• 제목/요약/키워드: Staircase phenomenon

검색결과 7건 처리시간 0.02초

수축과 활동전압의 Staircase 현상에 대한 Ca-전류 및 세포내 $Ca^{2+}$ 농도 변화의 영향 (Effects of the Changes in Ca-current and Intracellular Ca-concentration on the Contraction and Action Potential Staircase)

  • 박춘옥;서인석;호원경;엄융의;김우겸
    • The Korean Journal of Physiology
    • /
    • 제23권2호
    • /
    • pp.301-312
    • /
    • 1989
  • It well known that the magnitude of contraction and the shape of action potential depend upon the stimulation frequency and the duration of resting period (positive and negative staircase). Although the underlying mechanism of the staircase phenomenon is not fully understood, it has been suggested that staircase could be related to the intracllular $Ca^{2+}$ concentration. In order to elucidate the role of intracellular $Ca^{2+}$ on the contraction and action potential staircases, we examined the effects of 1 mM 4-aminopyridine (4-AP), 0.5 uM verapamil, 1 uM ryanodine, or reduction of extracellular Na concentration to 30% $(substituted\;by\;equimolar\;Li^+)$ in small atrial strips of the rabbit $(3{\times}10\;mm)$. The results obitained were as follows; 1) When the stimulation frequency was increased from 0.1 Hz to 2 Hz, positive staircase of the contraction and elevation of plateau level in action potential were found in control and the conditions of Na reduction and treatments of 4-AP, verapamil and ryanodine. 2) When stimulation frequency returned to 0.1 Hz from 1 min rest just after 2 Hz stimulation fer 1 min, the magnitudes of initial few contractions were larger than that of steady state contraction (post-rest potentiation) except, ryanodine or Na-reduction groups. 3) Negative staircase of contraction was developed in control and 4-AP group at post-rest 0.1 Hz stimulation and the plateau level of the action potential was decreased at the same time. But the reduction of contraction or the plateau level was much smaller in 4-AP group and than in control. From the above results it can be concluded that contraction and action potential staircase is dependent upon transmembrane $Ca^{2+}-current\;and\;Ca^{2+}$release from the SR.

  • PDF

다각도의 에지 정보를 이용한 디인터레이싱 (Deinterlacing Using Multi-Directional Edge Information)

  • 이동욱;강문봉
    • 융합신호처리학회논문지
    • /
    • 제11권2호
    • /
    • pp.92-96
    • /
    • 2010
  • 디인터레이싱 방식은 일반적으로 화면 간 디인터레이싱과 화면 내 디인터레이싱으로 나뉜다. 화면 내 디인터레이싱에서 가장 보편적인 방식은 라인카피와 라인별 평균값을 취하는 선형적인 방식이다. 또한 ELA(Edge Based Line Average), ELA를 변형시킨 방식 등이 에지를 이용한 디인터레이싱 방식들이다. 하지만 선형적 보간법은 에지 블러링이나 계단현상을 발생시키고, ELA나 변형된 ELA를 이용한 방식은 특정방향에지 정보가 부족해서 다양한 형태의 에지 부분에서의 디인터레이싱이 좋지 못하다. 본 논문은 7방향의 에지 방향 보간법과 수평방향의 에지라인을 고려한 화면 내 디인터레이싱 방식을 소개한다. 기존 방식에서 나타나던 오브젝트의 계단현상을 최대한 줄여줌으로써 보다 낳은 화질을 보인다.

DWT을 이용한 의료영상 압축 (Compression of Medical Images Using DWT)

  • 임재동;이상복
    • 한국방사선학회논문지
    • /
    • 제2권2호
    • /
    • pp.11-16
    • /
    • 2008
  • PACS를 구현할 때 가장 어려운 점은 데이터 총량이 방대하다는 것이다. 이러한 이유로 PACS에서는 대용량의 기억장치를 필요로 하고, 동시에 빠른 전송시간이 요구된다. 따라서 PACS에 저장하는 의료영상은 압축이 필요하다. Ingrid Daubechies와 Stephane Mallat 등에 의해 발표된 웨이브릿 변환은 푸리어 변환과 같이 기저 함수들의 집합으로 신호를 분해하는 방법이다. 본 논문에서는 실험 의료영상을 DWT 방법으로 압축하여 효용성을 평가하였다. 실험 결과 $512{\times}512{\times}2^8$ 크기의 입력영상을 4 레벨 DWT 후 저주파영역에 남아 있는 신호를 디스플레이 하는 것이 효율적임을 알 수 있었다. 4 레벨 DWT에 의한 영상의 압축비는 1:16로서 높은 압축비를 가지고 있었으며, 압축결과 압축비는 좋았으나 블록화 현상에 의해 영상에 계단현상이 나타나는 문제점이 있었다.

  • PDF

보정 이미지의 최 근접 좌표를 이용한 실시간 방사 왜곡 보정 하드웨어 설계 (A Hardware Design for Realtime Correction of a Barrel Distortion Using the Nearest Pixels on a Corrected Image)

  • 송남훈;이준환
    • 한국컴퓨터정보학회논문지
    • /
    • 제17권12호
    • /
    • pp.49-60
    • /
    • 2012
  • 본 논문은 보정 이미지에서 최 근접 좌표를 이용한 방사 왜곡 보정 하드웨어 구조를 제안한다. 기존 보간법과는 달리 보정 이미지에서 최근접한 좌표의 거리를 이용하기 때문에 이미지 전체 영역의 화질 향상과 함께 외각영역에서 발생하는 계단 현상을 해결할 수 있다. 그러나 양 선형 보간법을 적용한 기존 구조에서 추가되는 연산으로 인해 하드웨어 크기가 증가한다. 이를 해결하기 위해 룩 업 테이블 구조를 제안하고, 코르딕 알고리즘을 적용한다. Design compiler를 이용하여 합성한 결과 보간법의 모든 과정을 하드웨어로 구현한 구조는 기존 구조에 비해 처리량이 높고, 차량용 후방 카메라의 경우 룩 업 테이블과 하드웨어를 함께 사용한 구조는 모든 과정을 하드웨어로 구현한 구조보다 하드웨어 크기를 10% 줄일 수 있다.

적출 유두근에서 근육길이에 따른 계단현상 및 칼슘 수축력의 변화 (Length-dependent Staircase Phenomenon and Calcium Inotropisn in Isolated Rabbit Papillary Muscle)

  • 김기환;엄융의;남기용
    • The Korean Journal of Physiology
    • /
    • 제14권2호
    • /
    • pp.7-16
    • /
    • 1980
  • The effects of various inotropic interventions on the shape of the steady state length tension relation and the length-dependent activation process in cardiac muscle were studied. The influence of inotropic interventions upon the action potential was also observed. The range of varying muscle length was from the optimal length$(l_{max})$, where the active tension production is maximal, to 0.85 $l_{max}$. Changes in stimulus frequency or in external bathing Ca concentration constituted the inotropic interventions in this experiment. The papillary muscles were isolated from the rabbit right ventricles and perfused with $HCO-_3\;-buffered$ normal Tyrode solution which was aerated with $3%\;CO_2-97%\;O_2$ mixed gas and kept at $35^{\circ}C$. Resting Passive tension at $l_{max}$ was approximately 30% of the total tension and appeared from the muscle length of 0.90 $l_{max}$. The effect of stimulus frequency on the steady state level of developed tension was: As the stimulus frequency was increased from 0.1 to 0.5 Hz, there was little change in developed tension. As the frequency was increased further, to a value of about 3 Hz, tension increased steeply. Further increase of the frequency to 5 Hz had little additional effect on the developed tension. The length-tension curves for isometric peak tension became more steeper with the degree of potentiation by inotropic interventions. The relative steepness of the normalized length-tension curves where tension production was expressed as a percentage of maximal tension developed at $l_{max}$, varied inversely with the level of inotropic state and these curves were not superimposable one another. Thus at the stimulus frequency of 2 Hz or at the external Ca concentration of 8 mM, the relative decline in the developed tension for a given change in muscle length was considerably less than the decline observed at the frequency of 0.5 Hz or at the concentration of 2 mM Ca. Action potential duration was prolonged significantly as the frequency increased from 0.2 to 2 Hz, and this change in action potential duration was not observable on the changes in muscle length. There was a tendency of the hyperpolarization of membrane potential when the muscle length was shortened from $l_{max}$ to 0.95 $l_{max}$. These results support the hypothesis that there is a length-dependence of the activation process.

  • PDF

등록문화재 제233호 '공주 중학동 구 선교사가옥'의 유래와 보존현황 (Origin and Preservation Status of the 'Gongju Junghakdong Old Missionary House', the Registered Cultural Property No. 233)

  • 서만철;김성배
    • 보존과학회지
    • /
    • 제34권1호
    • /
    • pp.11-21
    • /
    • 2018
  • 등록문화재 제233호 '공주 중학동 구 선교사 가옥'의 유래와 보존현황에 관한 연구결과 건축연대는 1921년 10월 23일이 합당하며 일제 강점기 말기 최후 거주자는 그동안 Amendt 선교사로 알려져 왔으나, 1939년 작성된 Williams 선교사의 편지 및 새로운 증언에 의해 Alice Sharp 선교사가 1939년 은퇴시까지 사용하였던 건물로서 독신여선교사들의 주거는 물론 여학교역할도 하였던 건물로 밝혀졌다. 따라서 이 문화재의 명칭도 '공주 여선교사 기념관'으로 변경하는 것이 바람직하다. 본 문화재의 내 외부 보존현황 조사 결과 건물 벽체의 기울기에는 이상이 없으나 내부 목재상태가 상당부분 열화되어 있어 안전진단 후 전체적인 보수가 필요한 상황으로 판단된다. 특히, 창호시설의 경우 본래의 상하 미닫이 창호로 복원할 필요가 있으며, 건물의 남서측 계단과 데크 및 우물의 원형복원이 필요한 것으로 판단된다. 아울러 문화재의 하부지반의 안전성에 관한 지반 비파괴진단결과 이 선교유적이 2~5 m 두께의 불균등한 표토층 위에 건축되었으며 표토층과 그 하부의 풍화암과의 경계면이 지형경사 방향으로 기울어져 있는 현상이 발견되고 있다. 이러한 현상은 우기에 지반의 함수비가 증가하면 지반의 지지력이 저하되는 바 부등침하발생 가능성이 있으며, 특히 집중호우가 발생한다면 산사태를 초래할 가능성이 있다. 따라서 본 건물 부지의 남서단 경계부에 석축시설을 설치하는 것이 바람직하며 신속한 배수가 되도록 배수시설 설치가 필요하다.

IoT기반 원격환자모니터링을 위한 생체신호 측정 알고리즘 설계 및 구현 (Design and Implementation of Biological Signal Measurement Algorithm for Remote Patient Monitoring based on IoT)

  • 정애란;유용민;이상준
    • 예술인문사회 융합 멀티미디어 논문지
    • /
    • 제8권6호
    • /
    • pp.957-966
    • /
    • 2018
  • 최근 들어 고령화 및 1인 가구 증가로 인해 IoT기반 원격환자모니터링에 대한 요구가 증대되고 있다. 본 논문에서는 원격환자모니터링을 위한 다중의 IR-UWB레이더를 이용한 비접촉식 생체신호측정시스템을 제안하였다. 기존에는 생체신호처리를 위해 배경차분알고리즘을 적용하였으나, 전압노이즈, 계단현상 등의 에러 발생을 없애고자 다중 배경차분 알고리즘을 적용하였다. 다중배경차분알고리즘은 이전 클러터와 현재 클러터의 변화량을 계산하여 신호를 추출하며, 본 연구에서는 SVD알고리즘을 이용하였다. 개선된 다중배경차분알고리즘을 생체신호측정에 응용하여 고속 푸리에 변환을 통해 호흡수를 계산하였다. 제안한 IR-UWB레이더를 이용한 시스템 및 다중배경차분알고리즘의 검증을 위해 호흡수 측정을 진행하였다. Neulog사의 부착형 공기압착식 호흡측정기를 대조군으로 실험한 결과 97.36%의 정밀도를 확보함으로서 본 연구의 타당성을 검증하였다. 구현된 알고리즘은 기존의 접촉식 웨어러블 방식의 불편함을 개선하였다.