A Method for Predicting the Color Appearance Values of Textiles Depending on Illumination (광원에 따른 텍스타일의 Color Appearance 수치 예측 방법)

  • Chae, Youngjoo
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.44 no.1
    • /
    • pp.68-83
    • /
    • 2020
  • This study suggests a method to predict the color appearance of textiles that shifts depending on illumination variations. The suggested method allows the calculations of lightness, chroma, and hue appearance values from the spectral reflectance values of the textile and illuminant. The accuracy of the method was evaluated through numerical and statistical comparisons between the predicted and the measured color appearance values of 24 fabric samples under CIE standard illuminant D65. As a result, there were excellent agreements between the two data sets with the error values close to zero. The predicted color appearance values of 24 samples under two illuminating (color temperature-luminance) conditions, 2700 K-100 cd/㎡ and 6500 K-100 cd/㎡, were then compared to prove the significant effect of illumination on the color appearance of textiles. The color appearance values were also compared with spectrophotometrically measured physical color attributes, that is, true colors of the samples. The physical color attributes of samples were unchanged; however, differences in color appearance under different conditions were generally much larger than the suprathreshold color difference tolerances discussed in the color science literature. Finally, the magnitude of the illumination effect depending on the physical color attributes of samples was also analyzed.

A Study on the Actual Conditions of Living Room Lighting in Daegu and Gyeongbuk Districts (대구·경북 지역 거실 조명 실태조사)

  • Jo, Young-Mi;An, Ok-Hee;Kim, Hyun-Jin
    • Journal of the Korean housing association
    • /
    • v.23 no.3
    • /
    • pp.13-20
    • /
    • 2012
  • This research study was conducted to determine the actual conditions of living room lighting in Daegu and Gyeongbuk districts. For this study, 112 households were surveyed. The results of this study are as follows: Firstly, fluorescent light was used as the general illumination of living rooms, and the ratio of not using local sources of illumination was high. Secondly, the standard illuminance was found to be 221. The illuminance was the value that satisfied the activities for togetherness and entertainment, but did not reach the illuminance necessary for other activities, such as reading, make-up, and sewing. In addition, the uniformity of brightness used as a measure of uniformity in examining the results was normal. Thirdly, both the brightness and the satisfaction of lighting in the living room space were indicated to be normal. In addition, in regard to housing lighting, 'stability', and 'brightness of lighting' were indicated as important considerations and 'brightness of lighting', 'shadow' and 'management of lighting' were indicated as problem areas.

A Study on the Design of a Floodlighting Tower with LED Source of Light Considering the Reduction of a Glare (눈부심 저감을 고려한 LED광원 계류장 조명탑 설계에 관한 연구)

  • Kim, Dong-Su;Huh, Chang-Su
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.4
    • /
    • pp.271-275
    • /
    • 2015
  • The floodlighting assists the pilot in taxiing the aircraft into and out of the final parking position and provide lighting suitable for passenger to embark and debark and for personnel to load and unload cargo. It is composed of sodium lamps which is consuming high energy. It needs to develop a dedicated LED lamp to replace the existing lamps. In this paper, We propose a suitable asymmetric angle of LED lamps to avoid a pilot's glare and to meet the standard illumination. For this, we analyze asymmetric angle of sodium lamps which are using in airport and confirm whether the illumination distribution and glare index meet the relating standards by using simulation method. Also, we study the needs of asymmetric characteristics of LED ramp by simulating the LED lamps with and without asymmetric characteristics of ramp respectively. With the simulation result, finally we propose the best asymmetric angle of LED lamp to meet the average illumination standard, and avoid a pilot's glare.

A Study on the Characteristics and Improvement Plans of Illuminance, Color Temperature, and Luminous Sources of Contemporary Korean Protestant Church - Focusing on the Churches Constructed in Seoul Since 2010 - (한국 현대 개신교 예배공간의 조도, 색온도, 광원 특성 및 개선방안에 관한 연구 - 2010년 이후 건축된 서울 지역 교회를 중심으로 -)

  • Jun, Ye-Jin;CHoi, Sang-Hun
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.4
    • /
    • pp.86-93
    • /
    • 2013
  • Illumination in church building has played an important role in making workship space more suitable for divine service. As time has changed, however, the worship space of Protestantism is no longer somber and reverent, but changing into practical and multipurpose space with bright and colorful image. This study investigates intensity of illumination of worship space during day and night respectively and figures out the change of psychological change of congregation in accordance with brightness and color temperature in worship space in order to find out preference and look into the usage and change of illumination in recent Protestantism in compliance with the needs of the time and influence. Then, result value is to be compared to Korean Standard intensity of illumination. Also, the correlation between intensity of illumination and color temperature by Kruithof's curve theory is used to identify the comfortableness of the worship space during day and nigh. And it is a common task of space designers and pastors to map out the worship space in terms of illumination suitable for its own purpose with even more modern and Korean sensibility and to create spiritual space for worshippers by collecting opinions from congregation, the main user of the space. With appropriate usage of illumination in Protestantism worship space, the atmosphere and purpose of worship can be enhanced.

A STUDY ON THE ILLUMINATION OF DENTAL CLINIC (치과 진료실의 조명에 관한 실태 조사연구)

  • Choi Jong-In;Kim Yu-Lee;Dong Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.4
    • /
    • pp.374-382
    • /
    • 2006
  • Purpose: This study was designed to investigate the present conditions of illumination techniques in dental clinics in order to contribute improvement of operating environment. This study also aimed exploring qualitative and quantitative luminous intensity required for color temperature in dental clinic illumination, which was a critical part of esthetic dentistry. Materials and methods: A total of forty-eight local dental clinics were selected for sampling a) luminous intensity, and b) color temperature. The author measured the luminous intensity and the color temperature with lux meter and color meter respectively between 12pm and 2pm. The dental unit chair placed in the general operation positions were kept the distance 60 cm then all dental units were measured three times and averaged. The author measured the luminous intensity and color temperature with both common dental operating light and then without operating light in different office environments. The study was conducted under three conditions: 1 artificial illumination in clear day light 2. artificial illumination in cloudy day light, and 3. artificial illumination alone. Results : The results obtained were as follows. 1. The average luminous intensity in dental clinic lighting was 425 lux which was not sufficient to produce the optimal shade of the patient's teeth. Furthermore, the average luminous intensity even in full operating lighting was 9532 lux which fell short of the required level of 10,000 lux. 2. The average color temperature of all dental clinics surveyed was 5169 K which met the optimal range. However, only 33.3% fell in the correct region between 5,000-5,500 K as 25% were over 5,500 K and 41.6% were below 5,000 K. As a result, 66.7% were under insufficient color temperature conditions. 3. The dental unit chair placed next to a window, hence exposure to natural lighting, had significantly higher luminous intensity and color temperature compared to the dental unit chair which didn't have a window or natural lighting. 4. The data analysis revealed that only 6.3% of the dental clinic were met the standard of the average luminous intensity and color temperature.

A Study of yield method including artificial lighting uniformity ration in interior space (실내공간에서의 인공조면 균제도 산출방법에 대한 일고찰)

  • ;金玹志
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.2
    • /
    • pp.139-139
    • /
    • 1999
  • In this paper, the result of study in artificial lighting uniformity ratio yield method subject to lecture room are reported. It is desirable that the application of equation ① U=Ei/Ex×100 cannot be used to the mean value in place to be effective of light and darkness. And it is desirable that the application of equation ② U=Ei/Ea×100 or equation ③ U=(Ea-Ei)/Ea×100 be used to the mean Value equality illumination conditions. Also, requiring preparation of judgement standard, uniformity ratio equation agree with actual circumstances in this country. It must be considered intensity of illumination and specificity of space in established standard.

Comparison of the Lighting Environment in Study Rooms for Juveniles between the City and the Country

  • Kim, Hyun-Ji;Jeon, Gyeong-Seon;An, Ok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.7
    • /
    • pp.1-7
    • /
    • 2009
  • The research aims at providing data needed for planning the lighting of a study room by comparing the lighting environments of study rooms for urban and rural juveniles. The subject of the research was 300 students in middle schools in Daegu and Checngdo-gun, Gyeongsangbuk-do (Daegu 150 houses and Cheongdo 150 houses), and their study rooms were examined. The following is the result of the research. First, rural students stayed more time in their study room than urban students. The task that rural students (studying) and urban students (studying and using computer) all did in their study room was mainly visual work Second, although the sizes of rural study rooms were bigger than those of urban study rooms, urban study rooms had more light sources than rural study rooms. In the rate that of having a task lighting, the city(87.1[%]) was higher than the country (45.7[%]). However, the rate of using a task lighting was lot high in both the city and the country. Third, the result that compared the average values of illuminations on desk planes was that the average value of the city was 3.4 times higher than that of the country. Also, the average value of the country did not meet the standard illumination of Korean industrial standards (KS). In particular, it did not reach the lowest standard. The result is related with that only 52[%] of students who had a task lighting used it. Finally, the satisfaction of lighting environment in the city was generally higher than the country. Especially, although the country had a low illumination, the user showed a high satisfaction. It indicates that people living in the country need to understand about the needs of illumination.

Improvement of Lighting Control System for Tunnel (터널 조명 제어장치의 성능개선)

  • Eo, Ik-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1964-1966
    • /
    • 2003
  • Lighting in the tunnel makes for safe driving of cars taking into account of change in perception arisen in the sight of drivers of cars entering into and passing tunnel, drivers' mental reaction and unique circumstances of a tunnel. There are many variables to satisfy safe driving in the tunnel. Since tunnels are mostly located in the mountainous area and illumination at the approach part differs largely depending on the surrounding circumstances, a standard different from that of common lighting is applied. An accidentin the tunnel, which involves same danger as in underground, may lead to a large mishap. Therefore, control by sensors inside and outside of tunnel ensures prevention of an accident through control of illumination at the approach part and inside of tunnel. It is very important in the aspect of saving energy since such control is available to reduce depreciation factor resulted from early excessive intensity of illumination.

  • PDF

The Actual State and Evaluation of Artificial Lighting on Coffee Houses Using Study Place around University (학습공간으로 이용되는 대학주변 커피전문점의 조명 실태 및 평가)

  • Choe, Sol-ji;Choi, Yoon-Jung
    • KIEAE Journal
    • /
    • v.11 no.6
    • /
    • pp.53-62
    • /
    • 2011
  • This study aimed at suggesting improvement of lighting environment of the coffee house using study place. To this end, a series of field investigation was conducted in four possible target coffee houses around university. The field measurement included measurement of general illuminance and tabletop illuminance, observing illumination condition, and status of artificial lighting. Also, on-site questionnaire survey was administrated to 80 users of field measurement targets about using characteristics of coffee house and user's subjective response on light environment. The results are summarized as follows: (1) According to questionnaire survey, most of users checked 'learning (study and reading)' in 'purpose of coffee house using', and 'slightly dark' was checked most in each subjective response (brightness on general space and on tabletop at daytime/night); (2) as results of measurements on general illuminance and on tabletop illuminance during daytime, only one coffee house was suitable for standard; (3) as results of measurements on illuminance during night, all target coffee houses were not met the standard; (4) as results of uniformity ratios, almost uniformities of general illuminance were not met the standard except one case. The common problems of lighting environment of coffee house were analyzed as lack of daylight illumination e.g. having low amount of sunshine from skylight, un-uniformity of insolation by floor plan and absence of window blind, and un-uniformity of artificial luminous intensity e.g. lack of the number or brightness of artificial lighting, using the indirect lighting, using only local lighting, and non-uniform arrangement of artificial lighting.

Light Intensity and Spectral Characteristics of Fluorescent Lamps as Artificial Light Source for Close illumination in Transplant Production Factory (식물묘공장의 근접조명용 인공광원으로서 형광등의 광강도 및 분광 특성)

  • 김용현;이종호
    • Journal of Biosystems Engineering
    • /
    • v.23 no.6
    • /
    • pp.591-598
    • /
    • 1998
  • Light intensity and spectral characteristics of different types of fluorescent lamps were tested to investigate their possibility as the artificial lighting sources for the close illumination applied in the transplant production factory. Photosynthetic photon flux densitiy(PPF), illuminance and irradiance for all lamps decreased logarithmically with an increase of the vertical distance from the lighting source. The fluorescent lamp specially designed plant growth (PG lamp) showed a maximum spectral irradiance at the wavelength of 660nm. However, it showed lower irradiance than that of a standard fluorescent lamp at the range of wavelength between 500 and 600nm. On the other hand, PG lamp showed higher PPF and lower illuminance than those of the standard fluorescent lamp. The maximum peak of spectral characteristics for both of the single and twin three-bind fluorescent lamps was shorn at the wavelength of 545m and the next peaks were shown at the wavelength of 610nm and 435nm, respectively. Since the red fluorescent lamp has a narrower peak at the wavelength of 660nm, it may be useful for the supplementary red lighting. For three of standard, single three-band and twin three-band fluorescent lamps, the values of conversion factor for converting illuminance to PPF fell within the narrow range from 76 to 791x/$\mu$molㆍm$^{-2}$ ㆍs$^{-l}$ . However, for PG lamp, it was 29.71x/$\mu$molㆍm$^{-2}$ ㆍs$^{-1}$. Also, the values of conversion factor for converting PPF to irradiance of fluorescent lamp used in this study ranged between 4.85 and 5.34$\mu$molㆍm$^{-2}$ ㆍs$^{-1}$/Wㆍm$^{-2}$ .