• Title/Summary/Keyword: Stainless steel ligature

Search Result 9, Processing Time 0.023 seconds

COMPARISON OF THE FRICTIONAL RESISTANCE BETWEEN ORTHODONTIC BRACKET & ARCHWIRE (교정용 BRACKET과 ARCHWIRE 사이의 마찰저항에 대한 비교연구)

  • Sung, Hyun Mee;Park, Young Chel
    • The korean journal of orthodontics
    • /
    • v.21 no.3
    • /
    • pp.543-560
    • /
    • 1991
  • Practitioners are aware of the presence of friction between bracket system and archwire during sliding movement of teeth. Clinically a mesiodistally applied force must exceed the frictional force to produce a tooth movement. The objective of this study were to determine, on a dry condition, changes in magnitude of friction with respect to load, 3rd order inclination (Torque), archwire materials and ligature type. Three wire alloys (Stainless Steel, TMA, NiTi) in two wire sizes (.016, .016x, .022 inch) were examined respect to two bracket system (Straight, Standard), and two ligature type (Metal, Plastic ligature) at three levels of load (100g, 150g, 200g). The results were as follows; 1. Frictional resistance was found to increase with increasing load for S.S., TMA, NiTi. 2. The straight bracket system was exhibited more frictional force than standard bracket system for .016x, .022 S.S. tightly ligated metal ligature. But, torque difference did not increase friction for loose metal ligature & plastic ligature. 3. Regardless of the ligature type, torque and load, stainless steel wire sliding against stainless steel exhibited the lowest friction, and TMA sliding against stainless steel exhibited the highest friction. 4. The loose stainless steel ligature generated lower frictional resistance than plastic ligature in all experimental groups. 5. The following factors affected friction in decreasing order; wire material ligature type, and load.

  • PDF

THE EFFECT OF LIGATION METHOD ON THE FRICTIONAL FORGE BETWEEN ORTHODONTIC BRACKET AND ARCHWIRE (결찰양식이 교정용 브라켓과 교정선 사이의 마찰력에 미치는 영향)

  • Shin, Hyun-Jeong;Kwon, Oh-Won;Kim, Kyo-Han
    • The korean journal of orthodontics
    • /
    • v.28 no.5 s.70
    • /
    • pp.813-823
    • /
    • 1998
  • The frictional force has been considered as an harmful factor in an active unit where tooth movement occurs, but as an advantageous factor in anchor unit that resist tooth movement. That is, efficient tooth movement is planned by using ligation methods that have low levels of bracket-wire frictional force and the anchorage control can be achieved by using ligation methods that have high levels of bracket-wire frictional force that result in binding of the bracket accompanied by little or no tooth movement. The purpose of this study was to evaluate the frictional force generated between bracket and wire in accordance with the methods of ligation, the material of ligation and the passage of time under artificial saliva. Tested were 0.017x0.022 inch stainless steel wires in standard edgewise twin brackets for upper central incisors in a 0.018-inch slot. The wires were ligated into the brackets with elastomeric modules and stainless steel ligatures. Whole tie, half tie, twisting tie and double overlay tie were done with elastomeric modules. With 0.009-inch stainless steel ligature whole tie and half tie were done by needle holder and whole tie by ligature tying plier. With 0.012-inch stainless steel ligature whole ties were done by needle holder. Whole tie groups of elastomeric module were kept in artificial saliva bath at $37^{\circ}C$ for 28 days. The frictional force was recorded by means of an Instron universial testing instrument (4202 INSTRON, Instron Co., U.S.A.) at initial, 7, 14, 21, and 28 days. The results for ligated samples in a simulated oral environment revealed the fellowing : ${\cdot}$In elastomeric module whole tie, 28 days group was significantly greater mean static frictional force than any other group but there were no significant differences among any other group (p>0.05). ${\cdot}$Elastomeric module twisting ties were significantly greater mean static frictional forces than any other ligation method but there were no significant differences between twisting tie and double overlay tie (p>0.05). Twisting tie, double overlay tie, whole tie, half tie showed differences in decreasing order. ${\cdot}$Stainless steel half tie produced lower mean static frictional force than whole tie, ligation by ligature tying plier produced greater mean static frictional force than by needle holder and ligation with 0.012-inch stainless steel ligature produced greater mean static frictional force than with 0.009-inch stainless steel ligature (p<0.05). ${\cdot}$There were no significant differences between the mean static frictional forces of elastomeric whole tie and stainless steel whole tie (p>0.05).

  • PDF

FRICTIONAL FORCES BETWEEN ORTHODONTIC WIRE AND BRACKET UNDER ARTIFICIAL SALIVA (인공타액하에서 교정선과 Bracket간의 마찰력에 대한 연구)

  • Ko, Jeong-Seok;Yang, Kyu-Ho
    • The korean journal of orthodontics
    • /
    • v.18 no.1 s.25
    • /
    • pp.55-63
    • /
    • 1988
  • It has been suggested that the frictional force between bracket and arch wire may impede the tooth movement. The present study was aimed to compare and analyze the effect of wire size, type of ligation, and duration of ligation on the magnitude of frictional force between cobalt chromium wire and stainless steel bracket under the artificial saliva. The results were as follows: 1. Type of ligation and size of wire were the main influencing factor on the level of friction. 2. Stainless steel ligature generated higher frictional forces than elastomeric module. 3. The rectangular wire consistently exhibited more frictional force values than round wires, while there was no significant difference between frictional forces of round wires. 4. In elastic ligature, frictional force decreased with time. 5. Artificial saliva had no significant influence on the frictional force between cobalt chromium wire and bracket.

  • PDF

Changes in frictional resistance between stainless steel bracket and various orthodontic wires according to a change in moment (모멘트 변화에 따른 브라켓과 교정용 선재 사이의 마찰력 변화)

  • Jeong, Hye-Jin;Kim, Kwang-Won;Lim, Sung-Hoon
    • The korean journal of orthodontics
    • /
    • v.37 no.2 s.121
    • /
    • pp.137-149
    • /
    • 2007
  • Objective: The purpose of this study was to compare changes in frictional resistance between the bracket and wire under dry and wet conditions according to a change in moment. Methods: A stainless steel bracket of $0.022"{\times}0.028"$ slot, and $0.019"{\times}0.025"$ stainless steel, beta-titanium, and nickel-titanium wires were used. A 10 mm length lever was attached to the test (sliding) brackets to generate a moment. The experimental model was designed to allow tipping until contacts were established between the wire and the mesiodistal edges of the bracket slot. The moment was generated by suspending a 100 g or 200 g weight on the end of the lever. The moments applied were $1000g{\cdot}mm\;(100g{\times}10mm)\;and\;2000g{\cdot}mm\;(200g{\times}10mm)$. The test brackets were ligated with elastomeric ligature for a constant ligation force and the fixed brackets were ligated with stainless steel ligature. Brackets were moved along the wire by means of an universal testing machine, and maximum frictional resistances were recorded. Results: Stainless steel wire showed least frictional resistance and there was no significant difference between beta-titanium and nickel-titanium except at $2000g{\cdot}mm$ moment in wet conditions. Frictional resistance of all wires increased as the moment increased from $1000g{\cdot}mm\;to\;2000g{\cdot}mm$. Under wet conditions, the frictional resistance of stainless steel wires increased in both $1000g{\cdot}mm\;and\;2000g{\cdot}mm$ moment conditions, but frictional resistance of nickel-titanium and beta-titanium increased only in $2000g{\cdot}mm$ conditions. Conclusion: These results indicated that various conditions influence on frictional resistance. Therefore, laboratory studies of frictional resistance should simulate clinical situation.

AN EXPERIMENTAL STUDY ON CHANGES OF ORTHODONTIC WIRES AFTER ELECTROPOLISHING (전해연마후 교정선의 변화에 관한 실험적 연구)

  • Lee, Jai-Chul;Kim, Jong-Chul
    • The korean journal of orthodontics
    • /
    • v.22 no.4 s.39
    • /
    • pp.823-836
    • /
    • 1992
  • Guiding a tooth along an arch wire results in a counteracting frictional force among arch wires, bracket and ligature. This frictional forces should be eliminated or minimized when orthodontic teeth movement is being planned. The purpose of this study was to evaluate the changes of width, cross-sectional forms and surface morphologies of stainless steel wire and $Elgiloy^{\circledR}$ wire after electropolising. Experimental variables included in this experiment were arch wire materials, current, electrolyte temperature and polishing time. Wire widths were measured by micrometer and cross-sectional forms and surface morphologies were examined with optical microscope and scanning electron microcope. The results were as follows: 1. The mean and standard deviation of widths of stainless steel wire and $Elgiloy^{\circledR}$ wire varying polishing time with condition of $249A/dm^2$ and $20^{\circ}C,\;249A/dm^2$ and, $332A/dm^2$ and $20^{\circ}C$ and $332A/dm^2$ and $250^{\circ}C$ were obtained. 2. With increasing polishing time, the widths of stainless steel wire and $Elgiloy^{\circledR}$ wire became decreased proportionally 3. The changes of widths of stainless steel wire and $Elgiloy^{\circledR}$ wire were statistically insignificant between $20^{\circ}C$ group and $25^{\circ}C$ group, but significant between $249A/dm^2$ group and $332A/dm^2$ group. 4 The cross-sectional forms of wire after electropolishing were not changed in stainless steel wire, and while it were changed to rounded corners in $Elgiloy^{\circledR}$ wire. 5. The surface morphologies of wire after electropolishing were scratch-absent and more smoothened both in stainless steel wire and $Elgiloy^{\circledR}$ wire.

  • PDF

A COMPARATIVE STUDY ON THE PHYSICAL PROPERTIES OF ORTHODONTIC PLIERS ACCORDING TO TYPES OF STERILIZATION (멸균 방법에 따른 교정용 플라이어의 물성 변화에 대한 비교 연구)

  • Cho, Il-Je;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.28 no.2 s.67
    • /
    • pp.329-341
    • /
    • 1998
  • Sterilization has received much attention in orthodontic practices over the past several years. The present study was undertaken to investigate the effects of sterilization on the physical properties of orthodontic pliers-AEZ, Unitek, and Dentronix ligature cutters. This study was designed to examine the tips of ligature cutters before and after 200 and 400 sterilization cycles using the Bowmar RHT-1000, the Dentronix DDS-5000, and the Eschmann SES-2000. The tip surface and the fracture surface were observed with a scanning electron microscope. The microstructure was observed with an optical microscope. The hardness test was carried out with the mic개-Vickers hardness tester and the Rockwell C Scale hardness tester. The chemical composition was analyzed by energy dispersive X-ray spectrometer. The results of this study were as follows : 1. The number and the size of corrosion products on the tip surface and the proportion of cleavage planes in fractured specimen increased, but the hardness of the tip decreased in proportion to sterilization cycles. From these observations, it was considered that mechanical properities decreased in proportion to sterilization cycles. 2. The number and the size of chromium carbides increased in proportion to sterilization cycles. Coarse microstructure decreased mechanical properities. 3. The AEZ and Unitek ligature cutters were Fe-Cr stainless steels, but the Dentronix ligature cutter was Co-Cr alloy. There were many differences among manufactures, but the chemical composition was .not changed after sterilization cycles. 4. The tip edge of ligature cutter used in a clinic revealed microcracks with the SEM observation. Clinical experience confirmed that ligature cutters were gradually degraded by sterilization.

  • PDF

A STUDY ON THE CHANCES OF FRICTIONAL FORCE BETWEEN BRACKET AND ORTHODONTIC WIRE WITH TIME IN ARTIFICIAL SALIVA (시간경과에 따른 교정용 bracket과 교정선 사이의 마찰력 변화에 관한 연구)

  • Kwak, Chun;Kim, Jim-Bom;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.23 no.2 s.41
    • /
    • pp.283-294
    • /
    • 1993
  • The friction of orthodontic appliances is recogonized to be detrimental to tooth movement. The purpose of this study was to determine the magnitude of frictional force changes between bracket$(018'\times025'\;solt)$ and orthodontic wires(stainless steel, cobalt-chromium, and $\beta-titanium$, $017'\times0.25'$ rectangular) with time. The wire was secured in the bracket slot with a elastomeric ligature. Frictional forces were measured by universal testing machine. The following conclusions were obtained. 1. The frictional forces under dry condition were greater than those in saliva. 2. The frictional forces produced by cobalt-chromium wire were less than those generated by stainless steel and $\beta-titanium$ wire. 3. The frictional forces increased progressively with time, and the amount of increase on first two weeks was greater than on last two weeks. 4. The change of frictional force under dry condition was greater than in artificial saliva.

  • PDF

Effect of different combinations of bracket, archwire and ligature on resistance to sliding and axial rotational control during the first stage of orthodontic treatment: An in-vitro study

  • Chen, Huizhong;Han, Bing;Xu, Tianmin
    • The korean journal of orthodontics
    • /
    • v.49 no.1
    • /
    • pp.21-31
    • /
    • 2019
  • Objective: This study was performed to explore the effect of different bracket, archwire, and ligature combinations on resistance to sliding (RS) and rotational control in first-order angulation. Methods: Three types of brackets (multi-level low friction [MLF], self-ligating, and conventional brackets) coupled with four nickel-titanium archwires (0.012, 0.014, 0.016, and 0.018-inch diameter) and two stainless steel ligatures (0.20 and 0.25 mm) were tested in different first-order angulations ($0^{\circ}$, $2^{\circ}$, $4^{\circ}$, $6^{\circ}$, $8^{\circ}$, $10^{\circ}$, $15^{\circ}$, $20^{\circ}$) by using an Instron universal mechanical machine in the dry state at room temperature. RS value was evaluated and compared by one-way ANOVA. Results: Under the same angulation, the RS values showed the following order: conventional brackets > MLF brackets > self-ligating brackets. The RS was the highest for conventional brackets and showed a tendency to increase. The RS for MLF brackets coupled with thinner archwires and ligatures showed a similar tendency as the RS for the self-ligating bracket. In contrast, the RS for MLF brackets coupled with thicker archwires and ligatures increased like that for conventional brackets. MLF brackets showed the greatest range of critical contact angles in first-order angulation. Conclusions: The RS in first-order angulation is influenced by bracket design, archwire, and ligature dimension. In comparison with self-ligating and conventional brackets, MLF brackets could express low friction and rotational control with their greater range of critical contact angles.

A comparative study of frictional forces according to orthodontic wires and ligation method under dry and wet conditions (교정선의 종류, 결찰방법, 타액의 유무에 따른 마찰력의 비교연구)

  • Lee, Jin-Woo;Cha, Kyung-Suk;Han, Jung-Suk
    • The korean journal of orthodontics
    • /
    • v.31 no.2 s.85
    • /
    • pp.271-281
    • /
    • 2001
  • The Purpose of this study was fourfold - to evaluate the general laws of friction applied to orthodontic conditions, to compare archwire materials under these controlled conditions, to compare ligation method, and to measure the effect of the artificial saliva on friction with these materials Three wire alloys (Cobalt-chromium, Nickel-titanium, Beta-titanium) in two size wires (.016" , .016" ${\times}$.022" ) were examined respect to the bracket (.018" ${\times}$.025" standard), and two ligature material (stainless steel, elastomeric) in dry and wet conditions The results were as follows, 1. The order of frictional force against alloy materials was Co-Cr (lowest), Ni-Ti, and ${\beta}$-Ti(highest) - with the exception of elastomeric ligation under wet conditions. 2. S.S. ligation gave rise to significantly greater friction than elastomeric ligation did. 3. Testing in the presence of saliva, rather than in dry conditions, decreased the frictional force for S.S. ligation with .016" Co-Cr, Ni-Ti, ${\beta}$-Ti. but, increased the frictional force for S.S. ligation with .016" ${\times}$ .022" Co-Cr, Ni-Ti, ${\beta}$-Ti. 4. .016" ${\times}$.022 " wire generated more friction than .016" wire.

  • PDF