• 제목/요약/키워드: Stance and Swing Phase Control

검색결과 36건 처리시간 0.029초

입각기.유각기 동시제어식 대퇴의지의 개발 (Development of a Stance and Swing Phase Control Transfemoral Prosthesis)

  • 김신기;김경훈;문무성;이순걸;백영남
    • 대한기계학회논문집A
    • /
    • 제25권4호
    • /
    • pp.685-694
    • /
    • 2001
  • In this study, a transfemoral prosthesis system of which both stance phase and swing phase are controllable has been developed for the recovery of the biomechanical function of the amputated leg. It consists of a 5 bar link mechanism, a hydraulic-rubber knee damper for stance phase control and a pneumatic cylinder controlled via a microprocessor for stance phase control. The mechanical characteristics of the knee damper which absorbs the impact energy generated at the heel contact were investigated. The characteristics of the pneumatic cylinder essential for the speed adaptation of the prosthesis during swing phase were also studied for its mechanical characteristics. The prosthesis was subject to the clinical tests, and the gait characteristics obtained were very close to those of normal subjects. The stance and swing controlled prosthesis that were developed in this study showed good stability during the stance phase and showed good controllability during the swing phase.

입각기와 유각기 제어 대퇴의지의 개발 (Development of a Stance & Swing Phase Control Transfemoral Prosthesis)

  • 김신기;김종권;홍정화;김경훈;문무성;이순걸;백영남
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집A
    • /
    • pp.504-509
    • /
    • 2000
  • In this study, a transfemoral prosthesis system of which stance phase and swing phase are controlled during walking has been developed for the recovery of the biomechanical function of the amputated leg. It consists of a 5 bar link mechanism, a hydraulic-rubber knee damper for stance phase control and a pneumatic cylinder controlled via a microprocessor for stance phase control. The mechanical characteristics and behaviour of the knee damper which absorbs the impact energy generated at the heel contact was investigated. The characteristics of the pneumatic cylinder essential for the speed adaptation of the prosthesis during swing phase was also studied for its mechanical characteristics. The prosthesis was subject to the clinical test ant the gait characteristics obtained were very close to those of normal. The stance and swing controlled prosthesis that were developed in this study showed good stability during the stance phase and showed good controllability during the swing phase.

  • PDF

골반안정화 운동프로그램이 엉치엉덩관절 통증을 동반한 만성요통환자의 통증과 엉덩관절에 미치는 영향 (The Effect of Pelvic Stability Exercise Program on Pain and Hip Joint of Patients with Chronic Low Back Pain involving Sacroiliac Joint Pain)

  • 강정일;최현
    • 디지털융복합연구
    • /
    • 제11권4호
    • /
    • pp.331-338
    • /
    • 2013
  • 본 연구는 엉치엉덩관절 통증을 동반한 만성 요통환자 52명을 대상으로 6주 간 골반운동프로그램 및 전통적 물리치료를 병행한 실험군 27명과 전통적 물리치료만을 중재한 대조군 25명을 무작위 임상 표본 추출 하였다. 두 군 모두 통증의 정도를 알아보는 오스웨스트리-요통장애지수검사와 보행 시 엉덩관절의 각도분석을 한 후, 집단별 실험 전과 실험 후의 오스웨스트리-요통장애지수검사와 보행 시 엉덩관절의 각도분석을 비교하여 골반안정화 운동프로그램이 엉치엉덩관절 통증을 동반한 만성요통환자의 통증과 엉덩관절에 미치는 영향을 알아보고자 하였다. 요통의 변화는 집단 내와 집단 간에서 모두 유의하게 감소되었음을 알 수 있었고, 엉덩관절 각도비교에서는 실험군내 좌측 엉덩관절에서 중간디딤기, 말기디딤기, 유각전기, 초기흔들기와 우측 엉덩관절의 중간디딤기, 말기디딤기, 유각전기, 초기흔들기에서 차이가 있었다. 대조군 내 좌측 엉덩관절에서는 중간디딤기, 말기디딤기, 초기흔들기와 우측 엉덩관절의 체중전달기, 중간디딤기, 말기흔들기, 유각전기에서 유의한 차이가 있었다. 따라서 골반안정화 운동프로그램이 통증을 포함한 요통기능장애수준에 효과적이고 보행 시 입각기와 유각기 동안 엉덩관절의 굽힘과 폄이 리듬 있게 이동하여 보행이 대칭적으로 자연스럽게 이동되는데 도움이 되는 것으로 나타났다.

파킨슨 환자의 멈춤 보행 시 하지 근전도 분석 (Analysis of Lower Extremity Muscle Activities in Parkinson's Patients for Improving to Stop Task)

  • 양창수;임비오
    • 한국운동역학회지
    • /
    • 제22권3호
    • /
    • pp.333-339
    • /
    • 2012
  • Freezing of gait is a severely problem in people with Parkinson's disease. The purpose of this study was to investigate the muscle activities of adductor longus, gluteus medius, gluteus maximus, biceps femoris, rectus femoris, gastrocnemius, and tibialis anterior using Noraxon 8 channels EMG system during stop task in patients with Parkinson's disease. Seven parkinson's patients and age matched normal participants were recruited in the study. Filtered EMG signals were rectified, smoothed and integrated. To control for the altered timing and magnitude of activity, iEMG was normalized for time and peak value. The results indicated that the patients with Parkinson showed decreased gait cycle, stance phase, swing phase time, swing phase time ratio and increased stance phase time ratio than normal participants. The patients with Parkinson showed decreased gastrocnemius muscle activity time ratio, while increased tibialis anterior muscle activity time ratio than normal participants. During stance phase before stop, the patients with Parkinson showed relatively lower average and peak iEMG in anterior tibialis and gastrocnemius muscle than normal participants. During swing phase before stop, the patients with Parkinson showed relatively higher average iEMG in gastrocnemius muscle than normal participants. During stop phase, the patients with Parkinson showed relatively lower average and peak iEMG in anterior tibialis and gastrocnemius muscle than normal participants.

회전기 및 착지기 분리 구동을 가능케 하는 새로운 무릎 보장구의 기구부 설계 (A Novel Kinematic Design of a Knee Orthosis to Allow Independent Actuations During Swing and Stance Phases)

  • 표상훈;김갑순;윤정원
    • 제어로봇시스템학회논문지
    • /
    • 제17권8호
    • /
    • pp.814-823
    • /
    • 2011
  • Nowadays many neurological diseases such as stroke and Parkinson diseases are continually increasing. Orthotic devices as well as exoskeletons have been widely developed for supporting movement assistance and therapy of patients. Robotic knee orthosis can compensate stiff-knee gait of the paralyzed limb and can provide patients consistent assistance at wearable environments. With keeping a robotic orthosis wearable, however, it is not easy to develop a compact and safe actuator with fast rotation and high torque for consistent supports of patients during walking. In this paper, we propose a novel kinematic model for a robotic knee orthosis to drive a knee joint with independent actuation during swing and stance phases, which can allow an actuator with fast rotation to control swing motions and an actuator with high torque to control stance motions, respectively. The suggested kinematic model is composed of a hamstring device with a slide-crank mechanism, a quadriceps device with five-bar/six-bar links, and a patella device for knee covering. The quadriceps device operates in five-bar links with 2-dof motions during swing phase and is changed to six-bar links during stance phase by the contact motion to the patella device. The hamstring device operates in a slider-crank mechanism for entire gait cycle. The kinematics and velocity/force relations are analyzed for the quadriceps and hamstring devices. Finally, the adequate actuators for the suggested kinematic model are designed based on normal gait requirements. The suggested kinematic model will allow a robotic knee orthosis to use compact and light actuators with full support during walking.

전자-기계식 클러치를 이용한 장하지 보조기용 무릎관절 자동 제어 장치의 개발 (Development of the Automatic Knee Joint Control System for a Knee-Ankle-Foot Orthosis Using an Electromechanical Clutch)

  • 이기원;강성재;김영호;조강희
    • 대한의용생체공학회:의공학회지
    • /
    • 제22권4호
    • /
    • pp.359-368
    • /
    • 2001
  • A new knee-ankle-foot-orthosis(KAFO) which uses an automatically-controlled electromechanical wrap spring clutch for the knee joint was developed in the present study. It was found that the output voltage from the foot switches of the developed KAFO was proportionally increased with respect to the applied load. The output voltage from the infrared sensor also decreased as the knee flexion angle increased. The knee joint system for the new KAFO weighs only 780g lighter than any other commercially available developed system. In addition, the solenoid reduces the reaction time for the automatic control of the knee joint. The static torque of the clutch was measured for three persons, and it satisfied the normal knee extension moment during the pre-swing. Three-dimensional gait analyses for three different gait patterns (normal gait, locked-knee gait, controlled-knee gait) from five normal subjects were conducted. Controlled-knee gait showed the maximum knee flexion angle of 40.56$\pm9.55^{\circ}$ and the maximum knee flexion moment of 0.20$\pm$0.07Nm/kg at similar periods in the normal gait. Our KAFO system satisfies both stability during stance phase and free knee flexion during the swing phase at the proper period during the gait cycle. Therefore, our KAFO system would be very useful in various low extremity orthotic applications.

  • PDF

Pelvic, Hip, and Knee Kinematics of Stair Climbing in People with Genu Varum

  • Chae, Yun Won;Park, Seol;Park, Ji Won
    • The Journal of Korean Physical Therapy
    • /
    • 제30권1호
    • /
    • pp.14-22
    • /
    • 2018
  • Purpose: This study examined the effects of the lower limb alignment on the pelvis, hip, and knee kinematics in people with genu varum during stair walking. Methods: Forty subjects were enrolled in this study. People who had intercondylar distance ${\geq}4cm$ were classified in the genu varum group, and people who had intercondylar distance <4cm and intermalleolar distance <4cm were placed in the control group. 3D motion analysis was used to collect the pelvis, hip, and knee kinematic data while subjects were walking stairs with three steps. Results: During stair ascent, the genu varum group had decreased pelvic lateral tilt and hip adduction at the early stance phase and decreased pelvic lateral tilt at the swing phase compared to the control group. At the same time, they had decreased minimal hip adduction ROM at the early stance and decreased maximum pelvic lateral tilt ROM and minimum hip rotation ROM at the swing phase. During stair descent, the genu varum group had decreased pelvic lateral tilt at the early stance and decreased pelvic lateral tilt and pelvic rotation at the swing phase. In addition, they had decreased pelvic frontal ROM during single limb support and increased knee sagittal ROM during the whole gait cycle. Conclusion: This study suggests that a genu varum deformity could affect the pelvis, hip and knee kinematics. In addition, the biomechanical risk factors that could result in the articular impairments by the excessive loads from lower limb malalignment were identified.

The Effects of Repetitive Transcranial Magnetic Stimulation on the Gait of Acute Stroke Patients

  • Ji, Sang-Goo;Kim, Myoung-Kwon
    • Journal of Magnetics
    • /
    • 제20권2호
    • /
    • pp.129-132
    • /
    • 2015
  • The aim of the present study was to examine whether repetitive transcranial magnetic stimulation (rTMS) can improve gait ability of acute stage stroke patients. This study was conducted with 39 subjects who were diagnosed as having a hemiparesis due to stroke. The experimental group included 20 subjects who underwent repetitive transcranial magnetic stimulation and the control group included 19 subjects who underwent sham therapy. The stroke patients in the experimental group underwent conventional rehabilitation therapy and rTMS was applied daily to the hotspot of the lesional hemisphere. The stroke patients in the control group underwent sham rTMS and conventional rehabilitation therapy. Participants in both groups received therapy five days per week for four weeks. Temporospatial gait characteristics, such as stance phase, swing phase, step length in affected side, velocity, and cadence, were assessed before and after the four week therapy period. A significant difference was observed in post-treatment gains for the step length in the affected side, velocity, and cadence between the experimental group and control group ( p < 0.05). However, no significant differences were observed between the two groups on stance phase and swing phase ( p > 0.05). We conclude that rTMS may be beneficial in improving the effects of acute stage stroke on gait ability.

유전자 알고리즘을 이용한 새로운 무릎 보장구의 최적 설계 (Optimal Design of a Novel Knee Orthosis using a Genetic Algorism)

  • 표상훈;윤정원
    • 제어로봇시스템학회논문지
    • /
    • 제17권10호
    • /
    • pp.1021-1028
    • /
    • 2011
  • The objective of this paper is to optimize the design parameters of a novel mechanism for a robotic knee orthosis. The feature of the proposed knee othosis is to drive a knee joint with independent actuation during swing and stance phases, which can allow an actuator with fast rotation to control swing motions and an actuator with high torque to control stance motions, respectively. The quadriceps device operates in five-bar links with 2-DOF motions during swing phase and is changed to six-bar links during stance phase by the contact motion to the patella device. The hamstring device operates in a slider-crank mechanism for entire gait cycle. The suggested kinematic model will allow a robotic knee orthosis to use compact and light actuators with full support during walking. However, the proposed orthosis must use additional linkages than a simple four-bar mechanism. To maximize the benefit of reducing the actuators power by using the developed kinematic design, it is necessary to minimize total weight of the device, while keeping necessary actuator performances of torques and angular velocities for support. In this paper, we use a SGA (Simple Genetic Algorithm) to minimize sum of total link lengths and motor power by reducing the weight of the novel knee orthosis. To find feasible parameters, kinematic constraints of the hamstring and quadriceps mechanisms have been applied to the algorithm. The proposed optimization scheme could reduce sum of total link lengths to half of the initial value. The proposed optimization scheme can be applied to reduce total weight of general multi-linkages while keeping necessary actuator specifications.

Effects of Action Observation Training Combied with Auditory Cueing on Gait Ability in Patients with Stroke: a Preliminary Pilot Study

  • Kim, Hyeong-Min;Son, Sung-Min;Ko, Yu-Min
    • The Journal of Korean Physical Therapy
    • /
    • 제34권3호
    • /
    • pp.98-103
    • /
    • 2022
  • Purpose: New therapeutic approaches have emerged to improve gait ability in patients with brain damage, such as action observation learning (AOT), auditory cueing, motor imagery etc. We attempted to investigate the effects of AOT with auditory cueing (AOTAC) on gait function in patients with stroke. Methods: The eighteen stroke patients with a unilateral hemiparesis were randomly divided into three groups; the AOTAC, AOT, and control groups. The AOTAC group (n=8) received training via observing a video that showed normal gait with sound of footsteps as an auditory cue; the AOT group (n=6) receive action observation without auditory stimulation; the control group (n=5) observed the landscape video image. Intervention time of three groups was 30 minutes per day, five times a week, for four weeks. Gait parameters, such as cadence, velocity, stride length, stance phase, and swing phase were collected in all patients before and after each training session. Results: Significant differences were observed among the three groups with respect to the parameters, such as cadence, velocity, stride length, and stance/swing phase. Post-hoc analysis indicated that the AOTAC group had a greater significant change in all of parameters, compared with the AOT and control groups. Conclusion: Our findings suggest that AOTAC may be an effective therapeutic approach to improve gait symmetry and function in patients with stroke. We believe that this effect is attributable to the change of cortical excitability on motor related to cortical areas.