• Title/Summary/Keyword: Staggered Array

Search Result 41, Processing Time 0.021 seconds

Effects of fin pitch and array of the frost laver growth on extended surface of a heat exchanger (열교환기 표면에서의 서리층 성장에 대한 휜 피치와 배열의 영향)

  • Yang, Dong-Keun;Lee, Kwan-Soo
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1461-1466
    • /
    • 2003
  • This paper presents the effects of the fin array and pitch on the frost layer growth of a heat exchanger. The numerical results are compared with experimental data of a cold plate to validate the present model, and agree well with experimental data within a maximum error of 8%. The characteristics of the frost formation on staggered fin array are somewhat different from those of in-line array. The frost layer at the first fin of the in-line array grows rapidly, compared to second fin, whereas the difference of the frost layer growth between the fins of the staggered array is small. For fin pitch below 10 mm, the frost layer growth of second fin in the staggered array is affected by that of first fin. The frost layer growth and heat transfer of single fin deteriorate with decreasing fin pitch regardless of fin array, however, the thermal performance of a heat exchanger, considering increase of heat surface area, becomes better.

  • PDF

Effects of Fin Pitch and Array on the Frost Layer Growth on the Extended Surface of a Heat Exchanger (열교환기 표면에서의 서리층 성장에 대한 휜 피치와 배열의 영향)

  • 양동근;이관수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.9
    • /
    • pp.711-717
    • /
    • 2003
  • This paper presents the effects of the fin array and pitch on the frost layer growth of a heat exchanger. The numerical results are compared with experimental data of a cold plate to validate the present model, and agree well with experimental data within a maximum error of 8%. The frost behaviors of the staggered fin array are somewhat different from those of in-line array. The frost layer formed on the first fin of the in-line array grows rapidly, compared to second fin, whereas the difference of the frost layer growth between the fins of the staggered array is small. For fin pitch below 10 m, the frost layer growth of second fin in the staggered array is affected by that of first fin. The thickness of the frost layer and heat transfer of single fin are reduced with decreasing fin pitch regardless of fin array. However, the thermal performance of a heat exchanger is enhanced due to the increase of heat transfer surface area.

Flow and Heat Transfer Characteristics due to Staggered Arrangement of Heat Pipes in Channels with Heat Pipes and Fins (휜-히트파이프로 구성된 채널에서 히트파이프의 엇갈림배열에 따른 유동 및 열전달 특성)

  • 김성훈;진윤근;김철주
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.11
    • /
    • pp.871-879
    • /
    • 2002
  • The characteristics of flow and heat transfer in the heat exchanger of heat pipes with fins have been studied numerically for cooling enhancement of electronic components of KTX (Korea Train eXpress). Numerical analysis and methodology have been conformed by comparing the experimental results for inlined array of heat pipes. The staggered arrangement of heat pipes has been proposed in order to achieve heat transfer enhancement. As results, the geometry change to the staggered array is conformed to increase the heat transfer of the system accompanied by an increase of pressure drop. The current results of friction factor and Colburn j factor are presented in terms of Reynolds number and staggered distance, and are expected to use for design and manufacture of such a system.

A Numerical Study on the Effect of Fin Pitch and Fin Array on the Heat Transfer Performance of a Pre-heater (휜의 피치 및 배열 방식에 따른 프리히터의 전열 성능에 관한 연구)

  • Yoo, Ji Hoon;Kim, Kuisoon
    • The KSFM Journal of Fluid Machinery
    • /
    • v.16 no.6
    • /
    • pp.40-47
    • /
    • 2013
  • In this paper, a numerical study was performed to investigate the performance characteristics of a pre-heater. The effects of fin pitch and fin array type(in-line, staggered, leaned array) were reported in terms of Colburn j-factor and Fanning friction factor f, as a function of Re. Three-dimensional numerical simulation has been performed by using flow analysis program, FLUENT 13.0. The results show that Colburn j-factor decreases with the decrease of fin pitch attached in the annular tube. But the fin pitch has little effect on f-factor. The staggered array and leaned array show improved heat transfer performance compared with in-line array, so that Colburn j-factor was increased. It also shows that the f-factor of leaned array is the highest in the studied range of Reynolds number.

HIGH RESOLUTION IMAGE ACQUISITION MODE USING PANCHROMATIC REDUNDANT CHANNEL

  • Chang, Young-Jun;Kong, Jong-Pil;Huh, Haeng-Pal;Kim, Young-Sun;Park, Jong-Uk
    • Proceedings of the KSRS Conference
    • /
    • v.2
    • /
    • pp.800-803
    • /
    • 2006
  • The Space-borne electro-optical camera system, like KOMPSAT has panchromatic redundant image channel as well as primary channel in order to increase reliability of satellite system. In most case redundant channel never been used during the whole mission period. Staggered array configuration using redundant image channel and new operation mode proposed which operates primary and redundant channel simultaneously. Without new hardware design, fast electronics and system complexity, we can get 1.414 times more fine GSD image of original system and aliasing effect which corrupt high frequency information of image can be minimized. To get the more efficiency from staggered array configuration, we introduce masked pixel CCD.

  • PDF

An Experimental Work on Cross Flow Induced Vibration of Staggered Array Pipe Bundles (어긋난 배열 을 갖는 파이프 집합체 의 횡유동 관련 진동 에 관한 실험적 연구)

  • 박윤식;이진희
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.1
    • /
    • pp.24-30
    • /
    • 1985
  • An experimental work to predict critical flow velocity to give whirling instability on staggered array tube banks model which is located in wind tunnel is presented. The critical flow velocity was obtained by measuring flow induced tube vibration on three tube array models having different pitch to diameter ratio as changing damping ratio and natural frequency of tube model. The obtained experimental results are directly compared with the numbers of other investigators and partly proved the truth of Blevin's new idea to predict critical flow velocity.

Numerical Study of Liquid Film Flow on Heat Exchanger Tube Arrangement and Configuration of Multi Effect Distillation (증발식 다중효용 담수기에서 열교환기 튜브 배열 및 형상에 따른 액막 유동에 관한 수치해석)

  • Jung, Il-Young;Yun, Sang-Kook;Joo, Hong-Jin;Kwak, Hee-Youl
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.68-73
    • /
    • 2011
  • This study was performed numerical analysis in order to analyze liquid film flow of heat exchanger tube arrangement and configuration of evaporative multi effect distillation system using medium-temperature. Simulation was accomplished the two-dimensional calculations using commercial analyses program FLUENT based on the FVM(finite volume method). Fresh water generator of this study used Shell & Tubes heat exchanger with Cu_Ni tube, configuration of tube used bare tube and corrugated tube, and arrangement of tube used in-line array and staggered array. Performance of heat exchanger through the formation of liquid film was compared and analyzed. Liquid film flow occurred that falling on heat exchanger tube wall. Result of simulation showed that liquid film thickness of in-line arrangement was found 0.57mm with bare tube and 0.67mm with corrugated tube, respectively. And liquid film thickness of staggered arrangement was found 0.39mm with bare tubes and 0.62mm with corrugated tubes, respectively. Liquid film thickness of corrugated tube showed thicker than bare tube, but heat transfer rates of corrugated tube showed higher than bare tube. The reason was considered that surface area of corrugated tube was wider than bare tube. And liquid film thickness of staggered arrangement showed thinner than in-line arrangement, so thermal performance of staggered arrangement showed higher than in-line arrangement.

  • PDF

Numerical Analysis on the Effects of Supply Channel and Jet Hole Arrangement on Heat Flow Characteristics of Impingement Jet (충돌제트에서의 유량공급 채널 및 제트 홀 배열에 따른 열유동 특성 수치해석)

  • Hwang, Byeong Jo;Chung, Heeyoon;Joo, Won Gu;Cho, Hyung Hee
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.20 no.4
    • /
    • pp.77-86
    • /
    • 2016
  • A numerical analysis is performed to investigate the effect of a supply channel and jet hole arrangement on the heat flow characteristics of impingement jet. The jet holes in a supply channel are composed of a single or staggered array from the center of a leading edge channel. The software ICEMCFD is used to generate the structured grids for calculation domain and a CFD code CFX 15.0 to perform the simulation. The present solutions are validated by comparison with the experimental and numerical ones of others. A comparison of mass flow rates of impingement jets and Nusselt numbers on the impingement surface for the single or staggered arrays is made.

The Effects of Impingement Hole Size on Heat Transfer of An Impingement/Effusion Cooling System (충돌제트/유출냉각기법에서 분사판의 홀배열이 열전달에 미치는 영향)

  • Choi, Jong-Hyun;Rhee, Dong-Ho;Cho, Hyung-Hee
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.489-496
    • /
    • 2001
  • Two perforated plates are used to investigate local heat/mass transfer characteristics in an impingement/effusion cooling system. A naphthalene sublimation method is conducted to determine the local heat/mass transfer coefficients on the upward facing surface of the effusion plate. The two plates are placed in parallel position with gap distances of 1, 2, 4 and 6 times of effusion hole diameter. The effects of hole arrangements of the plates are studied for staggered, square, and hexagonal arrays. The experiments are conducted at Reynolds number of 10,000 based on the effusion hole diameter. The results show that the smaller hole size in the staggered array has the higher transfer coefficients on the stagnation region due to the formation of higher momentum flows through the impingement holes. In the square array, heat/mass transfer on the target plate is more uniform as the number of impingement holes increases. High and uniform heat/mass transfer coefficients are obtained in the hexagonal array.

  • PDF

The Effects of Impingement Hole Arrangements on Heat Transfer of an Impingement/Effusion Cooling System (충돌제트/유출냉각기법에서 분사판의 홀배열이 열전달에 미치는 영향)

  • Choe, Jong-Hyeon;Lee, Dong-Ho;Jo, Hyeong-Hui
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.1
    • /
    • pp.101-109
    • /
    • 2002
  • Two perforated plates are used to investigate local heat/mass transfer characteristics in an impingement/effusion cooling system. A naphthalene sublimation method is conducted to determine the local heat/mass transfer coefficients on the upward facing surface of the effusion plate. Two plates are placed in parallel position with gap distances of 1, 2, 4 and 6 times of effusion hole diameter. The effects of hole arrangements of the plates are studied fur staggered, square, and hexagonal arrays. The experiments are conducted at Reynolds number of 10,000 based on the effusion hole diameter. The results show that the smaller hole size in the staggered array has the higher transfer coefficients on the stagnation region due to the formation of higher momentum flows through the impingement holes. In the square array, heat/mass transfer on the target plate is more uniform as the number of impingement holes increases. High and uniform heat/mass transfer coefficients are obtained for the hexagonal array.