• Title/Summary/Keyword: Stand-Alone Operation

Search Result 115, Processing Time 0.024 seconds

Development of Stand-Alone Underground Water Pumping System using Photovoltaics System (태양광발전을 이용한 독립형 지하수 양수 시스템 개발)

  • Lee, Seung-Hun;Hwang, Jung-Hoon;Cho, Woon-Sik;Kim, Man-Il;Lee, Joon-Gee;Park, Moon-Hee
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.69-72
    • /
    • 2009
  • In this paper, the Stand-alone underground water pumping system was developed that is consist of Submersible Pump (AC type), Photovoltaic Array and Power converter by the application of solar energy. And also wish to introduce system that is possible to supply of drinking water or water for agriculture using solar energy at desertification area or a Off-grid area, interior etc. and operation test results. This system can use in deep tube well of 200m range with common Submersible Pump and maximized to the quantity of pumping through M.P.P.T control. Also system availability raised through apply various driving mode.

  • PDF

A Study on Parallel Operation Between Inverter System and Utility Line (인버터 시스템과 상용 전력 계통과의 병렬 운전에 관한 연구)

  • 천희영;박귀태;유지윤;안호균
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.4
    • /
    • pp.369-378
    • /
    • 1992
  • This paper proposes a utility parallel processing inverter system, which consists of a voltage source PWM inverter, isolation transformer and a reactor linking the inverter to utility line. This system realizes following functions : (1) voltage phase frequency and amplitude synchronization between inverter and utility line at stand-alone mode. (2) current phase synchronization between inverter and load at parallel mode. Therefore, despite sudden increase in load current over setting point at stand-alone mode, inverter system can be transferred into parallel mode immediately without transient current. Furthermore, high frequency(18KHz) PWM control and sinusoidal filtering improve the inverter output waveform by eliminating high order harmonic components as well as low order. As a switching device, IGBT is used for high frequency switching and large current capacity.

  • PDF

Parallel operating technique for the stand alone PV PCS (독립형 태양광 인버터의 병렬 운전 기법)

  • Jeong, Ku-In;Kwon, Jung-Min
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.6
    • /
    • pp.9-15
    • /
    • 2015
  • In this paper, a parallel operating technique for the stand alone photovoltaic (PV) power conditioning system (PCS) is proposed. The proposed parallel operating technique can increase the power rating of the system easily. Also, it provide three-phase connection function. The proposed technique does not separated master and slave system. Also, it does not use the separated synchronization line. Therefore, the PCS can supply continuous power even if one of the PCS breaks down. This technique is composed of a phase locked loop (PLL) control, droop control, current limit control and etc. Experimental result obtained on 2-kW prototype to verify the proposed technique.

Grid-Tied and Stand-Alone Operation of Distributed Generation Modules Aggregated by Cascaded Boost Converters

  • Noroozian, Reza;Gharehpetian, Gevorg;Abedi, Mehrdad;Mahmoodi, Mishel
    • Journal of Power Electronics
    • /
    • v.10 no.1
    • /
    • pp.97-105
    • /
    • 2010
  • This paper presents the modeling, control and simulation of an interconnection system (ICS) of cascaded distributed generation (DG) modules for both grid-tied and stand-alone operations. The overall configuration of the interconnection system is given. The interconnection system consists of a cascaded DC/DC boost converters and a DC/AC inverter. Detailed modeling of the interconnection system incorporating a cascaded architecture has not been considered in previous research. In this paper, suitable control systems for the cascaded architecture of power electronic converters in an interconnection system have been studied and modeled in detail. A novel control system for DC/DC boost converters is presented based on a droop voltage controller. Also, a novel control strategy for DC/AC inverters based on the average large signal model to control the aggregated DG modules under both grid-tied and stand-alone modes is demonstrated. Simulation results indicate the effectiveness of the proposed control systems.

OpenVSLAM-based Cooperative Mobile AR System Architecture (OpenVSLAM 기반의 협력형 모바일 SLAM 시스템 설계)

  • Kook, Joongjin
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.1
    • /
    • pp.136-141
    • /
    • 2022
  • In this paper, we designed, implemented, and verified the SLAM system that can be used on mobile devices. Mobile SLAM is composed of a stand-alone type that directly performs SLAM operation on a mobile device, and a mapping server type that additionally configures a mapping server based on FastAPI to perform SLAM operation on the server and transmits data for map visualization to a mobile device. The mobile SLAM system proposed in this paper is to mix the two types in order to make SLAM operation and map generation more efficient. The stand-alone type SLAM system was configured as an Android app by porting the OpenVSLAM library to the Unity engine, and the map generation and performance were evaluated on desktop PCs and mobile devices. The mobile SLAM system in this paper is an open source project, so it is expected to help develop AR contents based on SLAM in a mobile environment.

Agent-Based Distance Relaying Algorithm for Phase-to-Ground Faults (에이전트 환경에서의 1선지락 거리계전 알고리즘)

  • Hyun, Seung-Ho;Jin, Bu-Gun;Lee, Seung-Jae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.11
    • /
    • pp.1885-1891
    • /
    • 2007
  • This paper presents a distance relaying algorithm for phase-to-ground faults in transmission lines under Multi-Agent protection environment. In normal condition, a distance relay agent stores the latest states, e.g., voltage of source side, voltage of the opposite side and the loading conditions, etc., through communication between the agents. Once a fault occurs, the relay calculates the fault location using the knowledge about the states just before the fault happens. This stand-alone operation is to improve reliability under the fault condition at which the accuracy or time required for communication may not be guaranteed. The mathematical expression of fault location is derived through loop analysis, before hand, in the manner that both fault current from the opposite end and fault resistance are included implicitly so that their effects are minimized. The suggested algorithm is applied to a typical transmission system with two power sources on both ends to show its effectiveness.

A Voltage Regulation System for Independent Load Operation of Stand Alone Self-Excited Induction Generators

  • Kesler, Selami;Doser, Tayyip L.
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1869-1883
    • /
    • 2016
  • In recent years, some converter structures and analyzing methods for the voltage regulation of stand-alone self-excited induction generators (SEIGs) have been introduced. However, all of them are concerned with the three-phase voltage control of three-phase SEIGs or the single-phase voltage control of single-phase SEIGs for the operation of these machines under balanced load conditions. In this paper, each phase voltage is controlled separately through separated converters, which consist of a full-bridge diode rectifier and one-IGBT. For this purpose, the principle of the electronic load controllers supported by fuzzy logic is employed in the two-different proposed converter structures. While changing single phase consumer loads that are independent from each other, the output voltages of the generator are controlled independently by three-number of separated electronic load controllers (SELCs) in two different mode operations. The aim is to obtain a rated power from the SEIG via the switching of the dump loads to be the complement of consumer load variations. The transient and steady state behaviors of the whole system are investigated by simulation studies from the point of getting the design parameters, and experiments are carried out for validation of the results. The results illustrate that the proposed SELC system is capable of coping with independent consumer load variations to keep output voltage at a desired value for each phase. It is also available for unbalanced consumer load conditions. In addition, it is concluded that the proposed converter without a filter capacitor has less harmonics on the currents.

Seamless Transfer Method of BESS Connected by Engine Generator (엔진발전기와 연계된 BESS의 무순단 모드 전환 기법)

  • Shin, Eun-Suk;Kim, Hyun-Jun;Kim, Kyo-Min;Yu, Seung-Yeong;Han, Byung-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.12
    • /
    • pp.1709-1717
    • /
    • 2015
  • In remote islands PV (Photo Voltaic) panel with BESS (Battery Energy Storage System) supplies electric power to the customers in parallel operation with EG (Engine Generator) to save fuel consumption and to mitigate environmental load. BESS operates in voltage control mode when it supplies power to the load alone, while it operates in current control mode when it supplies power to the load in parallel with EG. This paper proposes a smooth mode change scheme from current control to voltage control of BESS by adding proper initial value to the integral part of voltage control, and a smooth mode change scheme from voltage control to current control by tracking the EG output voltage to the BESS output voltage using PLL (Phase-Locked Loop). The feasibility of proposed schemes was verified through computer simulations with PSCAD/EMTDC, and the feasibility of actual hardware system was verified by experiments with scaled prototype. It was confirmed that the proposed schemes offer a seamless operation in the stand-alone power system in remote islands.

A Study on the Comparison of the Stand-alone operation Characteristics and Matlab/Simulink Dynamic Model of PEMFC and PEMFC/SCB (고분자전해질 연료전지(PEMFC)와 PEMFC/SCB의 동적 Matlab/Simulink 모델링 및 독립운전특성에 관한 연구)

  • Hong, Pyo-Won;Cho, Jae-Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.2
    • /
    • pp.53-60
    • /
    • 2011
  • The available power generated from the FC power plant may not be sufficient to meet sustained load demand, peak demand or transient events. An supercapacitor bank(SCB) can supply a large burst of power, but it cannot store a significant amount of energy. The combined use of FC and SCB has the potential for the better energy efficiency, reducing the cost of FC technology and improved dynamic response. In this paper, A single PEMFC and PEMFC operated in parallel with a SC bank are presented, A new dynamic model of PEMFC system, the converter and controller has been developed for stand-alone applications. The simulation results are presented using Matlab/Simulink, and SimPowerSystems environments. It is confirmed that the results show a good performance and stable DC-link voltage for proposed dynamic and mathematical models developed for the combined FC/SCB.

Seamless Transfer of Single-Phase Utility Interactive Inverters with a Synchronized Output Regulation Strategy

  • Xiang, Ji;Ji, Feifan;Nian, Heng;Zhang, Junming;Deng, Hongqiao
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1821-1832
    • /
    • 2016
  • This study presents a strategy using the synchronized output regulation method (SOR) for controlling inverters operating in stand-alone and grid-connected modes. From the view point of networked dynamic systems, SOR involves nodes with outputs that are synchronized but also display a desirable wave shape. Under the SOR strategy, the inverter and grid are treated as two nodes that comprise a simple network. These two nodes work independently under the stand-alone mode. An intermediate mode, here is named the synchronization mode, is emphasized because the transition from the stand-alone mode to the grid-connected mode can be dealt as a standard SOR problem. In the grid-connected mode, the inverter operates in an independent way, in which the voltage reference changes for generalized synchronization where its output current satisfies the required power injection. Such a relatively independent design leads to a seamless transfer between operation modes. The closed-loop system is analyzed in the state space on the basis of the output regulation theory, which improves the robustness of the design. Simulations and experiments are performed to verify the proposed control strategy.