• Title/Summary/Keyword: Standard Design Values

Search Result 496, Processing Time 0.032 seconds

A Numerical Study on Load Distribution Factors for Simplified Composite H-Beam Panel Bridges (강합성 초간편 H형강 교량의 하중분배계수에 관한 해석적 연구)

  • Park, Jong Sup;Kim, Jae Heung
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.3
    • /
    • pp.221-232
    • /
    • 2009
  • The load distribution factor (LDF) values of simplified composite H beam panel bridges (SCHPBs) that were subjected to one lane and two lane loads were investigated using three dimensional finite element analyses with the computer program ABAQUS (2007). This study considered some design parameters such as the slab thickness, the steel plate thickness, the span length, and the continuity of the SCHPBs in the development of new LDFs. The distribution values that were obtained from these analyses were compared with those from the AASHTO Standard, LRFD, and the equations presented by Tarhini and Frederick, Huo et al., Back and Shin, and Cai. The AASHTO Standard distribution factors for SCHPBs were found to be very conservative. Sometimes, the distribution values from the finite element analyses for interior girders were similar to the results of the AASHTO LRFD, whereas the values for exterior girders were conservative in most cases. The new distribution values that were presented in this study produced LDFs that are more conservative than those from the finite element method. For the simple application of the design to SCHPBs, bridge engineers can use 0.42 for the interior girder and 0.32 for the exterior girder. The proposed values improve the current design procedure for the LDF problem and increase SCHPB design efficiency.

The Application of Standard in According to Ground and Electrical Continuity Testing of Lightning Protection Equipment in Field (피뢰설비현장의 접지 및 전기적 연속성 시험에 따른 표준적용)

  • Song, Gil-Mok;Koo, Kyung-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.4
    • /
    • pp.583-588
    • /
    • 2014
  • In this study, there are examined to the grounding of lightning protection system and electrical continuity tests in the field. The standard for lightning protection system is different design or construction according to the characteristics of the structure. Ground is measured and compared at least four locations. According to the measured results in the field, the sampled values of the ground resistance are measured $5{\Omega}$ or less and the difference between each value is suitable as $0.2{\Omega}$ or less. The values of the electrical continuity test between ground and metal bodies are measured 3 groups such as isolated portion, the mechanical contacted portion, and the electrical continuity portion measuring $0.2{\Omega}$ or less. It is measured to be less than $0.2{\Omega}$ at all in metal bodies of underground. A metal body installed inside the structure is not isolated, but the resistance values are higher than $0.2{\Omega}$. Therefore, It must be carried out the structure having lightning protection system confirm the LPL(lightning protection level) and design the strategy.

Development of Nonlinear Fatigue Model Based on Particle Filter Method (파티클 필터기법을 통한 비선형 피로모델 개발 연구)

  • Mun, Sungho
    • International Journal of Highway Engineering
    • /
    • v.18 no.4
    • /
    • pp.63-68
    • /
    • 2016
  • PURPOSES : The nonlinear model of fatigue cracking is typically used for determining the maintenance period. However, this requires that the model parameters be known. In this study, the particle filter (PF) method was used to determine various statistical parameters such as the mean and standard deviation values for the nonlinear model of fatigue cracking. METHODS : The PF method was used to determine various statistical parameters for the nonlinear model of fatigue cracking, such as the mean and standard deviation. RESULTS : On comparing the values obtained using the PF method and the least square (LS) method, it was found that PF method was suitable for determining the statistical parameters to be used in the nonlinear model of fatigue cracking. CONCLUSIONS : The values obtained using the PF method were as accurate as those obtained using the LS method. Furthermore, reliability design can be applied because the statistical parameters of mean and standard deviation can be obtained through the PF method.

Determining N value from SPT blows for 30 cm penetration in weathered strata

  • Sun, Chang-Guk;Cho, Hyung-Ik;Kim, Han-Saem;Lee, Moon-Gyo
    • Geomechanics and Engineering
    • /
    • v.28 no.6
    • /
    • pp.625-636
    • /
    • 2022
  • The standard penetration test (SPT) obtaining the N value of the number of blows has been widely used in various subsurface conditions, including in weathered soil and rock on fresh bedrock, in geotechnical studies pertaining to the design of foundations and earth structures. This study examined the applicability of SPTs terminated conventionally after 50 blows for a penetration of less than 30 cm, particularly in weathered strata, at four sites in Korea. The N values obtained during practical SPTs are typically extrapolated linearly at 30 cm penetration, despite the possibility of a nonlinear relationship between blow counts and penetration. Such nonlinearity in weathered strata has been verified by performing special SPTs ensuring 30 cm penetration. To quantify the nonlinearity in dense strata, we conducted statistical regression analyses comparing the differences (DN) between the N values measured by the special SPTs and those extrapolated using the practical approach with the differences (DP) between the 30 cm penetration and the penetration during 50 blows. Bi-linear relationship models between DN and DP were subsequently proposed for determining the N values at 30 cm penetration in weathered strata. The N values reflecting nonlinearity could be determined from the linearly extrapolated N values by adding a modeled DN value.

A Study on Domestic Standard Parameter Setting for BIM-based Energy Performance Evaluation - Focused on Possession Area per Person of Occupants in Government Offices - (BIM 기반 에너지성능평가를 위한 국내 표준 매개변수 설정 방안에 대한 연구 - 공공청사 업무시설의 재실자 1인당 점유면적을 중심으로 -)

  • Lee, Yun-Jeong;Lee, Kweon-Hyoung;Kim, In-Han;Choo, Seung-Yeon
    • Korean Journal of Computational Design and Engineering
    • /
    • v.20 no.1
    • /
    • pp.11-21
    • /
    • 2015
  • Currently, the United States, the United Kingdom, Australia etc. are actively utilizing energy simulation for efficiency evaluation of building energy. However, domestic energy efficiency assessment system doesn't use energy simulation system properly at present: parameters based architecture plans and Ashrae Standard are inputted for the evaluation, because the input parameters for the simulation haven't been established yet. This fact causes poor reliability during energy simulation, as the values of the two standards are different from each other. Therefore, the aim of the study is to set domestic standard parameter for BIM-based energy performance evaluation, focusing on possession area per person of occupants at government office in Korea. We found that the difference among the result values occurred approximately 3% in the energy simulation. As a result of the analysis, possession area per person of occupants in Government office is $31.87m^2$. Other input parameters may be set based on this. This will increase the reliability of energy simulation through a domestic standard parameter.

The Standard of Sump Design in Pump Station (펌프장내 흡수정 설계 기준)

  • Roh, H.W.;Oh, O.S.;Lee, Y.H.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.589-592
    • /
    • 2005
  • In general, the function of intake structure, whether it be a open channel, a fully wetted tunnel, a sump or a tank, is to supply an evenly distributed flow to a pump station. An even distribution of flow, characterized by strong local flow, can result in formation of surface or submerged vortices, and with certain low values of submergence, may introduce air into pump, causing a reduction of capacity and efficiency, an increase in vibration and additional noise. Unfortunately in order to design the sump station, the reasonable code or the standards weren't presented yet in Korea. Thus, some researchers had often referred the HI code, JSME code or CEN code to design the sump station. This study aims to prescribe the standard of sump design which were matched well the Korean pump station. Thus, the HI code and TSJ code would be interpreted fully to Korean language, the part of interpreted clauses of the western codes would be selected to compose the standard.

  • PDF

Investigation of design values computation of wood shear walls constructed with structural foam sheathing

  • Shadravan, Shideh;Ramseyer, Chris C.
    • Advances in Computational Design
    • /
    • v.4 no.3
    • /
    • pp.223-238
    • /
    • 2019
  • This study investigated the ultimate lateral load capacity of shear walls constructed with several types of structural foam sheathing. Sixteen tests were conducted and the results were compared to the published design values commutated by the manufactures for each test series. The sheathing products included 12.7 mm (1/2 in) SI-Strong, 25.4 mm (1 in) SI-Strong, 12.7 mm (1/2 in) R-Max Thermasheath, and 2 mm (0.078 in) ThermoPly Green. The structural foam sheathing was attached per the manufacturers' specification to one side of the wood frame for each wall tested. Standard 12.7 mm (1/2 in) gypsum wallboard was screwed to the opposite side of the frame. Simpson HDQ8 tie-down anchors were screwed to the terminal studs at each end of the wall and anchored to the base of the testing apparatus. Both monotonic and cyclic testing following ASTM E564 and ASTM E2126, respectively, were considered. Results from the monotonic tests showed an 11 to 27 percent smaller capacity when compared to the published design values. Likewise, the test results from the cyclic tests showed a 24 to 45 percent smaller capacity than the published design values and did not meet the seismic performance design criteria computation.

Analysis of Response Spectrum of Ground Motions from Recent Earthquakes (최근 발생지진 관측자료를 이용한 응답스펙트럼 분석)

  • Kim, Jun-Kyoung
    • Tunnel and Underground Space
    • /
    • v.19 no.6
    • /
    • pp.490-497
    • /
    • 2009
  • The horizontal and vertical response spectra using the observed ground motion from the recent 5 macro earthquakes were analysed and then were compared to both the seismic design response spectra(Reg Guide 1.60), applied to the domestic nuclear power plants, and the Korean Standard Design Response Spectrum for general structures and buildings(1997). 74 horizontal and 89 vertical observed ground motions, without considering soil types, were used for normalization with respect to the peak acceleration value of each ground motion. The results showed that the horizontal MPOSD(Mean Plus One Sigma Standard Deviation) response spectra revealed much higher values for the whole frequency bands above 1 Hz than Reg. Guide(1.60). For the vertical response spectra, the results showed slightly higher than just between 7 and 8 Hz frequency band. The results were also compared to the Korean Standard Response Spectrum for the 3 different soil types and showed that the horizontal MPOSD response spectra revealed much higher values for the whole periods below 2 second(0.5 Hz) than those of SE soil type. The vertical response spectra showed similar to the values of the Korean Standard Response Spectrum of SD soil type. These spectral values dependent on frequency could be related to characteristics of the domestic crustal attenuation and the effect of each site amplification. However, through the qualitative improvements and quantitative enhancement of the observed ground motions, the conservation of horizontal seismic design response spectrum should be considered more significantly for the whole frequency bands above the 1 Hz.

Development of Numerical Calculation Software for OTF from Lens Design Data (광학설계제원으로부터의 OTF 수치계산 S/W 개발)

  • 이종웅
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.4
    • /
    • pp.381-389
    • /
    • 1993
  • A software to calculate diffraction OTF from lens design data was developed and its accuracy was verified. To verify the accuracy, MTF of a standard lens system for OTF measurement were calculated. The results were compared with calculated values by another commercial software and measured values. We found that they have good agreements with one another.

  • PDF

An Error Sensitivity Analysis of Tape Traveling Path due to Geometric Variations of Tape Transport Elements of VHS VTR (VHS 방식 VTR 주행계 요소의 기하학적 배치 변동에 따른 주행경로의 오차민감도 해석)

  • 최진호;최동훈
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.11
    • /
    • pp.2655-2663
    • /
    • 1993
  • In order to evaluate the relative significance of tolerance management of various elements in a VHS VTR tape transport system, the effect of geometric variations of the elements from standard design values on the tape traveling path is studied. The tape is modeled as a string and each element in the tape transport system is modeled as a cylinder whose radius, position vector and orientation vector are specified. An numerical algorithm is proposed to find the coordinates of tape entry points and tape exit points for the elements from which the tape traveling path can be completely described. By using the suggested algorithm, an error sensitivity analysis of tape traveling path due to the geometric variations of tape transport elements is performed for a particular model in the market and the elements demanding relatively strict tolerance management are identified.