• 제목/요약/키워드: Standard Operation Time

검색결과 653건 처리시간 0.033초

Algorithm of Modified Single-slope A/D Converter with Improved Conversion Time for CMOS Image Sensor System

  • Lee, Sang-Hoon;Kim, Jin-Tae;Shin, Jang-Kyoo;Choi, Pyung
    • 센서학회지
    • /
    • 제24권6호
    • /
    • pp.359-363
    • /
    • 2015
  • This paper proposes an algorithm that reduces the conversion time of a single-slope A/D converter (SSADC) that has n-bit resolution, which typically is limited by conversion time taking up to $2^n$ clock cycles for an operation. To improve this situation, we have researched a novel hybrid-type A/D converter that consists of a pseudo-pipeline A/D converter and a conventional SSADC. The pseudo-pipeline A/D converter, using a single-stage of analog components, determines the most significant bits (MSBs) or upper bits and the conventional SSADC determines the remaining bits. Therefore, the modified SSADC, similar to the hybrid-type A/D converter, is able to significantly reduce the conversion time because the pseudo-pipeline A/D converter, which determines the MSBs (or upper bits), does not rely on a clock. The proposed A/D converter was designed using a $0.35-{\mu}m$ 2-poly 4-metal standard complementary metal oxide semiconductor (CMOS) technology process; additionally, its characteristics were simulated.

다가구 주택의 매트리스 화재 시 차동식 스포트형 감지기의 온도상승 및 동작시간 분석 (Analysis of Temperature Rise and Operation Time of Differential Spot Type Detector in Case of Mattress Fire in Multi-family House)

  • 김서영;공하성
    • 대한안전경영과학회지
    • /
    • 제23권3호
    • /
    • pp.97-102
    • /
    • 2021
  • This study developed a scenario to understand the reaction rate and operational time according to RTI value of rate of rise detector in each type in case of fire mattress. In the results of analyzing the reaction rate and operational time of detector in each scenario, in case when installing a single detector, the elevated temperature per minute was raised to 8℃/min ~ 9℃/min. In case when installing two detectors, it was raised to 9℃/min ~ 10℃/min. In case when installing three detectors, it was raised to 10℃/min. The horizontal distance between detector and mattress was 1.8m~2.5m. Whenever the number of detectors was increased, the horizontal distance was decreased. The operational time of detector was within maximum 540 seconds and minimum 420 seconds. As the research tasks in the future, there should be the researches on the effects of reaction rate of detector on the evacuation in case of fire through the result value of RSET by setting up the latency until the detector operates, and the researches on the safety by understanding if the operational time of detector is suitable for the evaluation standard of performance-centered design.

시스템 복잡도를 반영한 한국형 정비도 예측 방법론 (Korean Maintainability Prediction Methodology Reflecting System Complexity)

  • 권재언;허장욱
    • 한국기계가공학회지
    • /
    • 제20권4호
    • /
    • pp.119-126
    • /
    • 2021
  • During the development of a weapon system, the concept of maintainability is used for quantitatively predicting and analyzing the maintenance time. However, owing to the complexity of a weapon system, the standard maintenance time predicted during the system's development differs significantly from the measured time during the operation of the equipment after the system's development. According to the analysis presented in this paper, the maintenance time can be predicted by considering the system's complexity on the basis of the military specifications, and the procedure can be Part B of Procedure II and Method B of Procedure V. The maintenance work elements affected by the system complexity were identified by the analytic hierarchy process technique, and the system-complexity-reflecting weights of the maintenance work elements were calculated by the Delphi method, which involves expert surveys. Based on MIL-HDBK-470A and MIL-HDBK-472, it is going to present a Korean-style maintainability prediction method that reflects system complexity of weapons systems.

소방차 펌프의 방수성능 기준 재정립을 위한 실증적 연구 (An Empirical Study on the Standard Re-establishment of Water Discharge Performance for the Fire Engine Pump)

  • 민세홍;권용준
    • 한국화재소방학회논문지
    • /
    • 제26권5호
    • /
    • pp.85-91
    • /
    • 2012
  • 소방차에 설치되는 소방펌프에 대한 방수성능 기준이 현장에서 운용하고 있는 실태와 상이한 부분이 있고, 기준이 명확하게 규정되어 있지 않아 소방공무원이 화재현장에서 소방펌프의 사용시간, 최대사용압력, 사용 호스 직경 등 사용 실태를 분석하고, 그 결과를 토대로 소방펌프에 대한 압력별, 호스 직경별 수량별로 다양하게 성능시험을 실시하였다. 현장조사 결과, 소방자동차용 소방펌프의 성능에 관한 인정기준에서 규정하고 있는 규격방수압력(0.85MPa)과 고압방수압력(1.4 MPa)보다 현장에서는 더 높은 압력을 사용하고 있는 것으로 조사되었다. 또한, 펌프의 성능시험 결과는 방수량 및 방수압력 등이 호스의 직경, 관창에 따라 현재 규정하고 있는 인정기준과 매우 상이하게 측정되었으며, 본 연구 결과로 새로운 규격을 제안한다.

편의점에서 판매되는 햄버거와 샌드위치의 유통과정중 품질관리에 관한 연구 (A Study on the Quality Control for the Circulation Steps including Productipn, Transportation, Selling about Hamburger & Sandwich in Convenience Store)

  • 김혜영;송용혜
    • 한국식생활문화학회지
    • /
    • 제11권4호
    • /
    • pp.465-473
    • /
    • 1996
  • The purpose of this study was to evaluate microbiological hazards in the steps of production, transportation and selling of hamburger and sandwich that were marketed in CVS, then to identify methods of control. The reasults are as follows: As the reasult of operation surroundings of manufacturerand reserch of circulation, $4{\sim}6$ hours are needed from manufacturer to CVS. Also transportation car mean temperature was $10^{\circ}C$ which exceeds the standard of $7^{\circ}C$ or below. Hamburger: Critical control points identified were purchasing, cooking, post-preparation, transportation and holding at CVS. As the reasult of microbial analysis following the case of holding methods and reheating at CVS, microbes of cold holding and reheat after cold holding was within standard value. But in the case of room temperature microbes exceeded standard value. Sandwich: Critical control points identified were purchasing, cooking, post-preparation, transportation and holding at CVS. As the reasult of microbial analysis following the case of holding methods and reheating at CVS, total plate counts of cold holding and reheat after cold holding was within standard value. But in the case of room temperature holding after 24 hours total plate counts exceeded standard value. In the case of room temperature holding the number of microbes increased according to the passage of time. As a reasult of food poisoning bacteria, it was negative in every test in sample against V. parahaemolyticus, Salmonella, S. aureus.

  • PDF

교통신호제어시스템 NTCIP 통신규약 적용성 실험 연구 (An Experimental Study on the Application of NTCIP to Korean Traffic Signal Control System)

  • 고광용;정준하;이승환;안계형
    • 대한교통학회지
    • /
    • 제24권5호
    • /
    • pp.19-33
    • /
    • 2006
  • 본 연구에서는 NTCIP통신규약을 국내 실시간 교통신호제어시스템에 적용할 수 있는지를 판단하기 위해 기존 신호제어시스템의 통신방식을 NTCIP에 맞게 수정한 후 운영시험을 실시하였다. 시험연구과정에서 한국형 실시간 신호제어시스템용 관리정보집합(MIB)과 OER규칙의 메시지작성라이브러리, SNMP/SFMP 전송관리프로토콜을 지원하는 센터 관리자 S/W및 지역제어기의 대행자소프트웨어가 신규 개발되었다. 또한 국제표준이 되기 전에 국내 적용을 위해 보완되어야 할 문제점들이 도출되었다. 수정된 시스템은 Trap규칙 등 일부 규격의 문제점을 보완하여 적용한 결과 비교적 잘 동작하였다. NTCIP통신규약으로 수정된 시스템의 가용성시험 결과 2400bps에서는 58%의 패킷이 유실되어 정상적인 운영이 불가능하였으나 4800bps와 9600bps에서는 정상적으로 운영되었다. 또한 실시간 제어능력을 평가하는 주기단위 정보전송능력에서는 4800bps이상이 되어야 적합한 것으로 나타났다. 결론적으로 4800bps 이상의 속도에서 정상적인 실시간제어가 가능한 것으로 나타났다. 또 국내환경에 NTCIP통신규약 적용을 위해서는 통신환경 개선이 필요한 것으로 나타났다.

전기차 충전인프라 및 데이터 연계 분석에 의한 시스템 모델링 및 실증 설계 (Novel System Modeling and Design by using Eclectic Vehicle Charging Infrastructure based on Data-centric Analysis)

  • 김항섭;박호민;정태경;이웅재
    • 인터넷정보학회논문지
    • /
    • 제20권2호
    • /
    • pp.51-59
    • /
    • 2019
  • 본 논문은 최근 각광받고 있는 전기차위주의 많은 실증 사업 중 충전 인프라와 연계된 충전운영시스템 및 전기요금간의 관계를 데이터 연계 분석하였다. 현 시점에서 앞으로 일어날 전기차 충전 인프라에 대한 급속한 수요의 증가로 말미암아 수요치를 예측한다는 의미에서 다가오는 시대를 미리 준비 할 수 있다. 동시에 시스템 모델링을 사이트를 중심으로 실증하고 도식화하는 일이 선행되어야 할 요소이다. 기존의 소규모 시뮬레이션에 의한 모델링과 운영시스템의 설계는 데이터 연계분석을 기반으로 하였다. 본 논문에서는 최종적으로 새로운 시스템 모델링을 구현하여 실제 차량과 이용자를 대상으로 각 지점과 노드별로 시간에 따른 시분할 데이터로 분석하고자 표준 형식으로 도입하였다. 실제 구현된 전기차 충전 인프라와 운영시스템을 대상으로 데이터 연계분석 중심의 효율성을 증명하고자 하였다.

중앙버스전용차로제 실시에 따른 신호운영 방안 연구 (Development of Traffic Signal Operation Strategies On Median Bus Lane)

  • 김균조;김영찬;김진태;정광복
    • 한국ITS학회 논문지
    • /
    • 제5권1호
    • /
    • pp.21-30
    • /
    • 2006
  • 중앙버스전용차로제가 도입됨에 따라 서울의 도로환경은 단기간에 급격하게 변하였으며, 이러한 급격한 변화에 미리 준비되지 못하였던 신호운영상의 문제점들이 경험되고 있다. 장 임계적인 문제점으로 중앙버스전용차로 설치구간 신호교차로에서 일반차량 좌회전 진행을 허용할 경우, 현재 우리나라가 규정하고 있는 차량 4색신호등의 한계로 인한 신호의 비효율적 운영이다. 중앙버스전용차로 설치구간 신호교차로에서 일반차량 좌회전의 현실적 운영방안 마련이 필요하다. 본 연구는 중앙차로전용신호의 도입을 준비하기 위하여 교통관제센터의 신호운영모드별 선행좌회전 및 후행좌회전 운영방안을 검토하고, 각 운영방안 별 Signal Map 구성방안을 점검한다. Signal Map 작성방안을 검토한 결과 기존의 신호제어 장비에 추가의 신호등기신호보드를 활용하는 방법으로 제안된 방법의 현장 적용이 용이한 것으로 확인되었다.

  • PDF

스마트 분전반 제작을 위한 작업 공정도 개발에 관한 연구 (A Study on the Development of a Work Operation Process Chart for Smart Distribution Board Fabrication)

  • 이병설;최충석
    • 한국안전학회지
    • /
    • 제32권3호
    • /
    • pp.15-20
    • /
    • 2017
  • This study presented the strength of the materials and parts for smart distribution board fabrication, and developed a work operation process chart for smart distribution board fabrication. This work operation process chart for smart distribution board fabrication complied with SPS-KEMC regulations, and the applicable range and object are less than 1,000 V and 1,000 Hz for the AC distribution board and less than 1,500 V for the DC distribution board. The power supply is 3 phase 4 wires ($3{\Phi}$ 4W), divided into a single phase circuit and a 3 phase circuit. In addition, the circuit was configured so that the leakage current flowing through the distribution line of the load could be monitored in real time by using the sensor module installed at the rear end of the circuit breaker. Therefore, the administrator can easily find the risk factor of the load since engineer can check the leakage current of each distribution line. In addition, if a leakage current greater than standard value flows, it is possible to generate an alarm against a short circuit and cut off the leakage current. The work operation process chart for the smart distribution board fabrication consists of the following steps: raw and subsidiary materials, sheet metal work, tube making, welding, painting, busbar fabrication, assembly and wiring, product inspection, shipment, etc. Moreover, symbols, ${\Delta}$, ${\nabla}$, ${\bigcirc}$, ${\Rightarrow}$, etc. were used according to the type of work and work progress so that workers can easily understand the progress of the work.

실내화재에서의 열감지기 동작특성 분석 (Analysis on Activation Characteristic of Heat Detectors in a Compartment Fire)

  • Ryu, Hocheol
    • 한국재난정보학회 논문집
    • /
    • 제10권4호
    • /
    • pp.598-608
    • /
    • 2014
  • 소방대상물에서의 경보설비는 실내에 있는 사람들에게 화재를 최초로 알려주는 설비로써, 보다 많은 사람들을 대피시킬 수 있도록 하는 매우 중요한 역할을 한다. 이에 자동화재탐지설비와 같은 경보설비의 최초동작을 빠르게 하기 위한 연구가 필요하다. 이러한 자동화재탐지설비에서 감지기의 동작은 설치위치와 화원의 위치에 따른 영향을 가장 많이 받는다. 그럼에도 불구하고 국내의 감지기 설치 기준은 설치 위치와 화원의 위치는 중시하지 않고 면적과 높이에 따른 화재감지기 설치에 대한 사항만을 규정하고 있다. 따라서 본 연구에서는 실내에 열감지기와 보를 설치하고, 일반적인 화재를 가정하여 5 개소의 화원을 발생시켜 설치된 감지기의 동작시간을 측정하였고, 감지기의 설치위치와 화원의 위치를 고려한 화재실험을 통하여 열감지기의 동작특성을 분석한 것으로 다음과 같은 결론을 얻었다. 열감지기는 벽면에 근접하게 설치된 감지기에서 작동지연현상이 보였으며, 벽면에서 적어도 22cm 이상 이격해서 설치하여야 한다. 화원이 보 외측에 존재할 때 감지기는 보에서 55cm 이격한 거리에서 동작이 가장 빨랐다. 또한 화원에 근접한 감지기와 가장 늦게 동작한 감지기의 동작시간의 차이는 피난거리로 환산하였을 때 최대 115 m 의 피난거리가 확보되는 것으로 나타났다. 이를 통하여 적합한 위치와 적응성을 고려한 감지기의 선택은 피난개시 시간을 최소화시켜 줄 수 있는 것을 확인하였다.