, and 60.8m, respectively. Therefore, It is to be desired that W.Y par is selected to improve the accuracy in Pusan area. 3)The mean standard deviations of the latitude and longitude by GPS were 15.4m and 15.0m and the probable radius within 95% was 43.4m. 4)The position errors for GPS and each pair of Loran - C were 16.0m to the South in GPS and 265.2m to the East in W.X pair of Loran - C, 279.5m to the North in W.Y pair of that, and 224.3m to the North-West in X.Y pair of that, so GPS is about 250m higher than Loran - C in accuracy.

  • PDF

A Study on the Establishment Case of Technical Standard for Electronic Record Information Package (전자문서 정보패키지 구축 사례 연구 - '공인전자문서보관소 전자문서 정보패키지 기술규격 개발 연구'를 중심으로-)

  • Kim, Sung-Kyum
    • The Korean Journal of Archival Studies
    • /
    • no.16
    • /
    • pp.97-146
    • /
    • 2007
  • Those days when people used paper to make up and manage all kinds of documents in the process of their jobs are gone now. Today electronic types of documents have replaced paper. Unlike paper documents, electronic ones contribute to the maximum job efficiency with their convenience in production and storage. But they too have some disadvantages; it's difficult to distinguish originals and copies like paper documents; it's not easy to examine if there is a change or damage to the documents; they are also prone to alteration and damage by the external influences in the electronic environment; and electronic documents require enormous amounts of workforce and costs for immediate measures to be taken according to the changes to the S/W and H/W environment. Despite all those weaknesses, however, electronic documents increasingly account for more percentage in the current job environment thanks to their job convenience and efficiency of production costs. Both the government and private sector have made efforts to come up with plans to maximize their advantages and minimize their risks at the same time. One of the methods is the Authorized Retention Center which is described in the study. There are a couple of prerequisites for its smooth operation; they should guarantee the legal validity of electronic documents in the administrative aspects and first secure the reliability and authenticity of electronic documents in the technological aspects. Responding to those needs, the Ministry of Commerce, Industry and Energy and the Korea Institute for Electronic Commerce, which were the two main bodies to drive the Authorized Retention Center project, revised the Electronic Commerce Act and supplemented the provisions to guarantee the legal validity of electronic documents in 2005 and conducted researches on the ways to preserve electronic documents for a long term and secure their reliability, which had been demanded by the users of the center, in 2006. In an attempt to fulfill those goals of the Authorized Retention Center, this study researched technical standard for electronic record information package of the center and applied the ISO 14721 information package model that's the standard for the long-term preservation of digital data. It also suggested a process to produce and manage information package so that there would be the SIP, AIP and DIP metadata features for the production, preservation, and utilization by users points of electronic documents and they could be implemented according to the center's policies. Based on the previous study, the study introduced the flow charts among the production and progress process, application methods and packages of technical standard for electronic record information package at the center and suggested some issues that should be consistently researched in the field of records management based on the results.

The Study for Breast Lymphoscintigraphy of Sentinal Lymph Node in breast cancer (유방암환자 전초림프절의 유방 림프신티그라피에 관한 연구)

  • Kim, Hwa-Gon;Kim, Chang-Soo;Kim, Myung-Jun
    • Journal of radiological science and technology
    • /
    • v.29 no.2
    • /
    • pp.75-81
    • /
    • 2006
  • In the past, most patient of breast cancer suffered side effects due to the useless removement of Axillary Lymph Node, but there is no need to remove it because of the result in this study. The purpose of this study is to save surgery time and side effects after surgical operation for patients with breast cancer by making decisions of operation range for metastasis in first Stenosis Lymph Node using the $^{99m}Tc-Tincolloid$ Scintigraphy and the Micro Probe for radioisotope. As a result of this study, 15 among 20 patients became objects of this study could reduced side effects for operation because there were no axillary lymph node operations. However there is no standard for method of this treatment. It should be standardize where inject point is, how much $^{99m}Tc-Tincolloid$ should be injected(radioactivity value), and the need of massage and Lymph Scintigraphy. Nevertheless I think that this result of study is useful to reduce suffering and side effects from breast cancer and also we should try to do that continuously. The objects for this study were 20 patients diagnosed as breast cancer by Ultrasonography, Mammography & Biopsy. The average of patient age was 45.4 years and its range was between 31 and 71 years. In case of clinical period there were 9 patients of Period I and II patients of Period III. The equipment for this study were $^{99m}Tc-Tincolloid$ describing the Stenosis Lymph Node as a tracer, Micro Probe : Neoprobe 2000(the rest is Gamma Probe) tracing the location, and MS-II Gamma Camera : SIEMENS(the rest is MS-II Gamma Camera) describing the images. There were 3 methods for this study, after selecting one of those methods all 20 patients were performed Stenosis Lymph Node diagnosis & Gamma Probe in operation room. The result was that I imaged all the 20 patients, and seek the Stenosis Lymph Node by using Gamma Probe. Metastasis in Stenosis Lymph Node was 5 and Metastasis in Axillary Lymph Node was 3 between Metastasis in Stenosis Lymph Node cases. Finally 15 patients were also proved that Axillary Lymph Node was Positive and that means there was no Metastasis in Axillary Lymph Node.

  • PDF

Comparison of the Outcomes after Primary Total Hip Arthroplasty Using a Short Stem between the Modified Anterolateral Approach and Direct Anterior Approach with a Standard Operation Table (일반 수술 침대와 짧은 대퇴 주대를 이용한 인공 고관절 전 치환술의 직접 전방 도달법과 변형된 전 측방 도달법에 따른 결과 비교)

  • Park, Myung-Sik;Yoon, Sun-Jung;Choi, Seung-Min;Cho, Hong-Man;Chung, Woochull;Kang, Kyung-Rok
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.3
    • /
    • pp.244-253
    • /
    • 2019
  • Purpose: Total hip arthroplasty was performed using a direct anterior approach (DAA) on an ordinary operation table and a short femoral stem. The clinical radiographic results were evaluated by a comparison with those performed using the modified hardinge (anterolateral approach, ALA) method. Materials and Methods: From January 2013 to November 2015, 102 patients who underwent total hip arthroplasty using DAA (DAA group) and the same number of patients using ALA (ALA group), both performed by a single surgeon, were compared and analyzed retrospectively. The operation time and amounts of bleeding were compared, and the improvement in post-operative pain, ambulatory capacity and functional recovery of the hip joint were checked. The location of insertion of the acetabular cup and femoral stem were evaluated radiologically, and the complications that occurred in the two groups were investigated. Results: The amount of bleeding was significantly smaller in the DAA group (p=0.018). Up to 3 weeks postoperatively, recovery of hip muscle strength was significantly higher in the DAA group (flexion/extension strength p=0.023, abduction strength p=0.031). The Harris hip score was significantly better in the DAA group for up to 3 months (p<0.001) and the Koval score showed significantly better results in the DAA group up to 6 weeks (p≤0.001). The visual analogue scale score improvement was significantly higher in the DAA group by day 7 (p=0.035). The inclination angle (p<0.001) and anteversion angle (p<0.001) of the acetabular cup were located in the safe zone of the DAA group more than in the ALA group, and there was no statistically significant difference in the position of the femur stem and leg length difference. During surgery, two cases of greater trochanter fracture occurred in the DAA group (p=0.155). Conclusion: The DAA performed in the ordinary operation table using a short femoral stem showed post-operative early functional recovery. Because a simple to use fluoroscope was used during surgery with an anatomical position familiar to the surgeon, it is considered to be useful for the insertion of implants into the desired position and for an approach that is useful for the prevention of leg length differences.

A Study on the Estimation of Proper Construction Cost for Road Pavement Maintenance Work (아스팔트포장 유지보수 적정공사비 산정방안 연구)

  • Oh, JaeHun;Song, TaeSeok;An, BangYul
    • Korean Journal of Construction Engineering and Management
    • /
    • v.21 no.6
    • /
    • pp.16-26
    • /
    • 2020
  • Road Pavement Maintenance Work is generated in a variety of different field conditions, and it is difficult to calculate the construction cost because there are no detailed criteria when preparing the estimated construction cost. Unlike new pavements, Road Pavement Maintenance has to be constructed with operating vehicles, and there are many differences in productivity depending on urban areas, limited work hours, night-time, construction area, etc. To compensate for this, the standard for calculation of construction cost provides additional charges for the number of lanes, residential areas, working hours, and night work, but it applied differently depending on construction officials. In this study, construction cost estimation standards that can properly reflect the conditions of the site was investigated for major types of Road Pavement Maintenance work. The site was investigated and analyzed mainly for many construction sites with 'overlay of asphalt after cutting', 'restore surface', 'repair of pavement', and 'recovery of roadway'. The criteria for the application of construction volume separately according to working hours, public places, and land area including extra charges for basic downtown and residential area. The hours of operation were divided into three types(7 hours, 5 hours, 3 hours) excluding movement and preparation time, and each type provided a coefficient for dividing the area of the construction site into five types. The construction cost calculation method based on the construction purpose is site conditions is proposed accordingly, and it is deemed that a plan for the designer to calculate the construction cost has been prepared in consideration of the site conditions.

The Variation of Indoor Air Quality in Nursing Home

  • Ji, Dong-Ha;Choi, Mi-Suk
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.1
    • /
    • pp.117-124
    • /
    • 2020
  • In this paper, we proposed a plan to maintain comfortable indoor air quality in nursing homes by suggesting ways to reduce items temporarily exceeding the reference values through real-time concentration variation analysis of indoor air quality. Five items including PM10, CO2, CO, VOC, and Radon are measured at nursing homes in spring (April) and autumn (September) was carried out and all of the measured items were analyzed to satisfy the criteria set by the Indoor Air Quality Control Act. As a result of the analysis of the real-time concentration change, the concentration of CO2 was close to the reference value based on the number of occupants in the sick room. Due to the disinfectant (alcohol) used to disinfect and the auxiliary tools (adhesive) used in the operation of the program such as making and coloring, it was analyzed to temporarily exceed the standard value in the hall. In conclusion, it is possible to provide pleasant indoor air quality and contribute to securing the nursing home's competitiveness if periodic ventilation, natural disinfectant and eco-friendly product are used in consideration of the thermal environment.