Comparison of Horizontal and Vertical Noise Power Spectrum in Measurements by Using Various Electronic Portal Imaging Devices in Radiation Therapy (방사선치료 시 전자포털 영상장치를 이용한 잡음전력스펙트럼 수평 및 수직 측정비교)

  • Kim, Ki-Won;Choi, Kwan-Woo;Jeong, Hoi-Woun;Jang, Seo-Goo;Kwon, Kyung-Tae;Son, Soon-Yong;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.171-176
    • /
    • 2016
  • The quality assurance (QA) is very important for diagnostic field and radiation therapy field to evaluate the characteristic of devices. The purpose of this study was to compare different NPS methodologies results which are measuring NPS with regard to horizontal and vertical directions by using megavoltage X-ray energies. The NPS evaluation methods were applied to the International Electro-technical Commission standard (IEC 62220-1). The electronic portal imaging devices (EPID) devices such as Siemens BEAMVIEW$^{PLUS}$, Elekta iViewGT and Varian Clinac$^R$ iX aS1000 were used. NPS data were expressed by corresponding each frequency about average of noise value corresponding the each frequency, and NPS were evaluated quantitatively by totaling up the noise values of average frequency which are on horizontal and vertical directions. In NPS results for Elekta iViewGT, NPS of horizontal and vertical by using 4 methods were indicated the difference of 3~5% between horizontal and vertical direction. In the results of Siemens BEAMVIEW$^{PLUS}$ and Varian Clinac$^R$ iX aS1000, the NPS of horizontal and vertical direction were indicated the difference of 15% when averaging the whole values. This study were evaluated the NPS of each devices by totaling up the noise values of average frequency which are on horizontal and vertical directions suggesting the quantitative evaluation method using the data.

Measurement of MDA of Soil Samples Using Unsuppression System and Compton Suppression of Environmental Radioactivity in Processing Technology (환경 방사능 처리기술에서의 Compton suppression 및 Unsuppression system을 이용한 토양시료의 MDA 측정)

  • Kang, Suman;Im, Inchul;Lee, Jaeseung;Jang, Eunsung;Lee, Mihyeon;Kwon, Kyungtae;Kim, Changtae
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.6
    • /
    • pp.293-299
    • /
    • 2014
  • Compton suppression device is a device by using the Compton scattering reaction and suppress the Compton continuum portion of the spectrum, so can be made more clear analysis of gamma ray peak in the Compton continuum region. Measurements above background occurs or, radioactivity counts of radioactivity concentration value of $^{40}K$ nuclides $^{137}Cs$ and natural radioactivity artificial radioactivity detected from the surface soil sample, unwanted non-target analysis and interference peak who dotted line you know the calibration of the measurement energy is allowed to apply the (Compton suppression) non-suppressed spectrum inhibition spectrum and (Compton Unsuppression) the background to the measured value of the activity concentration value of the standard-ray source is detected relative to the peak of By measuring according to the different distances cause $^{137}Cs$, and comparative analysis of the Monte Carlo simulation, in order to obtain a detection capability for efficient, looking at the Compton inhibitor, as the CSF value increases with increase in the distance, more It was found that the background due to Compton continuum of the measured spectrum suppression mode Compton unrestrained mode can know that the Compton suppression many were made, using a $^{137}Cs$ is reduced.

Sex Ratio Determination by Quantitative Real Time PCR using Amelogenin Gene in Porcine Sperm

  • Hwang, You-Jin;Bae, Mun-Sook;Yang, Jae-Hun;Kim, Bo-Kyoung;Kim, Sang-Ok;Lee, Eun-Soo;Choi, Sun-Gyu;Kwon, Ye-Ri;Seo, Min-Hae;Park, Choon-Keun;Kim, Dae-Young
    • Journal of Embryo Transfer
    • /
    • v.24 no.3
    • /
    • pp.225-230
    • /
    • 2009
  • Sex-sorting of sperm is an assisted reproductive technology (ART) used by the livestock industry for the mass production of animals of a desired sex. The standard method for sorting sperm is the detection of DNA content differences between X and Y chromosome-bearing sperm by flow cytometry. However, this method has variable efficiency and therefore requires verification by a second method. We have developed a sex determination method based on quantitative real-time polymerase chain reaction (qPCR) of the porcine amelogenin (AMEL) gene. The AMEL gene is present on both the X and the Y chromosome, but the length and sequence of its noncoding regions differ between the X and Y chromosomes. By measuring the threshold cycle (Ct) of qPCR, we were able to calculate the relative frequency of X chromosome. Two sets of AMEL primers were used in these studies. One set (AME) targeted AMEL gene sequences present in both X and Y chromosome, but produced PCR products of different lengths for each chromosome. The other set (AXR) bound to AMEL gene sequences present on the X chromosome but absent esholthe Y-chromosome. Relative product levels were calculated by normalizing the AXR fluorescence to the AME fluorescence. The AMEL method accurately predicted the sex ratios of boar sperm, demonstrating that it has potential value as a sex determination method.

The Study of Fast X-ray Fluorescence Analysis Using a SSQ Program (SSQ 프로그램을 이용한 빠른 X-선형광분석법 고찰)

  • Park, Yong Joon
    • Analytical Science and Technology
    • /
    • v.11 no.2
    • /
    • pp.112-119
    • /
    • 1998
  • A Siemens SemiQuant (SSQ) 3000 program, a precalibrated 'standardless' analytical program handling up to 90 elements, was evaluated for the fast analysis of various types of reference materials using a wavelength dispersive X-ray spectrometer. Various types of standard reference materials such as metal discs, metal chips, and geological materials in powder form were analysed and it took 23 minutes of measuring time for 75 elements. Measurements of geological reference materials using different sampling methods were carried out and their data were interactively evaluated. The analysis of materials of a known matrix concentration such as stainless steels provided higher precision value compared to totally unknown samples. The analyses of materials prepared as pressed pellets or fused glass beads provided higher precision values compared to the measurement of loose powders with a foil on the sample surface and helium operation, though their sampling procedures were more complicate and took more time. Since very light elements such as boron, carbon, and oxygen have a strong influence on the matrix effects and also on the calculation of effective matrix corrections, the rhodium Compton check was applied to verify the reliability of the defined light element concentrations of light matrix materials and the defined major sample compounds. Failure of defining correct matrix resulted in an unoptimized matrix correction and therefore in the wrong calculation of the element concentration.

  • PDF

Micromachined pH Sensor Using Open Well Structures (개방형 우물 구조를 이용한 마이크로머신형 pH 센서)

  • Kim, Heung-Rak;Kim, Young-Deog;Jeong, Woo-Cheol;Kim, Kwang-Il;Kim, Dong-Su
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.4
    • /
    • pp.347-353
    • /
    • 2002
  • A structure of a glass electrode-type pH sensor for measuring any concentration of $H^+$ in an aqueous solution was embodied with bulk micromachining technology. Two open well structures were formed, and a reference electrode was secured by the Ag/AgCl thin film in the sloped side of the etched structure. A sensitive membrane of an indicator electrode for generating a potential by an exchange reaction to $H^+$ was made with a glass containing Na 20% or more finely so that its thickness might be $100{\mu}m$ or so, and then it was bonded to one pyramidal structure. A liquid junction for a current path was formed by filling an agar in the anisotropically etched part of the Si wafer, which had a size of $50{\mu}m{\times}50{\mu}m$, and then bonded it to the other. After complete fabrication of each part, it was filled with a 2M KCl reference solution and encapsulated the sensor structure with a cold expoxy. The potential value of fabricated pH sensor was about 90mV/pH in the standard pH solutions.

Variation of the Detection Efficiency of a HPGe Detector with the Density of the Sample in the Radioactivity Analysis (방사능 분석에서 밀도에 따른 HPGe 검출기의 검출효율 변화)

  • Seo, Bum-Kyoung;Lee, Kil-Yong;Yoon, Yoon-Yeol;Jung, Ki-Jung;Oh, Won-Zin;Lee, Kune-Woo
    • Analytical Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.59-65
    • /
    • 2005
  • When the low level radioactivity sample is measured, it is required to have many samples. For increase of the sample volume, a scattering and absorbing probability of the emitted gamma-ray in the sample are to be increased. In order to correct the self-absorption effect, the counting efficiency must be calibrated according to a geometrical condition and sample density. But, it is impossible to determine efficiency for counting sample using standard source with the same geometrical condition and density. In this study, the measuring efficiencies were determined with various counting containers and densities. In order to compare the self-absorption effect with the sample density in the various sample container, the variation of the counting efficiency with the densities was investigated by adding NaI, which has high solubility and density. Also, they were compared with Monte Carlo simulation. The self-absorption effect was found to be significant in the low energy region below 0.5 MeV.

A Study on the Global Management Strategy for Product Quality Assurance Based on Brand Power and Country of Origin Effect (글로벌 품질보증 경영 전략에 관한 연구: 브랜드 명성 및 제조 국가 이미지를 중심으로)

  • Hwang, Hee-Joong
    • Journal of Distribution Science
    • /
    • v.11 no.2
    • /
    • pp.23-33
    • /
    • 2013
  • Purpose - Numerous studies have tried to assess the role of a warranty as an explanatory instrument for product quality. While one study argued that manufacturers signal their superior quality to consumers by extending the duration of a warranty, quality is not necessarily related to warranty and a warranty for a short duration is a sign of high product quality. However, there are limitations to measuring product quality in terms of a single variable such as a warranty. Some other studies have evaluated the influence of brand power or value and price on the supposed quality of a product while the influence of warranty was found to be insignificant. Research design, data, methodology - The study analyzes the influence of brand power and the country of origin effect on consumers' perception of product quality in line with warranty and establishes a priority strategy. Especially, consumer experience has a significant influence on state of the art technology products like applied home electronics as these goods are generally quite expensive and consumers expend significant energy in purchasing them, so the associated warranty and brand can have a critical role in the decision making process. The price of the product was excluded in this discussion as it continually varies with the market share of the product. Results - The results of the analysis are as follows: First, each of the factors such as the standard of the warranty, brand power, and country of origin effect influences the degree of satisfaction of an individual. Second, the factors brand power and quality of the warranty interact both complementarily and synergistically at a time, depending on the brand power. As brand power is more significant, the degree of satisfaction is greater in case of products with low quality warranty compared to those with high quality warranty. Third, the brand power and country of origin effect present a complementary interaction. Fourth, the country of origin effect and quality of a warranty interact synergistically. Conclusions - Thus, the higher the quality of warranty, greater is the increment in the degree of satisfaction. The comprehensive study on the effect of the country of origin on the purchase decision process and the degree of satisfaction compared to the other elements shows that in case of Japanese and Korean markets the brand power of a company is desirable in sustaining the quality of warranty to the industrial average. Also, there is no significant improvement in the perceived quality of the product when the quality of the warranty is lowered. Therefore, the warranty effect diminishes when the value of the brand is known, while it perishes when both the brand power and the country of origin effect are strong enough.

  • PDF

Measuring the Professional Development Needs for Technical and Vocational Education and Training Staff in Nepal: A Look at Teachers' Perceptions (네팔 직업기술교육훈련 교사들의 교육훈련 프로그램 요구조사)

  • Lim, Jin Ho;Kim, Dongwook
    • Journal of Practical Engineering Education
    • /
    • v.12 no.1
    • /
    • pp.163-176
    • /
    • 2020
  • Promoting job growth and quality has been central to developing countries to reduce poverty for decades. In this regard, Nepal is not unique in its need to develop effective TVET programme as it is considered showing positive association with workforce development and productivity. While the copious academic literature has highlighted upon staff training programme in general education, it encounters lack of adequate attention in the field of TVET education. The purpose of the study is to identity and prioritise the professional development needs for the teachers of TVET sector in Nepal. A sample(N=317) of Nepalese teachers from seven provinces were asked to answer the scale. The Borich needs assessment model was employed to assess the perceived level of importance and present preferred training modules among 29 teaching subjects. Moreover, a quadrant analysis using 2×2 matrix was used as a diagnostic tool to denote overriding training topics. The result shows that following competence skills constructs were perceived to be in high need of enhancement as well as in existence of discrepancies: 'occupational characteristics of TVET trainer', 'training needs analysis and curriculum development', 'curriculum development based on national competence standard(NCS)', and 'Institution management evaluation'.

Identification of process generating formaldehyde in a furniture manufacturer (특정 가구 제조 공장의 포름알데히드 발생 공정 노출 평가)

  • Yoo, Kye-Mook;Lee, Mi-Young
    • Analytical Science and Technology
    • /
    • v.27 no.5
    • /
    • pp.243-247
    • /
    • 2014
  • Formaldehyde is defined as carcinogen causing leukaemia, lymphoma or nasopharyngeal carcinoma at high level of exposure. Furniture-manufacturing workers can be exposed to formaldehyde, which implies serious impact on health of the workers. The authors carried out ambient monitoring of formaldehyde in the field, and identified the source of formaldehyde generated during the working process by testing the condition in the laboratory settings. After sampling formaldehyde in the air with 2,4-DNPH (2,4-dinitrophenylhydrazine) coated silica gel, we extracted formaldehyde derivative with acetonitrile and analyzed the extract using HPLC with UV detector at 360 nm. Formaldehyde was separated by ACQUITY UPLC BEH $C_{18}$ column at a flow rate of 0.5 mL/min using 45% acetonitrile as mobile phase. The workers were exposed to higher level of formaldehyde than normal air. Formaldehyde up to 0.31 ppm was detected in the process of veneer attachment, which exceeded 0.3 ppm, the ceiling value of ACGIH standard. The laboratory test of measuring formaldehyde generated from the glue and veneer used in the attachment process resulted in more formaldehyde generation as the temperature increased, and more from the veneer. Heating the veneer to $100-150^{\circ}C$ following the real condition of the manufacturing site generated 1.14-2.70 ppm of formaldehyde from the sample, which was 2-5 times higher level than Korean limit of exposure (0.5 ppm). As the workers handling and processing the veneer which was produced by wet process had high possibility to be exposed to formaldehyde, urgent improvement and management of working environment of furniture manufacturer is demanded.

A Study on the Mechanical and Rheological Properties of the Recycled Polyethylene Composites with Ground Waste Tire Powder (재생 폴리에틸렌/폐타이어 분말 복합체의 기계적 특성 및 유변학적 특성에 관한 연구)

  • Kye, H.;Shin, K.;Bang, D.
    • Elastomers and Composites
    • /
    • v.41 no.2
    • /
    • pp.97-107
    • /
    • 2006
  • The recycled polyethylene composites with various ratio of ground waste tire powder were manufactured by using a fully intermeshing co-rotating twin screw extruder for the reuse of waste tire scrap. In this investigation, the ground waste tire powders (GWTP) were blended with virgin HDPE and recycled polyethylene in the weight ratio of 0 to 50 wt.%. Mechanical properties such as tensile strength, elongation at break and impact strength were measured by using ASTM standard. The experimental results for the various composite showed that the tensile strength of composites decreased with increasing GWTP ratio, while elongation at break increased with the amounts of GWTP. On the other hand, the impact strength for the three kinds of composites showed maximum at the 30 wt.% of GWTP and then decreased. Morphology of the fracture surface tends to be rough with increasing waste tire powder content. Rheological properties were investigated by measuring the shear viscosity against shear rates and softening temperatures. They showed that melt viscosity of rubber composites in this study subsequently increased with increasing GWTP content as a result of increase of flow resistance against external stress and followed a Power-law behavior.