• 제목/요약/키워드: Standard Illumination

검색결과 179건 처리시간 0.021초

도시근린공원의 야간조도분포의 특성 (Characteristics of th Distribution of Night Illumination Level at Urban Neighborhood Parks)

  • 최연철;김진선
    • 한국조경학회지
    • /
    • 제28권4호
    • /
    • pp.66-74
    • /
    • 2000
  • The purpose of this study is to research and analyze the distribution of night illumination level at urban neighborhood parks and to show its characteristics. And this is used basic data ensuring safety and satisfying aesthetic and psychological desires of people who use urban neighborhood parks at night. To research and analyze the distribution of illumination level at urban neighborhood parks at night. To research and analyze the distribution of illumination level at urban neighborhood parks, I selected 8 urban neighborhood parks as the subject of research in this study, set the measuring standard of illumination level, and measured the illumination level by the measuring standard. The results of this study are as follows; 1. Currently, total average illumination level of urban neighborhood parks was lower than the minimum standard of illumination level I KS A 3011-1993. 2. Average illumination level of each place in urban neighborhood parks appeared variously from low level to high level. But this was lower than the minimum standard illumination level in KS A3011-1993 like total average illumination level. 3. The higher was total average illumination level of urban neighborhood parks, the more various was brightness of places. Although users' aesthetic and mental desire or behavioral aspect relate with safety cannot be found by only survey and analyses of illumination level, it is judged that first, illumination level of the standard of the lightness should be analyzed to find user's mental states and behaviors in external space at night. Therefore, it is considered that this study, which analyzed characteristics illumination level as basic data, has a significance. The study continuing for other illuminative environmental factors suitable in the place is required because the brightness of places may not be measured by only illumination level. And the proper illumination level in outdoor places should be showed in considering psychological and behavioral aspects of human as people may have their own sense of brightness.

  • PDF

업무공간의 조명 환경 실태 조사 연구 (A Study on the Status of Illumination Environment in Workplaces)

  • 최한희;하미경
    • 한국실내디자인학회논문집
    • /
    • 제13권6호
    • /
    • pp.167-174
    • /
    • 2004
  • The purpose of this study is to examinethe present illumination conditions in office environment and to suggest an efficient illumination plan in office planning process. Illumination conditions in work environment were surveyed in 6 offices to investigate whether the present illumination conditions were appropriate to the work type. The results of this study are as follows: Most of the general Illuminance level in the area of work were all at an adequate level, except one. The average Illuminance level in the all meeting rooms were met for the standard. Illuminance in the all reception area were extremely over the standard, The illuminations of this area were rather designed according to the image of the company than the standard. As for the illumination method in the area of general work, four offices used a general lighting by a direct lighting type, while two offices used a general lighting and a task lighting at the same time. This survey suggested that first, each company should consider illumination plan in the building planning process, second, illumination plan considering the type of places is needed, and third, illumination environment may be differentiated according to the work type. In conclusion, efficient illumination environment should be considered in office building planning process, especially In terms of illumination materials and methods.

고령자의 주택조명환경 실태조사 (Actual Conditions on the Illumination Environment of the Elderly House)

  • 최미향;김현지;안옥희
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.235-238
    • /
    • 2009
  • This research surveys actual conditions on lighting environments of the elderly's houses. from the results of survey on actual conditions of lighting in the elderly's houses, they don't meet standard of illumination suggested by KS A 3011, and, standard of ovarall illumination is satisfied in general, but illumination in a side of work or other activities is lower than the standard and it has failed to suggest standard that is considering user's characteristics, visual characteristics going with their ages and so forth, it is thought to urgently prepare standard which considers visual characteristics of the elderly and their ages.

  • PDF

주택의 조명과 거주자의 면경착용 실태조사연구 (A Study on the Illumination of Household and Research on the Actual Conditions of Wearing Spectacles in Dwellers)

  • 석호작;남철현
    • 한국환경보건학회지
    • /
    • 제17권2호
    • /
    • pp.54-66
    • /
    • 1991
  • As a result of measuring illumination and making up a question at home visit directly by investigator who trained over twenty days period from October 4 to 24, 1990, in order to render help which illumination problem against house, society against eyes or framing of health instruction potgram by seizing natural lighting actual conditions of house and actual conditions of wearing spectacles and by investigating interrelationship, I can summarize as follows. 1) In property of investigation subject, woman 66.9%, In an age, the twenties was largest of 27.4%, the forties was 20.2%, the fifties was 18.6%, the thirties was 17.4%. In academic career, those of upper secondary school grauates was largest of 28.6%, those who possess university career was 25.9%, those who middle school career was 20.9%, decoding of Korean alphabet was 2%. 2) By a residence area, a big city was 43.3%, farming and fishing villages were 20.3%, the rest was a small town and the administrative office of town, township. In positon of house, the middle area was 43.6%, resident of suburb area was 38.0%. In form of house, a Korean-style house was 40.8%, a western-style house was 34.8%, an apartment house was 11.0%. In the a standard of living, the middle classes 77.2%, the lower classes were 15.3%. In residential house unit of area, from 21 to 30 unit of area was largest of 31.5%, from 10 to 20 unit of area was 19.9%, from 31 to 40 was 18.7%. 3) The wearing spectacles rate of study user was 44.1%. By the area, those who wearing spectacles was more than a half of 50.8% in the resident of big city area. As passing from the farm area to the city, that is being resident of big city was high wearing spectacles rate. In position of house, as being residence in central street showed high wearing spectacles rate. (central street was 51.5%, the middle area was 44.5% and the suburb area was 40.1%.) It seemed similarity difference a variable by position of house from wearing spectacles in standard of 1%. By form of house, wearing spectacles rate those who resident in apartment house was 49.5%, that rate those who resident in a western-style house was high of 49.0%, that rate those who resident in a Korean-style house was the lowest 39.0%. By social position of resident in room, in students case who study showed very high, as university students were very high of 62.3% idn wearing spectacles rate, middle and high school students 'were 50.0%, members of society were 47.6%, workers 20.3%. It seemed similarity difference from academic career in standard of 1%. By an age, the thirties was high of 54.1% in wearing spectacles rate, the twenties was 43.2%, the teenage was the lowest of 11.8%. 4) In illumination of study, over 200Lux was high of 40.1%. but below 99Lux which inappropriate illumination to see the books was 32.4%. Average by area, below 99Lux was 22.7% and over 400Lux was 50.0% in case of wooden floor. As examine by area, below 99Lux was high of 27.0% a case of wooden floor in the big city area, it was not good in illumination passing from the farm area(15.0%) to the city(19.0%). Average illlumination by area of the main living room below 99Lux was high of 37.5%, less than 200Lux was 58.5% of whole. In general, illumination of the main livingroom was inappropriate. By area, the big city was 32.5% below 99Lux, the middle and small city area were 33.8%, town and township area were 45.0%, farming and fishing area were 42.8%. By area, in the big city, illumination of study was 52.5% over 200Lux and 28.9% below 99Lux. In case of the middle and small city, study user of below 99Lux was 38.8% and over 200Lux was 46.9%. In case of the seat of town township, below 99Lux was 34.1% and over 200Lux was 39.7%. In case of farming and fishing area, illumination of study was 33.4% below 99Lux and 48.4% over 200Lux. It tends to high rate of inappropriate illumination. 5) By position of house, in case of wooden floor, less than 100Lux was 24.5% in central street. It was bad illumination than others position of house. In case of the main livingroom, less than 100Lux was 40.4% in the suburb area. It was bad iliumnation than others position of house. In case of study, less than 100Lux was 35.4% in the middle area, it was worse in illumination. In case of the main living room, is seemed similarity difference in standard of 1%. 6) By form of house, in case of wooden floor, illumination of less than 100Lux was 23.8% in a western-style house, it was bad illumination than others form of house. In case of the main livingroom, illumination of less than 100Lux was 47.4% in a Korean-style house, it was remarkably bad illumination than others form of house. In case of study, a Korean-style house was 38.8%, it was very bad illumination than others form of house. In case of the main livingroom and study, it seemed similatrity difference each as P < 0.01 and P < 0.05 in standard of 1%. 7) The wearing spectacles rate of those who use room of illumination over 400Lux was 40.7%, and that of those who use room of illumination less than 100Lux was 28.1%. It seemed similarity differecce in standard of 1%. 8) In period of wearing spectacles, 21.3% of total investigator-highest-was from before five years, 8.6% was from before three years. Among those who use of illumintion less than 99Lux, 34.0% began to wear spectacles from before two years 31.7% was from before five years, 30.3% was from before four years. It seemed similarity difference from period of wearing spectacles by illumination in standard of 1 %. 9) Among cause which sight grow worse, the first was that it was each 33.2% and 27.4% in response rate because watch TV nearly to wearing spectacles person and non-wearing person. The second was that a lot of seeing books was 25.3% in wearing spectacles person and response rate for dark illumination was 7.4% in nonwearing spectacles person. It seemed similarity difference in standard of 1%. (P < 0.01). 10) In experience which take medicine good for eyes, it was 50.1% in wearing spectacles person and 8.5% in non-wearing spectacles person. It seemed similarity difference in standard of 1%(P < 0.01). As we have seen above, inappropriate illumination can be a cause of wearing spectacles. Nevertheless, actually, is realities to indifferent against illumination of house. So it must learn knowledge about health obstacle of illumination through society instruction and school eduction against students as well as general residents. In case that natural lighting is inappropriate structural of house, we must be able to maintain appropriate illumination through artificial illumination. And so eyes which is core of human life have to be protected, related the authorities, related group, and all health medical personnel will organically cooperate with and make efforts.

  • PDF

인간공학 기준에 의한 차세대형 주제어실 조명설계 및 조도 휘도 분석- 중국 광동 Ling Ao Phase II NPP MCR 환경디자인을 중심으로- (A Study on Lighting Design and Illumination and Luminance of in Advanced type Control Room by the Standard of Ergonomics - Focused on Ling Ao Phase II NPP MCR Environmental Design in Guangdong, China-)

  • 백승경;이승훈
    • 대한인간공학회지
    • /
    • 제27권2호
    • /
    • pp.73-82
    • /
    • 2008
  • Currently an office in information society is advanced to a digitalized VDT office. The VDT office has a natural luminous system prioritizing visual perception and so importance of lighting design by artificial lighting is emphasized in the VDT office. The purpose of the study is to analyze Illumination and Luminance for lighting design by the standard of ergonomics in the VDT office. The study analyzed Illumination and Luminance in the main control room of an nuclear power plant needing a design of ergonomics ACR(Advanced Control Room) type Ling Ao phase II NPP MCR in Guangdong, China. The study examined the relativity of ACR characteristics to its operator's duties and set up an outline of lighting design, the standard of ergonomics and input data for the analysis. Thus, the study examined appropriateness with the standard of ergonomics setting up the analyzed Illumination and Luminance and drew a conclusion.

서울지역 학교 교실의 실내환경 조사연구 (A Study on the Indoor Environment of school classrooms in Seoul area)

  • 최한영
    • 환경위생공학
    • /
    • 제18권2호
    • /
    • pp.67-74
    • /
    • 2003
  • In 15 schools where were chosen each location (East, West, South, North, Central) of Seoul area, 9 items were measured such as thermo circumstance(temperature, relative humidity, air current, intensity of illumination) particulate matter, carbon monoxide, sulfur dioxide, and nitrogen dioxide being based on the school indoor environment standard. It was showed that indoor temperature, relative humidity and air movement were suitable in comparison with school indoor environment standard. Intensity of illumination was suitable in comparison with all schools, only exception 2 schools. In all investigated schools were adequate for carbon monoxide, sulfur dioxide and nitrogen dioxide, in which each indoor environment standard (10ppw, 0.25ppm/hr, 0.15ppm/hr), but in 5 schools the carbon dioxide were exceeded for standard limit 1,000ppm of Korea. Indoor concentration of dust(PM-10) induced from respiration dust the standard of Korea ($150{\mu}g/m^3$) at all schools.

객체의 색상 항등성을 위한 조명 모델 응용에 관한 연구 (A Study on Application of Illumination Models for Color Constancy of Objects)

  • 박창민
    • 디지털산업정보학회논문지
    • /
    • 제13권1호
    • /
    • pp.125-133
    • /
    • 2017
  • Color in an image is determined by illuminant and surface reflectance. So, to recover unique color of object, estimation of exact illuminant is needed. In this study, the illumination models suggested to get the object color constancy with the physical illumination model based on physical phenomena. Their characteristics and application limits are presented and the necessity of an extended illumination model is suggested to get more appropriate object colors recovered. The extended illumination model should contain an additional term for the ambient light in order to account for spatial variance of illumination in object images. Its necessity is verified through an experiment under simple lighting environment in this study. Finally, a reconstruction method for recovering input images under standard white light illumination is experimented and an useful method for computing object color reflectivity is suggested and experimented which can be induced from combination of the existing illumination models.

A Study on the Operator Performance According to the Drastic Change of Illumination Level and Lighting Environment of Control Room in Nuclear Power Plants

  • Shin, Kwang Hyeon;Lee, Yong Hee
    • 대한인간공학회지
    • /
    • 제32권1호
    • /
    • pp.37-45
    • /
    • 2013
  • Objective: This study describes the change of operator performance in drastic change of illumination level, and proposes an alternative method to cope with it. Background: The control standard of illumination for nuclear power plants(NPPs) is based on the set of limit criteria for maintaining a specific illumination level. However, there is a possibility to cause human errors according to the psychological and physiological influences to operators in the situation of drastic change of illumination such as SBO(Station Black Out), so a basic study is necessary to review the current approach. Method: We assessed the visual fatigue, subjective work load and task performance according to the three illumination situations(Normal Illumination, Emergency Illumination, and Drastic Change of Illumination). Result: Research finding shows that there are not significant differences in task performance between normal illumination (1,000lx level) and emergency illumination (100lx level), only if beyond the dark adaptation limit. However, subjective work load on mental demand and visual fatigue show a potential challenge to visual performance in drastic change of illumination. Conclusion/Application: Several trials can complement this challenge in NPPs by applying 3-way communication, enhancing readability of procedures, and managing the visual factors affecting the operators' performance through a Visual Environment Management Program including visual health aspects, etc.

공공도서관의 환경개선을 위한 조도 분석 및 개선 방안에 관한 연구 (A Study on the Illumination analysis and Improvement plan for the Public Library Environment)

  • 권선영
    • 한국융합학회논문지
    • /
    • 제9권8호
    • /
    • pp.47-52
    • /
    • 2018
  • 최근 도서관의 모습은 그 어느 때보다도 극적으로 변화하고 있으며 이러한 변화의 한 가운데는 도서관의 공간적 요소가 큰 부분을 차지하고 있다. 본 연구는 국내 외 조도 관련 선행연구 분석 및 실측 조사 그리고 각국의 조도 관련 기준을 비교하여 도서관의 조도 기준의 개선 방향의 기준을 마련하고 도서관의 학습 및 열람공간과 전반적인 이용자 공간의 더 나은 조도 환경을 구축하기 위한 조도 개선점을 제안하는 것에 그 목적이 있다. 연구 목적을 달성하기 위하여 대전광역시 공공도서관 중 14개의 도서관을 대상으로 조도 측정 후 이용자들의 인식을 조사하였다. 마지막으로 국내외 조도기준에 대한 비교를 통해 앞으로 국내 조도규격이 개선되어야 할 점을 살펴보았다. 분석결과 현재 국내의 조도관련 기준은 시대에 맞게, 그리고 각 국가의 사례를 바탕으로 보완해야 할 필요성이 있는 것으로 나타났다. 또한 이용자의 연령층에 따른 차별화와 조도에 대한 중요성 인식이 필요한 것으로 나타났다. 본 연구는 향후 도서관의 전반적인 조도개선과 조명 관리에 대한 관심을 불러일으키는 기초연구가 될 것으로 기대되며 국외 권장 조도의 개정 동향에 맞게 국내 조도규격에 대한 개정과 추후 도서관 조도에 대한 지속적인 연구를 바탕으로 관심이 지속된다면 국내 공공도서관 조명 개선에 큰 힘이 될 것으로 예상된다.

시뮬레이션프로그램을 활용한 교실조도 분석 및 개선방안 (An Analysis of Classroom Illuminance with Simulation Program and Improvement of Classroom Illumination)

  • 신현만;장우진
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.129-134
    • /
    • 2009
  • 학교 조명실태를 조사하고 교실 1실에 설치된 조명기구의 수량별로 분류하고, 분류된 형태별로 조도를 측정하여 조도실태를 분석하였다. 책상면 조도는 학교시설기준을 만족하나 칠판용 국부조명을 설치하지 않은 경우 칠판조도가 학교시설기준에 미치지 못하였다. 교실 마감재 반사율 측정과 램프교체 및 램프청소 실험 등 실제로 측정한 자료를 기초로 하여 시뮬레이션 한 결과 현실적으로 전반조명 9등과 칠판용 국부조명이 필요하였으며, 유지관리를 고려한 설계가 요구됨을 알 수 있었다.

  • PDF