• Title/Summary/Keyword: Standard Enforcement

Search Result 163, Processing Time 0.028 seconds

The Classification and Regional Development's Direction of Rural Fishing Area Based on Administrative District (행정구역에 기초한 어촌지역의 유형구분과 지역개발방향)

  • Kim, Jung-Tae
    • Journal of Korean Society of Rural Planning
    • /
    • v.19 no.4
    • /
    • pp.81-93
    • /
    • 2013
  • The selection of land for fishing village development project, and the standard used to classify fishing villages has been determined based on the guidelines developed by fishing village cooperatives. The approach fishing village cooperatives follows is likely to classify fishing villages without first reflecting on the overall development environment of the region, such as other industries and workers in the area. It also acts as a barrier for business promotion or evaluation, because the cooperatives do not match the administrative districts, which are the units of administration, and the main policy enforcement agent in regional development. Against this background, this study aimed to identify categories to situate the development direction, as well as the size and distribution of fishing villages based on eup, myeon, and dong administrative units as defined by the Fishing Villages and Fishery Harbors Act. This study was based on the Census of Agriculture, Forestry, and Fisheries of 2010, and analyzed 826 eups, myeon, and dongs with fishery households using the principal component analysis, and 2-Step cluster analysis methods. Therefore, 95% of the variance was explained using the covariance matrix for types of fishing villages, but it was analyzed as one component focusing on the number and ratio of fishery households, and used the cluster-type analysis, which focused on the sizes of fishing villages. The clusters were categorized into three types: (1) the development type based on the number of fishermen in the eups, myeons and dongs was analyzed as village size (682); (2) administrative district size (121); and (3) total eups, myeons and dongs (23), which revealed that the size of most fishing villages was small. We could explain 73% of the variance using the correlation coefficient matrix, which was divided into three types according to the three principal component scores, namely fishery household power, fishery industry power, and fishing village tourism power. Most fishing villages did not have a clear development direction because all business areas within the region were diversified, and 552 regions could be categorized under the harmonious development type, which is in need of balanced development. The fishery industry type typified by industrial strength included 159 regions in need of an approach based on industrialization of fishery product processing. Specialized production areas, which specialized in producing fishery products, were 115 regions with a high percentage of fishermen. The analysis results indicated that various situations in terms of size and development of fishing villages existed. However, because several regions exist in the form of small village units, it was necessary to approach the project in a manner that directed the diversification of regional development projects, such as places for local residents to relax or enjoy tourism experiences within the region, while considering the overall conditions of the relevant eups, myeons, and dongs. Reinforcement of individual support for fishermen based on the Fisheries Act must take precedence over providing support for fishermen through regional development. In addition, it is necessary to approach the development of fishing villages by focusing on industrializing the processing techniques of fishery products. Areas specialized in the production of fishery products are required to consider the facilities for fisheries production, and must make efforts to increase fishery resources, such as releasing fry.

The Establishment of Roles and Titles of Quality Control Personnel for Construction Project Quality Assurance (건설공사 품질확보를 위한 품질관리 관련자의 역할 및 호칭 정립)

  • Lee, Chang-Hyo;Kim, Byung-Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.5
    • /
    • pp.871-878
    • /
    • 2017
  • The quality control personnel of the construction work shall establish and execute the quality control plan or the quality test plan and check the qualification of the used materials according to the process, the management of the test and inspection equipment, the quality education, the own quality inspection and measures. Management and quality test of Korea and plays an important role in preventing accidents. However, related organizations did not explicitly disclose their roles in quality testing and quality control tasks while changing the names of quality control personnel to test personnel and quality managers when revising related laws and regulations and the application of labor costs. Therefore, a research of this is needed to improve conflicting situation. In this study, the ambiguous title relation to the quality control persons is improved to meet the requirements of the construction work based on related laws and regulations, and each role and title is classified as 'quality tester' and 'quality manager'. In other words, the person who carries out the quality test of the "Construction Quality Test Standard" specified in the Guideline for Quality Management of Construction Projects shall be the "Quality Tester" and the person who performs the quality control plan establishment and execution work specified in the Enforcement Rule of the Construction Technology Promotion Act shall be referred to as the 'Quality Manager'.

Phantom of the AAPM CT imaging evaluation Studies on the quantitative analysis method (CT 정도관리 영상의 정량적 분석방법에 관한 연구)

  • Kim, Young-su;Ko, Seong-Jin;Kang, Se-Sik;Ye, Soo-young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.271-274
    • /
    • 2016
  • CT quality assurance imaging evaluation and enforcement as quantitative assessment by phantom image evaluation, assessment items include There are also contrasting the water attenuation coefficient, uniformity, noise, resolution, spatial resolution, 10mm slice thickness evaluation, contrast resolution, space for the resolution, the slice thickness evaluation, it is possible to estimate the error due to the evaluation by the subjective judgment of the tester, using a subjective error image processing program to be computed to minimize the objective evaluation. Basic recording conditions of the CT image quality control assessment is the same as special medical equipment quality control checks, the images were evaluated quantitatively using IMAGE J. For a CT attenuation coefficient, the uniformity, noise evaluation, were evaluated as CT quality control image the standard deviation of the measured value of the digital processing of image smaller and less noise uniform images than the, contrast and resolution assessment is the size of the diameter of a circle having a large the 1 inch, 0.75 inch, 0.5 inch quality if the diameter of the circle, was evaluated in the small circle in the near circle ellipse. Spatial resolution is evaluated by using a self-extracting features of an image processing program, all of the groups of members comprising the acceptance criteria to automatically extract, was evaluated to be very useful for the quantitative assessment. When CT image quality control assessment on the basis of the results such as the above, if using an image processing program to minimize the subjective judgment of the error evaluator and is determined more efficient than would be made quantitative evaluation.

  • PDF

A Study on the Problem and Improvement of Screening System of Low Price Subcontracting by Analyzing a Standard of Judgement Criteria (원도급자 측면에서의 저가하도급 판정기준의 문제점과 개선방안)

  • Kim, Soon-Young;Han, Choong-Hee;Baek, Tae-Ryong;Kim, Kyoon-Tai;Lee, Jun-Bok
    • Korean Journal of Construction Engineering and Management
    • /
    • v.10 no.6
    • /
    • pp.107-116
    • /
    • 2009
  • As the Fundamentals of Construction Business Act was revised in December 2004 and its implementing ordinances and enforcement regulations were adjusted in June 2005, the screening system of low price subcontracting has been an obligation to the public owners, having brought about arguments for and against since it enacted in 1983. The statutes for low price subcontracting have been reinforced from this year; for example, it underlines to submit to a project and builds an information network of subcontracting works. The system's original intention was that prevents shoddy and fraudulent constructions caused by low price subcontracting and precludes disturbances of fair trade by screening that whether it satisfies the conditions or not in advance. But, the criterion for the existing low price subcontracting has several issues having held up a true mirror to the real situation. It is arguable to discharge an important task with the primary purpose. This dissertation have researched the problem with a deposit of subcontract and the low price subcontracting basic rate are being used by the criteria for deciding whether it is a low price subcontracting or not, so showing the plan of reformation based on the findings, it wishes to contribute toward making the most of the system's essential intent.

A Study on an acceptance of CDC guideline on practical emergency department planning -Focusing on comparison CDC guideline to Emergency Medical Service Act- (응급실에서의 감염관리 표준지침의 반영에 관한 연구 -응급실에서의 감염관리 표준지침과 응급의료에 관한 법률의 반영 비교를 중심으로-)

  • Yoon, Hyung Jin;Oh, Joon-Gul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.11
    • /
    • pp.7237-7243
    • /
    • 2015
  • Korea Centers for Disease Control and Prevention(CDC) has been provided not only manual of managing infectious patient but also functional requirement of space in emergency department(ED) by distributing "Guideline for infection control in emergency department(GICED)" in 2009. To understand how much the guideline enforces its functional requirement on ED planning practice, it is compared to Emergency Medical Service Act(EMSA) a basic standard for ED planning. As a result, it is clear that those have different focal point in functional program and don't share infection control issue. By reviewing target hospitals' EDs opened around 2009, all ED have satisfied with the EMSA requirement but guideline. Those are selectively adapted infection control related spaces CDC guideline suggested regardless of open year so that target EDs are not to be influenced by the guideline. This research can support as a reference research when the EMSA are going to be reinforced by infection contol issue.

A Selection Model of Suitable Tendering System for Public Construction Projects (공공건설공사의 최적 입찰방식 선정모델)

  • Yu, Il-Han;Kim, Kyung-Rai
    • Korean Journal of Construction Engineering and Management
    • /
    • v.9 no.3
    • /
    • pp.164-174
    • /
    • 2008
  • It is crucial In decision making to select a project delivery system (PDS) adjusted accordingly to the project characteristics. Furthermore, selecting a tendering system is the kernel in the process of selecting PDS. In October 2007, the Ministry of Finance and the Economy of Korea launched two new project delivery systems, "Best Value Contract (Design-Bid-Build)" and "Bridging Contracts (Design-Build)" by revising enforcement ordinances of "Act on Contracts to Which the State is a Party" to provoke the tendering systems. In order to support the proposed purpose, this research developed a selection model for suitable tendering system, which helps a public owner select a tendering system appropriate to the project characteristics. First, the framework of the model was set throughout analyzing previous researches and interviewing relevant experts. Additionally, by analyzing the survey result from 265 experts engaged in architectural and civil engineering business, the relative weights of the selection factors and the effectiveness values of the alternatives were suggested as the quantitative evaluation references. Finally, the practical guideline was suggested to apply this model to three public projects scheduled to be delivered. The result of applying the model to three case projects showed that further researches were needed to make the selection process logical and to suggest the standard weights and effectiveness values according to project type.

A Study on the Effective Implementation of a Marine Incident System (준해양사고제도의 효율적 이행을 위한 개선방안에 관한 연구)

  • Chae, Byeong-Geun;Lee, Ho;Kim, Hong-Beom;Kang, Suk-Young
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.4
    • /
    • pp.398-407
    • /
    • 2018
  • Standard guidelines for marine accident investigation have been prepared through the enforcement of the Casualty Investigation code as of January 2010. In addition, as the International Maritime Organization (IMO) recommended contracting the state to manage a marine incident system established under this code, Korea also has newly established provisions for a marine incident system in the 'Act on the Investigation of and Inquiry into Marine Accidents' also as of 2010. The Korean Maritime Safety Tribunal (KMST) has made a multilateral effort to prevent marine accidents through the efficient operation of a marine incident system, but this system has not been properly activated. This study examines the operational status and problems of a marine incident system and analyzes the marine incident systems of foreign countries and similar transportation agencies such as railroads and aviation. Options include switching to voluntary reporting of marine incidents, transferring responsibility to a non judicial private organization, expanding incentive systems for a marine incidents, revising regulation and preparing detailed implementation guidelines.

Optimal Management Scheme for Phosphorus Discharged from Public Sewage Treatment Plant Located in Upstream Basin of Paldang Lake (팔당호 상류수계에 위치한 공공 하수종말처리시설의 총인 배출 최적관리)

  • Woo, Younggug;Park, Eunyoung;Jeon, Yangkun;Jeong, Myungsuk;Rim, Jaymyung
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.2
    • /
    • pp.200-209
    • /
    • 2011
  • The purpose of the study is to optimally manage sewage treatment plant with analysis of phosphorus contribution and improvement of water quality contributing rate in the effect of inflowing point of effluent and Pal-Dang lake after reducing T-P discharge from large scale public sewage treatment plant at upstream of Pal-Dang lake. Also, this study, for enforcement of T-P in effluent, plans optimal management of effluent T-P through examining propriety of environmental, technological, and economical aspect such as water quality standard of domestic and foreign T-P and related policy. In regarding optimal management of T-P discharged from public sewage treatment plant located in upstream of Pal-Dang lake, the study drew following conclusions. With the optimal management of public sewage treatment plant, it showed that a pollution level became higher in the order of Sumgang E in South-Han river, C in Dalcheon, B1 B2, A in North-Han river, and J in Kyungancheon, and it is required reduction of T-P first. The highest value in analysis of benefit-costs from sewage treatment plant in the selected research area was Kyungan B, and the others are with the order of Jojong A, Bokha A, Kyungan A, and Yanghwa A. With result of this study, all 14 areas are required more enforced phosphorus treatment. The study resulted that the most top priority areas were Hangang F, Sumgang B, and Gyungan A, top priority areas were Bokha A, Dalcheon B, and Cheongmi A, priority areas were Hangang E, Heukcheon A, Gyungan B, and Jojong A, and potential areas were Sumgang A, Yanghwa A, Dalcheon A, and Hangang D. It seems to be appropriate to apply 0.2 mg/L of T-P treatment for water supply source reservation, 0.5 mg/L for the other areas by locally, and 0.2~0.5 mg/L for biological nitrogen phosphorus treatment method and 0.5~1 mg/L for Conventional Activated Sludge by technologically. Also, it may be appropriate to apply 0.2 mg/L for the most top priority area(I), 0.3 mg/L for the top priority area(II), 0.4 mg/L for priority area(III), and 0.5 mg/L for potential area(IV) by the separation of priority area.

Improvement of Acid Digestion Method by Microwave for Hazardous Heavy Metal Analysis of Solid Refuse Fuel (고형연료제품의 유해중금속 분석을 위한 마이크로파 산 분해법의 개선)

  • Yang, Won-Seok;Park, Ho-Yeun;Kang, Jun-Gu;Lee, Young-Jin;Lee, Young-Kee;Yoon, Young-Wook;Jeon, Tae-Wan
    • Journal of Korea Society of Waste Management
    • /
    • v.35 no.7
    • /
    • pp.616-626
    • /
    • 2018
  • The quality standards of solid refuse fuel (SRF) define the values for 12 physico-chemical properties, including moisture, lower heating value, and metal compounds, according to Article 20 of the Enforcement Rules of the Act on Resource Saving and Recycling Promotion. These parameters are evaluated via various SRF Quality Test Methods, but problems related to the heavy metal content have been observed in the microwave acid digestion method. Therefore, these methods and their applicability need improvement. In this study, the appropriate testing conditions were derived by varying the parameters of microwave acid digestion, such as microwave power and pre-treatment time. The pre-treatment of SRF as a function of the microwave power revealed an incomplete decomposition of the sample at 600 W, and the heavy metal content analysis was difficult to perform under 9 mL of nitric acid and 3 mL of hydrochloric acid. The experiments with the reference materials under nitric acid at 600 W lasted 30 minutes, and 1,000 W for 20 or 30 minutes were considered optimal conditions. The results confirmed that a mixture of SRF and an acid would take about 20 minutes to reach $180^{\circ}C$, requiring at least 30 minutes of pre-treatment. The accuracy was within 30% of the standard deviation, with a precision of 70 ~ 130% of the heavy metal recovery rate. By applying these conditions to SRF, the results for each condition were not significantly different and the heavy metal standards for As, Pb, Cd, and Cr were satisfied.

A Study on the Effect of Ratification of the Cape Town Agreement on Korean Deep-Sea Fishing Vessels (우리나라 원양어선의 케이프 타운 협정 비준 영향에 관한 연구)

  • RYU, Kyung-Jin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.5
    • /
    • pp.773-779
    • /
    • 2022
  • Deep-sea fisheries in Korea play an essential role in supplying popular seafood and providing food security. Countries, as well as the IMO (International Maritime Organization), have attempted to establish an internationally harmonized safety standard for fishing vessels. However, starting with the adoption of 'The Torremolinos International Convention for the Safety of Fishing Vessel 1977', the '2012 Cape Town Agreement' was adopted, but the requirements for enforcement were not met. However, with the 2019 Torremolinos Declaration, the effect of the agreement became visible. Korea is also about to ratify the agreement, and deep-sea fishing vessels are subject to the agreement. The length of the hull or the gross tonnage can be selected as the criteria for applying the 2012 Cape Town Agreement, and this is also partially applied to the existing vessels. Analyzing 188 deep-sea fishing vessels registered as members of the Korea Overseas Fisheries Association to confirm the effect on the existing vessels showed that the application of gross tonnage had little impact on the ratification of the agreement. In addition, laws must be revised for the compulsorization of GMDSS facilities such as two-way VHF and radar transponders and for the safety familiarization of fishermen. In the industry, the facilities required by the agreement must be provided, and the fishermen must be familiarized with safety.