• 제목/요약/키워드: Standard Frequency Deviation

검색결과 1,073건 처리시간 0.021초

The loss coefficient for fluctuating flow through a dominant opening in a building

  • Xu, Haiwei;Yu, Shice;Lou, Wenjuan
    • Wind and Structures
    • /
    • 제24권1호
    • /
    • pp.79-93
    • /
    • 2017
  • Wind-induced fluctuating internal pressures in a building with a dominant opening can be described by a second-order non-linear differential equation. However, the accuracy and efficiency of the governing equation in predicting internal pressure fluctuations depend upon two ill-defined parameters: inertial coefficient $C_I$ and loss coefficient $C_L$, since $C_I$ determines the un-damped oscillation frequency of an air slug at the opening, while $C_L$ controls the decay ratio of the fluctuating internal pressure. This study particularly focused on the value of loss coefficient and its influence factors including: opening configuration and location, internal volumes, as well as wind speed and approaching flow turbulence. A simplified formula was presented to predict loss coefficient, therefore an approximate relationship between the standard deviation of internal and external pressures can be estimated using Vickery's approach. The study shows that the loss coefficient governs the peak response of the internal pressure spectrum which, in turn, will directly influence the standard deviation of the fluctuating internal pressure. The approaching flow characteristic and opening location have a remarkable effect on the parameter $C_L$.

반폐쇄성도훈련이 기능적 실성증 환자의 음성 개선에 미치는 효과 (Effects of Semi-Occluded Vocal Tract Exercise in Patients with Functional Aphonia)

  • 채혜림;김지성;이동욱;최성희
    • 대한후두음성언어의학회지
    • /
    • 제30권1호
    • /
    • pp.48-52
    • /
    • 2019
  • Background and Objectives : Functional aphonia is characterized by incomplete closure of the vocal folds. Semi-occluded vocal tract exercise (SOVTE) allows smoothly vocal folds collision without damage to the vocal folds tissues to produce normal vocal intensity. The purpose of this study is to report the effect of SOVTE in patients with functional aphonia. Materials and Method : Seven patients diagnosed with functional aphonia were treated with 1-3 voice therapy sessions using voiced lip-trill, humming, Lax Vox in SOVTE. To assess the effectiveness of semi-occluded vocal tract exercise, cepstral analysis and auditory perceptual assessment were performed before and after voice therapy. Results : F0 (fundamental frequency), CPP (cepstral peak prominence) and L/H ratio (low/high spectral ratio) were significantly increased, while CPP Standard deviation, L/H ratio Standard deviation were decreased. In addition, 'Grade', 'Breathiness' and 'Asthenia' were significantly decreased in the GRBAS scale after SOVTE (p<0.05). Conclusion : In our study, SOVTE seemed to be effective to elicit voice quickly and promote vocal folds vibration without muscular effort in patients with functional aphonia.

음향산란이론모델을 이용한 멸치(Engraulis japonicus)의 음향산란강도 추정 (Target Strength of Anchovy Engraulis japonicaus by Theoretical Acoustic Scattering Model)

  • 박근창;오우석;이유원;이형빈;이경훈
    • 한국수산과학회지
    • /
    • 제57권3호
    • /
    • pp.302-309
    • /
    • 2024
  • This study estimates the target strength of anchovy Engraulis japonicus required for studying their distribution and density using acoustics and evaluates the acoustic scattering characteristics of anchovies by frequency using the Kirchoff ray mode (KRM) model. The experiment was conducted on 30 anchovies with 4.7-21.5 cm total length. The maximum TScm (Simming angle, 9.1°; standard deviation, ± 13.1°) according to total length was -66.9, -65.2, -64.4, and -63.4 dB at 38, 70, 120, and 200 kHz, respectively. The average TScm (Simming angle: 9.1°, standard deviation: ± 13.1°) according to total length was -68.9, -68.8, -69.6, and -70.0 dB at 38, 70, 120, and 200 kHz, respectively. The results of this study provide an important basis for future studies that use acoustics to estimate the target strength of anchovies.

수정된 라플라시안 센서를 이용한 심박변이도 측정에 관한 연구 (A Study on the Measurement of Heart Rate Variability using the Modified Laplacian Electrodes)

  • 이충근;신항식;김홍래;이정환;김용준;이명호
    • 전기학회논문지
    • /
    • 제58권5호
    • /
    • pp.1050-1056
    • /
    • 2009
  • Heart Rate Variability(HRV) is a parameter that represents monitoring variability of time intervals between R-peak in electrocardiography. HRV serves to various applications, such as indices of autonomic functions, prediction of cardiac sudden death, assessment of stress and emotional, etc. However, as measuring R-peak in ECG needs at least 3-electrodes, and it is inconvenient for end users. In this paper, we suggested the modified laplacian electrodes for measuring HRV at one-point, which are producted by MEMS fabrication and have the two circular electrodes on the pad. For optimal position and direction, we performed an experiment that compared with pearson correlation coefficient and the amplitude of signals, between standard lead II and proposed electrodes. We analyzed the HRV parameters, such as standard deviation of the NN interval(SDNN), high frequency(HF), low frequency(LF), LF/HF ratio. The result showed that the average correlation coefficient and amplitude are 0.967 and 0.685 mVpp at the position 2. The coeffiecient correlation between the standard HRV and proposed electrode-HRV is 0.999

$CO_2$ 용접의 단락이행 조건에서 스패터 발생과 파형인자와의 관계 (Relation between Spatter Generation and Waveform factor of $CO_2$ Welding in Short-Circuit Condition)

  • 김희진;강봉용;이강희;유중돈
    • Journal of Welding and Joining
    • /
    • 제16권3호
    • /
    • pp.95-101
    • /
    • 1998
  • Waveforms of $CO_2$ gas shielded arc welding in short circuit transfer mode was studied with the waveform analysis program, which can calculate various waveform factors such as number of short circuit event, mean and standard deviation of short circuit time and arc time. The calculated values of these factors were correlated independently or in combination with the spatter generation rate to figure out the most reliable index for evaluating spatter generation and further for arc stability. As a result this study, it was confirmed that the spatter generation tends to decrease with the increase of short circuit frequency. Further to this, it was also found that as the short circuit frequency increases the short circuit event becomes more uniform resulting in the decrease of standard deviations ($\sigma$values) of short circuit time and arc time. This result demonstrated that these factors are strongly correlated with each other and thus any one of these factors can be used for the evaluation index. In the discussion, however, short circuit frequency was proposed for the most practical index in evaluating the arc stability of short circuit transfer mode since it is the one which could be monitored in-process condition without any complex caculation process.

  • PDF

중량 바닥충격음 충격원의 종류 및 위치에 따른 수음실 음압레벨 변화 (Deviation of sound pressure level in receiving room according to the heavy-weight floor impact sources and it's positions)

  • 주문기;한명호;오양기
    • KIEAE Journal
    • /
    • 제9권4호
    • /
    • pp.23-28
    • /
    • 2009
  • Standard sound source currently used in heavy-weight floor impact sounds that cause many social problems has excessive low-frequency energy within a range from 63 Hz to 125 Hz, and is difficult to evaluate and measure. To solve these problems, studies are widely performed using a new impact source, the impact ball. In this study, the sound fields in a receiving room were compared and analyzed according to the current impact source, the bang machine, and the impact ball. And deviation of sound pressure level according to the impact source positions were compared. In case of impact ball, the sound pressure level was lower at 63 Hz and below and higher at 125 Hz and above. The same trend was observed at the low-frequency range on the horizontal and vertical planes, regardless of the type of the impact source, which showed the influence of the room mode. There was a problem with the variations in the sound pressure level according to the size or shape of the receiving room. And it also shows that change of source positions may effect the single number rating scheme.

Wavelet을 이용하여 하드터닝 공정에서 표면품위의 향상을 위한 채터 진단에 관한 연구 (Chatter Detection for Improving Surface Quality of Hard Turning Process with Wavelet Transformation)

  • 박영호;공정흥;양희남;김일해;장동영;한동철
    • 대한기계학회논문집A
    • /
    • 제28권1호
    • /
    • pp.70-78
    • /
    • 2004
  • This paper presents study of efficiency of wavelet transformation for on-line chatter detection during hard fuming process. From comparison with other time series and statistical methods such as fast fourier transformation (FFT), Kurtosis and standard deviation (STD), wavelet transform is better than others in on-line chatter detection. With using wavelet function with pseudo frequency corresponding to chatter frequency, chatter could be detected more sensitively. And for both force signal from dynamometer and displacement signal from capacitance type cylindrical sensor (CCS), wavelet transform with DB2 function on level 4 could be well used for chatter detection in hard turning process.

여성의 신체노출의상에 대한 인지적 평가 (Cognitive Evaluation on Body Exposure of Female Clothing)

  • 조은영;홍병숙
    • 한국의류학회지
    • /
    • 제19권5호
    • /
    • pp.723-737
    • /
    • 1995
  • The purposes of this study were to investigate 1) the difference of cognitive evaluation on body exposure of female clothing, ann 2) purchase frequency and intention of wearing according to demographic variables. The instrument of this study consisted of response scale and stimuli. Thirty three items of 7.point Likert scale were developed to measure cognitive evaluation of the people who responded. The stimuli were 7 types of clothing, differing exposure parts and style on line drawing. The sample included 450 subjects, consisting of 231 in Seoul and 219 in Chun-nam Province. Statistics applied for analysis were frequency, percentage, mean, standard deviation, correlation, t-test, F-test, Duncan's multiple range test, factor analysis. The Results were: 1. Constructing factors of cognitive evaluation consisted of elegance, sensuality, attraction, individuality. There were significant differences in every factor on each types of clothing. 2. The evaluation toward each types of clothing was influenced by the subjects' sex, age, and residence. 3. Purchase frequency and intention of female subjects' wearing were very low, and there were significant differences on demographic variables.

  • PDF

대역 분할 부호화 기법을 이용한 EEG 데이타 압축 (EEG data compression using subband coding techniques)

  • 이종욱;허재만;김택수;박상희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 정기총회 및 추계학술대회 논문집 학회본부
    • /
    • pp.338-341
    • /
    • 1993
  • A EEG(ElectroEncephaloGram) compression scheme based on subband coding techniques is presented in this paper. Considering the frequency characteristics of EEG, the raw signal was decomposed into different frequency bands. After decomposition, optimal bit allocation was done by adapting to the standard deviation in each frequency bands, and decomposed signals were quantized using pdf(probability density function)-optimized nonuniform quantizer. Based on the above mentioned coding scheme, coding results of various multichannel EEG signal were shown with compression ratio and SNR(signal-to-noise ratio).

  • PDF

공정영향을 고려한 비연성 진동형 마이크로 자이로스코프의 강건 최적 설계 (Robust Optimal Design of a Decoupled Vibratory Microgyroscope Considering Fabrication Influence)

  • 정희문;하성규
    • 대한기계학회논문집A
    • /
    • 제28권8호
    • /
    • pp.1065-1074
    • /
    • 2004
  • A robust optimal design considering fabrication influence has been performed for the decoupled vibratory microgyroscope fabricated by the bulk micromachining. For the analysis of the gyroscope, a design tool has been developed, by which user can perform the system level design considering electric signal process and the fabrication influence as well as mechanical characteristics. An initial design of the gyroscope is performed satisfying the performances of scale factor (or sensitivity) and phase delay, which depend on the frequency difference between driving and sensing resonant frequencies. The objective functions are formulated in order to reduce the variances of the frequency difference and the frequency in itself by fabrication error. To certify the results, the standard deviations are calculated through the Monte Caries Simulation (MCS) and compared initial deviation that is measured fabricated gyroscope chip.