• Title/Summary/Keyword: Stand alone

Search Result 701, Processing Time 0.028 seconds

Comparative Study on Biomechanical Behavior of Various Cervical Stand-Alone Cage Designs (경추용 일체형 추간체 유합 보형재의 디자인 변화에 따른 생체역학적 효과 비교 연구)

  • Park, Kwang Min;Jung, Tae Gon;Jeong, Seung Jo;Lee, Sung Jae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.11
    • /
    • pp.943-950
    • /
    • 2016
  • The purpose of this study was to evaluate and compare by finite element analysis the biomechanical performance, in terms of cervical stand-alone cage screw insert angle (Type 3 - 5: 2 Screws) and screw arrangement (Type 6 and 7: 3 Screws / Type 8 and 9: 4 Screws), and the range of motion (ROM) of traditional anterior cervical discectomy of a fusion device (Type 1: Cage / Type 2: Cage + ACP). Our study suggests that the biomechanical behavior of a postoperative cervical spine could indeed be influenced by design features, such as screw angle and number of screws. In particular, ROM and the risk of subsidence were more sensitive during extension about type 5 (Insert Angle $20^{\circ}$). Our study also suggested that the number of screw asymmetries between up and down for type 6 and 7 could result in differences in the risk of screw fracture manifesting in different clinical aspects.

A Monitoring Unit for Lead Storage Batteries in Stand Alone PV Generation Systems (독립형 태양광 발전소의 연 축전지 모니터링장치 개발)

  • Moon, Chae-Joo;Kim, Tae-Gon;Chang, Young-Hag;Kjm, Eui-Sun;Lim, Jung-Min
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.2
    • /
    • pp.1-7
    • /
    • 2009
  • Use of the PV(photovoltaic) generation system is increased in such areas as remote mountain places or islands at which electrical energy is not serviced. The stand alone PV system is required the power storage products such as battery, fly wheel and super capacitor. Several lead storage batteries are connected in series to get high voltages. The life of lead storage battery is shortened when over charge or over discharge takes place. So, it is needed to control batteries not to be overcharged or be discharged deeply. Voltage of each battery was ignored in former control methods in which overall voltage was used to control charge or discharge battery. In this study, the charging and discharging voltage variations of sealed lead storage batteries with l2V/l.2A were investigated step by step experiments. The results of the test show that one should consider and specify the state of each battery to prevent overcharge or deep discharge. With the basis of the experiments, we designed a monitoring unit to monitor battery voltages simultaneously using micro-controller. The unit measures voltage of 20 batteries simultaneously and displays data on the color LCD monitor with curved line graph. It also sends data to PC using the RS232C communication port. The designed unit was adapted to stand alone PV system with 1kW capacity and lead storage batteries are connected to the PV generation system. The number of lead storage batteries was 10 in series and 12V/250Ah each. Resistive load with 3kW was used for discharging.

Integrated Simulation Model for Designing Distributed Energy Management System in Microgrid System (마이크로그리드시스템의 분산 에너지관리시스템 설계를 위한 통합시뮬레이션 모델 개발)

  • Cho, Jae-Hoon;Park, Sun-Hong;Lee, Dae-Jong;Cho, Young-Im;Chun, Myung-Geun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.21 no.1
    • /
    • pp.29-35
    • /
    • 2011
  • In this paper, an integrated simulation model for designing multi-agent system based DEMS (distributed energy management system) in stand-alone micro-grid system is proposed. In the design of the EMS(energy management system), the multi-agent based DEMS are more effective than conventional centralized EMS, but it is difficult to design the DEMS by general design tools for power system because of various states of a microgrid system during operation of stand-alone mode. Also, since performance test of the DEMS using a real system is inefficient, an integrated simulation model is required for designing an effective multi-agent system based DEMS. The proposed model consists of Matlab/SimPowerSystems based simulation model of the microgrid system and the Multi-agnet based DEMS designed by Matlab/StateFlow tool. In order to show the effect of the proposed model, the model outputs are analyzed for specified operation conditions.

The Impact to Technological Competitiveness of SMEs According to the Type of Subcontracting (대.중소기업간 하도급유형에 따른 중소기업의 기술경쟁력 영향 분석)

  • Park, Mun-Su;Lee, Hohyung
    • Journal of Information Technology and Architecture
    • /
    • v.10 no.1
    • /
    • pp.33-45
    • /
    • 2013
  • This study investigated how the relationship between subcontracting affects the SMEs technology in order to strengthen the competitiveness of SMEs. Depending on the trading characteristics and structural characteristics, SMEs are separated into four types that dependent, peripheral-type cooperative, stand-alone. The impacts to technological competitiveness were measured, depending on the type of SME. The results show that SMEs technology competitiveness associated companies type are cooperation and stand-alone. We had confirmed that stand-alone type has high competitiveness through the technical support policy.

Stationary Reference Frame Voltage Controller for Single Phase Grid Connected Inverter for Stand Alone Mode (계통 연계형 단상 인버터의 단독 운전 모드를 위한 정지좌표계 전압 제어기)

  • Hong, Chang-Pyo;Kim, Hag-Wone;Cho, Kwan-Yuhl;Lim, Byoung-Kuk
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.6
    • /
    • pp.517-525
    • /
    • 2015
  • A grid connected inverter must be operated as the main electricity source under an isolated condition caused by the grid problem. Conventionally, the dual loop controller is used for the grid inverter, and the controller is used for control under the stand-alone mode. Generally, the PI(Proportional - Integral) controller is highly efficient under a synchronous reference frame, and stable control can be available. However, in this synchronous frame-based control, high-quality DSP is required because many sinusoidal calculations are necessary. When the PI control is conducted under a stationary frame, the controller constructions are made simple so that they work even with a low-price micro controller. However, given the characteristics of the PI controller, it should be designed with the phase of reference voltage considered. Otherwise, the phase delay of the output voltage can occur. Although the current controller also has a higher bandwidth than the voltage controller, distortion of the voltage is difficult to avoid only by the rapid response of the PI controller, as a sudden load change can occur in the nonlinear load. In this study, a new control method that solves the voltage controller bandwidth problem and rapidly copes with it even in the nonlinear load situation is proposed. The validity of the proposed method is proved by simulation and experimental results.

Determining the Optimal Capacities of Distributed Generators Installed in A Stand-alone Microgrid Power System (독립형 마이크로그리드 내 분산전원별 최적용량 결정 방법)

  • Ko, Eun-Young;Baek, Ja-Hyun;Kang, Tae-Hyuk;Han, Dong-Hwa;Cho, Soo-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.2
    • /
    • pp.239-246
    • /
    • 2016
  • In recent years, the power demand has been increasing steadily and the occurrence of maximum power demand has been moving from the summer season to the winter season in Korea. And since the control of electric power supply and demand is more important under those situations, a micro-grid system began to emerge as a keyword for the sTable operation of electric power system. A micro-gird power system is composed of various kinds of distributed generators(DG) such as small diesel generator, wind turbine, photo-voltaic generator and energy storage system(ESS). This paper introduces a method to determine the optimal capacities of the distributed generators which are installed in a stand-alone type of microgrid power system based on the fundamental proportion of diesel generator. At first, the fundamental proportion of diesel generator will be determined by changing from 0 to 50 percent. And then we will optimize the capacities of renewable energy resources and ESS according to load patterns. Lastly, after recalculating the capacity of ESS with consideration for SOC constraints, the optimal capacities of distributed generators will be decided.

Diffusion-Weighted Imaging as a Stand-Alone Breast Imaging Modality (독립적 검사 방법으로서의 확산강조 자기공명영상검사)

  • Hee Jung Shin;Su Hyun Lee;Woo Kyung Moon
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.1
    • /
    • pp.29-48
    • /
    • 2021
  • Diffusion-weighted magnetic resonance imaging (DW MRI) is a fast unenhanced technique that shows promise as a stand-alone modality for cancer screening and characterization. Currently, DW MRI may have lower sensitivity than that of dynamic contrast-enhanced MRI as a standalone modality for breast cancer detection but superior to that of mammography, which may provide a useful alternative for supplemental screening. Standardized acquisition and interpretation of DW MRI can improve the image quality and reduce the variability of the results. Furthermore, high-resolution DW MRI, with advanced techniques and postprocessing, will facilitate better detection and characterization of subcentimeter cancers and reduce false-negatives and false-positives. Future results from ongoing prospective multicenter clinical trials using standardized and optimized protocols will facilitate the use of DW MRI as a stand-alone modality.

The the Effect on External Financing of Ownership Type in Case of Early-Stage Firms (창업초기기업의 외부자금조달에 대한 기업소유구조 간 비교연구)

  • Kang, Won
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.10 no.6
    • /
    • pp.47-57
    • /
    • 2015
  • This study examines whether successful stand-alone firms have more difficulties than the successful firms affiliated to business groups in external financing. The easiness of external financing is measured by investment-cashflow multiple. Controlling the effects on the multiple of the past business performances and the expectation of future business performances, we investigate how the ownership type affects the multiple. The empirical results show that, when cashflows are positive, the stand-alone firms exhibit higher investment-cashflow mupltiples. When cashflows are negative, however, the opposite is true, even though the statistical significance of the result is rather low. These results do not support the general idea that stand-alone firms must have more disadvantage than subsidiary firms in raising funds from outside. If member firms of business groups have no big trouble financing externally, then the above results imply that stand-alone firms do not either identify external financing as a major difficulty in running business. Thus, if the government seeks to formulate the selective policies supporting only the promising start-ups, instead of the general policies benefiting random start-ups, then the start-up financing policy should have a lower priority.

  • PDF

The "Standing Alone" Process of Divorced Single Fathers (한부모 이혼 남성의 홀로서기과정)

  • Rho, Jung-Ja;Kang, Ki-Jung
    • Journal of Family Resource Management and Policy Review
    • /
    • v.16 no.2
    • /
    • pp.145-163
    • /
    • 2012
  • The purpose of this study is to understand the process of "standing alone" in divorced single fathers on the basis of qualitative data collected through in-depth interviews with 10 divorced single fathers. Data were analyzed on the basis of grounded theory analysis in open coding, and 154 concepts, 39 sub-categories, and 14 categories were derived. According to the results of this study, the process phenomenon of divorced single fathers' standing alone was "the restraint and chaos of pain". This study could identify the consecutive process of four identified stages: marriage life's rupture, pain and chaos, deliberation and decision, and role adaption. In selective coding, the core category was "to pass through the restraint of pain and embrace children and stand alone". There were three types of standing alone: maintaining barely, enduring hopefully, and living initiatively. This study showed the necessity of social support and the basic data by type analysis through the process of standing alone. This study provided substantive knowledge generated through the voices of the persons concerned.

  • PDF

The Modified Fall Detection Algorithm based on YOLO-KCF for Elderly Living Alone Care (독거노인 케어를 위한 개선된 YOLO-KCF 기반 낙상감지 알고리즘)

  • Kang, Kyoung-Won;Park, Soo-Young
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.21 no.2
    • /
    • pp.86-91
    • /
    • 2020
  • As the number of elderly people living alone increases, the frequency of fall accidents is also increasing. Falls are a threat to the health of older adults and can reduce their ability to remain independent. To solve this problem, we need real-time technology to recognize and respond to the critical condition of the elderly living alone. Therefore, this paper proposes a modified fall detection algorithm based on YOLO-KCF that can check one of the emergency situations in real time for the elderly living alone. YOLO can detect not only the detection of objects, but also the behavior of objects, namely stand and fall. Therefore, this paper can detect fall using the ratio of change of boundary box between stand and falling situation, and this algorithm can improve the shortcomings of KCF.