• Title/Summary/Keyword: Staggered V-Shaped Rib

Search Result 3, Processing Time 0.017 seconds

Numerical Simulation of Flow and Heat Transfer in Cooling Channel with a Staggered V-shaped Rib (엇갈린 V-형 리브가 부착된 냉각유로에서의 열유동 수치해석)

  • Myong, Hyon-Kook;Kim, Kwang-Yong
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2448-2453
    • /
    • 2008
  • The present study numerically investigates the flow and heat transfer characteristics of rib-induced secondary flow in a cooling channel with staggered V-shaped ribs, extruded on both walls. The rib-height-to-hydraulic diameter ration (h/$D_h$) is 0.17; the rib pitch-to-height ratio (p/h) equals 2.8; the Reynolds number is 50,000. Shear stress transport (SST) turbulence model is used as a turbulence closure. The present results are compared with those for a continuous V-shaped rib. Computational results show that, for average heat transfer rate the staggered V-shaped rib gives about 2.5 times higher values than the continuous V-shaped rib, while, for the streamwise pressure drop the former gives about 5 times higher values than the latter. Consequently, for the thermal performances, based on the equal pumping power condition, the staggered one gives about 2 times higher values than the continuous one. Also, for the staggered V-shaped rib, complex secondary flow patterns are generated in the duct due to the snaking flow in the streamwise direction, and more uniform heat transfer distributions are obtained.

  • PDF

NUMERICAL SIMULATION OF FLOW AND HEAT TRANSFER IN COOLING CHANNEL WITH A STAGGERED V-SHAPED RIB (엇갈린 V-형 리브가 부착된 냉각유로에서의 열유동 수치해석)

  • Myong, H.K.;Kim, K.Y.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03a
    • /
    • pp.125-130
    • /
    • 2008
  • The present study numerically simulates the flow and heat transfer characteristics of rib-induced secondary flow in a cooling channel with staggered V-shaped ribs, extruded on both walls. The rib pitch-to-height ratio (p/h) varies from 2.8 to 10 with the rib-height-to-hydraulic diameter ration ($h/D_h$) of 0.07 and the Reynolds number of 50,000. Shear stress transport (SST) turbulence model is used as a turbulence model. Computational results show that complex secondary flow patterns are generated in the duct due to the snaking flow in the streamwise direction for all tested cases. In the range of p/h=5 to 10 the staggered V-shaped rib gives about 3 times higher heat transfer augmentation than the reference smooth channel with high heat transfer on both front side and the area around the leading edge of the ribs, while the former cases give about 2.5 times higher streamwise pressure drop than the latter ones. Consequently, for the thermal performances, based on the equal pumping power condition, the staggered ones give about 2 times higher values than the latter ones with more uniform heat transfer distribution.

  • PDF

NUMERICAL SIMULATION OF FLOW AND HEAT TRANSFER IN A COOLING CHANNEL WITH STAGGERED V-SHAPED RIBS (엇갈린 V-형 리브가 부착된 냉각유로에서의 열유동 수치해석)

  • Myong, H.K.;Kim, K.Y.
    • Journal of computational fluids engineering
    • /
    • v.13 no.4
    • /
    • pp.107-113
    • /
    • 2008
  • The present study numerically simulates the flow and heat transfer characteristics of rib-induced secondary flow in a square cooling channel with staggered V-shaped ribs, extruded on both walls. The rib pitch-to-height ratio (p/h) varies from 2.8 to 10 with the rib-height-to-hydraulic diameter ration (h/$D_h$)of 0.07 and the Reynolds number of 50,000. Shear stress transport (SST) turbulence model is used as a turbulence model. Computational results show that complex secondary flow patterns are generated in the channel due to the snaking flow in the streamwise direction for all tested cases. In the range of p/h=5 to 10 the staggered V-shaped rib gives about 3 times higher heat transfer augmentation than the reference smooth pipe with high heat transfer on both front side and the area around the leading edge of the ribs, while the former cases give about 18 times higher streamwise pressure drop than the latter ones. However, for the thermal performances, based on the equal pumping power condition, the case of p/h=2.8 gives the best result among three cases, mainly due to relatively low streamwise pressure drop, although it gives relatively low heat transfer augmentation.